Monogram ZDP304NPSS Specifications

RANGE WITH 4 BURNERS
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE
A propane conversion kit is included with the range. High Altitude kit, WB28K10553 for operation above 6,000 feet, is also available. The kits must be installed by a qualified service technician at additional cost.
INSTALLATION INFORMATION
Before installing, consult installation instructions packed with product or online at Monogram.com for current dimensional data. A 30" or 36" wide professional vent hood with a minimum 300 CFM is recommended for installation over this range. Install the hood 30" to 36" above the cooking surface.
35 1/4"
to
36 3/4"
height
28 1/4"
Depth to front of door
ZDP304NPSS (NATURAL GAS)MONOGRAM 30" DUAL-FUEL PROFESSIONAL
29 7/8" width
3 1/4" to 4 3/4"
Toekick/leg
height
ADVANCE PLANNING
Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom.
• Clearance between range and side wall or combustible material must be at least 12" on each side.
• Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1-990.
WARNING
Installations without a hood require 48" minimum to combustibles. A custom hood installation with exposed horizontal combustible surfaces must have an Auto-On feature. Refer to hood installation instructions for specific hood clearances.
The surface of the entire back wall above the range and below the hood must be covered with a non­combustible material such as metal, ceramic tile, brick, marble or other stone.
13" max.
18" min.
12" minimum to adjacent wall
48" minimum to combustibles
Non-Combustible
Material
12" minimum
each side
30" min.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall on each side.
Working areas adjacent to the rangetop should have 18" minimum clearance between countertop and the bottom of the wall cabinet.
Listed by Underwriters Laboratories
Product Specification Revised 10/18
RANGE WITH 4 BURNERS
Open
ZDP304NPSS (NATURAL GAS)MONOGRAM 30" DUAL-FUEL PROFESSIONAL
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL REQUIREMENTS
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 30-amp circuit for 30" ranges.
The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range.
UNIVERSAL UTILITY LOCATIONS
4-5/8"
9-3/8"11-3/8"
3"
G/E
E
6-1/2"
2"
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. A custom, non-combustible backsplash can be used.
SIDE VIEW WITH A BACKSPLASH
28-7/8"
to Front
Edge
3-3/16"
Control Panel
Depth
28-1/4" to
Beveled
Edge of Control
Panel Bullnose
27-1/2" to
Beveled Edge
- Maximum Adjacent
Cabinet
Depth for
Flush
Installation
Countertop level
7" Control Panel Height
Optional Backsplash Accessories
13/16"
30-36"
35-1/4"
to
36-3/4"
10-1/2"
12"
1"
30"
Locate gas and electric as shown
GAS SUPPLY
• The natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
• The LP models are designed to operate at 10" water column pressure. For proper operation, the pressure of the LP gas supplied to the regulator must be between 11" and 13" water column.
28-1/4"
to Front of
Door
12" min. to combustibles or 0" to a non-combustible material above the cooking surface
0" clearance to a back or side wall below the cooking surface
31-1/16"
to Front of
Handle
48-1/4"
with Oven Door