Monte Carlo Fan Company Ceiling fan, Designer Supreme Owner's Manual

Page 1 – Designer Supreme-English CUL
OWNERS
MANUAL
Ceiling Fan Installation Instructions
For Designer Supreme Fans
READ AND SAVE THESE INSTRUCTIONS
92
Total fan weight
© Copyright 1998, Monte Carlo Fan Co.,REV.0, 9/18/98
INSTALLATION
Page 2 – Designer Supreme-English CUL
Safety Tips
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards(ANSI/NFPA 70-
1.
1993), including fire-rated construction. Use this unit only in the manner intended by the manufacurer. If you have any questions contact the manufacturer.
2.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
3.
one side of the outlet box and ungrounded conductor on the other side of the outlet box. Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being
4.
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
5.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the
7.
floor to the trailing edge of the blade. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support and use
8.
mounting screws and washers provided with the outlet box. (Mounting must support at least 35 lbs.) Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
9.
Attach the mounting bracket using only the hardware supplied with the outlet box.
10.
To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
11.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
12.
NEVER place a switch where it can be reached from a tub or shower.
13.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
14.
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NEPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched
15.
on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Phillips Screwdriver Wire Cutters Pliers Step Ladder
Unpack and inspect fan carefully to be certain all contents are included. (See
1
exploded view parts list.)
TOOLS REQUIRED
Turn off power at breaker box to avoid
2
possible electrical shock.
Cotter
Pin
Clevis
Pin
Set
Screws
Use outlet box suitable for fan support. Secure outlet box directly to the building structure using ceiling joist screws. Outlet
3
box must support 35 lbs.
Ridge
Ball Notch
Install mounting bracket to outlet box in ceiling using the screws provided with
4
the outlet box and washers.
Feed motor lead wires through downrod/ canopy assembly and insert downrod into motor yoke. Next, insert clevis pin through yoke and downrod and secure with cotter pin. (see inset) Tighten both yoke set
5
screws to further secure downrod.
Carefully lift fan assembly onto mounting bracket. Rotate fan so that the notch on the ball engages the ridge in the mounting bracket. This will allow hands-
6
free wiring.
© Copyright 1998, Monte Carlo Fan Co.,REV.0, 9/18/98