OVERALL DIMENSIONS
ZHU36RDJBBMONOGRAM 36" INDUCTION COOKTOP
SPECIFICATIONS
Overall Width 36" (91.4 cm)
Overall Depth 20 3/8" (51.8 cm)
Overall Height 4 5/8" (11.8 cm)
Cut-out Width 33 7/8" (86.0 cm)
Cut-out Depth 19 1/8" (48.6 cm)
Conduit Length 48" (122 cm)
Electrical Rating
Recommended Circuit
Breaker Size
Net Weight 48 lbs. (21.8 kg)
Approx. Shipping
Weight
11,600W at 240V/60Hz
10,100W at 208V/60Hz
50 Amps
58 lbs. (27.6 kg)
1 1/16"
(2.7)
Cutout
overlap
20 3/8"
(51.8)
36" (91.4)
33 7/8" (86.0)
Cutout width
TOP VIEW (SHOWING CUTOUT OVERLAP)
R 1/2" (1.3)
All Four Corners
5/8"
(1.6)
Cutout
overlap
19 1/8"
(48.6)
Cutout
depth
OPTIONAL ACCESSORIES
Precision Cooking Kit JXSOUSV1
Flush-Mount Kit JXFLUSH1
ATTENTION ELECTRICIAN:
This cooktop is provided with a 48"
flexible conduit and must be hard wired
(direct wired) into an approved junction
box and be properly grounded. It is not
permitted to use a “plug and receptacle”
type installation on this cooktop.
Use a two-wire, three conductor 208/240
VAC, 60 Hertz electrical system. A white
(neutral) wire is not needed for this
cooktop
For more details refer to the installation
instructions for this product.
3 1/16"
(7.8)
1 1/8"
(2.9)
3/4"
(1.9)
FRONT VIEW
Front of Cooktop
18 15/16" (48.1)
Baffle
33 3/4" (85.7)
SIDE VIEW
3/16"
(0.5)
4 7/16"
(11.3)
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimensions may vary due to manufacturing tolerances.
Product Specification Revised 3/18
ZHU36RDJBBMONOGRAM 36" INDUCTION COOKTOP
INSTALLATION
B
E
Locate electrical junction box
at least
A
16" (40.6) min
To electrical junction box
16" below the countertop
F
36 " (91.4)
Cabinet base
COUNTERTOP CUT-OUT
DIMENSIONS
33 7/8" (86.0) min
34" (86.3) max
Cutout width
FRONT
TOP VIEW OF CUTOUT SIDE VIEW
Dimensions in parentheses are in centimeters unless otherwise noted.
C
19 1/8" (48.6) min
19 1/4" (48.9) max
Cutout depth
15"
D
(38.1)
min
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
3"
(7.6) min
DRAWER
SIDE VIEWFRONT VIEW
ADA INSTALLATION
5"
(12.7) min
H
13"
(33.0) max
G
NOTES
A
Wall coverings, countertop
NOTES
and cabinets surrounding
cooktop must be able to
withstand temperatures of
up to 200ºF.
B
Minimum 30" clearance
from countertop to
unprotected overhead
surfaces, when no
ventilation hood or
microwave oven is installed.
C
When using a ventilation
hood or microwave
oven above the cooktop,
see hood or microwave
installation instructions
for minimum overhead
clearance dimensions.
D
Minimum 15" of clearance
from countertop to nearest
overhead surface on both
sides of cooktop. Make sure
to include any lighting rail
covers in calculation.
E
Minimum 2" distance from
edge of cutout to nearest
adjacent side wall below
upper cabinets.
F
Install an approved
junction box where it can
be easily reached through
the front of the cabinet
where the cooktop is
located. IMPORTANT: For
serviceability, the junction
box must be located where
it will allow considerable
slack in the 48" long
conduit.
G
Maximum 13" depth of
unprotected overhead
surfaces, when no
ventilation hood or
microwave oven is installed.
H
For Americans with
Disabilities Act (ADA)
forward approach
installation: Minimum 5"
clearance between the
top of the countertop
and the enclosure. The
enclosure must be made
of at least 1/4" thick wood
material, and must have
an access panel installed
in order to provide access
to the junction box and
hold-down brackets, and
to allow for service of the
cooktop.
For more details refer to the
installation instructions for this
product.
Product Specification Revised 3/18