Monogram ZWL1126SJSS Specifications

MONOGRAM 1.2 CU. FT. DRAWER MICROWAVE ZWL1126SJSS
ZWL1126SJ
OVERALL DIMENSIONS
23 7/8" (60.6) 22 1/8" (56.2)
min cutout width
23 1/8" (58.7)
17 7/8" (45.4)
SIDE VIEW
21 5/8"
(54.9)
16 15/16"
TOP VIEW
(43.0)
4"
(10.2)
8 5/16"
(21.1)
3 3/32"
3"
(7.6)
12 11/16"
(32.2)
(7.9)
1 3/4"
(4.4)
21 7/8"
(55.6)
Overall Width
Overall Height
Overall Depth
Oven Door Clearance
Overall Oven Interior Capacity
Oven Interior Dimensions (W x H x D)
Minimum Cabinet Width*
Minimum Cabinet Depth*
Minimum Base Support
Cutout Width* 22 1/8" (56.2 cm) Min
Cutout Height*
Cutout Depth*
Volts/Hertz/Amps 120 VAC, 60 Hz
Cord Length 47 1/4" (119.4 cm)
Electrical Rating
Total Amps
Shipping Weight
23 7/8" (60.6 cm)
15 15/16" (40.5 cm)
23 1/8" (58.7 cm)
15" (38.1 cm) Min
1.2 cu. ft. (.02 cu. cm)
16 1/4" x 7 1/4" x 16 1/4" (41.3 cm x 18.4 cm x
41.3cm)
23 7/8" (60.6 cm)
23 1/2" (59.7 cm)
110 lbs (49.9 kg)
14 13/16" (37.6 cm) Min
23 1/2" (59.7 cm) Min
1.67 kw@120v
15
90 lbs (39.4 kg)
1 1/16"
(2.7)
14 13/16"
(37.6)
min cutout
height
1/16"
(0.2)
1 1/4" (3.2)
15 15/16"
(40.5)
1 1/8"
(2.9)
4"
(10.2)
FRONT VIEW (SHOWING CUTOUT OVERLAP)
4 11/16"
(11.9)
*Additional space will be needed for flush installation.
ATTENTION ELECTRICIAN:
A 120VAC, 60Hz, 20 Amp circuit is required. An individual properly grounded branch circuit or circuit breaker is required. Hard wired junction box is required for built-in product.
1 1/4"
(3.2)
Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimensions may vary due to manufacturing tolerances.
OPEN DRAWER
SHOWING CLEARANCE
Product Specification Revised 1/18
15"
(38.1)
MONOGRAM 1.2 CU. FT. DRAWER MICROWAVE ZWL1126SJSS
ZWL1126SJ
STANDARD INSTALLATION
SIDE VIEW
23 1/2"
(59.7) min depth
ZWL1126SJ
NOTES
STANDARD INSTALLATION
A
Junction box location
(May also be located in adjacent cabinet.)
To reduce the risk of
B
tipping of the drawer, the Anti-Tip block must be properly installed located 14-13/16" above the floor on which the Microwave Drawer will sit. The Anti-Tip block must be provided and pre-installed by the purchaser of the product or builder before install can be done. The Anti-Tip block prevents serious injury that might result from spilled hot liquids.
Cleats may be visible
C
and should be finished to match cabinetry.
D
The face of the shelf
must sit 1-7/8" back from the face of the cabinet. See installation instructions for further details including the installation of 24" flush mount deflector vent.
FLUSH INSTALLATION
(10.2)
A
14 13/16"
(37.6) cutout height
18 1/2"
(47.0)
STANDARD INSTALLATION
4"
5"
E
(12.7)
22 1/8" (56.2) min
cutout width
FRONT VIEW
B
23 1/2"
(59.7) min depth
STANDARD INSTALLATION
SIDE VIEW
4"
(10.2)
A
5"
E
16 7/8"
TOP VIEW
1 3/16"
(3.0)
Side cleat
22" (55.9) mounting
cleat opening width
FLUSH INSET INSTALLATION
(42.9)
min cutout
height
16 7/16"
(41.8)
FLUSH INSET INSTALLATION
TOP VIEW
For more details, refer to the installation instructions for this product on Monogram.com. Dimensions in parentheses are in centimeters unless otherwise noted.
(12.7)
24 3/16" (61.4) min
24 1/2" (62.2) max
FRONT VIEW
cutout width
3/4" Shelf
(1.9)
B
D
FLUSH INSET INSTALLATION
23 1/2"
(59.7) min depth
SIDE VIEW
C
Product Specification Revised 1/18
Loading...