Monogram ZDP484NGPSS Specsheet

RANGE WITH 6 BURNERS, GRILL AND GRIDDLE
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Professional ranges oer a number of choices in size and cooktop configurations.
All Professional Ranges are factory set for natural or liquid propane gas. The correct model should be ordered for the installation situation.
35 1/4"
NOTE
Conversion kits are included with the range if the wrong gas type was ordered. High Altitude kit, WB28K10553 for operation above 3,000 feet (for Natural and LP gas models), is also available. The kits must be installed by a qualified service technician at additional cost.
INSTALLATION INFORMATION
Before installing, consult installation instructions packed with product or online at Monogram.com for current dimensional data.
A 48" or 54" wide professional vent hood with a minimum 1200 CFM is recommended for installation over this range.
to
36 3/4"
height
28 1/4"
Depth to front of door
ZDP484NGPSS (NATURAL GAS)MONOGRAM 48" DUAL-FUEL PROFESSIONAL
3 1/4" to 4 3/4"
Toekick/leg
height
ADVANCE PLANNING
Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 18"
minimum clearance between countertop and cabinet bottom.
• Clearance between range and side wall or combustible
material must be at least 12" on each side.
• Installation must conform with local codes. In the
absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1-1990.
WARNING
Installations without a hood require 48" minimum to combustibles. A custom hood installation with exposed horizontal combustible surfaces must have an Auto-On feature. Refer to hood installation instructions for specific hood clearances.
The surface of the entire back wall above the range and below the hood must be covered with a non­combustible material such as metal, ceramic tile, brick, marble or other stone.
13" max.
18" min.
12" minimum to adjacent wall
48" minimum to combustibles
Non-Combustible
Material
12" minimum
each side
48" min.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall on each side.
Working areas adjacent to the rangetop should have 18" minimum clearance between countertop and the bottom of the wall cabinet.
Listed by Underwriters Laboratories
Product Specification Revised 4/17
RANGE WITH 6 BURNERS, GRILL AND GRIDDLE
28-7/8"
Optional Backsplash
A
12" min. to combustibles or 0" to a non-combustible material above the cooking surface
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ZDP484NGPSS (NATURAL GAS)MONOGRAM 48" DUAL-FUEL PROFESSIONAL
ELECTRICAL REQUIREMENTS
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 50-amp circuit for 48" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range.
UNIVERSAL UTILITY LOCATIONS
8"
14" 16"
6-1/2"
Gas/
Electric
Electric
2"
2"
48"
Locate gas and electric as shown
GAS SUPPLY
• The natural gas models are designed to operate at
5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
• The LP models are designed to operate at 10" water
column pressure. For proper operation, the pressure of the LP gas supplied to the regulator must be between 11" and 13" water column.
6-1/2"
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non­combustible backsplash can be used.
ORDER ONE WITH A 48"-WIDE RANGE BACKSPLASH ZX12B48PSS–12" backsplash
ZXADJB48PSS– 30"-36" adjustable-height
backsplash with warming shelf
SIDE VIEW WITH A BACKSPLASH
to Front
Edge
3-3/16"
Control Panel
Depth
28-1/4" to
Beveled
Edge of Control
Panel Bullnose
27-1/2" to
Beveled Edge
- Maximum Adjacent
Cabinet
Depth for
Flush
Installation
28-1/4"
to Front of
Door
31-1/16"
to Front of
Handle
Countertop level
48-1/4"
with Oven Door
Open
7" Control Panel Height
ccessories
13/16"
30-36"
35-1/4"
to
36-3/4"
10-1/2"
12"
1"
0" clearance to a back or side wall below the cooking surface
Listed by Underwriters Laboratories
Product Specification Revised 4/17
Loading...
+ 1 hidden pages