Montigo H- DF, H42DF-O Operation Manual

Installation
®
C US
Operation & Maintenance
Installation and service must be performed by a qualied
installer, service agency, or the gas supplier.
H-Series DF
Outdoor Gas Fireplace
Safety Notice:
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional
information consult a qualied installer,
service agency or the gas supplier.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the re department.
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Check local codes and read all instructions prior to installation.
Installer: Leave this manual
with the appliance.
Consumer: Leave this man-
ual for future reference.
Warning:
Read this manual before installing, operating or troubleshooting this
appliance. Please retain this owner's manual for future reference.
Congratulations
Congratulations on selecting a Montigo gas replace, an elagent and well designed gas replace built to your specications. The Montigo gas replace you have selected is designed to provide the utmost in safety, reliability, and engineering standards.
As the owner of this new replace, you'll want to read and carefully follow all the instructions contained in this Installation, Operations and Maintenance manual. Pay special attention to all cautions, warnings, and Important warnings.
Safety Alert Key:
This owner's manual should be retained for future reference. We suggest that you keep it with all your other important documents and product manuals.
The information contained in this owner's manual, unless noted other­wise, applies to all models, and gas control systems.
Your new Montigo gas replace will give you years of durable, reliable use. Welcome to the Montigo family of gas replace products.
• DANGER!
Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
• Important: Used to address practices not related to personal injury.
Table Of Contents
Congratulations
Safety Alert Key
Introduction ................................................................................. 3
Installation
Installing and Framing the Fireplace ..............................4
Installing the Gasline ...................................................... 5
Vent Installation .............................................................. 5
Installation Requirements .................................. 5
Installing the Remote Switch ............................. 5
Vent Terminations .............................................. 6
Installing the Nailing ange ................................ 6
Top Vent Runs .........................................................7 - 12
Side Vent Runs .......................................................8 - 13
Finishing around the replace
Fireplace Facing .............................................. 13
Mantels and Surrounds ................................... 13
Wiring .........................................................................14
Removing and Installing the Door ................................15
Installing Logset ....................................................16 - 17
Operation .........................................................................16 - 20
Maintenance .................................................................... 20 - 22
Troubleshooting ..................................................... 20 - 21
Spare Parts .................................................................. 22
Warranty .................................................................................23
Appendix
A. Termination Locations .............................................. 24
B State of Massachusetts / Amendment .....................25
H42DF-O Outdoor Gas Fireplace
Introduction
Thank You for choosing a Montigo Gas Fireplace.
About this Fireplace:
The H42DF-O is an outdoor replace' with a linear-style burner. This replace can be converted to both a Top Vent or Rear Vent application, and are only available in a H42DF-O model.
The H42DF-O is rated for Natural Gas at 34,000 Max. BTU/H (9.96) Kilowatts Input and 28,000 Min. BTU/H (7.33) Kilowatts.
► H42DF-O; Top or Rear Vent convertible, Millivolt Pilot (LP Models Top Vent ONLY).
► H42DF-O-I; Top or Rear Vent convertible, Intermittent Pilot (HSI) (LP Models Top Vent ONLY).
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. However, all installation and service work should be performed by a qualied or licensed installer, plumber, or gas tter who is qualied or licensed by the state, province, region, or governing body in which the appliance is being installed.
This manual covers all models and unless otherwise specied, the designation H42DF-O refers to all variations of the model above. Sections which are specic to a particular variation are marked with a symbol, plus the appropriate model number.
CAUTION!
Due to its high operating temperatures, the appliance should be located out of traffic & away from furniture and draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
WARNING!
When this appliance is installed directly on carpeting, tile or any combustible material other than wood ooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
Installations in Canada must conform to the current CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations. If the optional air­circulating fan kit is installed, it must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the absence of local codes to the National Fuel Gas Code, ANSI Z223.1-1988. If the optional air-circulating fan is installed, it must be grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987. See Appendix for installation within the State of Massachusetts. This replace must comply with NFPA-54 Chapter 10.
Part No. XG0149
Page 3
H42DF-O Outdoor Gas Fireplace
36 1/2
37 3/4
35 1/4
1 1/4
1 1/4
1 1/4
1
5 1/2”
5 1/4”
25 3/4
18 1/2”
25”
J
K
C
L
C
L
8”
5”
46 3/8
50 1/8
10
40 1/8
Header
Header
Shelf
MELShort
Shelf
33
46 3/8
19
Installation
Installing The Fireplace Shell
The replace may be installed in any location that maintains proper clear­ances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efciency of operation, must be considered when selecting the replace location. Try to select a location that does not interfere with room trafc, has adequate ventilation, and offers an accessible pathway for Direct Vent installation. Refer to page 4 - Vent Installation for more information.
The replace dimensions are shown below:
Top View
18 1/2”
8”
5”
36 1/2
28 3/4
Side View
Front View
Figure 1. Fireplace dimensions.
Framing
46 3/8”
37 3/4”
* When sheetrock is not used behind the fireplace, framing depth may be reduced by 5/8"
20 1/8”
Figure 2. Framing dimensions.
48 1/8”
42”
68”
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
When installing a shelf over the top of the replace, the following guidelines must be adhered to: For Rear Vent applications the minimum clearance from the top of the replace to a shelf is 9". For Top Vent applications, the minimum clearance is 17 1/2". (Minimum 2" clearance must still be maintained around the vent pipes.)
Clearances
These clearances apply to all dimensions except the framed opening, where the clearance to combustibles is 0". The H42DF-O clearance to unprotected combustible walls which are perpendicular to the replace opening, must not project beyond the shaded area shown in Fig. 24.
For protection against freezing temperatures, it is recommended that outer walls of the chase be insulated with a vapor barrier. This will reduce the possibility of a cold-air convection current on the replace.
Top - Rear Vent * 9" Top - Top Vent 17 Back 1" Sides 1" Floor 0" Mantle** 4"
* Clearance from top of the Fireplace to a combustible ceiling within the fireplace enclosure. ** Refer to Pages, 10 & 11.
Page 4
H42DF-O
1
/
2"
Rear Vent
Top Vent
Figure 4. Framing for shelves over the replace.
WARNING!
When this appliance is installed directly on carpeting, tile or any combustible material other than wood ooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance.
Part No. XG0149
Installation
Burner Tray Gasket
Figure 5b. Gas line access.
H42DF-O Outdoor Gas Fireplace
Installing The Gas Line
The gas line must be installed before nishing the H42DF-O Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T. plugged tapping and be accessible for test gauge connection immediately upstream of the gas supply controls to the appliance. The replace gas connection and the main operating gas valve is located behind the removable trim at the bottom of the unit and need only be attached to the gas line with an approved tting, as required by the applicable installation codes.
To access the replace gas connection the main burner must be removed as shown below in gure 5b.
• Only use gas shut-off valves approved for use by the state, province, region, or governing body, in which the appliance is being installed, or as required by the applicable installation codes.
• Flexible gas connectors must not exceed 3 feet in length, unless it is allowable within applicable installation codes.
Gasline Acces
0.875 dia.
2
7
to center
Figure 5a. Gas line access.
Vent Installation
This section covers the installation of direct venting and terminations.
Installation Requirements
H42DF-O fireplace are certified for use with Montigo Standard Series (5" / 8") venting components.
Minimum clearance to combustible construction around the vent pipe
is 1" on all sides, except on horizontal venting where the top of the pipe
must have a clearance of at least 2".
Use only certied Montigo vent components. (Use of other parts will void
the Montigo warranty, and may impede the operation of the fireplace.)
All joints must be secured with a minimum of two screws per joint
Vent terminations must not be recessed in walls or siding
Horizontal runs must be supported by a minimum of two supports per horizontal
run. A minimum of one screw on each side of support is also required
Flex vent sections may be stretched up to 50% of their total length (eg. a
24" section may be stretched to 36")
Maximum horizontal run with no vertical rise is 6 feet.
Flex vent sections over 6 feet must fall within the limits set by the venting
graph and must have a minimum vertical rise of 3 inches per foot of flex.
Solid vent sections may be cut less than half way from the female end
Venting components can be used in any combination of solid/rigid pipe or flex
pipe and in any orientation (Male connectors can face in any direction)
Vent Terminations
Selecting A Termination Location
Choosing your vent termination location will help to determine whether you need to use a top vent or rear vent replace. Figure 6a, below, shows typical replace locations and the venting options they provide.
For a more detailed diagram of allowed termination locations, see Ap- pendix A.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Note: After gas line is connected, each appliance connection,
valve and valve train must be checked while under normal
operating pressure with either a liquid solution, or leak detection device, to locate any source of leak. Tighten any areas where bubbling appears or leak is detected until bubbling stops completely or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.
Part No. XG0149
Figure 6a. Fireplace locations and vent terminations.
CAUTION!
Due to its high operating temperatures, the appliance should be located out of traffic & away from furniture and draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
Page 5
H42DF-O Outdoor Gas Fireplace
12
12
11
11
1212
12
Installation
Installing Terminations with Built-In Frames
MTO-3F (4"/7") PTO-3F (5"/8")
1. Frame the termination opening to 11" x 11".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MSR Frames
MSR
Installing Heat Guards over Terminations
MTKOG (4"/7") PTKOG (5"/8")
1. Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset). This will provide more heat protection at the top of the termination, where temperatures are highest.
2. Attach to the faceplate of the termination using four sheet metal screws.
Installing The Standoffs
To avoid elevated mantel temperatures, all H42DF-O gas replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these standoffs on top of the replace ensuring that the height of the standoff maintains a 6" clearance.
MTO-3 (4"/7") PTO-3 (5"/8")
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
MOSR
MTO-3 (4"/7") PTO-3 (5"/8")
1. Frame the termination opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs using a minimum of 4 screws.
3. Insert the termination into the MOSR frame as shown here, and attach by screwing through the four pilot holes in the termination.
Page 6
Figure 6b. Installing the stando's.
Installing the Nailing Flange
Extension
Once the replace is placed into the framed opening, the supplied nailing extension must be placed along the top edge of the replace, and nailed in place to the framing, as illustrated below.
Figure 6c. Installing the Nailing Flange Extension.
Installing The Remote Switch
The H42DF-O's gas valve, located behind the lower trim, may be connected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Refer to Figure 26 for wiring requirements.
Note: The switch location must not exceed 30' from the replace.
Part No. XG0149
Installation
H42DF-O Outdoor Gas Fireplace
Converting to Top Vent/ Rear Vent
H-Series DF Top Vent
Use the following instructions to convert an H42DF-O for Top Vent use:
Install the 4" or 5" inner ue cap on the rear ue outlet and secure 1. the cap in place with ve screws, as shown in gure 7a. Install the 7" or 8" outer ue cap on the rear ue outlet, and secure 2. it with ve screws, as shown in gure 7a.
5” Inner Flue Cap
8” Outer Flue Cap
Figure 7a. Flue cap installation for Top Vented replace.
Install the ue gasket material and ue cover plate on the rear vent 3. outlet . Fasten the plate with four screws, as illustrated below. Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4. collar in place on the top vent outlet using 5 screws, as illustrated below.
5” Inner Flue Collar
8” Outer Flue Collar
H-Series DF Rear Vent
Use the following instructions to convert an H42DF-O for Top Vent use:
Install the 4" or 5" inner ue cap on the top ue outlet and secure 1. the cap in place with ve screws, as shown in gure 8a.
Install the 7" or 8" outer ue cap on the top ue outlet, and secure 2. it with ve screws, as shown in gure 8a.
8” Outer Flue Cap
5” Inner Flue Cap
Figure 8a. Flue cap installation for Rear Vented replace.
Install the ue gasket material and ue cover plate on the top 3. vent outlet. Fasten the plate with four screws, as illustrated in gure 8b.
Install the 4" or 5" inner ue collar and the 7" or 8" outer ue 4. collar in place on the rear vent outlet using 5 screws, as illustrated below.
Figure 7b. Flue collar installation for Top Vented replace.
Important: Natural Gas and Propane equipped models may be installed using Top or Rear Vent applications.
However, the Propane equipped H42DF-O models must be installed in a top vent application only.
Part No. XG0149
8” Outer Flue Collar
5” Inner Flue Collar
Figure 8b. Flue collar installation for Rear Vented replace.
Page 7
H42DF-O Outdoor Gas Fireplace
Installation
Top Vent Venting Runs
For the H42DF-O Top Vent, there are two types of installations: A) Through-The-Wall Installations and B) Vertical (Through-The-Roof) Installations.
A) Through-The-Wall Installations
Before you install any venting, you must determine whether the venting run will be acceptable. Unacceptable venting can affect the replace's combustion.
The Venting Graph
Measure the vertical height from the replace hearth to the centre of the termination and the horizontal run from the replace ue collar to the wall ange of the termination. Plot on the Venting Graph (Fig. 9a) with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the horizontal run to the wall flange of the vent termination is 36", this would be an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to the wall flange of the vent termination is 120", this would be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and the horizontal run to the wall flange of the vent termination is 84", this would
NOT be an acceptable installation.
Available Top Vent Components
The following venting components are available for the H42DF-O Top Vent:
4" / 7" Venting 5" / 8" Venting
A - Termination MTO-3 (3" Length)
B - Stucco Kits MSR (Stucco Frame)
C - Flex Sections MFL-1 (12" Section)
D - Rigid
Sections
E - Elbows MEL-90MM (m/m 90° Elbow)
MTO-3F (3" Length)
MOSR (Stucco Can) BSR ( Brick Can)
MFL-2 (24" Section) MFL-3 (36" Section) MFL-4 (48" Section)
MEXT-1 (12" m/f Section) MEXT-2 (24" m/f Section) MEXT-3 (36" m/f Section) MEXT-4 (48" m/f Section)
MEL-90FF (f/f 90° Elbow) MEL-90FM (f/m 90° Elbow)
NOTES: All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 7).
Example 1:
For our shortest venting conguration use components A and E (see Figure 10).
PTO-3 (3" Length) PTO-3F (3" Length)
MSR (Stucco Frame) MOSR (Stucco Can) BSR ( Brick Can)
PFL-1 (12" Section) PFL-2 (24" Section) PFL-3 (36" Section) PFL-4 (48" Section)
PEXT-1 (12" m/f Section) PEXT-2 (24" m/f Section) PEXT-3 (36" m/f Section) PEXT-4 (48" m/f Section)
PEL-90MM (m/m 90° Elbow) PEL-90FF (f/f 90° Elbow) PEL-90FM (f/m 90° Elbow)
Figure 9c. H42DF-ODTop Vent Venting Graph
NOTES: All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 7).
Page 8
RHS8 Heat Shield
PEL
PEL-90F/F Elbow
Figure 10. Typical Top Vent installation. If the 90° elbow is installed
directly on the replace, for height to the center of the termination see chart on page 3.
Important:
An inspection of the explosion relief appers and door must be
made prior to lighting the replace. This will ensure the door gas-
keting material will provide an adequate seal during operation.
Part No. XG0149