Monoxivent 1500, 15076, 15106, 15146 Maintance Manual

1500 Series Exhausting Arm ­Wall Mount Models: 15076/15106/15146
MONOXIVENT - SOURCE CAPTURE SYSTEMS
1306 Mill St., Rock Island, IL 61201
877-608-4383 - info@monoxivent.com
monoxivent.com
15000 Series Exhausting
Assembly Information
Receiving
Check all packages for shipping damage. If damage is found then you as the receiver must note the damage at the time of receipt or contact the carrier and file a damage receipt claim. As the receiver,
this is your responsibility.
General information for the 15000 arm wall/column mounting
There will be some assembly required for the arm, elbow, and mounting bracket. Please check for all components before starting.
1. Check all components for wall/column mount arm.
1. Black steel wall/column mount bracket
2. Swivel 90 degree elbow with mounted nylon pivot ring
Arm - Wall Mount
3. Steel 360 degree clam with rubber seal
4. Arm complete with hood, hose, and base
5. Duct connection flange or direct mount fan
2. Select desired mounting location. Be sure to inspect the structure where the arm is to mount. Structure should be secure and solid.
3. First take the mounting bracket and be sure to bolt solid to support structure. Be sure and make bracket square using levels.
4. Slide hose away from the white base bracket. Please note there is a bolt with a red-painted head. This bolt is in a hole marked 2. Remove this bolt and pivot the white bracket 90 degrees so the hole marked 1 will line up with the hole in the bracket. Now replace the red bolt and nut and bring to a snug fit. (see attached drawing)
5. Attach the 90 degree elbow to the white arm bracket. Note the elbow and the white bracket have small mating flanges. There is a rubber gasket that seals the flanges of the elbow and white bracket. Install the steel metal clamp over the rubber gasket and flanges. Be sure that the elbow and arm
are in perfect vertical position before tightening clamp.
6. With assistance, mount the assembled arm and elbow to the mounting bracket. The elbow has
a mounted 8-hole black nylon swivel collar. Locate and bolt the arm, elbow, and black nylon collar to the bracket by the 8 holes. Snug the bolts to hold the elbow to the mounting bracket. Do not over tighten bolts. Be sure elbow/arm swivel freely at the bracket.
1306 Mill St., Rock Island, IL 61201
877-608-4383
info@monoxivent.com
monoxivent.com