Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
WARNING
FOR OUTDOOR USE ONLY.
Resi
dential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
®
CUS
XG0817 080311
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
WARNING
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has
no odor. Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a
camper, tent, car or home.
You must read and understand this
manual prior to installation, operation or
troubleshooting this appliance. Please
retain this owner’s manual for furure
reference and maintenance.
Page 2
XG0817 - 080311
H*38SVO-ST Outdoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Safety Alert Key
DANGERWARNING
Indicates a hazardous situation which, if not
avoided, WILL result in death or serious
injury or property damage.
CAUTIONNOTICE
Indicates a hazardous situation which, if not
avoided, WILL result in minor or moderate
injury.
Introduction
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you
with a gas replace that is not only a beautiful addition to your space, but
that is also designed and manufactured to the highest safety, reliability
and engineering standards.
We strongly encourage you to read and carefully follow the instructions
laid out in this Installation, Operation and Maintenance Manual and retain
it for your future reference. Pay special attention to all cautions, warnings,
and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting,
operation and care of this replace can be easily performed by the
homeowner. All installation and service work should be performed by
a qualied or licensed installer, plumber or gas tter as certied by the
state, province, region or governing body where the replace is being
installed.
This installation, operation and maintenance manual is applicable to the
models described. Refer to your rating plate to verify included options.
How to use this manual:
This manual covers installation, operation and maintenance. Lighting,
operation and care of this replace can be easily performed by the
homeowner. However, all installation and service work should be
performed by a qualied or licensed installer, plumber, or gastter who
is qualied or licensed by the state, province, region, or governing body
in which the appliance is being installed.
WARNING
Hot glass will cause
burns. Do not touch
glass until unit is cooled.
Never allow children to
touch glass.
Indicates a hazardous situation which, if not
avoided, COULD result in death or serious
injury or property damage.
Address practices that are important, but
not related to personal injury
MODEL
H38VOSTN
H38VOSTNI
H38VOSTL
H38VOSTLI
HL38VOSTN
HL38VOSTNI
HL38VOSTL
HL38VOSTLI
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Traditional Burner /
Logset
Contemporary
Burner w/River rock
Linear Burner w/
Glass Accessories
Standing Pilot
Ignition
X45,000XX
X45,000XX
X 45,000XX
X 45,000XX
X45,000XX
X45,000XX
X 45,000XX
X 45,000XX
Honeywell Hot
Surface Ignition
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
► Modication of the replace and/or components including
Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by
Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements
for factory-built gas replaces. Installation & repairs should be done by
a qualied contractor.
The H38SVO Ventless replace must be installed in accordance with
these Instructions. Carefully read all the Instructions in this manual
rst. Consult the Local Gas Branch to determine the need for a permit
prior to starting the installation. It is the responsibility of the installer to
ensure this replace is installed in compliance with the manufacturers
instructions and all applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an
authorized gas fireplace service technician. The
appliance should be inspected before use and at
least annually by a professional. More frequesnt
cleaning may be required due to exessive lint from
carpeting, bedding material, ect. It is imperative
that control compartments, burners and circulating
air passageways of the fireplace are kept clean.
XW2016
Installation Checklist
Determine the desired install location of your replace. See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
Refer to local codes and guidelines for installation requirements.
Installation and repairs should be done by a qualied
contractor and must conform to:
• Installations inCanada must conform to the current CAN/CGA
B-149.1 and .2 Gas Installation Code and local regulations.
• Installations in theUSA must conform to local codes, or in the
absence of local codes to the National Fuel Gas Code, ANSI Z223.1
• See Appendix C for installation within the State of Massachu-setts. This replace must comply with NFPA-54 Chapter 10.
.
CAUTION
Due to high operating temperatures, this appliance
should be located out of traffic & away from
furniture and draperies.
Children and adults should be alerted to the
hazards of the high surface temperature, which
could cause burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the appliance.
Clothing or other flammable materials should not
be placed on or near the appliance.
XW2018
DANGER
When this appliance is installed directly
on any combustible material other than
XW2020
wood flooring, it must be installed on a
metal or wood panel extending the full
width and depth of the appliance or a
fire will occur causing serious injury,
property damage or even death.
Page 4
XG0817 - 080311
H*38SVO-ST Outdoor Gas Fireplace
Backframe Min. 38"both sides Typical
41"
Surrounding construction
(bottom,sides and top) must be non-combustible materials,metal studs,concrete boardand concrete,brick,or stone.
Top View
Side View
36½"
Height
24"
24”
36⅞" Width
Installation
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information
on preparing for a successful installation of your replace.
The H-Series VO replace may be installed in any location that maintains
proper clearances to air conditioning ducts, electrical wiring and plumbing.
The replace dimensions are shown below:
24”
36⅞" Width
Top View
Safety, as well as efciency of operation, should be considered when
selecting the replace location. Try to select a location that does not
interfere with room trafc, has adequate ventilation and offers an
accessible path for Direct Vent installation.
24"
36½"
Height
Side View
35⅝" Opening
36⅞" Width
1¼"
1¼"
1"
Front View
Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).
6¾"
25¾"
Opening
5¼"
XG0817 - 080311
Page 5
H*38SVO-ST Outdoor Gas Fireplace
41"
Backframe Min. 38"both sides Typical
41"
Surrounding construction(bottom,sides and top) must be non-combustible materials,metal studs,concrete boardand concrete,brick,or stone.
Section 2: Framing
Installation
Installing The Fireplace Shell
The replace may be installed in a location that maintains clearances to
ALL exterior furniture, appliances and other exterior equipment. Safety,
as well as efciency of operation, must be considered when selecting
the replace location. Try to select a location that does not interfere with
foot trafc, has adequate ventilation, and offers an accessible pathway
for ventilated gasses.
The replace dimensions with the Optional Stainless steel cover, shown
below. (Note: This model is intended as a stand-alone).
25⅛”
40⅛" Width
Top View
35⅜" Opening
Framing (stand-alone):
For Fireplace without the Optional Stainless steelsurround.
Combustible
materials
36”
38”
40”
41”
Figure 3. Framing dimensions (without Optional surround). Must be back-
framed as shown in Figure 2a below.
23 7/8”
6¾"
37⅝"
25¾"
Opening
5¼"
40⅛" Width
Front View
Figure 2. Fireplace dimensions with insulation jacket
Page 6
XG0817 - 080311
Loading...