Note: Read entire instruction sheet before you start installation and assembly.
WARNING
Be sure to read this entire manual thoroughly and you fully understand all the instructions and warning before
attempting to begin your installation.
This product should only be installed by someone who has a basic knowledge of buiding construction,in stallations
and fully understands these instructions.
Make sure that the supporting surface will safely support the combined load of the mount, the display and all
attached hardware and components.
This wall bracket will only support flat panel displays(LCD,Plasma).The maximum load capacity is 80 pounds.
If mounting to a wall of wood stud construction, be sure that mounting bolts are anchored to the center of the
studs.
Always have someone assist you to lift and position your equipment.
Tighten screws and bolts firmly, but do not over tighten. Over tightening can damage the items and greatly reduce
their ability to hold. Please refer to suggested torque values where applicable in these instructions.
Tools Needed for Assembly
stud finder ("edge to edge" stud finder is recommended)
phillips screwdriver
pencil
drill
3/16"(4mm) drill bit for wood studs, 1/4"(6mm)( drill bit for concrete
level
tape measure
Table of Contents
Parts List .......................................................................................................................................................................... 3
Installation to Single Wood Stud Wall ................................................................................................................................... 4
Installation to Solid Concrete and Cinder Block .................................................................................................................... 5
Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
A
Using a stud finder, locate and mark the edges of the wood stud. Use of an edge to edge stud finder is highly
recommended. Use a level to draw a vertical line down the center of the stud. Use AA as template to
mark center of holes along the vertical line.
to wall using
two M6 X 60 hexagonal screws (
STUD
Drill three 1/8" (4 mm) dia. pilot holes 2" (50 mm) deep. Attach AA
) as shown in fig. A.2. Level plate, then tighten all fasteners.
H
AA
H
fig. A.1
STUD
AA
fig. A.2
4 of 8
Page 5
Installation to Solid Concrete or Cinder Block
WARNING
When installing the wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
B
Use wall plate (AA) as template to mark mounting
holes.
Drill three 1/4" (6 mm) dia. holes 2" (70 mm) deep as
shown in fig. B.1. Insert concerte anchor (
wall as shown (right). Place wall plate over anchors and
secure with M6x 60 cross slotted head screw (
fasteners.
) in holes flush with
H
WARNING
Tighten hex head bolts
is firmly attached,but do not overtighten. Overtightening
can damage the screws, greatly reducing their holding
power.
so that wall arm assembly
WARNING
Always attach concrete anchors directl to load-
bearing concrete.
Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finishing
surface is unavoidable, the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
y
1
H
Drill holes and insert anchors (F).
concrete
surface
H
2
H
Place wall plate (D) over anchors (F) and secure with screws (E).
H
3
Tighten all fasteners.
solid concrete
H
H
r
cinde
block
CUTAWAY VIEW
wall plate
plaster/
dry wall
INCORRECT
concrete
wall plate
plaster/
dry wall
CORRECT
concrete
AA
fig. B.1
5 of 8
Page 6
Attaching AA to Screen with VESA® Mounting Pattern
Choose hole pattern as shown in detail 3 for VESA mounting pattern. Begin with the shortest length screw, hand thread
C
through adapter plate into screen as shown in detail 4. Screw must make at least three full turns into the mounting hole
and fit snug into place. Do not over tighten. If screw cannot make three full turns into the screen, select a longer length
screw from the fastener pack. Repeat for remaining mounting holes. Securely tighten screws.
NOTE: Spacers may not be used, depending upon the type of screen.
Mounting Patterns
VESA
VESA
®
200 x 200
®
200 x 200
ADAPTER
PLATE
SCREE
VESA
N
®
200 x 100
VESA
NOTE: For screens with a hole
pattern in a pocket,
spacers go between
adapter plate and
screen.
®
VESA
®
100 x 100VESA® 75 x 75
DETAIL 3
200 x 100VESA® 100 x 100
DETAIL 4
6 of 8
Page 7
For Flat Back Screen
C.1
fig C.1.1fig C.1.2
SCREEN
SCREW
SCREEN
SPACER
OR
Front PlateFront Plate
Select the small,medium,large or extra large screws from the screw package .Fastener pack then
attach screen brackets(AA) to screen following figure C.1.1 or C.1.2 on page 7.
C.2
After the locked front plate is hanging on the wall panel ,
use a M4x12 philips pan head to fix these two
parts.
Be careful when you operate this bracket,or you may
damage your screen.
SCREW
WARNING
Do
not lift more weight than you can handle. Use
additional man power or mechanical lifting equipment
to safely handle placement of the screen.
CAUTION
Do not tighten screws with excessive force.
Overtightening can cause damage to mount.
fig.C.2.1
7 of 8
Page 8
Adjust tension knob on side of mount as shown infig.
D
D.1to desired tension to balance your screen size
and weight.
The tension knob, without changing the bracket tension,
can be pulled out, away from the bracket and turned
independently of the knob post for readjustment as
shown in
Push or pull from top or bottom of screen to adjust
tilt as shown. The tilt can be adjusted to a maximum
of -5° forward or +15°backward.
fig.D.2.
CAUTION
Be careful not to pinch fingers when opening and
closing mount from the wall.
fig. D.2
fig. D.1
E
Cable Management
Note: Make sure cords have enough slack to allow
full movement of the arm. Route cords inside
arm slots of
in fig.E.1.
has been omitted from the image.
wall arm assembly (AA) as shown
For demonstration purposes, the wall
fig.E.1
WARNING
Do not remove or loosen screw while the mount is in use. Doing so may cause the
8 of 8
screen to fall.