GE Monogram® 30" Built-In Advantium 120
OVERALL DIMENSIONS
SPECIFICATIONS
Overall Width 29 3/4" (75.6 cm)
Overall Height 19" (48.3 cm)
Overall Depth
Oven Door Clearance 19" (48.3 cm) Min
Overall Oven
Interior Capacity
Oven Interior Dimensions
(W x H x D)
Minimum Cabinet Width* 30" (76.2 cm)
Minimum Cabinet Depth* 21 1/2" (54.6 cm)
Minimum Base Support 130 lbs (59 kg)
Cutout Width* 25 1/4" (64.1 cm) Min
Cutout Height*
Cutout Depth* 21 1/2" (54.6 cm) Min
Voltz/Hertz/Amps 120 VAC, 60 Hz, 15 Amps
Conduit Length 48" (121.9 cm)
Electrical Rating
Total Amps
Shipping Weight 87 lbs (39.5 kg)
21 1/2" (54.6 cm)
1.6 cu. ft. (.05 cu. cm)
20 1/16" x 8 1/2" x 17"
(51 cm x 21.6 cm x 43.2 cm)
17 1/2" (44.5cm) Min
1.8 kW at 120V
6.3 kW at 240V
29 3/4" (75.6)
FRONT VIEW (SHOWING CUTOUT OVERLAP)
23" (58.4)
2 1/4" (5.7)
5 3/4" (14.6)
19"
(48.3)
SIDE VIEW
2.5"
(6.3)
24 3/4" (62.9)
ZSC1201JSS
4 1/4"
(10.8)
6 3/4"
(17.1)
4 1/2"
(11.4)
14 1/2"
(36.8)
* Additional space will be needed for flush installation.
ATTENTION ELECTRICIAN:
A 120V, 60Hz, 15 Amp circuit is required. An
inidividual properly grounded branch circuit or
circuit breaker is required. Hardware junction box
is required for built-in product.
25 3/4"
(65.4)
2 3/4"
(7.0)
Dimensions in parentheses
are in centimeters unless
otherwise noted. Actual
product dimensions may
vary due to manufacturing
tolerances.
Actual product dimensions
may vary due to
manufacturing tolerances.
TOP VIEW
OPEN OVEN DOOR
SHOWING DOOR CLEARANCE
Product Specification Created 12/14
13"
(33.0)
min
GE Monogram® 30" Built-In Advantium 120 ZSC1201JSS
WALL INSTALLATION
21 1/2" min
(54.6)
cutout depth
17 1/2"
(44.5)
32 1/2"
(82.6)
Recommended
cutout
location
from floor
A
23 1/2" min
(59.7)
cutout depth
Top cleat
Side cleat
Bottom cleat
D
TOP VIEW
Side cleats
30 1/2" (77.5) flush inset width
with 1/4"
(0.6) reveals
25 1/4" (64.1)
cutout width
B
ELECTRICAL
E
17 1/2"
(44.5)
NOTES
A
Based on a user height
of 5' 6" to 5' 10"
B
Junction box location
(May also be located
in adjacent cabinet.)
C
Platform must be
able to support 130 lbs
(90 kg)
D
Top surface of cabinet
must be an appearance
finished surface for
flush installation.
E
Cleats may be visible
and should be finished
to match cabinetry.
F
Maximum toe kick
height of 4" when
installed beneath a
certified cooktop.
STANDARD
INSTALLATION
FLUSH INSET
INSTALLATION
FLUSH INSET INSTALLATION
UNDERCOUNTER INSTALLATION
Dimension varies
17 1/2"
(44.5)
21 1/2" min
(54.6)
cutout depth
25 1/8"
cutout width
C
F
STANDARD
INSTALLATION
STANDARD INSTALLATION
FRONT VIEW
For more details, refer to the installation instructions for this product on Monogram.com.
Dimensions in parentheses are in centimeters unless otherwise noted.
B
ELECTRICAL
(64.1)
FRONT VIEW
23 1/2" min
(59.7)
cutout depth
FLUSH INSET
INSTALLATION
Product Specification Created 12/14