42" (106.7)
*84"
(213.4)
*72 1/4"
(183.5)
2 3/4"
(7.0)
*3 1/4"
(8.3)
SIDE VIEWFRONT VIEW
25 3/4" (65.4)
23 7/8" (60.7)
*83 1/2"
(212.1)
13 1/2"
(34.3)
30 1/2"
(77.5)
*39 1/2"
(100.3)
*30 1/4"
(76.8)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
OVERALL DIMENSIONS
42" (106.7)
13 1/2"
(34.3)
ZISP420DKSSMONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR
2 3/4"
(7.0)
25 3/4" (65.4)
23 7/8" (60.7)
SPECIFICATIONS
Overall Width 42" (91.44 cm)
Overall Height 84" (213.4 cm)
Overall Depth 25 3/4" (65.41 cm)
Door Clearance 26 5/8" (67.6 cm)
Cutout Width 41 1/2" (105.4 cm)
Cutout Height 83 1/2" - 84 1/2"
(212.1 - 214.6 cm)
Cutout Depth 24" (61 cm)
Plumbing Requirements 1/4" OD copper
tubing or GE
SmartConnect kit
Shipping Weight 750 lb
*84"
(213.4)
*39 1/2"
(100.3)
30 1/2"
(77.5)
*30 1/4"
(76.8)
*72 1/4"
(183.5)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
41" (104.2)
Case width
** Allow 13" (33.0) min
clearance for 130˚
door swing
*3 1/4"
(8.3)
** Allow
19" (48.3) min
clearance for 130˚
door swing
*83 1/2"
(212.1)
SIDE VIEWFRONT VIEW
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power
supply is required. An inidividual properly
grounded branch circuit or circuit breaker
is recommended. Install a properly
grounded 3-prong electrical receptacle
recessed into the back wall.
26 5/8"
(67.6)
TOP VIEW
** Allow
clearance to a wall for 90˚
5" (12.7) min
door swing
** These refrigerators are equipped with a 2-position door stop. The factory-set 130° door
swing can be adjusted to 90° if clearances to adjacent cabinets or walls is restricted. Allow
full 130° door swings for pan removal. If the 90° door stop position is used, pan access is
maintained, but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted. Actual
product dimension may vary due to manufacturing tolerances.
** Allow 5" (12.7) min
clearance to a wall for 90˚
door swing
Product Specification Revised 9/16

ZISP420DKSSMONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR
FRONT VIEW SIDE VIEW
W
24" (61.0)
2"
(5.1)
4 3/4"
(12.1)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
E
WATER
41 1/2" (105.4)
18" (45.7)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5)
From floor
to bottom
of electrical
area
6"
(15.2)
5"
(12.7)
5"
(12.7)
5"
(12.7)
STANDARD INSTALLATION
41 1/2" (105.4)
6"
(15.2)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
The refrigerator will project forward, slightly beyond adjacent cabinetry.
ANTI-TIP BRACKET
SIDE VIEW INSTALLED
5"
(12.7)
WATER
FRONT VIEW SIDE VIEW
C
SOFFIT
UNDER SOFFIT
18" (45.7)
A
E
5"
(12.7)
75"
(190.5)
From floor
to bottom
of electrical
area
3 1/2"
5"
B
SIDE VIEW INSTALLED
WITH WOODEN WALL STUDS
(8.9)
(12.7)
D
AND NO SOFFIT
4 3/4"
(12.1)
Screws mounted
into vertical wall
*84"
(213.4)
*Or installation
height from floor
2" x 4"
Cut to 35" Length
studs
WITH METAL WALL STUDS
24" (61.0)
2"
(5.1)
7/16"
Trim overlap
3 1/2"
(8.9)
W
Side View Top
Top Case Trim
Install Screws
Through Trim and Into
3/4" Min. Wood Brace
Case Trim
FRONT VIEW INSTALLED
AND NO SOFFIT
(1.1)
3/4"
Min.
NOTES
A
Mounting the junction box
in this location will also
allow for front accessability
through access panel.
B
Water supply area.
WARNING:
The refrigerator is top heavy
and must be secured to
prevent the possibility of
tipping forward. Failure to
do so may result in death or
serious injury.
The information below is for
cabinet design only. When
installing the anti-tip system
you must use the product
installation instructions.
Determine your installation
construction and required
anti-tip configuration:
C
Installed Under Sot
After installing unit into
installation opening, raise
grille panel and screw metal
case sides to adjacent cabinet.
When installed under a sot,
the sot cannot exeed 24"
deep. The top case trim
overlaps the bottom of the
sot.
D
Wooden Wall Studs and No
Sot
• Cut a 2" x 4" block and
secure to brackets provided.
• Secure brackets to back wall
of opening at 84" or your
installation height from the
floor.
E
Metal Wall Studs and No
E
Sot
This method requires securely
fastened cabinets on both
sides and a 3/4" minimum
wood brace above unit, with
it’s front surface 24" from back
wall.
• After installing unit into
opening, raise grille panel and
attach metal case top trim to
3/4" minimum wood brace.
• The brace spanning the
enclosure must be securely
fastened to cabinets on both
sides.
See Installation Instructions for
detailed instructions.