Monogram ZDP48L6RWSS, ZDP48N6RWSS, ZDP48L6DWSS, ZDP36N6WSS, ZDP36N4RWSS Installation Instructions Manual

...
GE Monogram Installation Instructions
®
Professional Ranges
48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS
48" LP Gas Models ZDP48L4GWSS ZDP48L6RWSS ZDP48L6DWSS
36" Natural Gas Models ZDP36N6WSS ZDP36N4RWSS ZDP36N5DWSS
36" LP Gas Models ZDP36L6WSS ZDP36L4RWSS ZDP36L4DWSS
CAUTION
WARNING
Before you begin—Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Use and Care Book for future
reference.
This appliance must be properly grounded. See “Electric Supply”, page 7.
If you have questions concerning the installa­tion of this product, call the GE Answer Center® Consumer Information Service at
800.626.2000, 24 hours a day, 7 days a week. If you received a damaged range, you should
contact your dealer.
Installation of this range requires basic electrical, carpentry and mechanical skills. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the GE Appliance Warranty. See the back cover of the Use & Care Guide for warranty information.
Contents
CAUTION: THESE RANGES MUST BE INSTALLED IN CONJUNCTION WITH A SUITABLE OVER­HEAD VENT HOOD. Due to the high heat capacity of this unit, particular attention should be paid to the hood and duct work installation to assure it meets local building codes.
Check local building codes for the proper method of gas range installation. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the gas cooktop should be installed in accordance with the National Fuel Gas Code ANSI 223.1-1990 and National Electrical Code ANSI/NFPA 70-1990.
Standard installations:
48" Ranges require a 800 to 1200 CFM Hood. 36" Ranges require 600 to 800 CFM Hood. Hoods should be 24" min. deep and the same width as the cooktop.
CAUTION: These ranges weigh up to 600 pounds. Some disassembly will reduce the weight consider­ably. Due to the weight and size of the range and to reduce the risk of personal injury or
Island installations:
48" Ranges require a 800 to 1200 CFM Hood.
damage to the product, TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION. 36" Ranges require 600 to 1200 CFM Hood. Hoods should be 30" min. deep and 36" wide at the bottom. Note: When installing a range that includes a grill, select a blower on the high end of CFM recommendation.
Design Information
Models Available..................................................................................................................................3
Accessor y Requirements .....................................................................................................................3
Models Dimensions and Clearances...............................................................................................4,5
Advance Planning ...............................................................................................................................6
Installation Preparation
Tools & Materials Required ................................................................................................................7
Power Supply Locations......................................................................................................................7
Installation
Step 1: Remove Packaging..................................................................................................................8
Step 2: Level the range .......................................................................................................................9
Step 3: Connect Range to Gas............................................................................................................9
Step 4: Install the Range Backguard..................................................................................................9
Step 5: Connect Electrical ................................................................................................................10
Step 6: Slide Range Into Position ....................................................................................................10
Step 7: Replace Oven Doors.............................................................................................................10
Step 8: Assemble & Adjust Burners .................................................................................................11
Step 9: Adjustable Low Burner Settings ..........................................................................................11
Finalize Installation...........................................................................................................................11
2
Design Information
Professional Ranges
Models Available
These ranges are factory set for either natural gas or liquid propane gas. Order the model for your installation situation.
48" Natural Gas Models:
ZDP48N4GWSS 4 gas burners, grill and griddle
ZDP48N6RWSS 6 gas burners and grill
ZDP48N6DWSS 6 gas burners and griddle
48" Liquid Propane Gas Models:
ZDP48L4GWSS 4 gas burners, grill and griddle
ZDP48L6RWSS 6 gas burners and grill
ZDP48L6DWSS 6 gas burners and griddle
36" Natural Gas Models:
ZDP36N6WSS 6 gas burners
ZDP36N4RWSS 4 gas burners and grill
ZDP36N4DWSS 4 gas burners and griddle
36" Liquid Propane Gas Models:
ZDP36L6WSS 6 gas burners, grill and griddle
ZDP36L4RWSS 4 gas burners and grill
ZDP36L4DWSS 4 gas burners and griddle
Accessory Requirements
All models require the installation of a backguard. A backguard should be ordered at the same time as the range. Both must be on site at the time of installation.
Order one backguard for 48" Models:
ZX1B48WSS 1-1/2" high backguard (required for island installations)
ZX12B48WSS 12" high backguard
ZX22B48WSS 22" high backguard with warming rack (2 piece)
Order one backguard for 36" Models:
ZX1B36WSS 1-1/2" high backguard for island installations only
ZX12B36WSS 12" high backguard
ZX22B36WSS 22" high backguard with warming rack
22" High Backguard With Warming Shelf
12" High Backguard
1-1/2" Backguard for Island Installations only
3
Product
Design Information
Professional Ranges
Dimensions & Clearances
35-1/4"-36-3/4"
28-1/4"
Optional Backguards
36" Wide Range Models
21-1/4"
12"
1-1/2"
35-7/8"
35-1/4"-36-3/4"
28-1/4"
Optional Backguards
48" Wide Range Models
21-1/4"
12"
1-1/2"
47-7/8"
4