OVERALL DIMENSIONS
36" (91.5)
9 3/4"
(24.8)
25 3/4" (65.4)
23 7/8" (60.7)
2"
(5.1)
44 1/2"
(113.0)
*73 1/4"
(186.1)
*84"
(213.4)
*26"
(66.0)
*28"
(71.1)
*24"
(61.0)
*3 3/4"
(9.5)
SIDE VIEWFRONT VIEW
*83 1/2"
(212.1)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
36" (91.5)
ZICS360NHRHGE Monogram® 36" Built-In Bottom-Freezer Refrigerator
25 3/4" (65.4)
23 7/8" (60.7)
SPECIFICATIONS
Overall Width 36" (91.4 cm)
Overall Height 84" (213.4 cm)
Overall Depth 25 3/4" (65.4 cm)
Door Clearance 36 3/4" (93.4 cm)
Cutout Width 35 1/2" (90.2 cm)
Cutout Height 83 1/2" - 84 1/2"
(212.1 - 214.6 cm)
Cutout Depth 24" (61 cm)
Plumbing Requirements 1/4" OD copper
tubing or GE
SmartConnect kit
Shipping Weight 640 lb (290.3 kg)
9 3/4"
(24.8)
44 1/2"
*73 1/4"
(186.1)
(113.0)
*28"
(71.1)
*24"
(61.0)
*84"
(213.4)
*26"
(66.0)
* Shipping height . Use leveling legs and wheels for maximum
1" height adjustment from shipping height.
35" (89.0)
Case width
** Allow
clearance for 130˚
door swing
2"
(5.1)
*3 3/4"
(9.5)
25" (63.5) min
SIDE VIEWFRONT VIEW
*83 1/2"
(212.1)
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply
is required. An inidividual properly grounded
branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
TOP VIEW
36 3/4"
(93.4)
** Allow 4" (10.2) min
clearance to a wall
for 90˚ door swing
** These refrigerators are equipped with a 2-position door stop. The factory-set 130° door
swing can be adjusted to 90° if clearances to adjacent cabinets or walls is restricted. Allow
a 15" minimum clearance to wall for pan removal. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimension may vary due to manufacturing tolerances.
Product Specification Created 6/14
24" (61.0)
2"
(5.1)
4"
(10.2)
7/16"
(1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
E
6"
(15.2)
10"
(25.4)
SIDE VIEW
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
10" (25.4)
WATER
FRONT VIEW
GE Monogram® 36" Built-In Bottom-Freezer Refrigerator
ZICS360NHRH
STANDARD INSTALLATION
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
*Trim will overlap
additional 7/16"
(212.1-214.6)
ANTI-TIP BRACKET
35 1/2" (90.2)
E
10"
(25.4)
5"
(12.7)
FRONT VIEW
A
WATER
3 1/2"
(9.0)
6"
(15.2)
B
(12.7)
81 1/2"
(207.0)
5"
From floor
to bottom
of electrical
3 1/2"
(8.9)
75"
(190.5 )
area
(10.2)
Use two
additional hole
locations at end
of brackets
4"
24" (61.0)
2"
(5.1)
SIDE VIEW
C
L
Bracket
mounted
into vertical
wall studs
Ensure holes
selected are
centered on
the studs
Wall
Studs
10" (25.4)
WATER
7/16"
Trim overlap
(1.1)
NOTES
A
Mounting the junction
box in this location will
also allow for front
accessability through
access panel.
B
Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the antitip system you must use
the product installation
instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts
are used in wood studs.
• In installation opening,
measure 81 ½” from
floor and draw a
horizontal line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32.5”
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be
centered left to right in
opening with bottom of
bracket on the horizontal
line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
See Installation
Instructions for detailed
instructions.
Product Specification Created 6/14