Monte Carlo Fan Company studio Owner's Manual

OWNER’S
MANUAL
Ceiling Fan Installation Instructions
© Copyright 2000 Monte Carlo Fan Co.
STUDIO...SERIES
Total fan wieght
READ AND SAVE THESE INSTRUCTIONS
Page 1 3SU54-CUL- ENG
INSTALLATION
Safety Tips
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards(ANSI/NFPA 70-1996), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacurer. If you have any questions contact the manufacturer.
3. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly dia­grams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 10 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support. And use mounting screws provided with the outlet box. (Mounting must support at least 35 lbs.)
9. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10.Attach the mounting bracket using only the hardware supplied with the outlet box.
11.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13.NEVER place a switch where it can be reached from a tub or shower.
14.The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15.Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
Unpack and inspect fan carefully to be certain all contents are included. Turn off power at fuse
1
box to avoid possible electrical shock.
Install mounting plate to outlet box in ceiling using the two 8-32 screws and washers provided with
3
© Copyright 2000 Monte Carlo Fan Co.
outlet box.
Use outlet box suitable for fan use. Secure outlet box directly to the building structure using ceiling joist screws (included). Outlet box
2
must be able to support 35 lbs.
Yolk Cover
Cotter Pin
Set Screws
Feed motor lead wires through downrod/ canopy assembly and insert downrod into motor yoke. Next, insert clevis pin through
yoke and downrod and secure with cotter pin. Tighten both yoke set screws to further secure downrod.
4
Slide down yoke cover.
Clevis Pin
Page 2 3SU54-CUL- ENG