www.montigo.com
Installation & Maintenance Manual
Check local codes and read all instructions prior to installation.
BF-Series SS Gas Fireplace
EPVRR Residential Roof PV System
EPVRR
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualied installer, service agency or the gas supplier.
Safety Notice:
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG1306 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 022813
Warning:
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas
supplier, call the re department.
• Installer: Leave this manual
with the appliance.
• Consumer: Leave this
manual for future reference.
EPVRR Residential Power Vent System
Read this manual before installing, operating or troubleshooting this
appliance. Please retain this owner's manual for future reference.
Power Vent Specications
Voltage: 110 Volts
Frequency: 50 Hz
Current draw: 1.41 Amp
Power consumption: 155 W
Speed: 2850 RPM
Maximum air movement: 400 CFM at zero restriction
Minimum air movement: 50CFM at 2.2" WC
Protection: Thermal switch
Bearings Ball bearings
The EPVRR dimensions:
Ø14”
191/4”
18”
Warning:
The power vent EPVRR can only be used with the following
R-Series Fireplaces:
R520N-I
R520L-I
R520STN-I
R520STL-I
R620N-I
R620L-I
R620STN-I
R620STL-I
MODEL
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Traditional Burner /
Logset
Linear Burner w/
Glass Accessories
Standing Pilot
Ignition
X 80,000 X X
X 65,000 X X
X 80,000 X X
X 80,000 X X
X 100,000 X X
X 80,000 X X
X 100,000 X X
X 100,000 X X
Honeywell Hot
Surface Ignition
SIT Electronic
Ignition
2”
81/2”
Ø1/2”
Front View
The EPVRRF Rough-in Frame dimensions:
6”
Ø 8”
14”
Front View
18”
18”
Top View
For installation instructions for the power vent EPVRR,
refer to the appropriate R-Series instruction guide
provided with the rebox.
CAUTION:
When cold air enters the warmer building interior, primarily at
the air intake end, condensation may occur on the exterior of the
pipe. To limit this condensation, install insulation over the last
twenty feet of pipe. Also, by sloping the last 20'-0" feet of pipe
downward toward the exterior of the building, elimination of most
of the condensation problems should occur. Ensure the termination is securely fastened, and sealed to the pipe. Fasten the
termination to exterior of the building with water tight sealant and
the appropriate fasteners.
Page 2
18”
Important:
All dimensions, and design specications are
subject to approval upon quotation of replace and associated equipment.