Monogram ZIS420NNII Specifications

MONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR
ZIS420NN
FLUSH INSET INSTALLATION
Allows the refrigerator to be installed flush with adjacent ca binetry
ADVANCED TEMPERATURE MANAGEMENT SYSTEM WITH MULTI-SHELF AIR TOWER
CLIMATE-CONTROL DRAWER Allows you to express-chill beverages, express-thaw meats a nd select specific temperatures for perisha ble foods
WIFI CONNECT Enjoy the convenience and freedom of wirelessly controlling functions from your smartphone
LED LIGHTING Light columns in the freezer and fresh food compa rtments extend the full length of the interior and LED lighting loca ted inside the vegetable a nd climate-control drawers illumina te contents without compromising space
GE® WATER FILTER Has been moved from the fresh food compartment to the overhead cabinet, where it is discreetly out of sight
For questions about your appliance, please call 1-800-626-2000.
DELI DRAWER ON FULL-EXTENSION SLIDES Keeps meats, cheeses a nd other everyday foods within easy reach
SEALED VEGETABLE DRAWER Helps preserve the freshness of foods
ADJUSTABLE GLASS SHELVES Easily accommodate pa rty trays and pla tters
GALLON-SIZE DOOR BIN Holds milk containers, two-liter bottles a nd pitchers
ADJUSTABLE DOOR BINS Can be moved to one of two positions in seven loca tions
DAIRY BIN WITH CENTER DIVIDER Has a unique magnetic seal tha t locks in freshness
FILTER-CHANGE INDICATOR LIGHT Located on the upfront control pa nel, provides a visual reminder when it's time to replace the filter for the water dispenser
SABBATH MODE Designed to disable functions in accorda nce with Sabba th­observing practice
PAGE 1 OF 12
Product Specication Created 10/19
SECTION 1
STANDARD INSTALLATION
1/4" FRAMED PANELS 3/4" OVERLAY PANELS
SECTION 2
FLUSH INSET INSTALLATION
For questions about your appliance, please call 1-800-626-2000.
STANDARD INSTALLATION
Product Specication Created 10/19PAGE 2 OF 12
OVERALL DIMENSIONS
42" (106.7)
STANDARD INSTALLATION
25 3/4" (65.4)
23 1/2" (59.7)
SPECIFICATIONS
Overall Width 42" (106.7 cm)
Overall Height 84" (213.36 cm)
Overall Depth 25 3/8" (64.453 cm)
Door Clearance 26 9/16" (67.5 cm)
Cutout Width 41 1/2" (105.4 cm)
Cutout Height 83 1/2" - 84 1/2"
(212.1 - 214.6 cm)
Cutout Depth 24" (61 cm)
Plumbing Requirements 1/4" OD copper
tubing or GE SmartConnect kit
Shipping Weight 725 lb (328.9 kg)
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.
*84"
(213.4)
68 1/2"
(174.0)
*72 5/16"
(183.7)
*83 1/2"
(212.1)
SIDE VIEWFRONT VIEW
* Shipping height. Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
35" (89.0)
Case width
**
Allow
13" (33.0)
min clearance for 130˚ door swing
**
Allow
19" (48.3)
min clearance for 130˚ door swing
26 9/16"
(67.5)
TOP VIEW
** Allow 4 9/16" (11.6) min
clearance to a wall for 90˚
door swing
** These refrigerators are equipped with a 3-position door stop. The factory-set 115° door
swing can be adjusted to 90° if clearances to adjacent cabinets or walls is restricted. Allow full 130° door swings for pan removal. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted. Dimensions based on custom handle height of 2 9/16" (6.5).
** Allow 4 9/16" (11.6) min
clearance to a wall for 90˚
door swing
For questions about your appliance, please call 1-800-626-2000.
Dimensions in parentheses a re in centimeters unless otherwise noted. Actual product dimensions may vary due to ma nufacturing tolerances.
Product Specication Created 10/19PAGE 3 OF 12
STANDARD INSTALLATION
FRONT VIEW SIDE VIEW
W
24" (61.0)
1 1/2"
(3.8)
3 1/4"
(8.3)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
E
WATER
47 1/2" (120.7)
20" (50.8)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 ) From floor to bottom
of electrical
area
6"
(15.2)
5"
(12.7)
5"
(12.7)
5"
(12.7)
STANDARD INSTALLATION
TOP VIEW
SIDE VIEW
24" (61)
1 9/16"
(3.97)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
*84 1/2"
(214.6)
*Trim will overlap
additional 7/16"
41 1/2" (105.4)
A
6"
(15.24)
(12.7)
5"
(12.7)
WATERW
FRONT VIEW
e refrigerator will project forwa rd, slightly beyond adjacent cabinetry.
ANTI-TIP BRACKET
C
SOFFIT
SIDE VIEW INSTALLED
UNDER SOFFIT
D
SIDE VIEW INSTALLED
WITH WOODEN WALL STUDS
AND NO SOFFIT
Screws mounted
into vertical wall
*84"
(213.4)
*Or installation
height from floor
2" x 4"
Cut to 35" Length
studs
18" (45.7)
E
5"
(12.7)
B
FRONT VIEW INSTALLED
WITH METAL WALL STUDS
75"
(190.5 )
From floor
to bottom
of electrical
area
3 1/2"
5"
(8.9)
Top Case Trim
Install Screws
Through Trim and Into
3/4" Min. Wood Brace
AND NO SOFFIT
E
3/4" Min.
Side View Top
Case Trim
HELPFUL TIPS
A
Mounting the junction box in this
location will also allow for front accessibility through access panel.
B
Water supply area.
WARNING:
e refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in dea th or serious injury.
e information below is for ca binet design only. When installing the anti-tip system you must use the product installation instructions.
Determine your installation construction and required anti-tip configuration:
C
Installed Under Soffit
After installing unit into installation opening, ra ise grille panel a nd screw metal case sides to adjacent cabinet. When installed under a soffit, the soffit ca nnot exceed 24" deep. e top case trim overlaps the bottom of the soffit.
D
Wooden Wall Studs and No Soffit
• Cut a 2" x 4" block and secure to brackets provided.
• Secure brackets to back wall of opening at 84" or your installa tion height from the floor.
E
Metal Wall Studs and No Soffit
is method requires securely fastened cabinets on both sides a nd a 3/4" minimum wood brace a bove unit, with it’s front surface 24" from back wall.
• After installing unit into opening, raise grille pa nel and attach metal case top trim to 3/4" minimum wood brace.
• e brace spanning the enclosure must be securely fastened to cabinets on both sides.
See Installation Instructions for detailed instructions.
For questions about your appliance, please call 1-800-626-2000.
Product Specication Created 10/19PAGE 4 OF 12
Loading...
+ 8 hidden pages