12"
22-1/2"
35-15/16"
35-15/16"
25"
SOFFIT
SOFFIT
32" min.
38" max.
30" min.
36" max.
SOFFIT
SOFFIT
32" min.
38" max.
30" min.
36" max.
DIMENSIONS AND INSTALLATION INFORMATION
(IN INCHES)
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a
wall or beneath a sot or cabinet.
INSTALLATION WITH WARMING SHELF
• Hoods must be installed 32" Min., 38" Max. over any
type cooking surface when warming shelf is used.
INSTALLATION WITHOUT WARMING SHELF
• Install these hoods 30" Min. to 36" Max. above the
cooking surface when installed over any professional
style cooktop or range.
• These hoods may be installed 24" min. above a gas or
electric drop-in style cooktop.
ZV36RSFSSMONOGRAM 36" STAINLESS STEEL PROFESSIONAL HOOD
NOTE
Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure
standard is applicable.
SOFFIT INSTALLATION
In this installation the ductwork running from the top of
the hood will be concealed in the sot or upper cabinetry.
Each hood is shipped with a stainless steel backguard and
a warming shelf. Hoods may be installed with the shelf or
backguard alone, or with both as shown.
WALL MOUNT INSTALLATION
Install these hoods 30" Min.
to 36" Max. over a professional
style cooktop or range.
Allow 32" Min. and 38" Max.
clearance above any cooking
surface when installed with shelf.
For this installation, a decorative duct cover is available to
conceal the ductwork running from the top of the hood. Use of
the duct cover requires special consideration to the installation
height above the countertop.
Listed by
Underwriters
Laboratories
Product Specification Revised 1/18
ADVANCED PLANNING
6" Duct Cover
12" Duct Cover
DUCTWORK PLANNING
• These vent hoods are equipped for 10" round ductwork.
In most instances they may be transitioned to 8" round.
• This hood may be vented vertically through upper
cabinets, sot or ceiling. A duct transition piece is
supplied for vertical exhaust. Use locally supplied elbows
to vent horizontally through the rear wall.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should not exceed
150 ft. equivalent length for any duct congurations.
• Refer to “Duct Fittings” chart to compute the maximum
permissible length for duct runs to the outdoors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
WALL FRAMING FOR ADEQUATE SUPPORT
• These vent hoods are heavy. Adequate structural support
must be provided. Hoods must be secured to vertical
studs in the wall.
• It is strongly recommended that the vent hood with duct
cover be on site before nal framing and wall nishing.
This will also help to accurately locate the ductwork and
electrical service.
DECORATIVE DUCT COVERS
Decorative duct covers, 6" and 12" high, are available to t
all models. The duct cover conceals the ductwork running
from the top of the hood to the ceiling or sot. Stack one
or more duct covers over the top of the hood to reach
your ceiling height.
ZV36RSFSSMONOGRAM 36" STAINLESS STEEL PROFESSIONAL HOOD
POWER SUPPLY
IMPORTANT – (PLEASE READ CAREFULLY)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with this
appliance. Follow national electrical codes or prevailing
local codes and ordinances.
ELECTRIC SUPPLY
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker or
time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as
possible on the back wall or ceiling.
• Connect the wiring to the house wiring in accordance with
local codes.
GROUNDING INSTRUCTIONS
The grounding conductor must be connected to a ground
metal, permanent wiring system, or an equipment-grounded
terminal or lead on the hood.
WARNING
The improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with
a qualied electrician or service representative if you are in
doubt whether the appliance is properly grounded.
OPTIONAL DUCT COVER ACCESSORIES
Decorative duct covers are available in 6" and 12" heights.
Duct covers may be stacked, in various combinations, to
conceal the ductwork running from the top of the hood
to the ceiling.
• Before you begin, you should
determine the installation
height of the hood and order
the correct size duct cover. The
duct covers should be ordered
at the same time as the vent
hood and be on site before
installation. Order the duct cover
corresponding to your model.
6" DUCT COVERS
HOOD MODEL 6" DUCT COVER DIMENSIONS
ZV36R ZX36DC6 6"H x 15-3/4"W x
11-7/8"D
12" DUCT COVERS
HOOD MODEL 12" DUCT COVER DIMENSIONS
ZV36R ZX36DC12 12"H x 15-3/4"W x
11-7/8"D
Listed by
Underwriters
Laboratories
Product Specification Revised 1/18