Monogram ZISP480DHSS Specification Sheet

OVERALL DIMENSIONS
*84"
(213.4)
48" (121.9)
23 7/8" (60.7)
13 1/2"
(34.3)
30 1/2"
(77.5)
*39 1/2"
(100.3)
*30 1/4"
(76.8)
2 3/4"
(7.0)
*72 1/4"
(183.5)
*3 1/2"
(8.9)
*83 1/2"
(212.1)
SIDE VIEWFRONT VIEW
* Shipping height . Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
48" (121.9)
ZISP480DHSSGE Monogram® 48" Built-In Side-by-Side Refrigerator
2 3/4"
(7.0)
23 7/8" (60.7)
SPECIFICATIONS
Overall Width 48" (121.92 cm)
Overall Height 84" (213.36 cm)
Overall Depth 25 3/4" (65.41 cm)
Door Clearance 28 5/8" (72.7 cm)
Cutout Width 47 1/2" (120.7 cm)
Cutout Height 83 1/2" - 84 1/2"
(212.1 - 214.6 cm)
Cutout Depth 24" (61 cm)
Plumbing Requirements 1.4" OD copper
tubing or GE SmartConnect kit
Shipping Weight 800 lb
*84"
(213.4)
13 1/2"
(34.3)
*39 1/2"
(100.3)
30 1/2"
(77.5)
*30 1/4"
(76.8)
*72 1/4"
(183.5)
* Shipping height . Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
47" (119.4)
Case width
** Allow 15" (38.1) min clearance for 130˚ door swing
*3 1/2"
(8.9)
** Allow 20" (50.8) min clearance for 130˚ door swing
SIDE VIEWFRONT VIEW
*83 1/2"
(212.1)
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply is required. An inidividual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.
28 5/8"
TOP VIEW
** Allow 5" (12.7) min
clearance to a wall for 90˚
door swing
** These refrigerators are equipped with a 2-position door stop. The factory-set 130° door swing can be adjusted to 90° if clearances to adjacent cabinets or walls is restricted. Allow full 130° door swings for pan removal. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimension may vary due to manufacturing tolerances.
** Allow 5" (12.7) min
clearance to a wall for 90˚
door swing
Product Specification Created 6/14
(72.7)
GE Monogram® 48" Built-In Side-by-Side Refrigerator
FRONT VIEW SIDE VIEW
W
24" (61.0)
2"
(5.1)
4 3/4"
(12.1)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
E
WATER
47 1/2" (120.7)
20" (50.8)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5) From floor to bottom
of electrical
area
6"
(15.2)
5"
(12.7)
5"
(12.7)
5"
(12.7)
ZISP480DHSS
STANDARD INSTALLATION
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
ANTI-TIP BRACKET
SIDE VIEW INSTALLED
UNDER SOFFIT
(12.7)
C
SOFFIT
6"
(15.2)
5"
FRONT VIEW SIDE VIEW
47 1/2" (120.7)
A
20" (50.8)
E
5"
(12.7)
From floor to bottom
of electrical
3 1/2"
5"
(12.7)
(8.9)
WATER
B
D
SIDE VIEW INSTALLED
WITH WOODEN WALL STUDS
AND NO SOFFIT
75"
(190.5)
area
Screws mounted into vertical wall
*84"
(213.4)
*Or installation
height from floor
4 3/4"
(12.1)
24" (61.0)
2"
(5.1)
W
The refrigerator will project forward, slightly beyond adjacent cabinetry.
2" x 4"
Cut to 35" Length
studs
Top Case Trim
Install Screws
Through Trim and Into
3/4" Min. Wood Brace
FRONT VIEW INSTALLED
WITH METAL WALL STUDS
AND NO SOFFIT
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
Side View Top
Case Trim
3/4" Min.
NOTES
A
Mounting the junction
box in this location will also allow for front accessability through access panel.
B
Water supply area.
WARNING:
The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury.
The information below is for cabinet design only.
When installing the anti­tip system you must use the product installation instructions.
Determine your installation construction and required anti-tip configuration:
C
Installed Under Soffit
After installing unit into installation opening, raise grille panel and screw metal case sides to adjacent cabinet. When installed under a soffit, the soffit cannot exeed 24” deep. The top case trim overlaps the bottom of the soffit.
D
Wooden Wall Studs and
No Soffit
• Cut a 2” x 4” block and secure to brackets provided.
• Secure brackets to back wall of opening at 84” or your installation height from the floor.
E
Metal Wall Studs and
No Soffit
E
This method requires securely fastened cabinets on both sides and a ¾” minimum wood brace above unit, with it’s front surface 24” from back wall.
• After installing unit into opening, raise grille panel and attach metal case top trim to ¾” minimum wood brace.
• The brace spanning the enclosure must be securely fastened to cabinets on both sides.
See Installation Instructions for detailed instructions.
Product Specification Created 6/14
Loading...