Monogram ZKW700SSNSS Specifications

MONOGRAM 27" STAINLESS STEEL
ADA
WARMING DRAWER
ZKW700SSNSS
COMPLIANT
THE MONOGRAM MINIMALIST COLLECTION Streamlined design a nd precisely machined metals create a contemporary yet functional aesthetic
1.6 CU. FT. CAPACITY
"ON" INDICATOR LIGHT
INFINITE SETTING TEMPERATURE CONTROL
VARIABLE HUMIDITY CONTROL
Crisp to moist
REMOVABLE HALF RACK
STAINLESS STEEL DRAWER FRONT WITH MINIMAL HANDLE
FULL EXTENSION DRAWER ON BALL BEARING GLIDES
ON/OFF ROCKER SWITCH
For questions about your appliance, please call 1-800-626-2000.
PAGE 1 OF 4
Product Specication Created 10/19
OVERALL DIMENSIONS
SPECIFICATIONS
Overall Width 26 3/4" (68.0 cm)
Overall Height 10 1/2" (26.7 cm)
Overall Depth 23 1/4" (59.0 cm)
Drawer Capacity 1.67 cu. ft. (47.3 l)
Cut-out Width 25 1/2" (64.8 cm)
Cut-out Height 9 1/4" (23.5 cm)
Cut-out Depth 23 1/2" (59.7 cm)
Power Cord Length 56" (142.2 cm)
Electrical Rating 450W @ 120V/60Hz
Total Amps 15 Amps
Net Weight 53 lbs. (23.6 kg)
Approx. Shipping Weight 59 lbs. (26.8 kg)
26 3/4" (68.0)
9 1/4"
(23.5)
cutout height
5/8"
(1.6)
FRONT VIEW (SHOWING CUTOUT OVERLAP)
2 1/8"
(53.9)
25 1/2" (64.8)
cutout width
24 27/32" (63.1)
TOP VIEW
3/8"
(.95)
23 1/4"
(59.0)
1 3/8"
(3.49)
10 1/2"
(26.7)
ATTENTION ELECTRICIAN:
is appliance is supplied with a 56" (142.2 cm) long electrical cord equipped with a 3-prong (grounding) plug tha t mates to a sta ndard 3-prong grounding wall outlet.
e electrical power cord is located on the right side of the warming drawer. Loca te the wall outlet within easy reach of the electrical cord in an adjacent ca binet, within 42" (106.7 cm) of the right side or 16" (40.6 cm) from the left side of the cut-out. A recessed outlet can be installed on the right side of the cut-out, 7" (17.8 cm) max. from the rear of the ca binet.
DO NOT USE AN EXTENSION CORD WITH THIS PRODUCT.
For more details refer to the installa tion instructions for this product.
For questions about your appliance, please call 1-800-626-2000.
26 3/4" (679.4)
including handle
9"
(22.9)
23 1/4" (59.0)22 1/4" (56.5)
SIDE VIEW
Dimensions in parentheses a re in centimeters unless otherwise noted. Actual product dimensions may vary due to ma nufacturing tolerances.
Product Specication Created 10/19PAGE 2 OF 4
INSTALLATION BELOW SINGLE OR DOUBLE WALL OVEN
SIDE VIEW FRONT VIEW
ZTW700SSNSS
SIDE VIEW FRONT VIEW
25 1/2" (64.8)
min. cutout width
2" (5.1)
min.
23 1/2"
(59.7)
min. cutout depth
1" (2.5) min.
above toe-kick
or adjust to oven height
9 1/4"
(23.5)
cutout height
TOP VIEW
Side cleats
ZTW700SSNSS
TOP VIEW
A
2" (5.1)
min.
9 1/4"
(23.5)
cutout height
1" (2.5) min.
above toe-kick
or adjust to oven height
B
23 1/2" (59.7)
min. cutout depth
D
25 1/2" (64.8)
min. cutout width
Side cleats
C
HELPFUL TIPS
A
Warming drawers are approved for
installation below only certa in specified wall oven and cooktop models. See the la bel attached to the top of the wa rming drawer for approved combinations.
B
Additional clearance between cut-outs
may be required. Check to be sure that oven supports above the wa rming drawer location do not obstruct the required interior 23-1/2" depth and 9-1/4" height.
C
If you are installing in frameless cabinets, it
may be necessary to install 1/2" wide clea ts to accept drawer mounting screws. See drawer for mounting screw locations.
D
Install a 2"x2" or 2"x4" Anti-tip block
against rea r wall, 9" from floor of cutout to bottom of block. e anti-tip block must be installed to prevent the drawer from tipping forward when opened a nd loaded. Failure to add the anti-tip block could result in
C
personal injury.
E
When installing the warming drawer below
a cooktop, a solid barrier must be installed at least 1" from the lowest point of the bottom of cooktop burner box to the top of the cut-out. Use any solid ma terial such as 1/4" thick plywood. Allow at least 1/4" a ir gap between the barrier a nd the top of the warming drawer.
INSTALLATION BELOW COOKTOP
From top of countertop
5 1/2"
to top of warming
(14.0)
drawer cutout
min.
D
9 1/4"
(23.5)
cutout height
1" (2.5) min.
above toe-kick
or adjust to
cooktop height
23 1/2" (59.7)
min. cutout depth
E
SIDE VIEW FRONT VIEW
For questions about your appliance, please call 1-800-626-2000.
25 1/2" (64.8)
min. cutout width
PAGE 3 OF 4
For more details refer to the installa tion instructions for this product.
C
Product Specication Created 10/19
INSTALLATION BELOW A CABINET DRAWER
ZTW700SSNSS
SIDE VIEW
FRONT VIEW
TOP VIEW
25 1/2" (64.8)
min. cutout width
23 1/2" (59.7)
min. cutout depth
1/4"
(.6)
min.
1"
(2.5)
min.
Above
toe-kick
Side cleats
9 1/4"
(23.5)
Cut-out
height
ZTW700SSNSS
SIDE VIEW
FRONT VIEW
TOP VIEW
25 1/2" (64.8)
min. cutout width
23 1/2" (59.7)
min. cutout depth
1/4"
(.6)
min.
1"
(2.5)
min.
Above
toe-kick
2" (5.1) min.
Between cut-outs
Side cleats
9 1/4"
(23.5)
Cut-out
height
ZTW700SSNSS
1/4"
(.6)
min.
9 1/4"
(23.5)
Cut-out
height
1"
(2.5)
min.
Above
toe-kick
SIDE BY SIDE INSTALLATION
23 1/2" (59.7)
min. cutout depth
SIDE VIEW
D
2" (5.1) min.
Between cut-outs
B
C
TOP VIEW
Side cleats
A
25 1/2" (64.8)
min. cutout width
FRONT VIEW
HELPFUL TIPS
A
If you are installing in frameless cabinets, it
may be necessary to install 1/2" wide clea ts to accept drawer mounting screws. See drawer for mounting screw locations.
B
Install a 2"x2" or 2"x4" anti-tip block against
rear wall, 9" from floor of cutout to bottom of block. e anti-tip block must be installed to prevent the drawer from tipping forward when opened and loaded. Fa ilure to add the anti-tip block could result in personal injury.
C
When installing the warming drawer below
a ca binet drawer, a solid barrier must be installed at least a bove the warming drawer to block access. Use any solid ma terial such as 1/4" thick plywood. Allow at least 1/4"
A
air gap between the ba rrier and the top of the warming drawer. Observe the 5" min. above the floor or 1" min. a bove the toe kick installation height.
D
When installing two warming drawers side
by side, install them in separa te cut-outs and allow a 2" min. gap between each cut-out.
E
e warming drawer may be supported
by either a solid bottom or 2"x2" or 2"x4" runners. e support must be level and rigidly mounted, flush with the bottom edge of the cut-out (there is no way to level the drawer once it has been installed, so make sure that the supports a re level). e floor or runners must be capable of supporting at least 150 lbs.
For more details refer to the installa tion instructions for this product.
PROVIDING CABINET SUPPORT INSTALLING ANTI-TIP BLOCKS
23 1/2"
(59.7)
or Equivalent Runners
22" (55.9)
E
2" (5.1) x 4" (10.2)
2" (5.1) x 2" (5.1)
Runners or Solid Bottom
or
2" (5.1) x 4" (10.2)
27" (68.6)
For questions about your appliance, please call 1-800-626-2000.
PAGE 4 OF 4
B
Install
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Anti-tip Block against
rear cabinet wall 9" from
floor to bottom of block
Product Specication Created 10/19