Montague SP2035 Specifications

Item No. ___________________________
Project ___________________________
Quantity ___________________________
Heavy-Duty Gas Stock Pot Stoves
SP2035 or SP2053
MODEL GUIDE
Model No. Burners BTU Input
SP2035
1 35,000
Model SP2053
SP2053
STANDARD WARRANTY:
• One Year, Parts & Labor
AGENCY APPROVALS
• NSF Listed
• CSA Design Certified to ANSI Z83.11, CSA 1.8
1 53,000
SHORT/BID SPECIFICATION
Stock Pot Range shall be a Montague Legend Heavy Duty Model:
M
SP20__ [Specify: 35(35,000) or 53(53,000) BTU/hr]…gas-fired unit
with one heavy-duty banjo-burner (35) or a two-ring burner (53) with manual control valve and standing pilot; heavy cast iron top grate with machined top surface; stainless steel front, sides and 6” (152 mm) legs; plus all the features listed and options/accessories checked:
BURNERS & CONTROLS:
SP2035 — One 35,000 BTU/hr cast iron banjo-type burner
SP2053 — One 53,000 BTU/hr cast iron two-ring burner
• Individually raised burner ports to prevent clogging
• Dependable manual gas control valve [two for ring burner]
• Standing pilot for automatic ignition
STANDARD CONSTRUCTION FEATURES:
• Satin finish stainless steel front, sides and back
• Heavy-Duty one piece, cast iron top grate with surface-ground raised ribs
• Other surfaces painted black with electrolytic zinc undercoating
• 6-1/2” (165 mm) high stainless steel legs with height-adjustable feet
• 1/2” NPT rear gas connection
THE MONTAGUE COMPANY 1830 Stearman Avenue, Hayward, CA 94545 800 345-1830 Fax: 510 785-3342 montaguecompany.com
HDS-41 [Rev. 10/10]
Item No. ___________________________
Project ___________________________
Heavy -Duty Gas Stock Pot Stoves
SP2035 or SP2053
OPTIONS GUIDE:
General:
M
Black with stainless steel valve panel
Note: Not available with casters.
INSTALLATION REQUIREMENTS & SHIPPING INFORMATION
1. Stock Pot Range must be installed in accordance with local codes or in their absence with
the National Fuel Gas Code: ANSI Z223.1. Compliance with codes is the responsibility of the Owner and Installer.
2. An adequate ventilation system is required. Refer to National Fire Protection Association
Standard No. 96, “Vapor Removal from Cooking Equipment.”
3. This appliance is intended for commercial use by professionally trained personnel.
NOT intended for Residential Use.
4. Specify installation elevation: _____________ if above 2000 feet (610 m).
5. GAS INLET SIZE (All Models): 1/2” NPT right-rear gas inlet. 1/2” NPT gas pressure
regulator is provided and must be installed (by others) when unit is connected to gas supply.
6. The incoming gas line pressure into the regulator should be 8”-14” w.c. for natural gas,
and 12”-14” w.c. for propane gas.
Quantity ___________________________
Dimensions in brackets are millimeters
Minimum
Clearances
Combustible Construction
Noncombustible
Construction
From Back Wall 6” (152 mm) 0
Left & Right Side 6” (152 mm) 0
With 6” (152mm) Legs
Suitable for installation on
combustible floors
Specify Type of Gas:
Manifold Pressure: 6.0” WC 10.0” WC
Models: Burners BTU/hr (kW) BTU/hr (kW)
SP2035 SP2053
1 35,000 (10.3) 35,000 (10.3) 84 lbs (38 kg) 85 7/.2 1 53,000 (15.5) 53,000 (15.5) 90 lbs (41 kg) 85 7/.2
M Natural M Propane
1830 Stearman Avenue, Hayward, CA 94545 800 345-1830 • Fax: 510 785-3342 www.montaguecompany.com
Shipping
Weight
Shipping
Class
Entry clearance 20” (610 mm) uncrated
Cube
(Crated)
3/m3
ft
Due to continuous product improvements, specifications are subject to change without notice.