Check local codes and read all instructions prior to installation.
HT34-PV
HT-Series PV Gas Fireplace
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualied installer, service agency or the gas supplier.
Safety Notice:
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Indoor
Warning:
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas
supplier, call the re department.
XG0530 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 041510
• Installer: Leave this manual
®
with the appliance.
• Consumer: Leave this
manual for future reference.
HT34-PV Series Power Vent Gas Fireplace
Warning:
Read this manual before installing, operating or troubleshooting this
appliance. Please retain this owner's manual for future reference.
Congratulations
Congratulations on selecting a Montigo gas replace, an elagent
and well designed gas replace built to your specications. The
Montigo gas replace you have selected is designed to provide
the utmost in safety, reliability, and engineering standards.
As the owner of this new replace, you'll want to read and carefully follow all the instructions contained in this Installation,
Operations and Maintenance manual. Pay special attention to all
cautions, warnings, and Important warnings.
This owner's manual should be retained for future reference. We
suggest that you keep it with all your other important documents
and product manuals.
The information contained in this owner's manual, unless noted
otherwise, applies to all models, and gas control systems.
Your new Montigo gas replace will give you years of durable,
reliable use. Welcome to the Montigo family of gas replace
products.
Safety Alert Key:
• DANGER!
Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
• Important: Used to address practices not related to personal injury.
The HT34-PV Series is an replace that is designed to compliment your
home and decor. This replace can be converted to both a Top Vent or
Rear Vent application, but requires a Power Vent for safe and trouble
free operation. (Refer to the Index)
The HT34DF-PV Series is available in the specic models below.
The HT34-PV is rated for Natural Gas and Liquid Propane at 30,000
Max. BTU/H (8.45) Kilowatts Input.
► HT34-PV-I; Top or Rear Vent convertible, Intermittent Pilot (HSI)
► HT34-PV-F; Top or Rear Vent convertible, (SIT Electronic Ignition).
This manual covers installation, operation and maintenance. Lighting,
operation and care of this replace can be easily performed by the
homeowner. However, all installation and service work should be
performed by a qualied or licensed installer, plumber, or gas tter who
is qualied or licensed by the state, province, region, or governing body
in which the appliance is being installed.
This manual covers all models and unless otherwise specied, the
designation HT34-PV refers to all variations of the model above. Sections
which are specic to a particular variation are marked with a
symbol, plus the appropriate model number.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent
assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in
combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements
for factory-built gas replaces. Installation & repairs should be done by
a qualied contractor.
Installations in Canada must conform to the current CAN/CGA B-149.1
and .2 Gas Installation Code and local regulations. If the optional aircirculating fan kit is installed, it must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the absence
of local codes to the National Fuel Gas Code, ANSI Z223.1-1988. If the
optional air-circulating fan is installed, it must be grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70-1987. See Appendix for installation
within the State of Massachusetts. This replace must comply with
NFPA-54 Chapter 10.
CAUTION!
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
Part No. XG0530 - 041510
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood ooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
Page 3
HT34-PV Series Power Vent Gas Fireplace
4
Installation
Installing The Fireplace Shell
The replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efciency of operation, must be considered when selecting
the replace location. Try to select a location that does not interfere
with room trafc, has adequate ventilation, and offers an accessible
pathway for Power Vent installation. Refer to page 4 - Vent Installation
for more information.
The replace dimensions for HT34-PV models are shown below:
22”
4”
7”
17 3/8”
1 1/4”
5 1/2”
37 1/8”
Opening
5 1/4”
8”
17 3/8”
Side View
7”
4”
40 1/4”
47 3/8”
9 1/2”
C
L
33 7/8”
Top View
31 3/8”
1 1/4
1 1/4”
47 7/8”
1”
Opening
”
Front View
Figure 1. Fireplace dimensions.
Framing
53 3/4”
34”
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
20”
Figure 2. Framing dimensions.
0” clearance to
corners only
37 3/8”
34”
52 5/8”
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
When installing a shelf over the top of the replace, the following
guidelines must be adhered to: For Rear Vent applications the
minimum clearance from the top of the replace to a shelf is 9". For
Top Vent applications, the minimum clearance is 17 1/2". (Minimum 2" clearance must still be maintained around the vent pipes.)
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The HT34-PV Series
clearances to combustible materials are:
HT34-PV
Top - Rear Vent *
Top - Top Vent
Back
Sides
Floor
Mantle**
17 1/2”
* Clearances from the top of the replace to a combustible ceiling
within the replace enclosure.
** Refer to page 14.
Unprotected combustible walls which are perpendicular to the replace
opening, must not project beyond the shaded area shown in Figure 25.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the replace.
Page 4
9"
2"
1"
0"
Note: PV venting Not exactly as shown.
MEL Short
Header
Shelf
Power Vent
9”
L
S
M
T
Rear Vent
Header
Shel
17 1/2”
Top Vent
f
Figure 4. Framing for shelves over the replace.
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood ooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
Part No. XG0530 - 041510
M
Installation
Figure 5b. Gas line access.
HT34-PV Series Power Vent Gas Fireplace
Installing The Gas Line
The gas line must be installed before nishing the HT34-PV Series
Fireplace. Natural Gas requires a minimum inlet gas supply pressure
of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a
minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of
10" W.C. Provision must also be made for a 1/8" N.P.T. plugged tapping
and be accessible for test gauge connection immediately upstream of
the gas supply controls to the appliance. The replace gas connection
and the main operating gas valve is located behind the removable trim
at the bottom of the unit and need only be attached to the gas line with
an approved tting, as required by the applicable installation codes.
To access the replace gas connection the main burner must be
removed as shown below in gure 5b.
• Only use gas shut-off valves approved for use by the state, province,
region, or governing body, in which the appliance is being installed, or
as required by the applicable installation codes.
• Flexible gas connectors must not exceed 3 feet in length, unless it is
allowable within applicable installation codes.
Gasline Acces
0.875 dia.
2
7
to center
Figure 5a. Gas line access.
Vent Installation
This section covers the installation of direct venting and terminations.
Installation Requirements
H
T34D-PV Series fireplaces are certified for use with Montigo Standard
Series (4" / 7") venting components.
Minimum clearance to combustible construction around the vent pipe
is 1" on all sides, except on horizontal venting where the top of the pipe
must have a clearance of at least 2".
Use only certied Montigo vent components. (Use of other parts will void
the Montigo warranty, and may impede the operation of the fireplace.)
All joints must be secured with a minimum of two screws per joint
Vent terminations must not be recessed in walls or siding
Horizontal runs must be supported by a minimum of two supports per horizontal
run. A minimum of one screw on each side of support is also required
Flex vent sections may be stretched up to 50% of their total length (eg. a
24" section may be stretched to 36")
Solid vent sections may be cut less than half way from the female end
Venting components can be used in any combination of solid/rigid pipe or flex
pipe and in any orientation (Male connectors can face in any direction)
Vent Terminations
Selecting A Termination Location
Choosing your vent termination location will help to determine whether
you need to use a top vent or rear vent replace. Figure 6a, below,
shows typical replace locations and the venting options they provide.
For a more detailed diagram of allowed termination locations, see Ap-pendix A.
Burner Tray Gasket
The appliance and its individual shut-off valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5 kPa).
Note: After gas line is connected, each appliance connection,
valve and valve train must be checked while under normal
operating pressure with either a liquid solution, or leak
detection device, to locate any source of leak. Tighten any
areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a ame of any kind to test for leaks.
Part No. XG0530 - 041510
Figure 6. Fireplace locations and vent terminations.
Cautions:
Vent terminations can be very hot. If the termination is less than 7 feet
above a public walkway, it should be fitted with a certified Montigo
Heat Guard. (Part no. PTKOG).
Do not obstruct, or attempt to conceal the vent termination.
These actions will affect the operation of the fireplace, and may
be hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.
Use Montigo Vinyl Heat Shield (Part no. VSS) when using on ap-
plications with vinyl siding to guard against possible damage.
Page 5
HT34-PV Series Power Vent Gas Fireplace
12
12
11
11
1212
12
Installation
Installing Terminations with Built-In Frames
MTO-3F (4"/7")
Figure 6a. Installing a MTO termination.
1. Frame the termination opening to 11" x 11".
2. Fasten the termination to the studs using a minimum of 4
screws.
Installing Terminations with MSR Frames
MSR
Installing Heat Guards over Terminations
MTKOG (4"/7")
PTKOG (5"/8")
Figure 6d. Installing a MTO termination heat guard.
1. Ensure that the two long mounting brackets are facing the bottom
of the termination. (See inset). This will provide more heat protection
at the top of the termination, where temperatures are highest.
2. Attach to the faceplate of the termination using four sheet metal
screws.
3. If installing the termination over Vinyl siding, Use the VSS Termination
shield. Montigo Installation document, XG1301.
Figure 6b. Installing a PTO termination with the MSR frame.
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
MOSR
MTO-3F (4"/7")
Figure 6c. Installing a PTO termination with the MOSR frame.
1. Frame the termination opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs using a
minimum of 4 screws.
3. Insert the termination into the MOSR frame as shown here, and
attach by screwing through the four pilot holes in the termination.
Page 6
MTO-3F (4"/7")
Figure 6e. Installing the VSS Vinyl Shield.
Installing The Standoffs
To avoid elevated mantel temperatures, all HT34-PV Series gas
replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these
standoffs on top of the replace ensuring that the height of the standoff
maintains a 6" clearance.
Figure 7. Installing the standoff's.
Part No. XG0530 - 041510