H38DF ST HL38DF ST
Indoor
DANGER
Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
Resi
dential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
®
XG0207
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
DANGER
IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
011012
H*38DF ST Indoor Gas Fireplace
NOTICE
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation
Before you Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Section 1: Installation Overview and Product Dimensions . . . . . . . . . . . .5
Section 2: Framing the Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 7
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Section 3: The Direct Vent System . . . . . . . . . . . . . . . . . . . . . . . . . . 8 - 15
Section 3-1: Converting from Top Vent to Side Vent . . . . . . . . . . . . .8
Section 3-2: Installing a Roof mounted Termination . . . . . . . . . . 9 - 10
▪ Roof mounted Terminations
Standard Top Vent (no elbows or offsets) . . . . . . . . . . . . . . . . . . . . 9
Top Vent (two elbows one offset) . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Top Vent (multi-elbows and offsets) . . . . . . . . . . . . . . . . . . . . . . . . 9
Standard Roof Vent (one elbows no offsets) . . . . . . . . . . . . . . . . 10
Section 3-3: Installing a Wall mounted Termination . . . . . . . . . . . . . 11
Standard PTO Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pre-installed MSR Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pre-installed BSR Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing MOSR Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing VSS Termination Shield . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing PTKOG Heat Guard . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Section 3-3-1: Venting Layout . . . . . . . . . . . . . . . . . . . . . . . . . 12 - 13
Top Vent, Wall mounted Graph, H*38DF-ST . . . . . . . . . . . . . . . .12
Top Vent, Wall mounted termination (one elbow) . . . . . . . . . . . . . . 12
Top Vent, Wall mounted termination (multi elbow) . . . . . . . . . . . . . 12
Side Vent, Wall mounted Termination Graph H*38DF-ST . . . . . . .13
Side Vent, Wall mounted termination (two elbows) . . . . . . . . . . . . 13
Section 3-3-2: Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . .14
Section 3-3-3: Heat Shields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing a RHS8 Wall Mounted Heat Shield . . . . . . . . . . . . . . . . 15
Installing a RHS101 Wall Mounted Heat Shield . . . . . . . . . . . . . .15
Section 4: Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SIT Proame gas control and pilot . . . . . . . . . . . . . . . . . . . . . . . 16
SIT Nova 820 gas control and pilot . . . . . . . . . . . . . . . . . . . . . .16
Honeywell gas control and pilot . . . . . . . . . . . . . . . . . . . . . . . . .16
Installing On/Off Wall Switch . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Installing optional Fan Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Section 5: Installing the Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Section 5-1: Section 5-2: Section 5-3:
Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Section 6: Finishing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Finishing around the replace . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Mantels and Surrounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Section 7: Installing and Removing the Door . . . . . . . . . . . . . . . . . . . . . 20
Section 8: Installing the Accessories . . . . . . . . . . . . . . . . . . . . . . . . 21 - 22
Installing the H38DF-ST Log Set . . . . . . . . . . . . . . . . . . . . . . . . . .21
Installing the HL38DF-ST Firestones . . . . . . . . . . . . . . . . . . . . . . .22
Section 9: Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 - 25
Start-up Sequence with Continuous Pilot . . . . . . . . . . . . . . . . . . . . 23
Start-up Sequence SIT Proame Gas valve . . . . . . . . . . . . . . . . . . 24
Start-up Sequence Honeywell Gas valve . . . . . . . . . . . . . . . . . . . . 25
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 - 28
▪ SIT Hi-Lo Burner Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
▪ SIT Nova 820 Pilot Burner Adjustment . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
SIT- Nova 820 Gas Control Valve . . . . . . . . . . . . . . . . . . . . . . .27
SIT Proame Electronic Gas Control Valve . . . . . . . . . . . . . . .27
Honeywell Gas Control Valve . . . . . . . . . . . . . . . . . . . . . . . . 27
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Appendix
C. State of Massachusetts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
A. Termination Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
B. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Page 2
XG0207 - 011012.1
H*38DF ST Indoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Safety Alert Key
DANGER WARNING
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage.
CAUTION NOTICE
Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
Introduction
INTRODUCTION
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you with a gas replace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. All installation and service work should be performed by a qualied or licensed installer, plumber or gastter as certied by the state, province, region or governing body where the replace is being installed.
This installation, operation and maintenance manual is applicable to the models described below. Refer to your rating plate to verify included options. Throughout this manual instructions are applicable to all models designated as H*38DF*-ST unless otherwise noted in the Table.
WARNING
Hot glass will cause burns. Do not touch glass until unit is cooled. Never allow children to touch glass.
Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage.
Address practices that are important, but not related to personal injury
MODEL
H38FSDN
H38FSDNE
H38FSDNI
H38FSDL
H38FSDLE
H38FSDLI
HL38FSDN
HL38FSDNE
HL38FSDNI
HL38FSDL
HL38FSDLE
HL38FSDLI
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Traditional Burner /
Logset
Linear Burner w/
Glass Accessories
Standing Pilot
Ignition
Honeywell Hot
Surface Ignition
X 34,000 X X
X 34,000 X X
X 34,000 X X
X 32,000 X X
X 32,000 X X
X 32,000 X X
X 34,000 X X
X 34,000 X X
X 34,000 X X
X 32,000 X X
X 32,000 X X
X 32,000 X X
SIT Electronic
Ignition
Warranty Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct­Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual. Consult your local Gas Inspection Branch on installation requirements
for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
XG0207 - 011012.1
Page 3
H*38DF ST Indoor Gas Fireplace
Installation
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The H*38DF*-ST Direct Vent replace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual rst. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this replace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least annually by a professional. More frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the fireplace are kept clean.
Installation Checklist
 Determine the desired install location of your replace.  See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
 Select the location of your termination and resulting vent run.
 Your selected termination location must be the highest point
in the Direct Vent installation.
 Should it be impossible to meet the venting requirements laid
out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent.
 Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
 Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
 Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
 Refer to local codes and guidelines for installation requirements.
 Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the local codes or in the absence of local codes to the current version of Natural Gas and Propane Installation Code, CSA B149. Electrical Installations must conform to the local codes or, in the absence of local codes, to the current version of Canadian Electrical Code, CSA C22.1.1
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies. Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance.
DANGER
When this appliance is installed directly on any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance or a fire will occur causing serious injury, property damage or even death.
Installations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical Installations must conform to the local codes or, in the absence of local codes, to the current version of the National Electrical Code, ANSI/NFPA 70. See Appendix C for installation within the State of Massachusetts.
Page 4
XG0207 - 011012.1
Installation
2
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your replace.
The H*38DF*-ST replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing.
The replace dimensions are shown below:
Top View
36 1/4"
FIREBOX
8
24”
FIREBOX
5
H*38DF ST Indoor Gas Fireplace
Safety, as well as efciency of operation, should be considered when selecting the replace location. Select a location that does not interfere with room trafc, has adequate ventilation and offers an accessible path for Direct Vent installation.
7"
4”
REF.
36 1/2”
6 1/4"
5 1/4"
37 3/4”
WIDTH
35 1/4"
OPENING
37 3/4”
Front View
Both Sides Typical
40"
25"
OPENING
Figure 1. Fireplace dimensions (Tolerance ± ").
5 8
Side View
33 1/2"
40 1/2"
XG0207 - 011012.1
Page 5
H*38DF ST Indoor Gas Fireplace
N
O
M
P
C
Section 2: Framing
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 41¾" wide, x 42½" high x 23¾" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 21.
41¾” (rough opening)
Both walls Typical. May not be exactly as shown.
42½”
Non-Combustible material Backframe, 2-pieces. Both Sides Typical. See figure 3.
23¾”
ombustible material Backframe,
2-pieces. Both Sides Typical.
Combustible Header
Combustible Shelf
2” Min.
17 1/2”
Min.
PEL Short 90 elbow
46” Min
42 1/2”
Figure 5. Combustible Framing for shelves over the replace, Top vent.
Top Vent
Ceiling level
Non-Combustible
Min. 1 ”
materials. Alcove over fireplace.
Figure 2. Framing dimensions, (Both Sides Typical).
40 3/4”
Figure 3. Securing the replace to the framing cleats.
Combustible material Backframe, 2-pieces. Both Sides Typical.
Combustible Header
Combustible Shelf
10”
Min.
33 1/2”
Exterior Wall
42 1/2”
Combustible
Header
Non-Combustible Header
Non-Combustible Nail­ing Flange, (supplied). Both sides Typical.
10”
See figure
8.
6"
42 1/2”
Figure 6. Non Combustible Framing with alcove above replace, Right side. Combustible Framing above replace, Left side, see gure 2 (Top Vent).
Floor
36 1/2”
Figure 4. Combustible Framing for shelves over the replace, Side vent.
Page 6
XG0207 - 011012.1
Installation
H*38DF ST Indoor Gas Fireplace
Clearances
When installing a shelf over the top of the replaces, the following guidelines must be adhered to:
For Side Vent applications, the minimum clearance is 2" from the side of the replace to a wall, or any combustible materials, and 10" clearance from the top of the replace to the underside of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 2" from the side of the replace to a wall, or any combustible materials, and 17 1/2" to the underside of any combustible shelf materials.
1” clearance is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.
MODEL
H*38DF*-ST 10" 17 1/2" 2" 0" 4"
Top - Side Vent
Top - Top Vent
Sides
Floor
Mantel
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38DF*-ST gas replaces are required to have the supplied standoffs installed. The replace is supplied with two standoffs. Bend and install these standoffs on top of the replace ensuring that the height of the standoff maintains a 6" clearance.
6”
Figure 7. Installing the standoff's (Both sides typical).
Installing the Nailing Flange Extension
Once the replace is placed into the rough framed opening, the supplied Nailing Flange Extension (Part No. H42074) must be fasten securely into place, with nails or wood screws. as shown in Figure 8.
Note: Clearance from top of replace to a combustible ceiling within the replace enclosure.
6"
Figure 8. Installing the Nailing Flange Extension (Both sides typical).
The Supplied nailing extension must be placed along the top edge of the replace and securely fastened in place to the non combustible header and combustible wood framing.
Note: The nailing ange extension can be substituted with a piece of NON-Combustible material of the same size and thermal characteristics,
ie: cement board or equivalent. This is recommended in applications where the facing materials will not adhere to the metal nailing ange.
XG0207 - 011012.1
Page 7
H*38DF ST Indoor Gas Fireplace
C
Installation
Section 3: Venting
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be
selected such that it provides the shortest vent run possible. Should it be impossible to ensure that the termination is the highest point or should it be impossible to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options.
8” Outer Flue Cover Plate
5” Inner Flue Cover Plate
NOTES FOR PLANNING VENTING:
Venting originates from the unit through the top or through
the side
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer
to the appropriate section below for installation details
All replaces shipped from the factory are Top vent.
Section 3-1: CONVERTING TO SIDE VENT
Use the following instructions to convert a H*38DF*-ST for Rear Vent use:
1. Remove the Side ue cover and gasket (5" and 8") on the ue outlet, as shown in Figure 9.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet, as shown in Figure 9.
3. Install the (removed) Side ue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 9a.
8” Outer Flue Collar
5” Inner Flue Collar
Figure 9a. Flue cover and collar installation, Side Vented replace.
Flue Collar
8” Outer Flue Collar
5” Inner Flue
over Plate
Outer Flue
Plate
Figure 9. Flue cover and collar removal, Top Vented replace.
Page 8
XG0207 - 011012.1
Installation
H*38DF ST Indoor Gas Fireplace
Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT TERMINATION (PVTK-1)
This section applies to installations where the direct vent termination will be roof mounted.
Section 3-2-1: VENTING LAYOUT Selection of components and details of venting lay out should
adhere to the following guidelines:
 The maximum termination point is 32’ above the replace (NOTE:
if the maximum termination height is used, the ame pattern may be affected).
 The Vertical termination must be a minimum 2’ higher than where
the termination exits the roong materials, (asphalt shingles, cedar shakes, etc). This distance should be measured from the high side of the roof slope where the ue ashing intersects the roong materials. (see Figures 10 to 10c).
 Termination location must be a minimum 6’ from a mechanical
air inlet.
 Termination location must be a minimum 18” from a parapet wall  For a more detailed diagram of allowed termination locations,
see Appendix A.
 A maximum of two offsets (each offset is made up of 2-90°
bends) may be made.
 Firestops must be installed as required by National & local codes.  Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting.
 Install all roof ashing and storm collars as shown.
PVTK1 Termination
Figure 10a. Top vent, Roof mounted with 1 offset (1 offset= two 90° bends).
PVTK1 Termination
Roof mounted Terminations
The following details are some possible congurations for Roof mounted terminations.
PVTK1 Termination
Figure 10. Top vent, Roof mounted termination with no offset in vent run.
Figure 10b. Top vent, Roof mounted with 2 offsets (1 offset= two 90° bends).
XG0207 - 011012.1
Page 9
H*38DF ST Indoor Gas Fireplace
PVTK1 Termination
Installation
PEXT Solid Sectio
12” Max.
Figure 10c. Side vent, Roof mounted venting (1 = 90° bend).
n
Page 10
XG0207 - 011012.1