OVERALL DIMENSIONS
23 1/2" (59.7)
FRONT VIEW
23 9/16" (58.6)
21 9/16" (53.5)
ZDBI240HIIGE Monogram® Beverage Center
34 1/4"
(87)
SPECIFICATIONS
Overall Width 23 1/2" (59.7 cm)
Overall Height 34 1/4" (87 cm)
Overall Depth 23 9/16" (58.6 cm)
Door Clearance 9 3/8" (23.8 cm) @ 110°
5/8" (1.6 cm) @ 90°
23 5/8" (58.6) door length
Overall Capacity 5.5 cu. ft.
Minimum Cabinet Width 23 3/4" (60.3 cm)
Minimum Cabinet Depth 24" (60.9 cm)
Cutout Width 23 3/4" (60.3 cm)
Cutout Height 34 1/2" (87.7 cm) Min
35" (89 cm) Max
Electrical Requirements 1.2 A
Voltz/Hertz/Amps 120 V, 60 Hz,
15 or 20 amp circuit
Shipping Weight 146 lb (66 kg)
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply
is required. An inidividual properly grounded
branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall.
Dimensions in parentheses
are in centimeters unless
otherwise noted.
Actual product dimension
may vary due to
manufacturing tolerances.
SIDE VIEW
23 1/2" (59.7)
TOP VIEW
(SHOWING
DOOR SWING)
4 1/2"
(11.4)
5/8"
(1.6)
23 5/8"
(58.6)
Product Specification Created 7/14
GE Monogram® Beverage Center
ZDBI240HII
INSTALLATION
34 1/2"
(87.7)
Min
underside of
counter to floor
35" (89) Max
FLUSH CUTOUT INSTALLATION
2 1/4" (5.7)
wide
all sides
Route the
back side
of the
opening
7/16" (1.1) deep,
1 1/8" (2.9) wide
2 1/4"
(5.7)
(60.1)
24"
min cutout depth
SIDE VIEW
23 1/8"
25 1/4"
(64.1)
GLASS
18 5/8"
(47.3)
2 1/4"
(5.7)
CUSTOM PANEL
OPTION 1
(58.7)
29 3/4"
(75.6)
2 1/4"
(5.7)
9" (22.9)
INSTALLATION CUTOUT
2 1/4" (5.7)
wide
all sides
Route the
back side
of the
opening
7/16" (1.1) deep,
1 1/8" (2.9) wide
2 1/2"
(5.1)
1/4"
1/8"
(0.6)
(0.3)
23 3/4" (60.3) Min
cutout width
10 1/2" (26.7)
Max
ELECTRIC
1 1/2" (3.8)
FRONT VIEW
23 1/8"
25 1/4"
GLASS
18 5/8"
2 1/4"
(5.7)
Cut the notch
1/8" (0.3) deep, 1/4" (0.6)
1/4"
wide and 1/4" (0.6)
(0.6)
high
CUSTOM PANEL
OPTION 2
(58.7)
2 1/4"
(5.7)
30"
(76.2)
NOTES
Installation Space
The Monogram® Beverage
Center may be installed
beneath a countertop or can
be used free-standing.
• If installing between
frameless cabinets, a
1/2"-wide ller strip or side
panel may be required.
The ller strip will act as
a spacer between the
door case and adjacent
cabinet and will prevent
interference with cabinet
door swing. The width of
the opening must include
ller panels.
Note: When installed, the
door should project
forward 1" of adjacent
24"-deep cabinets.
Location Requirements
All Monogram Refrigeration
Modules may be closed in
on the top and sides as long
as the front is unobstructed
for air circulation and door
swing.
• Do not install these
products where the
temperatures will go below
55°F (13°C) or above 90°F
(32°C).
• Do not install where they
will be subject to direct
sunlight, heat or moisture.
• These products are not
designed to be stacked one
over the other.
Side-by-Side Installation
For a complete refreshment
center, install a Monogram
Wine Reserve and Beverage
Center together.
• Products must operate
from separate properly
grounded receptacles.
Door Swing Clearances
All Monogram Refrigeration
Modules are factory set for a
110° door swing.
When installed in a corner:
• Allow the minimum door
swing clearances shown.
• The minimum clearance
shown at 90° will allow full
extension of drawers and
shelves.
Product Specification Created 7/14