Monogram ZSA1202PSS Quick Specs

MONOGRAM ADVANTIUM® 120 ABOVE­THE-COOKTOP SPEEDCOOKING OVEN
ZSA1202PSS
THE MONOGRAM STATEMENT COLLECTION
Edge-to-edge handles, polished sta inless steel, and ha nd-finished edges convey a sense of solidity a nd beauty
SPEEDCOOK TECHNOLOGY Uses halogen light to cook foods to delicious perfection— two to four times faster than a conventional oven—no preheating required
5-IN-1 OVEN WITH ADVANTIUM® TECHNOLOGY Experience exceptional flexibility and cooking results with the innovative five-in-one oven. Adva ntium® technology enhanced, it can be used as a convection oven, toaster oven, warming/proofing oven, precision cook oven and microwave
EASY-TO-USE-CONTROLS Make it easy to select from more than 175 preprogra mmed recipes
SPACIOUS INTERIOR
13.6" turntable and two full-width oven racks easily accommodates a roast or three 8-1/2" x 11" casserole dishes
FOUR-SPEED, 300-CFM VENTING SYSTEM
Efficiently clears away smoke a nd steam from the cooktop
CONVENIENT TASK LIGHTING
Provides three levels of illumination to suit your needs
FLEXIBLE ABOVE-THE-COOKTOP CONFIGURATION
Makes the most of your kitchen space
For questions about your appliance, please call 1-800-626-2000.
PAGE 1 OF 3
Product Specication Revised 10/20
Above-the-cooktop Advantium oven Dimensions (in inches)
0V outlets
INSTALLATION INFORMATION:
is information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
66" MIN.
Mounting
height
from floor
25-1/2
100˚
Door open
(without
obstruction)
30 max
Minimum distance from door hinge side to adjacent wall should equal 1/2-inch.
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
width required
13"
MAX.
12"
MIN.
16 max
16 max
30" MIN.
16-3/8 max
(Rear)
Exhaust outlet connects to 3-1/4" X 10" duct
Cabinet Front
Cabinet Bottom Shelf
Self-Aligning Screw
Oven Top
240V and 12 need to be spaced on the side if the desire is to setup with top exhaust.
A
A
SIDE VIEW A-A
Filler Block
Equivalent to Depth of Cabinet Recess
This distance can NOT exceed 2” to ensure proper installation with the provided screws.
IMPORTANT:
Please read carefully. For personal safety, is Applia nce Must be properly grounded to avoid severe or fatal shock.
Do not, under any circumstances, cut, deform, or remove any of the prongs from the power cord.
Insure proper ground exists before use.
Dimensions in parentheses a re in centimeters unless otherwise noted. Actual product dimensions may vary due to ma nufacturing tolerances.
For questions about your appliance, please call 1-800-626-2000.
Do not use with an extension cord.
NEMA 14-30R WALL RECEPTACLE
Product Specication Revised 10/20PAGE 2 OF 3
OPTIONAL ACCESSORIES
Grille
FILTER KIT
JX81D–RECIRCULATING CHARCOAL FILTER KIT
To be used when the Advantium oven cannot be vented to the outside.
HELPFUL TIPS
HOOD EXHAUST DUCT
Outside ventilation requires a hood exhaust duct. Read the following carefully.
EXHAUST CONNECTION: e hood exhaust has been designed to mate with a standard 3-1/4" x 10” rectangula r duct.
If a round duct is required, a rectangula r-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST: If a rea r or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared a t the time it is constructed by leaving enough space between the wall studs to accommodate exha ust.
MAXIMUM DUCT LENGTH: For satisfactory a ir movement, the total duct length of 3-1/4" x 10" rectangula r or 6" diameter round duct should not exceed 140 equivalent feet.
Duct EQUIVALENT
Rectangular-To-Round Transition Adaptor
Wall Cap 40 Ft.
90° Round Elbow 10 Ft.
45° Round Elbow 5 Ft.
90° Rectangular Elbow 25 Ft.
45° Rectangular Elbow 5 Ft.
Roof Cap 24 Ft.
5 Ft.
FILLER PANEL KITS JX36B
When replacing a 36" ra nge hood, this kit fills in the additional width to provide a custom built-in appeara nce. For installation between cabinets only; not for end-of­cabinet installa tion. Each kit contains two 3"-wide filler panels.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc.,
present additional resistance to a irflow and a re equivalent to a section of straight duct which is longer tha n their actual physical size. When calculating the total duct length, add the equivalent length of all transitions a nd adaptors plus the length of all straight duct sections. e chart below shows the approximate feet of equivalent length of some typical ducts.
For questions about your appliance, please call 1-800-626-2000.