OVERALL DIMENSIONS
ZEU36RSJSSMONOGRAM 36" TOUCH CONTROL ELECTRIC COOKTOP
SPECIFICATIONS
Overall Width 36 1/8" (91.5 cm)
Overall Depth 20 7/8" (53.0 cm)
Overall Height 6" (15.2 cm)
Cut-out Width 33 7/8" (86.0 cm)
Cut-out Depth 19 1/8" (48.6 cm)
Conduit Length 48" (122 cm)
Electrical Rating
Recommended Circuit
Breaker Size
Net Weight 45 lbs. (20.5 kg)
Approx. Shipping Weight 55 lbs. (25.0 kg)
10,800W at
240V/60Hz
8,100W at 208V/60Hz
50 Amps
1 1/16"
(2.7)
Cutout
overlap
20 7/8"
(53.0)
36 1/8" (91.5)
33 7/8" (86.0)
Cutout width
TOP VIEW (SHOWING CUTOUT OVERLAP)
3/16"
(0.5)
5/8"
(1.6)
Cutout
overlap
19 1/8"
(48.6)
Cutout
depth
ATTENTION ELECTRICIAN:
This cooktop is provided with a 48”
flexible conduit and must be hard wired
(direct wired) into an approved junction
box and be properly grounded. It is not
permitted to use a “plug and receptacle”
type installation on this cooktop.
Use a two-wire, three conductor
208/240V AC, 60 Hertz electrical system.
A white (neutral) wire is not needed for
this cooktop.
The cooktop must be installed in a circuit
that does not exceed 125V AC nominal to
ground.
For more details refer to the installation
instructions for this product.
3 1/16"
(7.8)
1 1/8"
(2.9)
15 3/4" (40.0)
33 3/4" (85.7)
FRONT VIEW
Front of Cooktop
3/4"
(1.9)
1 1/4"
(3.2)
18 15/16" (48.1)
5 1/16"
(12.9)
SIDE VIEW
Dimensions in parentheses are in centimeters unless otherwise noted.
Actual product dimensions may vary due to manufacturing tolerances.
5 3/16"
(14.8)
2 3/8"
(6.0)
Product Specification Revised 1/18
ZEU36RSJSSMONOGRAM 36" TOUCH CONTROL ELECTRIC COOKTOP
STANDARD INSTALLATION
B
E
A
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
C
15"
D
(38.1)
min
F
36 " (91.4)
Cabinet base
COUNTERTOP CUT-OUT
DIMENSIONS
33 7/8" (86.0) min
34" (86.3) max
Cutout width
FRONT
TOP VIEW OF CUTOUT SIDE VIEW
Dimensions in parentheses are in centimeters unless otherwise noted.
B
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
19 1/8" (48.6) min
19 1/4" (48.9) max
Cutout depth
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
8 1/4"
(21.0) min
5"
(12.7) min
DRAWER
SIDE VIEWFRONT VIEW
ADA INSTALLATION
6 1/2"
(16.5) min
H
13"
(33.0) max
G
NOTES
A
Wall coverings, countertop
NOTES
and cabinets surrounding
cooktop must be able to
withstand temperatures of
up to 200°F.
B
Minimum 30" clearance
from countertop to
unprotected overhead
surfaces, when no
ventilation hood is
installed.
C
When using a ventilation
hood above the cooktop,
see hood installation
instructions for minimum
overhead clearance
dimensions.
D
Minimum 15" of clearance
from countertop to
nearest overhead surface
on either side of cooktop.
Make sure to include any
lighting rail covers in
calculation.
E
Minimum 2" distance from
edge of cutout to nearest
adjacent side wall below
upper cabinets.
F
Install an approved
junction box where it can
be easily reached through
the front of the cabinet
where the cooktop is
located. IMPORTANT:
For serviceability, the
junction box must be
located where it will allow
considerable slack in the
48" long conduit.
G
Maximum 13" depth of
unprotected overhead
surfaces, when no
ventilation hood is
installed.
H
For Americans with
Disabilities Act (ADA)
forward approach
installation: Minimum
6-1/2" clearance between
the top of the countertop
and the enclosure. The
enclosure must be
made of at least 1/4"
thick wood material, and
must have an access
panel installed in order
to provide access to the
junction box and holddown brackets, and to
allow for service of
the cooktop.
Product Specification Revised 1/18