Monogram ZHU36RDJBB Specifications

OVERALL DIMENSIONS
ZHU36RDJBBMONOGRAM 36" INDUCTION COOKTOP
SPECIFICATIONS
Overall Width 36" (91.4 cm)
Overall Depth 20 3/8" (51.8 cm)
Overall Height 4 5/8" (11.8 cm)
Cut-out Width 33 7/8" (86.0 cm)
Cut-out Depth 19 1/8" (48.6 cm)
Conduit Length 48" (122 cm)
Electrical Rating
Recommended Circuit Breaker Size
Net Weight 48 lbs. (21.8 kg)
Approx. Shipping Weight
11,600W at 240V/60Hz
10,100W at 208V/60Hz
50 Amps
58 lbs. (27.6 kg)
1 1/16"
(2.7)
Cutout
overlap
20 3/8"
(51.8)
36" (91.4)
33 7/8" (86.0)
Cutout width
TOP VIEW (SHOWING CUTOUT OVERLAP)
R 1/2" (1.3)
All Four Corners
5/8"
(1.6)
Cutout
overlap
19 1/8"
(48.6)
Cutout
depth
OPTIONAL ACCESSORIES
Precision Cooking Kit JXSOUSV1
Flush-Mount Kit JXFLUSH1
ATTENTION ELECTRICIAN:
Use a two-wire, three conductor 208/240 VAC, 60 Hertz electrical system. A white (neutral) wire is not needed for this cooktop
For more details refer to the installation instructions for this product.
3 1/16"
(7.8)
1 1/8"
(2.9)
3/4"
(1.9)
FRONT VIEW
Front of Cooktop
18 15/16" (48.1)
Baffle
33 3/4" (85.7)
SIDE VIEW
3/16"
(0.5)
4 7/16"
(11.3)
Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimensions may vary due to manufacturing tolerances.
Product Specification Revised 3/18
ZHU36RDJBBMONOGRAM 36" INDUCTION COOKTOP
INSTALLATION
B
E
Locate electrical junction box
at least
A
16" (40.6) min
To electrical junction box
16" below the countertop
F
36 " (91.4)
Cabinet base
COUNTERTOP CUT-OUT DIMENSIONS
33 7/8" (86.0) min
34" (86.3) max
Cutout width
FRONT
TOP VIEW OF CUTOUT SIDE VIEW
Dimensions in parentheses are in centimeters unless otherwise noted.
C
19 1/8" (48.6) min 19 1/4" (48.9) max
Cutout depth
15"
D
(38.1)
min
1 3/4" (4.5) min
Clearance between the rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
3"
(7.6) min
DRAWER
SIDE VIEWFRONT VIEW
ADA INSTALLATION
5"
(12.7) min
H
13"
(33.0) max
G
NOTES
A
Wall coverings, countertop
NOTES
and cabinets surrounding cooktop must be able to withstand temperatures of up to 200ºF.
B
Minimum 30" clearance
from countertop to unprotected overhead surfaces, when no ventilation hood or microwave oven is installed.
C
When using a ventilation
hood or microwave oven above the cooktop, see hood or microwave installation instructions for minimum overhead clearance dimensions.
D
Minimum 15" of clearance
from countertop to nearest overhead surface on both sides of cooktop. Make sure to include any lighting rail covers in calculation.
E
Minimum 2" distance from
edge of cutout to nearest adjacent side wall below upper cabinets.
F
Install an approved
junction box where it can be easily reached through the front of the cabinet where the cooktop is located. IMPORTANT: For serviceability, the junction box must be located where it will allow considerable slack in the 48" long conduit.
G
Maximum 13" depth of
unprotected overhead surfaces, when no ventilation hood or microwave oven is installed.
H
For Americans with
Disabilities Act (ADA) forward approach installation: Minimum 5" clearance between the top of the countertop and the enclosure. The enclosure must be made of at least 1/4" thick wood material, and must have an access panel installed in order to provide access to the junction box and hold-down brackets, and to allow for service of the cooktop.
For more details refer to the installation instructions for this product.
Product Specification Revised 3/18
Loading...
+ 3 hidden pages