Montigo H38VO-ST, HL38VO-ST Maintance Manual

Installation & Maintenance Manual
H38VO-ST HL38VO-ST
Outdoor Ventless See Through
DANGER
Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
WARNING
FOR OUTDOOR USE ONLY.
Resi
dential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.
®
XG0817 080311
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
WARNING
CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home.
H*38SVO-ST Outdoor Gas Fireplace
XW2010
Table of Contents
Introduction .................................................................................3
Models .................................................................................3
Installation
Before you Start .................................................................................4
Installation Checklist ...............................................................................4
Section 1: Installation Overview and Product Dimensions
Section 2: Framing the Fireplace
Clearances ............................................................................6 - 7
Finishing around the Fireplace ...........................................................7
Section 3:
Section 4:
▪ Honeywell gas control and pilot ..............................................8
Section 5: Installing the Gas Line
Section 5-1: Fuel Conversion ..................................................................9
Section 5-2: Gas Pressure ......................................................................9
Section 5-3: Gas Connection ..................................................................9
Section 6:
Section 7: Installing and Removing the Door
Section 8: Installing the Accessories
▪ Installing the H34VO Log Set .................................................... 11
▪ Installing the H38VO Log Set ....................................................12
▪ Installing the H42VO Log Set ....................................................13
▪ Installing the HL38VO Firestones ..............................................14
Section 9: Operation ........................................................15 - 16
▪ Start-up Sequence with Continuous Pilot ..................................15
▪ Start-up Sequence with Honeywell Electronic Ignition .............16
Maintenance
▪ General ...............................................................................17
▪ Cleaning ...............................................................................17
▪ Hi-Lo Burner Adjustment ............................................................17
▪ Pilot Burner Adjustment .............................................................17
▪ Replacement Parts ....................................................................18
Appendix
A. Termination Locations ..............................................................19
B. Warranty ...............................................................................20
C. State of Massachusetts. ..........................................................21
Venting ............................................................................. N/A
Wiring .................................................................................8
.............................................................................N/A
.......................................................................17 - 18
...........................................................6
...........................................................9
.......................................10
............................................. 11 - 14
.....................5
NOTICE
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
Page 2
XG0817 - 080311
H*38SVO-ST Outdoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Safety Alert Key
DANGER WARNING
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage.
CAUTION NOTICE
Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
Introduction
Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you
with a gas replace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. All installation and service work should be performed by a qualied or licensed installer, plumber or gas tter as certied by the state, province, region or governing body where the replace is being installed.
This installation, operation and maintenance manual is applicable to the models described. Refer to your rating plate to verify included options.
How to use this manual:
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. However, all installation and service work should be performed by a qualied or licensed installer, plumber, or gastter who is qualied or licensed by the state, province, region, or governing body in which the appliance is being installed.
WARNING
Hot glass will cause burns. Do not touch glass until unit is cooled. Never allow children to touch glass.
Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage.
Address practices that are important, but not related to personal injury
MODEL
H38VOSTN
H38VOSTNI
H38VOSTL
H38VOSTLI
HL38VOSTN
HL38VOSTNI
HL38VOSTL
HL38VOSTLI
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Traditional Burner /
Logset
Contemporary
Burner w/River rock
Linear Burner w/
Glass Accessories
Standing Pilot
Ignition
X 45,000 X X
X 45,000 X X
X 45,000 X X
X 45,000 X X
X 45,000 X X
X 45,000 X X
X 45,000 X X
X 45,000 X X
Honeywell Hot
Surface Ignition
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual. Consult your local Gas Inspection Branch on installation requirements
for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
XG0817 - 080311
Page 3
H*38SVO-ST Outdoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
XW2020-When-Installed_[EN].pdf 1 1/24/2011 12:48:53 PM
Installation
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The H38SVO Ventless replace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual rst. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this replace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least annually by a professional. More frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, ect. It is imperative that control compartments, burners and circulating air passageways of the fireplace are kept clean.
XW2016
Installation Checklist
 Determine the desired install location of your replace.  See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
 Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
 Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
 Refer to local codes and guidelines for installation requirements.
 Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the current CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations.
Installations in the USA must conform to local codes, or in the absence of local codes to the National Fuel Gas Code, ANSI Z223.1
See Appendix C for installation within the State of Massachu- setts. This replace must comply with NFPA-54 Chapter 10.
.
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies. Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance.
XW2018
DANGER
When this appliance is installed directly on any combustible material other than
XW2020
wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance or a fire will occur causing serious injury, property damage or even death.
Page 4
XG0817 - 080311
H*38SVO-ST Outdoor Gas Fireplace
Backframe Min. 38" both sides Typical
41"
Surrounding construction
(bottom, sides and top) must be non-combustible materials, metal studs,concrete board and concrete, brick, or stone.
Top View
Side View
36½"
Height
24"
24”
36⅞" Width
Installation
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your replace.
The H-Series VO replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing.
The replace dimensions are shown below:
24”
36⅞" Width
Top View
Safety, as well as efciency of operation, should be considered when selecting the replace location. Try to select a location that does not interfere with room trafc, has adequate ventilation and offers an accessible path for Direct Vent installation.
24"
36½"
Height
Side View
35⅝" Opening
36⅞" Width
1¼"
1¼"
1"
Front View
Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).
6¾"
25¾" Opening
5¼"
XG0817 - 080311
Page 5
H*38SVO-ST Outdoor Gas Fireplace
41"
Backframe Min. 38" both sides Typical
41"
Surrounding construction (bottom, sides and top) must be non-combustible materials, metal studs,concrete board and concrete, brick,or stone.
Section 2: Framing
Installation
Installing The Fireplace Shell
The replace may be installed in a location that maintains clearances to ALL exterior furniture, appliances and other exterior equipment. Safety, as well as efciency of operation, must be considered when selecting the replace location. Try to select a location that does not interfere with foot trafc, has adequate ventilation, and offers an accessible pathway for ventilated gasses.
The replace dimensions with the Optional Stainless steel cover, shown below. (Note: This model is intended as a stand-alone).
25⅛”
40⅛" Width
Top View
35⅜" Opening
Framing (stand-alone):
For Fireplace without the Optional Stainless steel surround.
Combustible materials
36”
38”
40”
41”
Figure 3. Framing dimensions (without Optional surround). Must be back-
framed as shown in Figure 2a below.
23 7/8”
6¾"
37⅝"
25¾"
Opening
5¼"
40⅛" Width
Front View
Figure 2. Fireplace dimensions with insulation jacket
Page 6
XG0817 - 080311
Loading...
+ 14 hidden pages