Montague C12-8 Specifications

Item No. ___________________________
Project ___________________________
Heavy-Duty Gas
12-36” Counter-Top Griddle
Model No. Overall Width
C12-8T
C12-8
C18-8T
C18-8
C24-8T
C24-8
C36-8T
C36-8
Quantity ___________________________
MODEL GUIDE*
Controls
Type Number
12” (305 mm) Thermostat 1
12” (305 mm) Manual 1
18” (457 mm) Thermostat 1
18” (457 mm) Manual 2
24” (610 mm) Thermostat 1
24” (610 mm) Manual 3
36” (914 mm) Thermostat 2
36” (914 mm) Manual 4
*For wider models see specification sheet HCG-4B
Model C24-8 shown
SHORT/BID SPECIFICATION
Counter-top Griddle shall be a Montague Legend Add-A-Unit Model: C___
[Specify width: 12” (305 mm), 18”(457 mm), 24” (610 mm) or 36” (914 mm)] -8 [for Manual Control(s)] or -8T [for Thermostat Control(s)], unit with a 3/4” (19 mm) thick precision ground cook surface, 4” (102 mm) high rear splash and tapered side splashes, 2-5/8” (67 mm) wide front grease trough with drop to grease drawer and 15,000 BTU/hr or 20,000 BTU/hr (-T Models) burner(s); with stainless steel front, sides and exterior bottom, 4” (102 mm) high flue riser and 3” (76 mm) deep front rail standard; plus all the features listed and options/accessories checked:
STANDARD GRIDDLE FEATURES:
• 3/4” (19 mm) thick precision-ground steel cook surface
• 4” (102 mm) high backsplash and tapered side-splashes
• 2-5/8” (67 mm) wide front grease trough pitched to the grease drop
• Bottom-mounted, slide-out 1-gallon capacity grease drawer - grease can on 12” models
• Standard 15,000 BTU/hr gas burners with standing pilot(s) & gas control valve(s)
• 20,000 BTU/hr gas burner(s) [-T Models] with: thermostat control(s)
• Adjusting bolts for changing griddle plate forward pitch
• Standard has 28” deep frytop
STANDARD BASE CONSTRUCTION:
• Satin finish stainless steel front and sides with 3” (76 mm) deep front rail
• Other surfaces painted black with electrolytic zinc undercoating
• Stainless steel 4” (102 mm) rear flue riser standard
• 4” (102 mm) height-adjustable stainless steel legs standard
• 1-1/4” front gas manifold with 1/2 union on each end
STANDARD WARRANTY:
• One Year, Parts & Labor
AGENCY APPROVALS
• NSF Listed
• ETL Design Certified to ANSI Z83.11
HDCS-10 [Rev. 10/10]
THE MONTAGUE COMPANY 1830 Stearman Avenue, Hayward, CA 94545 800 345-1830 Fax: 510 785-3342 montaguecompany.com
Item No. ___________________________
Heavy-Duty Gas
12-36” Counter-Top Griddle
OPTIONS GUIDE:
General:
M
42” (1062 mm) Griddle Depth [Add Suffix -40]
M
4” (102 mm) special base with grease drawer [M Prefix]
M
Equipment Stand [Consult Factory]
Security Options/Prison Package [Consult Factory]
Finish:
M
Stainless steel back panel
M
18” (547 mm) high riser
M
6” (152 mm)wide stainless steel plate shelf
M
8” plate shelf
M
Exterior stainless steel bottom
Special finish options [Consult Factory]
Griddle/Fry Top:
M
1” (25 mm) thick griddle plate
M
1” (25 mm) thick grooved griddle plate
M
1” Chrome griddle (thermostats required)
M
34” (687 mm) deep plate [Add Suffix -40] (STD
depth 28”)
M
Thermostatically controlled [Add Suffix -T]
M
450° or 550° thermostat options
Project ___________________________
Quantity ___________________________
Dimensions in brackets are millimeters
Manifolds:
[Specify left or right rear with pressure regulator]:
M
1” NPT
Manifold Cap:
M
left side M right side
Stainless Manifold Cover:
M
left side M right side
INSTALLATION REQUIREMENTS & SHIPPING INFORMATION
1. Griddle must be installed in accordance with local codes or in their absence with the
National Fuel Gas Code: ANSI Z223.1; Natural Fuel Gas Code: CAN/CGA-B149.1 or Propane Installation Code: CAN/CGA-B149.2, as applicable. Compliance with codes is the responsibility of the Owner and Installer.
2. An adequate ventilation system is required. Refer to National Fire Protection Association
Standard No. 96, “Vapor Removal from Cooking Equipment.”
3. This appliance is intended for commercial use by professionally trained personnel.
NOT intended for Residential Use.
4. Specify installation elevation: _____________ if above 2,000 ft (610 m).
5. GAS INLET SIZE (All Models): 1-1/4 (32mm) front manifold with 1/2 union on each end
provided for battery connection. A properly sized gas pressure regulator must be furnished by the Installer.
6. The incoming gas line pressure into the regulator should be 8”-14” w.c. for natural gas,
and 12”-14” w.c. for propane gas.
Specify Type of Gas:
Manifold Pressure: 6.0” WC 10.0” WC
Models: Burners BTU/hr (kW) BTU/hr (kW)
C12-8T
C12-8
C18-8T
C18-8
C24-8T
C24-8
C36-8T
C36-8
1 20,000 (5.9) 20,000 (5.9) 190 lbs (86 kg) 85 4/.1 1 15,000 (4.4) 15,000 (4.4) 190 lbs (86 kg) 85 4/.1 2 40,000 (11.7) 40,000 (11.7) 240 lbs (109 kg) 85 7/.2 2 30,000 (8.8) 30,000 (8.8) 240 lbs (109 kg) 85 7/.2 3 60,000 (17.6) 60,000 (17.6) 310 lbs (140 kg) 85 9/.25 3 45,000 (13.2) 45,000 (13.2) 310 lbs (140 kg) 85 9/.25 4 80,000 (23.4) 80,000 (23.4) 432 lbs (196 kg) 85 14/.4 4 60,000 (17.6) 60,000 (17.6) 432 lbs (196 kg) 85 14/.4
M Natural M Propane
Minimum
Clearances
Combustible Construction
Noncombustible
Construction
From Back Wall 2” (51 mm) 0”
Left & Right Side 6” (152 mm) 0”
With or without 4” (102 mm) legs
Shipping
Weight
Suitable for installation
on non-combustible counters ONLY
Shipping
Class
Cube
(Crated)
3/m3
ft
Due to continuous product improvements, specifications are subject to change without notice.
1830 Stearman Avenue, Hayward, CA 94545 800 345-1830 • Fax: 510 785-3342 www.montaguecompany.com
HDCS-10 [Rev. 10/10]
Loading...