![](/html/f1/f12d/f12dc2eb72051d8fcf2ed913970978aca9d821a65e1c8600a5f2885b817d8dd9/bg1.png)
Owner’s Guide and Installation Manual
3MAVR70XXD Series Fan
CUL Model NO. : 3MAVR70XXD
Attach sales receipt to this card and retain as your proof of purchase
DATE OF PURCHASE:
MODEL NUMBER:
To register your fixture, please visit our website www.montecarlofans.com
RETAILER NAME:
RETAILER ADDRESS:
6 kgs
13.2 lbs
Total fan weight with light
![](/html/f1/f12d/f12dc2eb72051d8fcf2ed913970978aca9d821a65e1c8600a5f2885b817d8dd9/bg2.png)
Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of
15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.
WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do
not insert foreign object between rotating blades.
CAUTION: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the
building structure (or the ceiling joist).
Attach the mounting bracket using only the hardware supplied with the outlet box.
WARNING: To Reduce The Risk Of Electric Shock, This Fan Must Be Installed With a general use, isolating Wall Control/Switch.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. BFR-G4D99910G1
manufactured by Chungear Industrial Co. Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable
speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is
required, the product should be returned to an authorized service facility for examination or repair.
All set screws must be checked, and re-tightened where necessary, before installation.
Note: Suitable for use in damp locations.
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
© 2018 Monte Carlo Fan Company
Customer Service
800-969-3347
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.montecarlofans.com
2
10/2017
![](/html/f1/f12d/f12dc2eb72051d8fcf2ed913970978aca9d821a65e1c8600a5f2885b817d8dd9/bg3.png)
1 2 3
Ceiling
ON
ON
OFF
OFF
Ceiling
Joists
2˝ x 4˝
Outlet
Box
Ceiling joist
Mounting
Bracket
Outlet Box
Screw/ Washers
/Spring Washers
Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
Use AC 120V/60HZ power supply
only.
Before installing this fan makes sure the
outlet box is properly installed to the
house structure. Ensure the outlet box is
securely fastened by at least two points
to a structural ceiling member (a loose
box will cause the fan to wobble).
To reduce the risk of fire, electric shock,
or personal injury, mount to outlet box or
supporting system acceptable for fan
support.
(Mounting must support at least 35 lbs.)
4 5 6
SAFETY CABLE INSTALLATION
Safety cable
Lag screw
Safety cable
Washer
Lock washer
Junction
Box
Mounting
Bracket
Blade bracket
p
u
e
d
i
s
s
i
h
T
This side up
Blade
Blade rubber plug
Set screw
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35
lbs). Remove the two outlet box screws
provided with the box, aligning the holes
of the mounting bracket with the holes of
the outlet box. Reinstall the 2 outlet box
screws securely.
This side up
Blade bracket
Blade assemby
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 3” lag screws,
washers and lock washers provided.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
© 2018 Monte Carlo Fan Company
Note: Make sure the side with a label
“This side up” is installed upward.
Aligning the holes on blade and the screw
holes on blade bracket as shown in
illustration, and then partially install the
set screws with blade rubber plug.
Screws provided. Tighten screws
securely after 2 set screws are installed.
Repeat this process for remaining blades.
Caution: Make sure the blade rubber
plug is in position.
3
Place motor assembly on a suitable area
of bottom Styrofoam for installation of
blade assembly.
Aligning the holes on blade bracket with
the screw holes on the motor, and then
partially install blade assembly onto the
motor with set crews provided.
Repeat this process for remaining blade
assemblies.
Tighten all set screws securely after
all the blade assemblies are installed
to motor.
Note: For precise installation of blade
bracket with motor, the set screws are
made with a little interference fit. It is a
normal condition.
10/2017
![](/html/f1/f12d/f12dc2eb72051d8fcf2ed913970978aca9d821a65e1c8600a5f2885b817d8dd9/bg4.png)
7 8 9
Downrod
Keeper
pin
Cross
pin
Yoke
Partially loosen downrod set screws from
yoke at top of motor assembly.
Remove preassembled cross pin and
keeper pin from downrod. Keep parts.
Canopy
Canopy ring
Yoke cover
Downrod
Place downrod over canopy, canopy ring
and yoke cover.
Thread lead wires and safety cable from
motor assembly through downrod.
Screwdriver
Cross pin
For easy installation of cross ping on next
step.
Carefully insert a phillips screwdriver through
yoke and downrod (don’t damage the lead
wires) as a guide and then push the cross
pin and pull the screwdriver in the meantime
as shown in illustration.
10 11 12
Mounting bracket
Tab
Keeper pin
Slip downrod into motor yoke, aligning
holes and install cross pin and keeper pin.
Insert cross pin through yoke and downrod
until point appears on the other side, and
insert keeper pin on cross pin.
Pull the downrod up tight against the
cross pin, and then evenly tighten the
downrod set screws on motor housing
yoke.
Place yoke cover on top housing of fan.
Warning: Cross pin and keeper pin must
Cross pin
Slot
Hanger ball
Install ball end of downrod into mounting
bracket opening. Align (engage) slot on
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with
tab may result in serious injury.
Important: If using the angle mount,
make sure open end of mounting bracket
is installed facing the higher point of the
ceiling and make sure the ceiling angle is
not steeper than 15º.
be installed securely, failure to install them
will result in serious injury.
Attach Safety
Cable to Ceiling
Support Cable
Tab
Safety cable from fan
Set screw
Cable clamp
Connect the safety cable from fan to the
Ceiling support cable.
Slide cable clamp onto the safety cable
from fan. Place the end of cable through
the loop of ceiling support cable and then
feed end of cable into clamp hole and
firmly tighten set screw. Cut off excess
safety cable.
Make sure that when the safety cable is
fully extended the lead wires are longer
than the cable and no stress is placed on
the lead wires.
© 2018 Monte Carlo Fan Company
4