Monogram ZV950SDSS Installation

Installation Instructions
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
ZV950
36" Stainless Steel Vent Hood
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT– Save these instructions
for local inspector’s use.
IMPORTANT – Observe all governing codes
and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
Skill Level – Installation of this appliance requires basic mechanical and electrical skills.
Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer. Product failure due to improper installation is not cov­ered under the Warranty.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1.800.561.3344.
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of these vent hoods, and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes, et pour réduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION COR­RECTEMENT.
WARNING:
To reduce the risk of re or electrical shock, do not use this range hood with any external solid-state speed con­trol device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique, il ne faut pas utiliser cette hotte avec un régulateur de vitesse électronique externe. Toute modication de ce type du branchement d’usine peut endommager l’appareil ou créer un risque de choc électrique.
WARNING: TO REDUCE THE RISK OF
manufacturer. If you have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power o at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES RÈGLES SUIVANTES : A. Utiliser cet appareil uniquement de la manière
prévue par le fabricant. En cas de question, consulter le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disjoncteur, attacher un placard ou une étiquette très visible au panneau.
• For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards including re-rated construction.
• Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
• Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical Code
ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of re and to
properly exhaust air, be sure to duct air outside–Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT­WORK.
PRUDENCE–Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.
2
Design Information
10"
*Height to Ceiling
35-5/8"
25"
Installation
Height Depending
on Ceiling Height
36" Min.
CONTENTS
Design Information
Product Dimensions and Clearances .......................................3–4
Optional Accessories ............................................................................4
Installation Preparation
Advance Planning,
Ductwork, Framing ..............................................................................5
Power Supply ............................................................................................5
Duct Fittings ..............................................................................................6
Tools and Materials Required ...........................................................7
Remove the Packaging ........................................................................7
Check Installation Hardware .............................................................8
PRODUCT DIMENSIONS AND CLEARANCES
36" Vent Hood Installation Combinations
This Stainless Steel Hood can be installed over any Mono­gram cooktop, including the Professional 36" rangetop and 30" or 36" range.
Ductwork, Wiring Locations ..............................................................8
Installation Instructions
Step 1, Install Framing for Hood Support ....................................9
Step 2, Install Mounting Brackets ...................................................9
Step 3, Install Duct Bracket ............................................................. 10
Step 4, Install the Hood ..................................................................... 10
Step 5, Connect Ductwork ............................................................... 11
Step 6, Connect Electrical ................................................................ 11
Step 7, Install Duct Covers ............................................................... 11
Step 8, Install Filters ............................................................................ 12
Step 9, Finalize Installation .............................................................. 12
Cooking surface to bottom of hood should be:
• 25-1/2" max. for 8 ft. ceiling height.
• 25-1/2" to 30" for 9 ft. ceiling height.
• 30" min. for 10 ft. ceiling height. Plan the installation height carefully to avoid unsightly gaps above the hood.
*The supplied duct cover ts 8 ft. to 10 ft . ceilings.
The vent hood must be installed 24" min. and 30" max. above the cooking surface. The hood installation height, from the cooking surface to the bottom of the hood, de­pends upon ceiling height.
This hood must be installed 30" min. above a Monogram Professional Cooktop or Range. Ceiling height for this in­stallation combination must be at least 8'5" high.
Note: The supplied 2-piece duct cover is adjustable to t 8 ft. to 10 ft. ceilings. For ceiling heights greater than 10 ft. and up to 14 ft., order ZX14SDSS stainless steel duct cover accessory.
ZV950SDSS Duct Cover Dimensions
ZX14SDSS Duct Cover Dimensions
3
Design Information
PRODUCT DIMENSIONS AND CLEAR­ANCES (cont.)
Using Duct Cover Accessories
A Duct Cover Accessory may be required for your hood installation height. Use this chart to determine installa­tion height and accessory for your ceiling height.
ZV950SDSS Installation Heights
Actual Ceiling Height
7' 11"
8' 0" 8' 1" 8' 2" 8' 3" 8' 4" 8' 5" 8' 6" 8' 7" 8' 8"
8' 9" 8' 10" 8' 11"
9' 0"
9' 1"
9' 2'
9' 3'
9' 4"
9' 5"
9' 6"
9' 7"
9' 8"
9' 9" 9' 10" 9' 11" 10' 0"
* Possible Hood
Installation Height
24-1/2"
25-1/2" 25-1/2" to 26-1/2" 25-1/2" to 27-1/2" 25-1/2" to 28-1/2" 25-1/2" to 29-1/2"
25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30"
30" min. 30" min. 30" min. 30" min. 30" min. 30" min.
Duct Cover
SUPPLIED
OPTIONAL ACCESSORIES
ZX14SDSS, optional stainless steel duct cover is available
for ceiling heights greater than 10 ft. and up to 14 ft. Order the optional duct cover at the same time as the vent hood and have on site before installation. This kit contains hardware required for installation. This kit con­tains installation hardware.
Note: Duct covers must be installed as shown in this book. Do not “build-in” the duct cover. If service is required, the duct cover must be removed to access hood components.
30" min.
14' 0"
* Based on 36" countertop height.
The serial plate is located behind the removable lters.
ZX14SDSS
4