Installation
Instructions
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
ZV950
36" Stainless Steel
Vent Hood
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT– Save these instructions
for local inspector’s use.
• IMPORTANT – Observe all governing codes
and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
•
Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
• Skill Level – Installation of this appliance requires basic
mechanical and electrical skills.
• Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1.800.561.3344.
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of these vent hoods, and
to reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes, et pour
réduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION CORRECTEMENT.
WARNING:
To reduce the risk of re or electrical shock, do not use
this range hood with any external solid-state speed control device. Any such alteration from original
factory wiring could result in damage to the unit
and/or create an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur
de vitesse électronique externe. Toute modication
de ce type du branchement d’usine peut endommager
l’appareil ou créer un risque de choc électrique.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch
power o at the service panel and lock service
panel to prevent power from being switched on
accidentally. If the service panel cannot be locked,
fasten a tag or prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES
RÈGLES SUIVANTES :
A. Utiliser cet appareil uniquement de la manière
prévue par le fabricant. En cas de question,
consulter le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour éviter la mise
sous tension accidentelle. S’il n’est pas possible de
verrouiller le panneau du disjoncteur, attacher un
placard ou une étiquette très visible au panneau.
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical
wiring must be done by qualied person(s) in
accordance with all applicable codes and standards
including re-rated construction.
• Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guidelines
and safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
• Local codes vary. Installation electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical Code
ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of re and to
properly exhaust air, be sure to duct air outside–Do not
vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces or garages.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
PRUDENCE–Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque
d’incendie et pouvoir évacuer l’air correctement.
Il ne faut pas évacuer l’air dans l’espace entre les parois
d’un mur, un plafond ou un grenier, un espace sanitaire
ou un garage.
2
Design Information
10"
*Height
to Ceiling
35-5/8"
25"
Installation
Height Depending
on Ceiling Height
36" Min.
CONTENTS
Design Information
Product Dimensions and Clearances .......................................3–4
Optional Accessories ............................................................................4
Installation Preparation
Advance Planning,
Ductwork, Framing ..............................................................................5
Power Supply ............................................................................................5
Duct Fittings ..............................................................................................6
Tools and Materials Required ...........................................................7
Remove the Packaging ........................................................................7
Check Installation Hardware .............................................................8
PRODUCT DIMENSIONS AND CLEARANCES
36" Vent Hood Installation Combinations
This Stainless Steel Hood can be installed over any Monogram cooktop, including the Professional 36" rangetop and
30" or 36" range.
Ductwork, Wiring Locations ..............................................................8
Installation Instructions
Step 1, Install Framing for Hood Support ....................................9
Step 2, Install Mounting Brackets ...................................................9
Step 3, Install Duct Bracket ............................................................. 10
Step 4, Install the Hood ..................................................................... 10
Step 5, Connect Ductwork ............................................................... 11
Step 6, Connect Electrical ................................................................ 11
Step 7, Install Duct Covers ............................................................... 11
Step 8, Install Filters ............................................................................ 12
Step 9, Finalize Installation .............................................................. 12
Cooking surface to bottom of hood should be:
• 25-1/2" max. for 8 ft. ceiling height.
• 25-1/2" to 30" for 9 ft. ceiling height.
• 30" min. for 10 ft. ceiling height.
Plan the installation height carefully to avoid unsightly
gaps above the hood.
*The supplied duct cover ts 8 ft. to 10 ft . ceilings.
The vent hood must be installed 24" min. and 30" max.
above the cooking surface. The hood installation height,
from the cooking surface to the bottom of the hood, depends upon ceiling height.
This hood must be installed 30" min. above a Monogram
Professional Cooktop or Range. Ceiling height for this installation combination must be at least 8'5" high.
Note: The supplied 2-piece duct cover is adjustable to t 8
ft. to 10 ft. ceilings. For ceiling heights greater than
10 ft. and up to 14 ft., order ZX14SDSS stainless steel duct
cover accessory.
ZV950SDSS Duct Cover
Dimensions
ZX14SDSS Duct Cover
Dimensions
3
Design Information
PRODUCT DIMENSIONS AND CLEARANCES (cont.)
Using Duct Cover Accessories
A Duct Cover Accessory may be required for your hood
installation height. Use this chart to determine installation height and accessory for your ceiling height.
ZV950SDSS Installation Heights
Actual
Ceiling
Height
7' 11"
8' 0"
8' 1"
8' 2"
8' 3"
8' 4"
8' 5"
8' 6"
8' 7"
8' 8"
8' 9"
8' 10"
8' 11"
9' 0"
9' 1"
9' 2'
9' 3'
9' 4"
9' 5"
9' 6"
9' 7"
9' 8"
9' 9"
9' 10"
9' 11"
10' 0"
* Possible Hood
Installation Height
24-1/2"
25-1/2"
25-1/2" to 26-1/2"
25-1/2" to 27-1/2"
25-1/2" to 28-1/2"
25-1/2" to 29-1/2"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
25-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
26-1/2" to 30"
30" min.
30" min.
30" min.
30" min.
30" min.
30" min.
Duct Cover
SUPPLIED
OPTIONAL ACCESSORIES
ZX14SDSS, optional stainless steel duct cover is available
for ceiling heights greater than 10 ft. and up to 14 ft.
Order the optional duct cover at the same time as the
vent hood and have on site before installation. This kit
contains hardware required for installation. This kit contains installation hardware.
Note: Duct covers must be installed as shown in this
book. Do not “build-in” the duct cover. If service is
required, the duct cover must be removed to access
hood components.
30" min.
14' 0"
* Based on 36" countertop height.
The serial plate is located behind the removable lters.
ZX14SDSS