Monogram ZIR360NHRH, ZIRP360NHRH, ZWE23ESHSS Installation Manual

INSTALLATION INSTRUCTIONS
with Design Guide
36” Built-In All-Refrigerators and All-Freezers
Pour obtenir une version française de ce manuel, visitez notre site Web sur Monogram.com.
Monogram.com
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these instructions for
• local inspector’s use. Observe all governing codes and ordinances.
Note to Installer – Be sure to leave these
• instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
If you received a damaged unit, you should immediately contact your dealer or builder.
Skill Level – Installation of this unit requires basic
mechanical, carpentry and plumbing skills. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Monogram Warranty. See the Owner’s Manual for warranty information.
WARNING
Plug into a grounded 3-prong outlet. Do not remove the ground prong. Do not use an adapter. Immediately discontinue use of a damaged supply cord.
If the supply cord is damaged it must be replaced by a qualified service professional with an authorized service part from the manufacturer.
WARNING
Electrical Shock Hazard.
Do not use an extension cord with this appliance. Failure to follow these instructions can result in death,
fire, or electrical shock. Follow the instructions in the section Grounding the unit. This appliance must be installed with a means in the
fixed house wiring or circuit breaker for disconnecting the appliance from the electrical supply after installation.
Tip Over Hazard.
These appliances are top heavy, especially with any doors open, and must be secured to prevent tipping forward which could result in death or serious injury. Read and follow the entire installation instructions for securing the appliance with the anti-tip system.
WARNING
Explosion Hazard.
Keep flammable materials and vapors, such as gasoline, away from appliance. Failure to do so can result in fire, explosion, or death.
WARNING
To reduce the risk associated with choking, do not allow children under 3 years of age to
have access to small parts during the installation of this product.
CAUTION
Lifting Hazard
This unit is very heavy. To reduce the risk of person injury during maneuvering and installing this appliance, 3 people are required for proper installation.
CAUTION
Keep fingers out of the “pinch point” areas; clearances between the doors and between the
doors and cabinet are necessarily small. Be careful closing doors when children are in the area.
For Monogram local service in your area, call 1.800.444.1845 or visit monogram.com. For Monogram service in Canada, call 1.800.561.3344 For Monogram Parts and Accessories, call 1.800.444.1845 or visit monogram.com.
2
31-49140-2
Consignes de sécurité
AVANT DE COMMENCER
Veuillez lire toutes ces instructions attentivement.
IMPORTANT – Conservez ces instructions à
l’usage de l’inspecteur local. Observez tous les codes et décrets en vigueur.
Note à l’installateur – Assurez-vous de laisser ces
• instructions au consommateur.
Note au consommateur - Conservez ces instructions
avec votre manuel d’utilisation pour
Si vous avez reçu un appareil endommagé, veuillez communiquer immédiatement avec votre revendeur ou votre
entrepreneur.
consultation ultérieure.
Niveau de compétence – L’installation de cet appareil
exige des compétences de base en mécanique, menuiserie et plomberie. La responsabilité d’une installation adéquate relève de l’installateur. La garantie Monogram ne couvre pas les défectuosités du produit causées par une installation inadéquate. Consultez le manuel d’utilisation pour des renseignements sur la garantie.
AVERTISSEMENT
Branchez l’appareil dans une prise à 3 broches mise à la terre. N’enlevez pas la broche de mise à la terre. N’utilisez pas un adaptateur. Cessez immédiatement l’utilisation d’un cordon électrique
endommagé. Si le cordon électrique est endommagé, son rem­placement doit être exécuté par un technicien en réparation qua­lifié au moyen d’un cordon de rechange autorisé par le fabricant.
AVERTISSEMENT
Ces électroménagers sont lourds du haut, notamment lorsqu’une porte est ouverte, de sorte qu’ils doivent être fixés pour prévenir un basculement vers l’avant susceptible d’occasionner des blessures graves ou la mort. Lisez et observez la totalité des instruc­tions d’installation pour connaître la façon de fixer l’électroménager sur le dispositif antibasculement.
AVERTISSEMENT
Gardez les matières et les vapeurs inflammables telles que l’essence à distance de l’électroménager. L’omission de prendre cette précaution peut entraîner un incendie, une explosion ou la mort.
AVERTISSEMENT
à la portée des enfants âgés de moins de 3 ans.
Risque d’électrocution.
N’utilisez pas un cordon de rallonge avec cet électroménager. Le non-respect de ces instructions peut occasionner un décès,
un incendie ou un choc électrique Suivez les instructions de la section Mise à la terre de l’appareil. Le circuit électrique auquel cet électroménager sera raccordé
doit comporter un disjoncteur ou un autre dispositif permettant de couper l’alimentation électrique à l’appareil après l’installation.
Risque de basculement.
Risque d’explosion.
Pour réduire le risque d’étouffement pendant l’installation de ce produit, ne pas laisser les petites pièces
AVERTISSEMENT
Cet appareil est très lourd. Afin de réduire le risque de blessure pendant la manipulation et l’installation de cet électroménager, la participation de 3 personnes est nécessaire à l’exécution d’une installation correcte.
AVERTISSEMENT
portes et l’armoire sont particulièrement restreints. Soyez prudent lorsque vous fermez les portes en présence d’enfants.
Risque lié à la manipulation d’un objet lourd
Gardez vos doigts éloignés des points de pincement. Les espaces entre les portes et ceux entre les
Pour joindre le service Monogram de votre région, composez le 1.800.444.1845 ou visitez monogram.com. Pour le service Monogram au Canada, composez le 1.800.561.3344. Pour le service des Pièces et accessoires Monogram, composez le 1.800.444.1845 ou visitez monogram.com.
3
31-49140-2
Información de seguridad
ANTES DE COMENZAR
Lea estas instrucciones en su totalidad y atentamente.
IMPORTANTEConserve estas instrucciones
para uso del inspector local. Cumpla con todos los códigos y ordenanzas gubernamentales.
Nota para el Instalador – Asegúrese de que el
• Comprador conserve estas instrucciones.
Nota para el Consumidor – Guarde estas
• instrucciones con su Manual del Propietario para referencia futura.
Si la unidad que recibió está dañada, se deberá comunicar de inmediato con su vendedor o fabricante.
Nivel de habilidad – La instalación de esta unidad
requiere un nivel básico de habilidades mecánicas, de carpintería y plomería. La correcta instalación del producto es responsabilidad del instalador. Si se producen fallas en el producto debido a una instalación inadecuada, la Garantía de Monogram no cubrirá las mismas. Para obtener información sobre la garantía, consulte el Manual del Propietario.
ADVERTENCIA
Enchufe en un tomacorriente con conexión a tierra de 3 cables. No elimine el cable de conexión a tierra. No use un adaptador. Inmediatamente interrumpa el uso de un cable de suministro de
corriente dañado. Si el cable de corriente se encuentra dañado, su reemplazo deberá ser realizado por un profesional calificado del servicio técnico, utilizando una pieza del servicio técnico autorizada por el fabricante.
No use prolongadores con este electrodoméstico.
ADVERTENCIA
Estos electrodomésticos son inestables, especialmente cuando una puerta se encuentre abierta, y deben estar asegurados a fin de evitar caídas hacia adelante que podrían resultar en la muerte o en lesiones graves. Lea y siga las instrucciones de instalación en su totalidad para asegurar el electrodoméstico con el sistema antivolcaduras.
ADVERTENCIA
Mantenga cualquier material y vapores inflamables, tales como gasolina, alejados del electrodoméstico. Si no se cumple con esto, se podrá producir una explosión, un incendio o la muerte.
ADVERTENCIA
edad tengan acceso a las partes pequeñas durante la instalación de este producto.
Riesgo de Descarga Eléctrica
Si no se siguen estas instrucciones, se podrá producir la muerte, incendios o descargas eléctricas.
Siga las instrucciones que figuran en la sección de Conexión de Tierra de la unidad.
Este electrodoméstico deberá ser instalado por algún medio en el cableado fijo del hogar o en un disyuntor para desconectar el electrodoméstico del suministro eléctrico luego de la instalación.
Riesgo de Caída
Riesgo de Explosión
A fin de reducir el riesgo asociado con descargas, no permita que los niños menores de 3 años de
PRECAUCIÓN
Esta unidad es muy pesada. A fin de reducir el riesgo de lesión de una persona al maniobrar e instalar este electrodoméstico, se requiere contar con 3 personas para una correcta instalación.
PRECAUCIÓN
las puertas y entre las puertas y el gabinete son necesariamente pequeños. Tenga el cuidado de cerrar las puertas cuando los niños se encuentren en el área.
Para acceder al servicio local de Monogram en su área, llame al 1.800.444.1845 o visite monogram.com. Para acceder al servicio de Monogram en Canadá, llame al 1.800.561.3344. Para acceder a Piezas y Accesorios de Monogram, llame al 1.800.444.1845 o visite monogram.com.
Riesgo al levantar la puerta
Mantenga los dedos fuera de los espacios de “riesgo de lastimaduras”; los espacios entre
4
31-49140-2
Contents
Safety 2 Instructions for Standard Installation 6
Planning Guide
The Installation Space 7 Dimensions and Clearances 7 Customization Basics 9 Refrigerator Location 9 1/4” Framed Panel Dimensions 10 3/4” Overlay Panel Dimensions 10 Side Panels 11 ZUG2 Grille Panel Dimensions 11
130° Door Swing 12
Installation Instructions
Tools, Hardware, Materials 13 Grounding the Unit 13 Step 1. Remove Packaging 14 Step 2. Install Water Line 14 Step 3. Install Side Panels 15 Step 4. Anti-Tip Procedures 15 Step 5. Level Unit 18 Step 6, Secure Unit to Wall 18 Step 7. Adjust Door Swing 19 Step 8. Install Grille Panel 19 Step 9. Install Framed Panels 20 Step 9A. Install Overlay Panels 21 Step 10. Connect Water Supply 22 Step 11. Start Icemaker 22 Step 12. Install Toekick 22
Instructions for Flush Installation 23
Planning Guide
The Installation Space 24 Dimensions and Clearances 24 Custom Handle Design Guide 25 1/2” Overlay Panel Dimensions 26 3/4” Decorative Panel Dimensions 27 3/4” Raised Door Panel Routing 28 3/4” Raised Grille Panel Routing 29 3/4” Raised Door Panel Routing for Unified Installation 30 Side Panels 31 Side Cleats 31 ZUG2 Grille Panel Dimensions 31 Unified Door Panel Dimensions 31 Refrigerator Location 31
Installation Instructions
Tools, Hardware, Materials 32 Grounding the Unit 32 Step 1. Remove Packaging 33 Step 2. Install Water Line 33 Step 3. Install Side Panels 33 Step 4. Install Case Trim 34 Step 5. Anti-Tip Bracket 34 Step 6. Level Unit 36 Step 7. Adjust Door Swing 37 Step 8. Install Grille Panel 37 Step 9. Install overlay Panels 38 Step 10. Connect Water Supply 39 Step 11. Start Icemaker 39 Step 12. Install Toekick 39
Instructions for Stainless Steel Installation 40
Planning Guide
The Installation Space 41 Dimensions and Clearances 41 Customization Basics 43 Refrigerator Location 43 130° Door Swing 44
Installation Instructions
Tools, Hardware, Materials 45 Grounding the Unit 45 Step 1. Remove Packaging 46 Step 2. Install Water Line 46 Step 3. Install Side Panels 46 Step 4. Anti-Tip Bracket 47 Step 5. Level Unit 49 Step 6, Secure Unit to Wall 50 Step 7. Adjust Door Swing 50 Step 8. Connect Water Supply 51 Step 9. Start Icemaker 51 Step 10. Install Toekick 51
31-49140-2
5
Instructions for Standard Installation
6
Design Guide - Standard Installation
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24” (60.96 cm) Minimum
The unit will project forward, slightly beyond adjacent cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit: When installed beneath a soffit, the soffit cannot exceed the 24” (60.96 cm) installation depth shown. The top case trim overlaps the bottom of the soffit.
DIMENSIONS AND CLEARANCES
35"
Case Width
*83-1/2"
at
Rear
Depth Including Handles 26-7/8"
Product Clearances
These units are equipped with a 3-position door stop. The factory set 115° door swing can be adjust­ed to 90° if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90° and 130°.
130° Door Swing
25-3/8" Case Depth
* Shipping height. The
product can be adjusted to fit into a cutout that
*84" From Floor to Top Frame
36" Frame to Frame Width
is 84-1/2” (214.63 cm) max. height. Note that the top case trim at the front is 1/2” (1.27 cm) higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1” (2.54 cm) height adjustment.
90° Door Swing
90° Door Swing
4” Minimum to a Wall
23-7/8” Case Behind Frame
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4” O.D. copper tubing or QuickConnect™ kit between the cold water line and water connection location, long enough to extend to the front of the unit. Installation of an easily accessible shut-off valve in the water line is required.
36-3/4”
90°
115° Door Swing
Allow 25” (63.5 cm) minimum clearance for a full 130° door swing. Allow 15” (38.1cm) for pan removal.
For a 90° door swing, allow 4” (10.16 cm) minimum clearance to a wall. If the 90° doorstop position is used, pan access is maintained but pan removal is restricted.
See illustration on page 11 to determine door swing interaction with adjacent cabinets or countertops.
31-49140-2
7
Design Guide - Standard Installation
CLEARANCES
25"
130° Door
Swing
130°
Min. to
Wall
These units are equipped with a 3-position door stop. The factory set 115° door swing can be adjusted to 90° or 130° if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90° and 130°.
When Installed into a corner:
Allow 25” (63.5 cm) for a full 130° door swing. Allow 15” (38.1cm) for pan removal. Allow 4” (10.16 cm) min. clearance when door swing is adjusted to a 90° opening for pan access, but pan removal is restricted.
2"
15"
Clearances for two products installed side-by­side with the same (left or right) door swing
Allow 2” (5.08 cm) minimum clearance between the products to prevent door swing interference. Order the WX14X99 adjustable door stop to reduce the factory set 115° door swing. Allow 15” (38.1cm) minimum to a wall to achieve full drawer extension and pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this installation.
5"
Clearances for Multiple Single Door Installations In a side-by-side installation of a left and right door swing product, a 1” (2.54 cm) clearance between the units is required. Order ZUGSS2 Stainless Steel Unified Grille Panel Kit or ZUG2 Custom Panel Unified Grille Panel Kit for one continuous grille panel.
INSTALLATION
ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two units, side by side, the installation space must be 71-1/2” (181.61 cm) wide.
NOTE: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width.
• The water and electrical locations for each product must
be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Clearances for two products installed side-by­side with right and left side hinges together Allow
5” (12.7 cm) minimum between the two products to prevent one door from striking the other. Use the WX14X99 adjustable door stop to reduce the factory set 115° door swing and to allow pan removal.
NOTE: ZUG2 and ZUGSS2 Grille Panel Kit will NOT fit this installation.
8
31-49140-2
Design Guide - Standard Installation
CUSTOMIZATION BASICS: Framed or Overlay Panels, Custom
Handles and Accessory Kits
Trimmed models are designed to be customized with decorative panels. Field installed custom door and grille panels are required.
Optional Accessory Kits
• ZKHSS2: Monogram Tubular Stainless Steel handles designed to fit 3/4” (1.9 cm) overlay panels.
• ZKHPSS1: Pro Tubular Stainless Steel handle designed to fit 3/4” (1.9 cm) overlay panels.
• ZUG2: For side-by-side installation of two trimmed models. This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay panel.
REFRIGERATOR LOCATION
• Do not install the refrigerator where the temperature will go below 55°F (13°C). It will not run often enough to maintain proper temperatures.
• Do not install the refrigerator where temperatures will go above 100°F (37°C). It will not perform properly.
• Do not install the refrigerator in a location exposed to water (rain, etc.) or direct sunlight.
Install it on a floor strong enough to support it fully loaded.
31-49140-2
9
Design Guide - Standard Installation
1/4” (0.63 cm) FRAMED PANEL DIMENSIONS
If you choose to install framed panels, they must be cut to the dimensions shown. The panels will slide into the frame on the door and grille.
If the custom panel is less than 1/4” (0.63 cm) thick and if it fits loosely in the door frame, it can be backed up with a piece of filler material or foam tape to improve the fit.
IMPORTANT NOTE: Maximum weight for door panel is 67 pounds (30 kg). Maximum total weight for assembled grille panel is 11 pounds (5 kg).
Framed Panel Dimensions
1/4” (0.63 cm) Framed Panel
Overlay Panel Dimensions
1/4” (0.63 cm) Backer Panel
0.10” (0.25 cm) Spacer Panel
3/4” (1.9 cm) Overlay Panel
A (Width) B (Grille Height) C (Door Height)
33-7/8” (86.04 cm) 8-7/8” (22.54 cm) 69-5/16”(176.05 cm)
A (Width) B (Grille Height) C (Door Height) 33-7/8” (86.04 cm) 8-7/8” (22.54 cm) 69-5/16”(176.05 cm) 32-1/2” (82.55 cm) 7-5/8” (20 cm) 67-15/16”
34-1/8” (96.67 cm) 9” (22.86 cm) 69-9/16”
Door
5/16"
Trim
Reveal
1/4"
Panel
(172.56 cm)
(176.69 cm)
3/4” (1.9 cm) OVERLAY PANEL DIMENSIONS
For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4” (0.63 cm) thick backer panel which slides into the trim. A spacer panel 0.10” (0.25 cm) thick must be placed between the overlay and backer panel.
IMPORTANT NOTE: Maximum total weight for assembled door panel is 67 pounds (30.39 kg). Maximum total weight for assem­bled grille panel is 11 pounds (4.99 kg).
Assemble the panels with glue and screws.
• Center the spacer panel on the backer panel, left to right and top to bottom. Secure the panels with glue.
• Center the spacer and backer panel on the overlay panel and secure with glue and screws. Screws must be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal to top-to-bottom offset.
10
31-49140-2
Design Guide - Standard Installation
SIDE PANELS
Side panels must be used whenever the sides of the unit will be exposed. The 1/4” (0.63 cm) side panels will slip into the side case trim. Secure the panels to the unit with stick-on hook and loop fastener strips. Order the side panels from the cabinet manufacturer.
• Cut a notch in the top front corner as shown to allow clearance for corner keys in the front side trim.
24"
* Depending on
installation height.
3/16"
1-7/8"
*84"
*3" to 4"
ZUG2 GRILLE PANEL DIMENSIONS
The ZUG2 unified grille panel kit provides for the installation of a framed or overlay grille panel.
Framed Panel Dimensions
1/4” (0.63 cm) Framed Panel
Overlay Panel Dimensions
1/4” (0.63 cm) Backer Panel
0.10” (0.25 cm) Spacer Panel
3/4” (1.9 cm) Overlay Panel
IMPORTANT NOTE: The maximum weight for the unified grill is 25 pounds (11.24 kg).
A (Width) B (Height)
69-7/8” (177.48 cm) 8-7/8” (22.54 cm)
A (Width) B (Grille Height)
69-7/8” (177.48cm) 8-7/8” (22.54 cm)
68-1/2” (97.79 cm) 7-5/8” (20 cm)
70-1/8” (178.12 cm) 9” (22.86 cm)
2-9/16"
Assemble the overlay panels in the same manner as the door panel.
31-49140-2
11
Design Guide - Standard Installation
Frameless Cabinets: The case trim
overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips.
Top View 130° DOOR SWING Scale 1:1
12
31-49140-2
Installation Instructions - Standard Installation
TOOLS AND MATERIALS REQUIRED
• Tin snips to cut banding
• #2 Phillips screwdriver
• Stepladder
• Drill and 1/2”, 3/16” bits
• Bucket
• 1/4”, 1/2”, 5/16”, 7/16” socket
• Level
• Safety glasses
• Appliance hand truck
• Pliers
• Tubing cutter
• Stud finder
• 7/16” and 1-1/4” open-end wrench
• 1/4” copper water line tubing or SmartConnect Refrigerator Tubing kits
• Water shut-off valve (optional but recommended)
• Custom panels for door and grille panel
• Screws to secure unit to cabinetry
• Stick-on hook and loop fastener strips for 1/4” (0.63 cm) side panels
HARDWARE SUPPLIED
• Water filter bypass plug
• Anti-Tip brackets
• 3 lag screws
• 2 Hair Pin Cotters
• 4 washers
• 5 toggles with bolts
• Toekick
FLOORING
For proper installation, this product must be placed on a level surface of hard material that is at the same height as the rest of the flooring. This surface should be strong enough to support a fully loaded refrigerator or freezer, or approximately 1,200 lbs. per unit.
NOTE: Protect the finish of the flooring. Cut a large section of the cardboard carton and place under the product where you are working.
NOTE: Not recommended for installation on carpeted flooring.
GROUNDING THE UNIT
WARNING
Failure to follow these instructions can result in death, fire, or electrical shock.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Electrical Shock Hazard.
GROUNDING THE UNIT (Cont.)
Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
LA TERRE DE L’UNITÉ
AVERTISSEMENT
Le non-respect de ces instructions peut entraîner des risques d’incendies, des chocs électriques ou la mort.
Le cordon d’alimentation de cet appareil est équipé d’une fiche à trois broches (pour une mise à la terre) qui s’adapte à la prise de courant standard à 3 broches (pour une mise à la terre) pour minimiser les risques de chocs électriques par cet appareil.
Faites vérifier la prise murale et le circuit électrique par un électricien qualifié pour s’assurer que le système est correctement mis à la terre.
Dans le cas d’une prise biphasée, l’installateur a la responsabilité et l’obligation de la remplacer par une prise triphasée correctement mise à la terre.
NE COUPEZ PAS OU N’ENLEVEZ PAS, SOUS AUCUN PRÉTEXTE, LA TROISIÈME BROCHE DE MISE À LA TERRE DU CORDON D’ALIMENTATION.
N’UTILISEZ PAS D’ADAPTATEUR POUR BRANCHER LE RÉFRIGÉRATEUR À UNE PRISE BIPHASÉE.
N’UTILISEZ PAS DE RALLONGE AVEC CET APPAREIL.
Risque de choc électrique.
CONEXIÓN A TIERRA DE LA UNIDAD
ADVERTENCIA
Si no se siguen estas instrucciones, se podrá producir la muerte, incendios o descargas eléctricas.
El cable de corriente de este electrodoméstico cuenta con un enchufe de 3 cables (conexión a tierra) que se conecta a un tomacorriente de pared estándar de 3 cables (conexión a tierra) para minimizar el riesgo de posibles descargas eléctricas por parte del mismo.
Contrate a un electricista calificado para que controle el tomacorriente y el circuito eléctrico, a fin de asegurar que el enchufe esté correctamente conectado a tierra.
En caso de contar con un tomacorriente de pared de 2 cables, es su responsabilidad y obligación reemplazarlo por un tomacorriente de pared de 3 cables correctamente conectado a tierra.
NUNCA, BAJO NINGUNA CIRCUNSTANCIA, CORTE NI ELIMINE EL TERCER CABLE (TIERRA) DEL CABLE DE CORRIENTE.
NO USE UN ENCHUFE ADAPTADOR PARA CONECTAR EL REFRIGERADOR A UN TOMACORRIENTE DE 2 PATAS.
NO USE UN PROLONGADOR CON ESTE ELECTRODOMÉSTICO.
Riesgo de Descarga Eléctrica
31-49140-2
13
Installation Instructions - Standard Installation
STEP 1 REMOVE PACKAGING
WARNING
is much heavier at the top than at the bottom – be careful when moving. When using a hand truck, handle from side only.
AVERTISSEMENT
basculement Le produit est beaucoup plus lourd en haut qu’en bas. Il faut être prudent lors des déplacements. Si un diable est utilisé, il faut soulever le réfrigérateur sur le côté
seulement.
ADVERTENCIA
producto es mucho más pesado en su parte superior que en su parte inferior – tenga cuidado al moverlo. Al usar un carro
manual, sosténgalo de costado únicamente.
• Carefully cut banding at the top and bottom, remove outer carton.
• Slide out back corner posts (2).
• Slide carton off top of cabinet.
NOTE: IT IS NOT NECESSARY TO LAY CABINET
DOWN IN ORDER TO REMOVE SKID!
NOTE: DO NOT ATTEMPT TO ROLL UNIT OFF SKID.
Tip Over Hazard. Product
Risque de
Riesgo de Caída El
• The unit is secured to the skid with 4 slotted tie-down straps. Remove the four 5/16” bolts from the base channels in the tie-downs.
• Unit is shipped with two sets of toe kicks. One for Flush Inset (longer) and One for standard installation (shorter). Pick proper toe kick for your installation. Discard other toe
kick.
• Remove toekick, custom handle trim, and wall bracket. Set aside for final installation.
• Lift the unit off the skid with an appliance dolly. Handle from the sides.
• Remove the four 7/16” bolts securing the tie-down brackets to the skid.
STEP 2 INSTALL WATER LINE
WARNING
AVERTISSEMENT
alimentation d’eau potable seulement.
ADVERTENCIA
suministro de agua potable únicamente.
• A cold water supply is required for automatic icemaker operation. The water pressure must be between 40 and 120 p.s.i. (275-827 kPa).
• Route 1/4” OD copper or SmartConnect™ plastic tubing between house cold water line and the water connection location.
• Tubing should be long enough to extend to the front of the unit. Allow enough tubing to accommodate bend leading into the water line connection.
NOTE: The only Monogram approved plastic tubing is supplied in the SmartConnect™ Refrigerator Tubing kits. Do not use any other plastic water supply line because the line is under pressure at all times. Other types of plastic may crack or rupture with age and cause water damage to your home.
SmartConnect™ Refrigerator Tubing Kits are available in the following lengths:
2’ (.6 m) WX08X10002 15’ (4.6 m) WX08X10015 8’ (2.4 m) WX08X10006 25’ (7.6 m) WX08X10025
Connect to potable water supply
only.
Raccordez l’appareil à une
Realice la conexión a un
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line of water.
• Install a shut-off valve between the icemaker water valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be easily accessible.
• Turn on the main water supply and flush debris. Run about a quart of water through the tubing into a bucket. Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in many water supply kits. Before purchasing, make sure a saddle type valve complies with your local plumbing codes.
NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.
14
31-49140-2
Installation Instructions - Standard Installation
STEP 3 INSTALL SIDE PANELS
Skip this step when not using side panels
If you are using 1/4” side panels, they should be insert­ed into the case trim.
STEP 4 INSTALL ANTI-TIP BRACKET
WARNING
The unit is top-heavy and must be secured to prevent the possibility of tipping forward.
AVERTISSEMENT
basculement
en haut et il faut le maintenir en place pour éviter la possibilité de son basculement vers l’avant.
ADVERTENCIA
La unidad es pesada en su parte superior y se deberá asegu­rar a fin de evitar posibles caídas hacia adelante.
• The kit supplied with the unit contains 2 lag bolts and 4 toggles with bolts. The wall bracket will be attached to the wall in 4 places.
• Measure the opening where the unit is to be installed. Mark the center with a vertical line.
• Measure up 81-1/2” (207.01 cm) from the floor. Mark this point on the wall.
• Using a level, draw a horizontal line on the wall at this height.
Tip Over Hazard.
L’appareil ménager est beaucoup plus lourd
Risque de
Riesgo de Caídas
Fasten the panels to the unit with stick-on hook and loop fastener strips before setting unit in place.
• Locate at least 2 studs on the back wall. Mark these points on the horizontal line.
• Place the bottom of the wall bracket with tabs on the horizontal line. Align the center notch on the bracket with the center line on the wall.
Center
Two Additional
Hole Locations at
Ends of Brackets
Wall Studs
• The anti-tip wall bracket has a series of holes. Select 2 holes that match with the located studs. Make sure the holes selected are on the center of the studs. Mark the wall at these points.
Wall Bracket
Line On Wall
31-49140-2
Line on Wall
Center
• Mark an additional hole at each end of the bracket. If one of the studs is closer to the end of the bracket, mark an additional hole towards the center of the bracket.
• Drill 1/2” (1.27 cm) holes into the wall board at the loca­tions marked for the toggles to be mounted (not the stud markings).
• Drill 3/16” (0.47 cm) holes into wooden studs where marked. If steel stud construction, drill 1/2” (1.27 cm) holes into the studs where marked. You will use 2 tog­gles with the metal studs.
15
Installation Instructions - Standard Installation
STEP 4 INSTALL ANTI-TIP BRACKET (cont.)
Install Wall Toggles:
The wall toggles and bolts can be ordered as Service Kit #WR49X10193. Wall toggles are installed in the drywall and metal studs for stability. Install the wall tog­gles as follows:
• Drill 1/2”
(1.27 cm)
holes at the wall markings made in
the holes at the ends of the wall bracket.
• Hold the metal channel flat against the plastic straps and slide the channel through the hole.
Plastic Straps
Metal Channel
• Gently pull back at the ends of the plastic straps to make the channel rest flush behind the wall.
• Hold the ends of the straps in one hand and slide the plastic cap along the straps until the flange of the cap is flush with the wall.
Cap
Install Screws and Bolts:
• Have someone hold the wall bracket centered in place with each of the holes aligned with the correct opening in the bracket and level with the horizontal line.
• Insert the lag screws through the bracket and into the stud. Tighten with a wrench.
Wood Stud
Lag Screw
Anti-Tip Wall Bracket
Insert the bolts into the toggle by hand until snug. Tighten with a wrench.
Drywall or Steel Stud
Bolt
• Place your thumb between the plastic straps and bend up and down to snap the straps off at the wall.
Wall Toggle
Anti-Tip Wall Bracket
16
31-49140-2
Installation Instructions - Standard Installation
STEP 4 INSTALL ANTI-TIP BRACKET (cont.)
Remove Grilles for Access to Anti-Tip Locking Hooks
Fresh Food Unit
• Open the access door.
• Remove the 4 screws from the grille on the right and 3 screws from the grille on the left.
• Pull the bottom of the grilles forward, down and out to remove.
Screws Screws
Freezer Unit
• Open the access door.
• Remove the 4 screws from the grille on the right and 3 screws from the grille on the left.
• Pull the bottom of the grille forward, down and out to remove.
Power Cord
Locate the power cord inside the left cavity. If it has not been adjusted so the plug is easily accessible, do so now.
Move Unit into Final Position
• Move appliance toward its final installed location. Align the tabs on the wall bracket with the openings in the back of the unit.
• The unit has “L” bolts in the upper left and right cor­ners inside of the access compartment. These bolts will interlock with the wall bracket and secure the unit using the washers and hair pin cotters in the hardware kit once the unit has been leveled and is in the final position.
31-49140-2
Screws Screws
17
Installation Instructions - Standard Installation
STEP 5 LEVEL UNIT
All models have 4-point leveling. The front is support­ed by leveling legs; the rear is supported by adjustable wheels. Both are accessible from the front of the unit.
• To level the back of the unit, turn the 7/16” hex nut located above the front wheels. Turn clockwise to raise or counterclockwise to lower the unit.
• For front leveling, use a 1-1/4” open-end wrench.
• Adjust height of unit to match installation cutout opening 84-1/2” level and plumb with cabinetry.
The rear leveling wheels and front leveling legs are limited to a maximum height adjustment of 1” (2.54 cm). If the installation requires more than 84-1/2” the unit on a sheet of plywood or runners. Cabinetry trim could also be added across the top of the opening to shorten the opening. If you attempt to raise the unit more than 1” (2.54 cm), you will damage the front leveling legs and the rear leveling wheels.
(214.63 cm)
(214.63 cm)
height, the installer should elevate
. The unit should be
STEP 6 SECURE UNIT TO WALL
• The “L” rods can be found in the upper left and right corners of the unit in the access compartment. Look through the access compartment to make sure the rods line up with the anti-tip bracket.
• There are 2 washers and a hair pin cotter per rod. Remove the washers and hair pin cotter from the end of the rod.
• Rotate and move the “L” rod into the slot in the anti-tip bracket tab. Once it is in the slot, rotate the “L” rod so the hook portion is pointing down. The holes at the front end of the rod should be in a vertical position. Do this to both sides.
• Pull out on the end of the rod to make sure it is secure in the bracket.
• Locate the hole on the rod that is closest to the unit. A hair pin cotter will be put through this hole to secure the rod. If this hole appears to be too far away for a snug fit against the unit, add the washers one at a time until the pin will fit tightly into the hole.
• Align the straight section of the pin with the hole from the underside of the rod. Push the pin up until it snaps into position. Pliers may be used. NOTE: The hair pin cotter must be vertical when this step is completed to ensure the “L” rod is engaged in the bracket.
• Check the rod for tightness by pulling forward. If the rod moves, remove the hair pin cotter and place another washer on the rod. Reinsert the pin.
• Replace the grille panel.
Wall Bracket
“L” Rod
“L” Rod
18
31-49140-2
Installation Instructions - Standard Installation
STEP 7 ADJUST DOOR SWING
NOTE: This appliance has a 3-position door stop.
When space does not allow the door to swing open fully to 115°, you may change the door swing to a 90° opening. A 130° door swing is available for stan­dard installation only. Skip this step if door open-
ing is satisfactory for your installation situation.
Pin Location
for 90°
Door Swing
• Open the hood to view the top hinge. Note the door stop pin locations. The pin is factory-installed in the 115° position.
• Close the door. Use pliers to unscrew the door stop and reinstall in the 90 degree or 130 degree position.
Pin Location
for 130°
Door Swing
Pin Location
as Shipped
for 115°
Door Swing
STEP 8 INSTALL GRILLE PANEL
• Raise the access panel to the stop position.
• Loosen the screws on the side trim behind the frame. Remove the bottom trim.
• Slide the panel over the metal baker panel and into the trim.
• If necessary, tap with a wood block until the panel slips under the top trim piece.
• Reassemble the bottom trim. Tighten the screws.
• Adjust the hinge spring to accommodate the panel weight, if necessary.
31-49140-2
19
Installation Instructions - Standard Installation
STEP 9 INSTALL FRAMED PANELS
Use Front Holes
to Secure Trim
Use Rear Holes
to Secure Handle
Install Door Panel:
• Open the door to 90°. Remove the 6 Phillips head screws from the door handle.
• Remove the handle. Retain all screws.
• Remove the 6 screws holding the trim, lift off the trim. Retain the screws.
• Slide the framed panel into the door trim.
Right hand models shown. Use the same instruc­tions for left hand models. IF YOU ARE INSTALLING OVERLAY PANELS, GO TO STEP 10A.
Handle Trim
Standard supplied handle shown
in 1/4”(0.63 cm) panel position.
• There are two sets of holes in the handle side trim. Replace the handle side trim by installing the original screws in the FRONT screw holes.
• Secure the handle to the door using the REAR screw holes.
Door Trim
Door
20
Installation Instructions - Standard Installation
STEP 9A INSTALL OVERLAY PANELS
Use Front Holes to Secure Handle
Use Rear Holes
to Secure Trim
Install Door Panel:
• Open the door to 90°. Remove the 6 Phillips head screws from the door handle.
• Remove the handle. Retain all screws.
• Remove the 6 screws holding the trim, lift off the trim. Retain the screws.
• Slide the overlay panel into the door trim.
Right hand models shown. Use the same instruc­tions for left hand models.
Door Trim
Handle Trim
Door
Move
Forward
For 3/4"
Panel
Supplied handle shown
in the overlay panel position.
• There are two sets of holes in the handle side trim. Replace the handle side trim by installing the original screws in the REAR screw holes.
• Secure the handle to the door using the FRONT screw holes.
Custom Handles
If you are using custom handles, the handle must be properly secured to the panel before sliding the panel into the trim.
• The cabinet manufacturer will supply the custom han­dle and hardware.
• Secure the door trim using new handle side trim. Discard the supplied handle.
21
Installation Instructions - Standard Installation
STEP 10 CONNECT WATER SUPPLY
(FREEZER MODELS ONLY)
WARNING
AVERTISSEMENT
alimentation d’eau potable seulement.
ADVERTENCIA
tro de agua potable únicamente.
• Locate and bring the tubing to the front of the cabinet.
• Turn the water on to flush debris from the line. Run about a quart of water through the tubing into a bucket, then shut off the water.
Copper Tubing:
• Slip a 1/4” nut and ferrule (provided) over both ends of the copper tubing. Insert the tube into the union fitting on the unit and tighten the nut to the union.
• Turn on the water to check for leaks.
SmartConnect™ Tubing: NOTE: The only Monogram-approved plastic tubing is
supplied in the SmartConnect™ Refrigerator Tubing kits. Do not use any other plastic water supply line because the line is under pressure at all times. Other types of plastic may crack or rupture with age and cause water damage to your home.
• Insert the molded end of the tubing into the appliance or freezer connection. Tighten the compression nut until it is just hand-tight.
• Tighten one additional turn with a wrench. Overtightening can cause leaks!
• Turn on the water to check for leaks.
NOTE: Make sure excess tubing length does not interfere with the toekick installation.
Connect to potable water supply
only.
Raccordez l’appareil à une
Realice la conexión a un suminis-
House
Water Supply
Freezer
Water Supply
STEP 11 START ICEMAKER (FREEZER MODELS ONLY)
CAUTION
of the ejector mechanism, or with the heating element (located on the bottom of the icemaker) that releases the cubes. Do not place fingers or hands on the automatic ice making mechanism while the freezer is plugged in.
ATTENTION
mobiles du mécanisme d’éjection, ou l’élément chauffant (situé dans le bas de la machine à glaçons) qui libère les glaçons. Ne placez pas les doigts ou les mains sur le mécanisme de production de glace automatique lorsque le congélateur est branché dans la prise électrique.
PRECAUCIÓN
movimiento del mecanismo expulsor o con el elemento de calefacción (ubicado en la parte inferior de la máquina de hielos) que expulsa los cubos. No coloque los dedos ni las manos en el mecanismo de la máquina de hielos automáti­ca mientras el freezer se encuentre enchufado.
Power Switch
• The icemaker will begin operation automatically.
• Be sure nothing interferes with the sweep of the feeler arm.
• Discard the first full bucket of ice cubes.
• To turn the icemaker off, slide the switch to OFF.
Avoid contact with the moving parts
Évitez tout contact avec les pièces
Evite el contacto con las partes en
Icemaker
Feeler Arm
STEP 12 INSTALL TOEKICK
• Locate Supplied toekicks (shipped taped to the side of the appliance). The unit will be shipped with two sets of toekicks. The shorter toe kick should be used for standard installation. Discard the other set of toe kicks. Install the toekick assembly with the 2 screws provided, adjust to the desired height and tighten the screws.
IMPORTANT: A custom toekick can be installed to match or complement the surrounding cabinetry but can NOT cover the horizontal vent slots of the factory toe kick.
22
Instructions for Flush Installation
23
Design Guide - Flush Installation
THE INSTALLATION SPACE
39”
Finished Width
4-5/16”
5-1/2”
Electrical
85”
Finished
Opening
9”
26-3/16” Minimum
Cutout Depth
3-1/2” 3-1/2”
7” 7”
3-1/2” 3-1/2”
Cold Water
Supply
3-1/2”
Area
Water And Electrical Locations Electrical and water supply must be located as shown.
Cutout Depth Beneath a Soffit: When installed beneath a soffit, the soffit cannot exceed the 26-3/16” (66.52 cm) installation depth shown.
The Cutout Depth Must Be 26-3/16” (66.52 cm)
Wooden cleats are required for flush installation. See
Side Cleats on page 30.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4” O.D. copper tubing or QuickConnect™ kit between the cold water line and water connection location, long enough to extend to the front of the unit. Installation of an easily accessible shut-off valve in the water line is required.
Wall View
75-1/2” From
Floor to Bottom
of Electrical Area
DIMENSIONS AND CLEARANCES
35"
Case Width
*83-1/2"
at
Rear
Depth Including Handles 26-7/8"
Product Clearances
These units are equipped with a 3-position door stop. The factory set 115° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
90° Door Swing
4” Minimum
90° Door Swing
90°
to a Wall
23-7/8” Case Behind Frame
38-3/4”
For a 90° door swing, allow 4” (10.16 cm) minimum clearance to a wall for framed and stainless steel models. If the 90° doorstop position is used, pan access is maintained but pan removal is restricted.
25-3/8" Case Depth
* Shipping height. The
product can be adjusted to fit into a cutout that
*84" From Floor to Top Frame
is 85” (215.9 cm) max. height. Use leveling legs and wheels for a maximum 1” (2.54 cm) height adjustment.
38-3/4" Frame to Frame Width
115° Door Swing
24
CLEARANCES
Design Guide - Flush Installation
4" Min. to Wall
1"
90° Door Swing
38-3/4"
15"
Min. to
Wall
115° Door
Swing
115° Door
Swing
15"
Min. to
Wall
These units are equipped with a 3-position door stop. The factory set 115° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
When Installed into a corner:
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door swing product, a 1” (2.54 cm) clearance between the units is required. Order ZUG2 Unified Grille Panel Kit for one continuous grille panel.
Allow 15” (38.1 cm) for a full 115° door swing and pan removal. Allow 4” (10.16 cm) min. clearance when door swing is adjusted to a 90° opening for pan access, but pan removal is restricted.
INSTALLATION
ZUG2 Unified Grille Panel Kit
• If you are installing two units, side by side, the installation space must be 75” (190.5 cm) wide.
Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width.
• The water and electrical locations for each product must be
located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Note: When implementing a dual installation, the factory installed standard case trim should be used on the handle side of each unit and the supplied flush case trim should be used on the hinge side of each unit.
85" Finished Opening
75" Finished Width
4-5/16"
Electrical
5-1/2"
9"
26-3/16" Minimum
Cutout Depth
Cold Water
Supply
3-1/2" 3-1/2" 3-1/2" 3-1/2"
7"
3-1/2"
7-1/2" 7-1/2"
3-1/2" 3-1/2" 3-1/2"
9"
Cold Water
Supply
3-1/2"3-1/2"
5-1/2"
24-3/16"
Electrical
Area
Wall View
7"
CUSTOM HANDLE DESIGN GUIDE
Custom handles must be used for flush installation. For custom handle installation, counterbore holes in rear of decorative panels must ensure 1/2” (1.27 cm) material thickness remains for handle support. NOTE: The counterbore must not exceed 1” (2.54 cm) in diameter.
1/2”
1/4”
3/4”
Minimum distance from handle side edge to handle center should be 3-1/2” (8.89 cm)as shown.
7/8"
0.85"
1/2"
25
3-1/2”
Design Guide - Flush Installation
1/2” (1.27 cm) OVERLAY PANEL DIMENSIONS
For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4” (.63 cm) thick backer panel which slides into the trim. A spacer panel
0.10” (0.25 cm) thick must be placed between the overlay and backer panel.
Assemble the panels with glue and screws:
• Center the spacer panel on the backer panel, left to right and top to bottom. Secure the panels with glue.
• Refer to the following chart for locating the backer panel to the over­lay panel. Secure the overlay panel to the backer panel with glue and screws. Screws must be countersunk into the backer panel.
Hinge Side
C
Door Back
Fresh Food Back
Backer with Overlay Panel Assembly
Door
1/4"
Backer
Panel
.250” + .10” + .50” = .850” Total Panel Thickness (0.635 cm + 0.254 cm + 1.27 cm = 2.159)
Grille Back
C
1/2"
Overlay
Panel
.10"
Spacer
D
A
IMPORTANT NOTE: Maximum total weight for the assembled panels:
B
Fresh food door panel – 75 lbs. (34.02 cm)
Grille Panel – 18 lbs. (8.16 cm)
A B
ABCD
Door Panel 2-1/16”
(5.24 cm)
Grille Panel 2-1/16”
(5.24 cm)
Panel Dimensions
Fresh Food Door Grille
1/4” (0.63 cm) Backer Panel
.10” (0.25 cm) Spacer Panel
1/2” (1.27 cm) Overlay Panel
69-5/16” x 33-7/8”
(176.05 cm x 86.04 cm)
67-15/16” x 32-1/2”
(172.56 cm x 82.55 cm)
69-3/4” x 38”
(177.16 cm x 96.52 cm)
D
2-1/16”
(5.24 cm)
2-1/16”
(5.24 cm)
3/16”
(0.47 cm)
1-7/16”
(3.65 cm)
8-7/8” x 33-7/8”
(22.54 cm x 86.04 cm)
7-5/8” x 32-1/2”
(16.37 cm x 82.55 cm)
10-7/16” x 38”
(26.51 cm x 96.52 cm)
1/4”
(0.63 cm)
1/8”
(0.31 cm)
26
Design Guide - Flush Installation
3/4” (1.9 cm) DECORATIVE PANEL DIMENSIONS
For a more custom appearance, overlay panels may be installed to give a flush appearance with surrounding cabinets. The overlay panel must be 3/4” (1.9 cm) thick. Panel attaches to included brackets to provide mounting to the appliance door.
NOTE: We recommend that decorative panels have inside corners and edges rounded or beveled by cabinet maker to avoid sharp edges on the panels. Edges to be treated should include the top, bottom and hinge side edges.
38"
Grille Panel
Door Panel
10-7/16"
69-3/4"
IMPORTANT NOTE: Maximum total weight for the assembled panels:
• Door panel – 67 lbs. (30.39 kg)
• Grille Panel – 18 lbs. (8.16 kg)
WARNING
Improper installation can lead to a finger pinch point hazard between the side door trim and the cabinets when operating the door, especially with children. To minimize this risk you must follow the installation instructions for cabinet dimensions, trim assembly, and door stop angle.
AVERTISSEMENT
doigts
Une installation incorrecte peut poser un risque de coincement de doigts entre la garniture de porte latérale et les armoires en actionnant la porte, en particulier pour les enfants. Pour réduire ce risque, vous devez suivre les instructions d’installation relatives aux dimensions d’armoire, au montage des garnitures
et à l’angle de l’arrêt de porte.
ADVERTENCIA
el Borde de la Puerta
Una instalación inadecuada puede conducir a riesgos de pellizcos de dedos entre el borde lateral de la puerta y los gabinetes al utilizar la puerta, especialmente con los niños. A fin de minimizar este riesgo, usted deberá seguir las instrucciones de instalación para dimensiones de gabinetes, ensambles de bordes y esquinas de detención de puertas.
Door Trim Pinch Point Hazard
Risque de pincement de
Riesgo de Lastimadura con
27
Design Guide - Flush Installation
3/4” (1.9 cm) RAISED DOOR PANEL ROUTING
For 3/4” (1.9 cm) raised door panel, routing is required. The router depth is 1/4” (0.63 cm) all the way around the panel back. Additional panel width reductions are required per the diagrams below. This will create a “picture frame” routing that will slide onto the attached door trim.
TOP DETAIL TOP
3/4”
11/32”
1/4”
1/4”
7/16”
NOTE: Routed areas should be finished as they may be visible when assembled.
Front
Back
Back
BOTTOM
3/4” PANEL SIDE VIEW
(AFTER ROUTING)
Front
LEFT SIDE
DETAIL
LEFT SIDE
1/4”
CORNER VIEW SHOWING
“PICTURE FRAME” ROUTING
DETAIL BOTTOM
DETAIL RIGHT
SIDE
ROUTER DEPTH 1/4” ROUTER DEPTH 1/4”
2-1/16” 2-1/16”
Front
RIGHT
SIDE
Back
3/4” PANEL BOTTOM VIEW
(AFTER ROUTING)
NOTE: For panels constructed with rails and stiles (5-panel), the minimum width is 3” (7.62 cm) for rails and 4” (10.16 cm) for stiles.
28
Design Guide - Flush Installation
3/4” (1.9 cm) RAISED GRILLE PANEL ROUTING
For 3/4” (1.9 cm) raised grille panel, routing is required. The router depth is 1/4” (0.63 cm) all the way around the panel back. Additional panel width reductions are required per the diagrams below. This will create a “picture frame” routing that will slide onto the attached grille trim.
DETAIL TOP
TOP
NOTE: Routed areas should be finished as they may be visible when assembled.
Front
Back
Back
Front
1-7/16”
ROUTER DEPTH 1/4”
BOTTOM
3/4” PANEL SIDE VIEW
(AFTER ROUTING)
LEFT SIDE
DETAIL
LEFT SIDE
CORNER VIEW SHOWING
“PICTURE FRAME” ROUTING
1/8”
DETAIL BOTTOM
DETAIL RIGHT
SIDE
ROUTER DEPTH 1/4” ROUTER DEPTH 1/4”
2-1/16” 2-1/16”
Front
RIGHT
SIDE
Back
3/4” PANEL BOTTOM VIEW
(AFTER ROUTING)
NOTE: For panels constructed with rails and stiles (5-panel), the minimum width is 3” (7.62 cm) for rails and 4” (10.16 cm) for stiles.
29
Design Guide - Flush Installation
3/4” (1.9 cm) RAISED DOOR PANEL ROUTING FOR UNIFIED INSTALLATION
Back
TOP DETAIL TOP
3/4”
11/32”
1/4”
Front
1/4”
DETAIL BOTTOM
1/4”
11/32”
NOTE: Routed areas should be finished as they may be visible when assembled.
Front
Back
CORNER VIEW SHOWING
“PICTURE FRAME” ROUTING
BOTTOM
3/4” PANEL SIDE VIEW
(AFTER ROUTING)
DETAIL HINGE
SIDE
HINGE
SIDE
ROUTER DEPTH 1/4”
2-1/16”
3/4” PANEL BOTTOM VIEW
(AFTER ROUTING)
DETAIL HANDLE
SIDE
3/4”
Front
HANDLE
SIDE
Back
30
Loading...