Montague 136LB-UFLC-36R Operator’s Manual

INSTRUCTION MANUAL
Addendum
MONTAGUE
Gas Fired Heavy Duty Counter,
Standard, and Convection Ranges
with Electronic Ignition
Models:
C12, C18, C24 & C36 Series
M12, M18, M24 & M36 Series
124, 136 & V136 Series
These instructions should be read thoroughly before attempting installation.
Set up and installation should be performed by qualified installation personnel.
Keep area around appliances free and clear from combustibles.
PLEASE RETAIN THIS MANUAL
FOR FUTURE REFERENCE.
THE MONTAGUE COMPANY
1830 Stearman Avenue P.O. BOX 4954
HAYWARD,CA 94540-4954
TEL: 510/785-8822 FAX: 510/785-3342
CONTENTS
INSTALLATION ………………. 1 MAINTENANCE…………… 6 OPERATION……………...……. 4 SERVICE…………………... 7
IMPORTANT
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the operating and maintenance instructions thor­oughly before installing or servic-
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
ing this equipment.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
SHIPPING DAMAGE CLAIM PROCEDURE
For your protection, please note that equipment in this shipment was carefully inspected and packed by skilled personnel before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of this shipment.
If shipment arrives damaged:
1. VISIBLE LOSS OR DAMAGE—Be certain this is noted on freight bill or express receipt, and signed by person making delivery.
2. FILE CLAIM FOR DAMAGES IMMEDIATELY—Regardless of the extent of damage.
3. CONCEALED LOSS OR DAMAGE—If damage is unnoticed until merchandise is un- packed, notify transportation company or carrier immediately, and file ―concealed dam­age‖ claim with them. This should be done within fifteen (15) days of date that delivery was made to you. Be sure to retain container for inspection.
We cannot assume responsibility for damage incurred in transit. We will, however, be glad to furnish you with necessary documents to support your claim.
2
INSTALLATION
The Montague gas ranges are manufactured for use with the type of gas indicated on the name­plate.
The Montague heavy duty gas convection oven type ranged are produced with the best possible material and workmanship. PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-TREE OPERATION.
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF
Qualified installation personnel are individuals, a firm, corporation, or company which either in person, or through a representative are engaged in, and are responsible for:
A. The installation or replacement of gas piping or the connection, installation, repair, or servicing
B. The installation of electrical wiring from the electric meter, main control box, or service outlet to
QUALIFIED INSTALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION
OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN
DAMAGE TO THE RANGE AND/OR INJURY TO THE OPERATOR.
of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all requirements of state or local authorities having jurisdiction. Reference: National Fuel gas code Z223.1-1984, Section 1.4.
the electric appliance. Qualified installation personnel must be experienced in such work, be familiar with all precautions required, and have complied with all requirements of state and local authorities having jurisdiction. Reference: National Electric Code, ANSI/NFPA No. 70-1984.
READ CAREFULLY AND FOLLOW THESE INSTRUCTIONS
THE RANGE(S) MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE ANSI A223.1-1984, INCLUDING:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig. (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig. (3.45kPa)
THE UNIT WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES, OR IN ABSENCE OF LOCAL CODES, WITH
THE NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70-1984.
PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT.
3
INSTALLATION
ELECTRICAL CONNECTION
Unless otherwise specified, the range is equipped with a 6 ft. flexible supply cord for 115 VAC, 60 Hertz. A terminal block is provided for 208-240 VAC, 60 or 50 Hertz, single phase units. The wiring diagram is located on the back of the range.
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES, WITH THE NATIONAL ELECTRIC CODE,
ANSI/NFPA NO. 70-1984.
1. 115 VAC—60 Hz—Single Phase
Ranges with this electrical rating are factory supplied with a three-wire cord and three– prong plug which fits any standard three-prong grounded receptacle. A separate 15 amp. supply is needed for each oven.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS:
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT
CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
II. 208-240 VAC—60 Hz–Single Phase (2 Wire)
Ranges with this electrical rating are factory supplied with a terminal block. To connect supply wires, remove cover from connection box at right rear of range. Route supply wires and ground wire through hole with strain relief fitting at top of connection box. Attach ground wire to ground wires to proper terminal block. Attach ground wire to ground lug inside connection box. See wiring diagram for proper connections.
III. 220 VAC– 50Hz– Single Phase (2 Wire)
Follow steps outlined in (II.) above, refer to wiring diagram for proper connection.