Check local codes and read all instructions prior to installation.
BF-Series SS Gas Fireplace
EDVWSPV Wall Power Vent System
EDVWSPV47
EDVWSPV58
Warning:
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualied installer, service agency or the gas supplier.
Safety Notice:
Glass doors on gas replaces are extremely hot while the replace is on and remain
hot even after the replace has been turned off. Safety screens are available and
can reduce the risks of severe burns.
Please keep children away from the replace at all times.
For Your Safety:
Do not store or use gasoline or other ammable vapors and liquids in the
vicinity of this or any other appliance.
XG1303 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 062010
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas
supplier, call the re department.
• Installer: Leave this manual
with the appliance.
• Consumer: Leave this
manual for future reference.
EDVWSPV Horizontal Power Vent System
Warning:
Read this manual before installing, operating or troubleshooting this appli-
ance. Please retain this owner's manual for future reference.
Safety Alert Key:
• DANGER!
Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
• Important: Used to address practices not related to personal injury.
Table Of Contents
Congratulations
Safety Alert Key
Table of Contents ..................................................................... 2
A. Termination Locations .......................................... 11
B State of Massachusetts / Amendment ................. 12
Motor Model Number: M2E068DF
Manufacturer : EBM Germany
Voltage: 110 Volts
Frequency: 50 Hz
Current draw: 1.41 Amp
Power consumption: 155 W
Speed: 2850 RPM
Maximum air movement: 400 CFM at zero restriction
Minimum air movement: 50CFM at 2.2" WC
Protection: Thermal switch
Bearings Ball bearings
All dimensions, and design specications are
subject to approval upon quotation of replace and associated equipment.
Specications
Important:
Page 2
Part No. XG1303 - 120110
Introduction
EDVWSPV Horizontal Power Vent System
CAUTION!
Due to its high operating temperatures, the appliance
should be located in a well ventilated area / space. See
the clearancespecications on Page 8.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other ammable materials should not be
placed on or near the appliance.
General Information
This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces that cannot be done with a standard Direct Vent gas replace
installation.
Also, read through the replace's Installation Operation and Maintenance Instructions, as it must also be adhered to.
Power Cord Harnesses:
EPVH10 -10 foot power cord and harness
EPVH20 -20 foot power cord and harness
EPVH30 -30 foot power cord and harness
EPVH40 -40 foot power cord and harness
EPVH50 -50 foot power cord and harness
EPVH60 -60 foot power cord and harness
EPVH70 -70 foot power cord and harness
EPVH80 -80 foot power cord and harness
EPVH90 -90 foot power cord and harness
EPVH100 -100 foot power cord and harness
Before You Begin
■ Minimum clearances 1” from vent to all combustible materials
must be maintained. Clearances listed in the replace’s Installation Operation and Maintenance Instructions supersede this
number.
Selecting and Installing the
Fireplace
When selecting a gas replace for use with the External Power Vent
System, take into consideration the various requirements and limitations in the venting installation section for the following models:
Models Equipped with Hot Surface Ignition (HSI)
It is recommended that this system be used with a gas replace
equipped with a Hot Surface Ignition System. Because there is not a
pilot in this system, there is more exibilty on venting requirements.
For example downward vertical vet runs are possible with an HSI
system, as outlined in the Venting Section.
Models Equipped with Millivolt/ Standing Pilot
If a standing pilot model must be used, then the millivot wiring harness must be installed, see the Wiring Section for more information.
Also, downward vertical vet runs are not possible with a standing pilot
system, as outlined in the Venting Section.
CAUTION:
Ensure Perforated Air Holes in the New Pipe Adapter / Restrictor
are not Covered when installing New Pipe Connection.
CAUTION:
When cold air enters the warmer building interior, primarily at the
air intake end, condensation may occur on the exterior of the ex
pipe. To limit this condensation, install insulation over the last
twenty feet of ex pipe. Also, by sloping the last 20'-0" feet of ex
pipe downward toward the exterior of the building, elimination of
most of the condensation problems should occur. Ensure the termination is securely fastened, and sealed to the ex pipe. Fasten
the termination to exterior of the building with water tight sealant
and the appropriate fasteners.
Part No. XG1303 - 120110
Page 3
EDVWSPV Horizontal Power Vent System
Dimensions
11 1/16"
11 1/16"
9 3/4"
REF.
Dimensions EDVWSPV47.
9 3/4"
10 9/16"
4
9.0
14 1/16"
14 1/4"
12 1/8"
1 1/2"
4 9/16"
7
9 11/16"
12 5/16"
Dimensions EPVF47 mounting frame for EDVWSPV47.
9 11/16"
4
Page 4
Part No. XG1303 - 120110
Dimensions
EDVWSPV Horizontal Power Vent System
11 1/16"
9.0
Dimensions EDVWSPV58.
10 9/16"
9 3/4"
11 1/16"11 1/16"
9.0
10 9/16"
5
5
14 1/16"
14 1/4"
12 1/8"
4 9/16"
8
9 11/16"
1 1/2"
Dimensions EPVF58 mounting frame for EDVWSPV58.
12 5/16"
9 11/16"
4