Monessen Hearth VFC24C, VFC32C, VFC24L, VFC32L User Manual

VFC Vent Free Fireplace System Installation & Operating Instructions
Models: VFC24C, VFC24L, VFC32C & VFC32L
WARNING: If the information in this
manual is not followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS – Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building. – Leave the building immediately. – Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the re department.
Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and venti­lation air must be provided. Refer to Page 8.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
CONTENTS
VFC Vent Free Fireplace System
Thank you and congratulations on your purchase of a Monessen Fireplace.
PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS
BEFORE USING THE APPLIANCE.
IMPORTANT: Read all instructions and warnings carefully before starting installation.
Failure to follow these instructions may result in a possible re hazard and will void the warranty.
Important Safety Information ...................................... 3
Codes ....................................................................... 4
Product Features .......................................................... 5
Operation ................................................................. 5
Gas Pressures ......................................................... 5
Gas Specications and Orice Sizes ....................... 5
Ignition Controls ....................................................... 5
Pilot .......................................................................... 5
Thermal Generator ................................................... 5
Cold Climate Option ................................................. 6
Fireplace And Framing Dimensions .......................... 7
Pre-Installation Information ......................................... 8
Getting Started ......................................................... 8
What You Will Need For Installation ......................... 8
Adequate Combustion and Ventilation Air ................ 8
Fireplace Installation .................................................... 9
Fireplace Location .................................................... 9
Clearances ............................................................. 10
Framing and Anchoring ...........................................11
Securing Heater to Floor or Hearth .........................11
Gas Line And Pressure .............................................. 12
Connecting the Gas Line ....................................... 12
Checking Gas Pressure – Millivolt .......................... 12
Check Gas Pressure – IPI ...................................... 13
Final Installation ......................................................... 13
Remove Screen ..................................................... 13
Install Canopy ........................................................ 13
Electrical Wiring – Millivolt ......................................... 14
Connect Optional Wall Switch or Thermostat ........ 14
Connect Remote Receiver ..................................... 15
Check System Operation ....................................... 15
Operating Instructions – Millivolt .............................. 16
For Your Safety Read Before Lighting ................... 16
What to do if You Smell Gas .................................. 16
Lighting Pilot For the First Time ............................. 16
Lighting Pilot .......................................................... 17
Lighting Burner ....................................................... 18
To Turn Off Gas ...................................................... 18
Electrical Installation – Ipi .......................................... 19
Electrical Wiring ..................................................... 19
Junction Box Wiring ............................................... 19
Wall Switch Installation .......................................... 20
IPI System Wiring Diagram .................................... 20
Operating Instructions – Ipi ........................................ 21
Operations and Indications .................................... 21
For Your Safety Read Before Lighting ................... 22
What to do if You Smell Gas .................................. 22
Operating Instructions ............................................ 22
To Turn Off Gas to Appliance ................................. 22
Electrical Wiring – Fan ................................................ 23
Log And Media Placement ......................................... 24
Cast Iron Grate Installation .................................... 24
Rock Wool Placement ............................................ 24
Log Placement (VFC24L/VFC32L Only) ................ 25
Glass Only Placement ........................................... 26
Flame Appearance ...................................................... 27
Pilot and Burner Flame Appearance ...................... 27
Checking the Pilot Flame ....................................... 27
Checking Burner Flame ......................................... 28
Operating Instructions ............................................ 28
Operating Instructions ............................................... 29
For Your Safety Read Before Lighting ................... 29
What to do if You Smell Gas .................................. 29
Millivolt/Thermostat Control Lighting Instructions .. 30
To Turn Off Gas to Heater ...................................... 30
Match Lighting Instructions .................................... 31
Blower Operation ................................................... 31
Cleaning And Servicing ............................................. 32
Annual Cleaning/Inspection ................................... 32
Periodic Cleaning ................................................... 32
Optional Accessories ................................................. 33
Forced Air Kit ......................................................... 33
Installing Optional Firebrick Panels ........................ 33
Installing Optional Porcelain Panels ...................... 34
Installing Optional Black Magic Panels .................. 34
Troubleshooting ......................................................... 35
Replacement Parts ..................................................... 38
VFC Firebox Parts ................................................. 38
VFC24 Millivolt Burner Parts .................................. 39
VFC24 IPI Burner Parts ......................................... 40
VFC32 Millivolt Burner Parts .................................. 41
VFC32 IPI Burner Parts ......................................... 42
Replacement Logs ................................................. 43
Warranty ...................................................................... 44
2
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
IMPORTANT SAFETY INFORMATION
INSTALLER
Please leave these instructions with the appliance.
OWNER
Please retain these instructions for future reference
.
WARNING:
• Any change to this heater or its controls can be dangerous.
• Improper installation or use of the heater can cause serious injury or death from re, burns, explosion or carbon monoxide poisoning.
• Do not allow fans to blow directly into the replace. Avoid any drafts that alter burner ame
patterns.
• Do not use a blower insert, heat exchanger insert or other accessory, not approved for use with this heater where applicable.
1. Due to high temperatures, the appliance should be
located out of trafc and away from furniture and draperies.
2. Children and adults should be alerted to the hazard
of high surface temperature and should stay away to avoid burns or clothing ignition.
3. Young children should be carefully supervised when
they are in the same room with the appliance.
4. Do not place clothing or other ammable material
on or near the appliance.
5. Any safety screen or guard removed for servicing
an appliance, must be replaced prior to operating the heater.
6. Installation and repair should be done by a qualied
service person.
7. To prevent malfunction and/or sooting, an unvented
gas heater should be cleaned before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.
8. CARBON MONOXIDE POISONING: Early signs of
carbon monoxide poisoning are similar to the u with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly.
9. The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.l/NFPA54.
10. This unit complies with the latest edition of ANSI Z21.11.2–2013, Unvented Heaters.
11. Do not install the heaters in a bathroom or bedroom.
12. Correct installation of the refractory cement logs, proper location of the heater, and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or opera­tion, can settle on surfaces outside the replace. See log placement instructions for proper installation.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
13. Avoid any drafts that alter burner ame patterns. Do not allow fans to blow directly into replace. Do not place a blower inside burn area of rebox. Ceiling fans may create drafts that alter burner ame patterns. Sooting and improper burning will occur.
14. CAUTION: Candles, incense, oil lamps, etc. produce combustion byproducts including soot. Vent-free appliances will not lter or clean soot produced by these types of products. In addition, the smoke and/ or aromatics (scents) may be reburned in the vent-free appliance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appliance is in operation.
15. This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi­sions for adequate combustion and ventilation air must be provided.
16. This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code or applicable local codes.
17. Keep room area clear and free from combustible mate­rials, gasoline and other ammable vapors and liquids.
18. Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appli­ance.
19. Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.
20. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, lms or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
3
IMPORTANT SAFETY INFORMATION
VFC Vent Free Fireplace System
The initial break-in operation should last six hours with
the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.
21. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code.
22. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
23. Do not use this room heater if any part has been under water. Immediately call a qualied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
24. Never burn solid fuels in a replace where a unvented room heater is installed.
25. Always have a replace screen in place when the appliance is in operation and, unless other provisions for combustion air are provided, the screen must have an opening(s) for induction of combustion air.
THIS APPLIANCE MAY BE INSTALLED IN AN AFTER-MARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS APPLIANCE IS NOT CONVERT­IBLE FOR USE WITH OTHER GASES.
WARNING: Never connect unit to private (non-utility) gas wells. This gas
is commonly known as wellhead gas.
CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
4
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
1430 Broadway
New York, NY 10018
or
Batterymarch Park
Quincy, MA 02269
VFC Vent Free Fireplace System
PRODUCT FEATURES
GAS SPECIFICATIONS AND ORIFICE SIZES
Fireplace Screen
On/Off Switch
Piezo Ignition
Control Knobs
Figure 1. VFC Shown with Control Access Door Open
OPERATION
This unvented gas heater requires no outside venting and burns cleanly with excellent heating efciency. As a zero-clearance appliance, it can be installed against (or recessed into) any wall that is accessible to a gas line.
GAS PRESSURES
Control Fuel Millivolt and IPI
Regulator Pressure Nat. 3.5" w.c.
Pilot Regulator Nat. 3.5" w.c.
Max. Inlet Pressure Nat. 10.5" w.c.
Min. Inlet Pressure Nat. 5.0" w.c.
Regulator Pressure LP 10.0" w.c.
Max. Inlet Pressure LP 13.0" w.c.
Min. Inlet Pressure LP 11.0" w.c.
MAX
MODEL FUEL CONTROL
VFC24CNV NAT MILLIVOLT 22,000 16,000 2.35mm
VFC24CPV LP MILLIVOLT 22,000 20,000 1.45mm
VFC24CNI N AT IPI 22,000 16,000 2.35mm
VFC24CPI LP IPI 22,000 20,000 1.45mm
VFC24LNV NAT MILLIVOLT 22,000 16,000 2.35mm
VFC24LPV LP MILLIVOLT 22,000 20,000 1.45mm
VFC24LNI N AT IPI 22,000 16,000 2.35mm
VFC24LPI LP IPI 22,000 20,000 1.45mm
VFC32CNV NAT MILLIVOLT 28,000 19,000 #38
VFC32CPV LP MILLIVOLT 27,000 22,000 #52
VFC32CNI N AT IPI 28,000 19,000 #38
VFC32CPI LP IPI 27,000 22,000 #52
VFC32LNV NAT MILLIVOLT 28,000 19,000 #38
VFC32LPV LP MILLIVOLT 27,000 22,000 #52
VFC32LNI N AT IPI 28,000 19,000 #38
VFC32LPI LP IPI 27,000 22,000 #52
BTU
MIN
BTU
ORIFICE
SIZE
NOTE: For LP models an external regulator is required to reduce supply pressure to a maximum of 13" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Millivolt and EcoLogic® 2.0 controls have four (4)
positions:
OFF - All gas to the gas logs is shut off at the valve. IGN - Valve position to light/maintain a standing pilot. ON - Valve position to turn ON/OFF log set with remote switch/thermostat. LOW/HI - Variable position to control ame height (heat output).
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
PILOT
The gas log heater is tted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be re-lit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is tted with a millivolt generator to provide power for remote activation.
5
PRODUCT FEATURES
VFC Vent Free Fireplace System
COLD CLIMATE OPTION (IPI Models Only)
NOTE: If you live in a cold climate, seal all cracks around your appliance and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the oor on which the appliance rests, if the oor is above ground level. Your replace is equipped with an intermittent pilot ignition (IPI) control. An IPI control with a standing pilot option pro­vides the dual benet of an economical and environmentally responsible product and one which lights easily even in the coldest climates. When in intermittent pilot mode (as it comes from the factory), your pilot remains unlit until needed, saving you fuel. Standing pilot mode, by com­parison, is characterized by a continuously burning pilot. The benet of a pilot which lights only when needed is fuel savings. However, with no pilot burning in your replace, units operating in colder climates may experience delayed start up or lock out. Because colder air is heavier than milder air and there is no pilot burning to maintain a warm stable temperature in your rebox, establishing a draft to aid ignition becomes difcult. This is perfectly normal but can be somewhat frustrating.
To remedy this issue, your replace has been designed with a cold climate pilot option, which, when active, maintains a warmer temperature inside your rebox to make ignition faster and more efcient. Operating your appliance in cold climate (aka standing) pilot mode will prohibit the need for multiple ignition attempts and will prevent the system from delaying start up or locking out.
To activate the cold climate option, simply move the cold climate toggle switch located on the right side of the black control center to the “On” (left) position. (Figure 2) You can operate your appliance in this mode regardless of whether you are using a remote control, wall switch or thermostat.
Figure 2. Cold Climate Option
6
Cold Climate Switch
Master Switch
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
FIREPLACE AND FRAMING DIMENSIONS
S
R
S
Q
Figure 3. Fireplace and Framing Dimensions
1/2” or 5/8”
Min. Rough Opening Height
D
L
M
O - Min. Rough Opening Width
N
I
B
A
G
E
F
Min. Rough Opening Depth
P
H
C
J
K
Ref. VFC24 VFC32
A 24
B 22
C 26
D 19" (482 mm) 25
E 16
F 4
G 4
H 14
I 1" (25 mm) 1
J 13
K 11
L 16" (406 mm) 17
M 22
5
8" (625 mm) 32" (813 mm)
5
8" (575 mm) 283⁄4" (730 mm)
1
2" (673 mm) 30" (762 mm)
3
4" (654 mm)
1
4" (413 mm) 191⁄2" (495 mm)
1
2" (114 mm) 53⁄4" (146 mm)
7
8" (124 mm) 5" (127 mm)
1
2" (368 mm) 141⁄2" (368 mm)
5
8" (41 mm)
1
8" (333 mm) 131⁄8" (333 mm)
3
8" (289 mm) 113⁄8" (289 mm)
1
2" (445 mm)
3
4" (578 mm) 283⁄4" (730 mm)
Framing Dimensions
N 26
O 25
P 13
Q 44
R 24" (610 mm) 29
S 32
3
4" (680 mm) 301⁄4" (768 mm)
1
8" (638 mm) 321⁄2" (826 mm)
3
8" (340 mm) 133⁄8" (340 mm)
7
8" (1140 mm) 58" (1478 mm)
1
4" (743 mm)
1
2" (826 mm) 41" (1041 mm)
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
7
PRE-INSTALLATION INFORMATION
VFC Vent Free Fireplace System
WARNING:
Gloves are recommended when handling
refractory cement logs to prevent skin
irritation from loose bers. Logs are fragile — handle with care.
GETTING STARTED
Make sure you have received all parts:
Check your packing list to verify that all listed parts have been received. You should have the following:
Unvented gas heater
Installation/operating instruction
Four (4) black screws
Canopy and three (3) screws
Two (2) anchoring screws
Refractory cement logs or glass media
Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
WARNING—Do not install the heater:
Where curtains, furniture, clothing, or
other ammable objects are less than
42" from the front of the heater.
In high trafc areas.
In windy or drafty areas.
NOTE: Be sure all packing material has been removed
from underside the unit.
2. Install canopy and logs per instructions found in this manual. The canopy MUST be installed for safe oper­ation of the unit.
3. Field wire main power supply to units with fan kit. Refer to the Electrical Section found in this manual. (Electrical connections should only be performed by an experi­enced, licensed certied tradesman).
4. Install optional ON/OFF kit on units with millivolt control. Refer to the installation instructions included with the kit and also refer to the Electrical Wiring section found in this manual.
5. Plumb gas line. Refer to the Connecting the Gas sec-
tion found in this
manual. (Gas connections should only be performed by an experienced, licensed/certied tradesman).
6. Complete nish wall material and/or surround.
WHAT YOU WILL NEED FOR INSTALLATION:
You must have the following items available before pro­ceeding with installation:
External regulator (for propane/LPG only)
Manual shutoff valve
Piping which complies with local codes
Sediment trap
Phillips head screwdriver
Tee joint
Pipe sealant approved for use with propane/LPG
Pipe wrench (resistant to sulfur compounds)
When planning the installation for the replace it is nec­essary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned. The following steps repre­sent the normal sequence of installation. Each installation is unique, however, and might require a different sequence.
1. Position fireplace in desired location. Refer to the
Location of Fireplace and Clearances and Height Requirements, and Firebox Framing sections found in
this manual.
ADEQUATE COMBUSTION AND VENTILA­TION AIR
This heater shall not be installed in a conned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA54), denes a conned space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space, and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of a conned space.
WARNING: If the area in which the heater
is operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code or applicable local codes.
8
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
FIREPLACE INSTALLATION
Unusually tight construction is dened as construction where:
a. walls and ceilings exposed to the outside atmosphere
have a continuous water vapor retarder with a rating of 1 perm (6 x 10 gasketed or sealed, and
b. weather stripping has been added on openable windows
and doors, and
c. caulking or sealants are applied to areas such as joints
around window and door frames, between sole plates and oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and other openings.
The following formula can be used to determine the maxi­mum heater rating per the denition of unconned space:
BTU/Hr = (L1 + L2) Ft x (W) Ft x (H) Ft
Consider two connecting rooms with an open area between, with the following dimensions:
L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft.
If there were a door between the two rooms the calculation would be based only on the room with the heater.
11
kg per pa/sec-m2) or less with openings
50
BTU/Hr = (151/2 + 12) x (12) x (8)
50
BTU/Hr = (151/2) x (12) x (8)
50
FIREPLACE LOCATION
Carefully select the best location for installation of your unvented replace. The following factors should be taken into consideration.
Clearance to side wall, ceiling, woodwork and
window or other combustibles. Refer to “Clearances” section. Minimum clearances to combustibles must
be maintained.
Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers for forced air furnaces / air conditioners, windows or doors.
Installation must provide adequate ventilation and
combustion air.
DO NOT INSTALL THESE MODELS IN A BED-
ROOM OR BATHROOM.
Location should be out of high trafc areas and
away from furniture and draperies due to heat from rebox.
Never obstruct the front opening of the unvented
replace or restrict the ow of combustion and ven­tilation air.
Minimize modications to existing construction. Refer
to Figure 5 below for location suggestions.
Do not install in the vicinity where gasoline or other
ammable liquids may be stored. The unvented re­box must be kept clear and free from the combustible materials.
Figure 4. Combustion Air Calculation
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Counter
Fireplace
H
W
Figure 5. Possible Fireplace Loca- tions
9
FIREPLACE INSTALLATION
VFC Vent Free Fireplace System
CLEARANCES
Ensure that minimum clearances shown in Figure 6 and Figure 7 are maintained. Left and right clearances are determined when facing the front of the rebox.
Follow these instructions carefully to ensure safe instal­lation. Failure to follow these requirements may create a re hazard.
Sidewall Clearances — The clearance from the inside of the appliance to any combustible adjacent wall should not be less than 9" for the VFC24 and VFC32. Figure 6
Ceiling Clearance — The ceiling must be at least 42" from the top of the rebox opening. Figure 6
Back Wall Clearance — The appliance may be placed against a combustible back wall.
Floor Clearance — The replace may be installed directly on a combustible oor or a raised platform of an appropri­ate height. Do not place replace on carpeting, vinyl, tile or other soft oor coverings. It may, however, be placed on at wood, plywood, particle board or other hard surfaces. Be sure replace rests on a solid continuous oor or platform with appropriate framing for support and so that no cold air can enter from under the rebox.
Mantel clearances — The canopy supplied with the unit must be installed. If a combustible mantel is installed. It must meet the clearance requirements detailed in Figure 7
NOTE: The Monessen Barrington cabinet model series BWC300, BWC400 and BWC500 are specially designed to comply with all mantel temperature requirements. Any custom-built mantel must comply with all clearance require­ments shown in this instruction manual.
12”
19”
2¹⁄₂
10”
Canopy
FP2508
Figure 7. Mantel Clearances
WARNING: The dimensions shown
in Figures 6, 7 and 8 are minimum
clearances to maintain in installing this heater.
Left and right clearances are determined when
facing the front of the heater. Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a re hazard.
42" Minimum
9"
Minimum
Figure 6. Sidewall and Ceiling Clearances
10
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Minimum
9"
Figure 8. Mantel Leg Clear­ances
1”
2¹⁄₂
3”
5”
6”
1¹⁄₂
7¹⁄₂
9”
3¹⁄₂
Finish Wall
4¹⁄₂
6”
Combustible
Material Area
7¹⁄₂
45°
VFC Vent Free Fireplace System
FIREPLACE INSTALLATION
FRAMING AND ANCHORING
If unit is to be “built in”, replace framing can be built before or after the appliance is set in place. BE SURE THAT ALL
PACKING MATERIAL HAS BEEN REMOVED FROM THE UNDERSIDE OF THE UNIT PRIOR TO SETTING THE FIREBOX IN PLACE. Construct replace framing following
Fireplace and Framing Dimensions. The framing headers may rest directly on top of the rebox.
The replace may be installed directly on a combustible oor or a raised platform of an appropriate height. Do not place replace on carpeting, vinyl, tile or other soft oor coverings. It may, however, be placed on at wood, plywood, particle board or other hard surfaces. Be sure replace rests on a solid continuous oor or platform with appropriate framing for support and so that no cold air can enter from under the rebox.
Anchor replace to the side framing members using nailing anges.
1. Bend out the nailing anges located on each side of the rebox.
2. Slide the rebox into prepared framing or position rebox in its nal position and frame later.
3. Level the rebox by checking the top edge of the rebox. Shim if necessary.
4. Anchor rebox to the side framing members using 8d nails or other suitable fasteners. Figure 9
5. The canopy must be installed for safe operation of the heater. Refer to canopy installation details.
SECURING HEATER TO FLOOR OR HEARTH
NOTE: Clearance requirements as detailed in the Clearances section on of this manual, must be met before securing the heater in place.
To prevent movement, the heater must be secured to the oor or hearth.
1. Open the control access door and remove the screen.
2.
Secure the rebox with two anchoring screws (3⁄16 length) supplied with the replace system. Figure 10
NOTE: If the unit is mounted on carpeting, tile or combustible material without the hearth, a metal or wooden base covering the entire width and depth of the base must be installed.
" x 11⁄4
"
WARNING: The replace must be installed giving full consideration to the clearance
and height requirements identified in this
manual.
Nail Sides Through Nailing Flanges
Figure 9. Nailing Flanges
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Anchor Screws
3
16" x 11⁄4"
Figure 10. Secure Fireplace to Floor or Hearth
11
GAS LINE & PRESSURE
VFC Vent Free Fireplace System
CONNECTING THE GAS LINE
NOTICE: A qualied gas appliance installer must connect
the heater to the gas supply. Consult all local codes.
WARNING: Use new black iron or steel pipe. Internally tinned copper or
copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulde limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (Listed on Data Plate) at the maximum ow rate (BTU/hr). Undue
pressure loss will occur if the pipe is too small.
A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 11
To Fireplace
Pipe Coupling
Pipe
Stainless Flexible Tube
Manual Shutoff Valve
Figure 11. Gas Connection
IMPORTANT: Loosen the pipe adapter on the ex tube before installing to the system piping.
Always use an external regulator for all propane/LPG heat­ers only, to reduce the supply tank pressure to a maximum of 13" w.c. This is in addition to the internal regulator in the heater valve.
To reach factory installed ex line, go through access door on right or left side of rebox.
WARNING: CHECK GAS TYPE: The
gas supply must be the same as stated
on the heater’s rating plate. If the gas
supply is different, DO NOT INSTALL THE HEATER. Contact your dealer for the correct model. Connecting to the wrong gas type may result in property damage or personal injury.
Locations Pressure Tapping Point Instal­lation
Gas Supply Inlet
WARNING: Connecting directly to an unregulated propane/LPG tank can cause an explosion
Access Door for Gas Line
Manual Gas Shutoff
Stainless Flex Line
Figure 12. Access Holes
(Recommended Outlet Positioned Vertical)
The stainless ex line is on the right side facing the re­place and can connect to either a 3/8 NPT female or 1/2 NPT male pipe. To connect from the opposite side, route the pipe under the rear portion of the unit.
Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solution after completing connection. DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to HIGH.
Open control access door on either side of unit to nd valve and regulator referred to below. Figure 12
CHECKING GAS PRESSURE – MILLIVOLT CONTROL
Figure 12
The valve regulator controls the burner pressure which should be checked at the pressure test point.
Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point (Use test point “OUT” closest to con­trol knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.
Figure 13. Pressure Test Point Location Millivolt Control
Test Port
"OUT"
12
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
FINAL INSTALLATION
CHECK GAS PRESSURE – IPI
1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the replace, STOP! Do not install the appliance. Contact your dealer immediately.
2. To facilitate easier installation, a 18" (610 mm) ex line with manual shut-off valve has been provided with this appliance. Install and attach 1/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the replace for leaks. Use a solution of 50/50 water and soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Fig­ure 14 After taking pressure reading, be sure and turn captured screw clockwise rmly to reseal. Do not over torque. Check test points for gas leaks.
WARNING: Do NOT use open ame to check for gas leaks.
REMOVE SCREEN
NOTE: Fireplace screen must be removed to access log
box and to install canopy.
Figure 14
1. Remove bottom access panel.
2. Removing replace screen frame panel by pushing
screen frame panel up and out.
Canopy
Fireplace Screen
Figure 14. IPI Valve
Pressure Inlet
Pressure Outlet
FP3034
Pilot Adjust­ment Screw
Figure 15. Remove Fireplace Screen Panel
INSTALL CANOPY
Figure 15
1. Align the black canopy with the holes in the top frame assembly.
2. Install the three (3) screws (in owner’s manual packag­ing) which attach the canopy to the top frame assembly.
3. Tighten all screws. Make sure the canopy is level and secure.
Canopy
WARNING: Do not operate the unit with-
out the screen frame panel and canopy installed.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Screws
Figure 16. Install Canopy
13
ELECTRICAL WIRING — MILLIVOLT
VFC Vent Free Fireplace System
ODS Pilot
On/Off Switch
Field Installed Optional Wall Switch or Remote Receiver
Figure 17. Wiring Diagram
On/Off Switch
TH = 3
TP = 1
TP/TH = 2
Switch
ODS Pilot
Valve
Spade Terminal
FP2112a
WARNING: Label all wires prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation
after servicing.
The millivolt valve is a self-powered combination gas con­trol THAT DOES NOT REQUIRE 110V AC TO OPERATE.
Refer to Figure 17 and installation instructions provided with optional wall switch, thermostat or remote control for wiring instructions. A maximum length of 15 feet of 18awg two conductor wire is to be used for wall switch or ther­mostat installations.
NOTE: Thermostats and switches must be suitable for millivolt operation.
14
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
WARNING: Do NOT connect wall switch to 110 V circuit.
CONNECT OPTIONAL WALL SWITCH OR THERMOSTAT
1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of the unit. The color of the wires does not matter.
VFC Vent Free Fireplace System
CONNECT REMOTE RECEIVER
THESE INSTRUCTIONS SUPERCEDE THE SECTION ENTITLED “HEARTH MOUNT” IN THE MILLIVOLT HAND-HELD REMOTE INSTRUCTIONS SUPPLIED WITH THE REMOTE.
Figure 17
1. Remove bottom control door.
2. Connect the remote connector wires located in the unit to the remote receiver.
3. Stick Velcro® pads with self-adhesive backing to bottom of remote receiver and to oor of compartment behind access panel.
®
4. Attach remote receiver to rebox with Velcro
pads.
Control switch must face forward.
NOTE: Do not place remote in combustion chamber,
only the remote receiver.
CHECK SYSTEM OPERATION
The millivolt system and individual components may be checked with a millivolt meter having a 0-1000 mV range. Conduct each check shown in chart below by connection meter test leads to terminals as indicated.
ELECTRICAL WIRING — MILLIVOLT
Remote Receiver
Figure 18. Install Remote Receiver
A. COMPLETE MILLIVOLT SYSTEM CHECK
(“A” Reading: Thermostat contacts CLOSED,
control knob “ON,” main burner should turn ON)
a. If the reading is more than 100 millivolts and the
automatic valve still does not come on, replace the control.
b. If the closed circuit reading (“A” reading) is less than
100 millivolts, determine cause for low reading, pro­ceed to Section B below.
Connect Meter
Check
Test
A
B
To
Test
Complete
System
Thermopile
Output
Leads to
Terminals
B. Thermopile Output Reading Check
(“B” Reading: Thermostat contacts OPEN, main burner OFF)
1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 325 millivolts minimum. If the minimum millivolt reading is not obtainable, replace pilot.
Switch or
Thermostat
Contacts
Meter Reading
Should Be
2 & 3 Closed Closed
1 & 2 Open Open
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
15
OPERATING INSTRUCTIONS—MILLIVOLT
VFC Vent Free Fireplace System
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instruction exactly, a re or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these
instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the oor
because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
Turn off all gas to the appliance.
Open windows.
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re department.
C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push
in or turn by hand, don't try to repair it. Call a qualied service technician. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualied service
technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
LIGHTING PILOT FOR THE FIRST TIME
INITIAL LIGHTING
Purge air from the supply line as follows:
Open main shutoff valve.
Unscrew main pressure test point.
Leave inlet test screw open until gas comes in.
When gas is owing, tighten inlet screw immediately.
LEAK TESTING
1. Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture.
2. Next check for gas leaks at the burner with soap and water mixture.
3. Check the pilot for gas leaks with soap and water mixture.
16
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
WARNING: NEVER use open ame to check for gas leaks.
VFC Vent Free Fireplace System
PILOT
OPERATING INSTRUCTIONS—MILLIVOLT
LIGHTING PILOT FOR THE FIRST TIME
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
WARNING: NEVER use open ame to check for gas leaks.
WARNING: If using a soap and water
solution to test for leaks, DO NOT
spray solution onto control body.
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body
LIGHTING PILOT
WARNING: The control has an interlock device that does not allow the lighting of the
replace up to the moment the safety device of the ame has not interrupted the gas ow. After that period of time (when the magnet is closed), it is possible to start the
lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise
2. Depress fully and hold pilot gas knob. Depress piezo igniter as many times as needed to ignite pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
Pilot Position
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
to pilot position.
O
N
T
O
L
I
P
F
F
O
Continued on next page
17
PILOT
PILOT
OPERATING INSTRUCTIONS – MILLIVOLT
LIGHTING BURNER
LIGHTING THE BURNER
Depress and turn the knob counterclockwise to the “ON” position. It will take less than four (4) seconds for the burner to ignite.
MAIN BURNER SWITCH
This switch allows you to turn on and to turn off the main burner without using the gas valve knob. is in the “ON” position to light the main burner.
O
N
T
O
L
I
P
F
F
O
VFC Vent Free Fireplace System
Wall Switch
N
O
O
F
F
P
I
L
T
O
Pilot Position
Depress and turn knob clockwise
Off Position
On Position
TO TURN OFF GAS
to “OFF” position.
I
L
P
O
T
F
F
O
O
N
PILOT
18
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
ELECTRICAL INSTALLATION — IPI
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
WARNING: Electrical connections should only be performed by a qualied, licensed electrician. Main power must be off
when connecting to main electrical power supply or performing service. All wiring shall
be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code,
CSA C22.1.
ELECTRICAL WIRING
General
1. This replace is equipped with an IPI control valve which operates on 6 volts. The 6 volt DC adapter plugs into the replace junction box A/C power supply.
2. The IPI system can also be operated without A/C power. The system can run on four (4) “AA” batteries using the optional battery backup for approximately six (6) months under normal use.
Optional Accessories
This replace may be used with a wall switch, wall mounted thermostat or IPI hand held remote control.
WARNING: Do NOT connect to a 110V circuit.
JUNCTION BOX WIRING
1. This should be done before framing the replace. Wire the receptacle into an electrical circuit. Wire with mini­mum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing the screw from the side of the outside rebox wall. Junction box was installed at the factory.
3. The junction box cover has a factory installed “romex” style strain relief connector. After connecting the wires, route the wire leads through this connector. Refer to the wiring diagram in Figure 19
120V AC
60Hz
Factory Supplied Not Supplied
Junction Box
Figure 19. Junction Box Wiring Diagram
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
19
ELECTRICAL INSTALLATION – IPI
VFC Vent Free Fireplace System
WALL SWITCH INSTALLATION
The wall switch wire connection is located off the wire harness coming out of the IPI Control Board. The label is wired 'wall switch'. Connect the low voltage switch wires to the two (2) terminals labeled "wall switch" from the control
IPI SYSTEM WIRING DIAGRAM
ORANGE YELLOW BLACK
board. Run wire to desired location on wall. Up to 50 feet of 18 gauge wire may be used if necessary. Attach wires to wall switch. Mount the wall switch in a junction box and screw on cover. Figure 20
BLACK
RED
RED
RED
BLACK
RED
BROWN
RED
GROUND
RED
BLACK
GREEN
D/C POWER
BLACK
Figure 20. IPI System Wiring Diagram
Electrical connections should only be performed by a qualied, licensed electrician. Main power supply must be turned off before connecting fans to the main electrical power supply
or performing service.
CAUTION
20
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
0
System Set Up Chart
NOTE: When using ON/OFF wall switch, the master switch, located in bottom of fireplace must be in the
ON position to perform all configuration setup operations.
FUNCTION OPERATION
Cold Climate Pilot On/Off Flip the toggle switch to ON. OFF
Operations
FUNCTION OPERATION
Power Up Flip the Master Switch to ON position to power up the system.
Fireplace On
Fireplace Off
OPERATING INSTRUCTIONS – IPI
®
2.
OPERATIONS AND INDICATIONS
Cold Climate
CONTROL
BOARD
Turn on wall switch to turn the fireplace on. NOTE: If master switch was just switched to ON, then at first use of wall switch, it may need to be turned ON - OFF - ON to synchronize the two switch settings.
Turn the wall switch to the OFF position, or turn the ON/OFF master switch to the OFF position
Switch
Master Switch
DEFAULT SETTING
Self Diagnostics Chart
The fireplace has a self diagnostic LED on the control board enabling you to troubleshoot problems and potentially avoid a service call. Please refer to the chart below for indicator reference.
FUNCTION OPERATION
Sparking error Red LED, Flash 2 times
Flame error Red LED, Flash 3 times
Ignition fail Red LED, Flash 4 times
Re-ignite warning Red LED, Flash 5 times
Pilot valve voltage error Red LED, Flash 6 times
Main valve voltage error Red LED, Flash 7 times
Low battery Red LED 2.5 sec, Flash once
Remote Operations
The following functions are available on the RMSC hand held remote. NOTE: Flame height control is only available with purchase and installation of a stepper motor kit with RF receiver
REMOTE FUNCTION OPERATION ICON
Fireplace On Press the ON button on the transmitter.
Fireplace Off
Flame Height Up
Flame Height Down
Count Down Timer Mode
Press the OFF button 3 times or hold the OFF button 3 seconds for memory off.
Press the ON button once to turn on the fireplace with maximum flame setting.
Press the OFF button to lower the flame height to medium and low.
Press TIMER button to enter the timer mode. Keep pressing the TIMER button to set the desired time or press TIMER button to “0” to exit timer mode.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
21
OPERATING INSTRUCTIONS – IPI
VFC Vent Free Fireplace System
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury or loss of lie.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the
instructions.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the oor
because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re department.
C. Turn Master Switch to ON position by hand. Never use tools. If the switch will not function by hand,
do not try to repair it. Call a qualied service technician. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualied service
technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above.
2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
3. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Follow "B" in the safety information on page
38. If you do not smell gas, go to next step.
4. Press the wall switch to the "ON" (-) position. Sparker will spark and pilot ame will light.
5. Once pilot ame is established, the main burner ame will light automatically.
6. If the pilot will not stay lit after several tries, turn the master switch to "OFF" and call your service technician or gas supplier.
Wall Switch
Master Switch
TO TURN OFF GAS TO APPLIANCE
1. Turn Wall Switch to "OFF".
2. Turn Master Switch to "OFF".
3. Turn off all electrical power to the appliance if service is to be performed.
22
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
ELECTRICAL WIRING FAN
WARNING: This replace has a three-
prong, grounded electrical plug. This
plug helps protect you against electrical shock. Only connect plug to a properly
grounded, three-prong receptacle. Do not cut or remove the grounded prong from this plug.
IMPORTANT: Always check local building codes. The installation must comply with local regulations as well as the national electric codes.
If any of the original wire as supplied with the replace must be replaced, contact dealer for proper replacement wiring harness. (Refer to parts list for correct part number). 120 volts, 60Hz, 1 amp.
Fan Switch
OFF
110/115 V.A.C.
Black
White
Green
ON
WARNING: Never attempt to service
heater while it is plugged in, operating,
or hot. Burns and/or electrical shock could
result.
Electrical power cord (plug) can be routed to exit the VFC24 or VFC32 on either the left side or the right side. Remove cord protector from side of unit, route power cord through hole opposite side. Reinstall cord protector.
Thermostat Control
Blower Motor
Black
Figure 21. VFC Wiring Diagram
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
23
LOG AND MEDIA PLACEMENT
VFC Vent Free Fireplace System
WARNING: The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and rmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite
or rock wool to the heater. Only use the logs and 2G-RW rock wool supplied with the unit.
Failure to position the parts in accordance with diagrams below or to use only parts specically approved for this heater may result in property damage or personal injury.
CAST IRON GRATE INSTALLATION
Install the cast iron grate by inserting screw head on back of right side of grate into the “I” shaped slot on front right corner of unit. After moving screw head to the bottom of the “I” slot, insert the screw head on the back of the left side of grate into the keyhole slot on the left front of unit. Figure 22
A.
Key Hole Slot
Cast Iron Grate
I Slot
ROCK WOOL PLACEMENT
Before installing logs, place rock wool in dime size pieces evenly over small burner ports starting in the rear of the burner going towards the front. Avoid placing rock wool on slots on each side of rear burner and on large yellow ame ports on front of burner. After covering small burner ports, discard any excess rock wool. Figure 23
Dime-sized pieces of rock wool
Figure 23. Place Rock Wool
B.
Cast Iron Grate
Figure 22. Install Cast Iron Grate
24
WARNING: Use only rock wool
provided with log set. Do not add
additional rock wool. Place rock wool on burner ports only. Keep air gap between rear log and burner clean.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
LOG AND MEDIA PLACEMENT
LOG PLACEMENT (VFC24L AND VFC32L ONLY)
Before you begin — This unit is supplied with six (6) re­fractory cement logs. Do not handle these logs with your bare hands. Always wear gloves. After handling the logs, wash your hands gently with soap and water.
1. Place bottom right front log #1 on right pin located on burner. Rear of log will make slight contact with the front grate slot bracket. Figure 24
DO NOT sprinkle volcanic rock on the logs
or around the pilot or the main burner. This
may cause sooting. Only place volcanic
rock on the oor of the replace.
During initial operation of the new heater,
burning logs will give off a paper burning
CAUTION
smell and orange ames will be present. Simply open the windows for a few hours to vent the odor.
3. Place the middle rear log #3 with the center log placed behind the right ame bracket. T he rear log will rest on the back log support. Figure 26
Figure 24.
2. Place the right rear log #2 behind #1 locking the two logs together with the male notch into the back of log #1. Figure 25
Figure 25.
Figure 26.
4. Place the left front log #4 on the front left pin located on the burner. Left front edge of the log will make slight contact with the front grate slot bracket. Figure 27
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Figure 27.
25
LOG AND MEDIA PLACEMENT
VFC Vent Free Fireplace System
5. Place the left middle log #5 with the C channel locking
the front and middle log in place. Figure 28
Figure 28.
6. Place the left rear log #6 by aligning the rear support bracket to the cut out on the rear of log #6. The left side will also align with the channel cut into log #5. Figure 29
7. Place the top center log #7 by aligning the notch from log #3 to the bottom. The front edge of the log #7 will rest on the front grate horizontal bar. Figure 30
Figure 30.
Log placement complete.
GLASS ONLY PLACEMENT
NOTE: Two (2) bags of glass are supplied with the replace.
Both bags may be used to cover the entire oor and burner. We advise against using additional glass as too much can cut off the proper amount of air the burner needs to operate cleanly. This may cause sooting.
1. Spread glass evenly in one layer over the entire oor and burner. Be sure to use a single layer only over the ported area so as not to impinge the ame.
2. Turn burner on and adjust glass over ported areas to
achieve an even, clean ame.
Figure 29.
26
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Figure 31.
VFC Vent Free Fireplace System
FLAME APPEARANCE
PILOT AND BURNER FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.
In addition, periodically check the ames visually during operation.
MILLIVOLT CONTROL
Thermocouple for Natural Gas
Thermocouple for LP
CHECKING THE PILOT FLAME
The pilot ame must always be present when the
heater is in operation. It should just touch the top of the thermocouple tip for natural. Refer to Figure 32 for correct pilot ame.
If the pilot ame does not touch the thermocouple, then the main burner cannot function reliably. Refer to Figure 33 for incorrect shape of pilot ame.
Thermocouple for Natural Gas
Thermocouple for LP
Correct Pilot Flame Appearance Incorrect Pilot Flame Appearance
Figure 32. Millivolt Control Pilot Flame Appearance
Figure 33. Millivolt Control Incorrect Pilot Flame Appearance
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
27
FLAME APPEARANCE
VFC Vent Free Fireplace System
CHECKING BURNER FLAME
VFC24L/VFC32L MODELS In normal operation at full rate after 15 minutes, the following ame appearances should be observed: Burner will have a random pattern of yellow ames. Figure 34 There should be glowing embers in front of burner. NOTE: The front ames and embers will be an opaque orange color during the burn off time.
VFC24C/VFC32C MODELS In normal operation at full rate after 15 minutes, the following ame appearances should be observed: Burner will have a random pattern of yellow ames. Figure 35
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner ame patterns. Do not allow fans to blow directly into the replace. Do not place a blower inside the burn area of the rebox. Ceiling fans may create drafts that alter ame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, lms or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the replace.
Figure 34. VFC Traditional Flame Appearance
Figure 35. VFC Contemporary Flame Appearance
28
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instruction exactly, a re or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with a piezo ignition device which automatically lights the pilot. If the piezo
is not working properly see Match Lighting Instructions.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the oor
because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re department.
C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push
in or turn by hand, don't try to repair it. Call a qualied service technician. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualied service
technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
On/Off Switch
Piezo Ignitor Control Knobs
Blower Control
Location of Piezo Ignitor, Control Knobs and Switch on Millivolt Unit, Hi/Lo Remote Control and Manual Unit
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
29
OPERATING INSTRUCTIONS
VFC Vent Free Fireplace System
MILLIVOLT/THERMOSTAT CONTROL
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for Match Lighting Instructions on the following page.
4. Turn gas control knob clockwise to the OFF position and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise knob for 5 seconds. NOTE: If you are running the heater for the rst time, it will be necessary to
press in the control knob for 30 seconds to allow air to bleed out of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the ame detector from shut­ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” below and call your service technician or gas supplier.
to IGN position. Push in control
Pilot
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
30
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
On/Off Switch
Piezo Ignitor
Control Knobs
Millivolt Controls
Blower Control
VFC Vent Free Fireplace System
OPERATING INSTRUCTIONS
MATCH LIGHTING INSTRUCTIONS
1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the ame to the end of the pilot and ignite the pilot.
3. After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.
4. Call a qualied service technician for repair or replacement of the piezo ignitor.
BLOWER OPERATION
Figure 36. Location of Blower Control
Locate the blower control by opening control access door. The variable controlled thermostat blower is located to the right of heater controls. .
In the OFF position, the blower will not operate; however, the heater can be operated without the blower being ON. In the ON (AUTO) position, the blower will start when the ther­mostat senses a sufcient increase in rebox temperature.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Blower Control
NOTE: Your gas logs and blower will not turn on and off at the same time. The gas logs may burn several minutes before blower turns on. The blower will continue to run for several minutes after the ames have turned off.
31
CLEANING AND SERVICING
WARNING: Turn off heater and allow to cool before cleaning. Disconnect electrical
power before cleaning or servicing.
VFC Vent Free Fireplace System
ANNUAL CLEANING/INSPECTION
Refer to parts diagram for location of items discussed below.
Annual inspection and cleaning by your dealer or qualied service technician is recommended to prevent malfunction and/or sooting. Remove logs, handling carefully by holding gently at each end. Gloves are recommended. If skin becomes irritated, wash gently with soap and water. Refer to manual for correct log placement.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion.
Inspect and clean all burner ports.
Inspect ODS pilot for operation and accumulation of
lint at air intake holes.
Verify ame pattern and log placement for proper
operation.
Verify smooth and responsive ignition of main burner
and rear burner.
PERIODIC CLEANING
Refer to parts diagram for location of items discussed below.
Do not use cleaning uid to clean logs or any part of
heater.
Brush logs with soft bristle brush or vacuum with
brush attachment.
Vacuum loose particles and dust from the front and
rear burner, control and piezo covers and grate weldment.
Inspect and clean burner air intake holes. Remove
lint or particles with vacuum, brush, or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion.
External case should be dusted and wiped with a
wet soapy cloth.
32
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
FORCED AIR KIT
If you are installing the forced air kit (Models BLO24T or BLOT), see the installation instructions provided with the kit for electrical wiring requirements or the blower instal­lation section.
Model VFC24 uses blower model BLO24T. Model VFC32 uses blower model BLOT.
The rebox must be connected to main power supply at time of rebox installation. The blower must be installed prior to the installation of the unvented heater. The electri­cal connections must be made before the rebox is framed and enclosed in the nished walls.
INSTALLING OPTIONAL FIREBRICK PANELS
NOTE: Firebrick liner kits may be used only with the VFC
vent free replace systems. Please verify the size and model number of your insert to be certain the kit you pur­chased is correct.
OPTIONAL ACCESSORIES
Retainer Brackets
Figure 37. Install Side Firebrick Panel
KIT CONTENTS:
• One (1) Center panel
• Two (2) self-drilling #8 screws
• One (1) Left panel
• Two (2) Brick retainer brackets
• One (1) Right panel
TOOLS REQUIRED:
Drill with 1/4" hex head or Phillips bit
INSTRUCTIONS:
1. Remove screen frame, stones, reglass or logs (if ap­plicable) per the VFC Installation and Operating In­structions.
2. Place rear ceramic rebrick panel against the center of the rear wall of the rebox. Place on rear log support bracket.
3. Place left and right ceramic rebrick panels against rebox sides and attach at the top with retainer bracket with supplied self drilling screws.
4. Replace reglass, stones and/or logs as applicable and re-install screen frame.
Figure 38. Install Back Firebrick Panel
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
33
VFC Vent Free Fireplace System
INSTALLING OPTIONAL PORCELAIN PANELS
NOTE: Porcelain liner kits are approved for use with op-
tional reglass and log kits. These kits are designed to t VFC vent free replace systems. Please verify the size and model number of your replace to be certain the kit you purchased is correct.
KIT CONTENTS:
• One (1) Right panel
• One (1) Left panel
• One (1) Rear panel
• Four (4) Self-drilling #8 screws
INSTALLATION INSTRUCTIONS:
1. Remove screen frame, stones, reglass or logs (if ap­plicable).
2. Place rear panel against the center of the rear wall of the rebox.
3. Place left and right panels against rebox sides and at­tach top anges of the panels using self-drilling screws provided.
4. Replace reglass or logs as applicable and re-install screen frame.
INSTALLING OPTIONAL BLACK MAGIC PANELS
NOTE: Black Magic glass liner kits are approved for
use with optional reglass and log kits. These kits are designed to t VFC vent free replace systems. Please verify the size and model number of your replace to be certain the kit you purchased is correct.
KIT CONTENTS:
• One (1) Center panel
• One (1) Left panel
• One (1) Right panel
• Two (2) Glass retainer brackets
• Two (2) Self drilling #8 screws
INSTALLATION INSTRUCTIONS:
1. Remove screen frame, reglass or logs (if applicable).
2. NOTE: All panels will be installed with the dimples in the glass facing the rebox.
Place rear glass liner panel against the center of the
rear wall of the rebox.
3. Place left and right glass liner panels against rebox sides and attach at the top with retainer bracket using supplied screws.
4. Replace reglass or logs as applicable and re-install screen frame.
Figure 39. Install Porcelain Panels
34
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Figure 40. Install Black Magic Glass Panels
VFC Vent Free Fireplace System
WARNING: Turn appliance OFF and allow to cool before servicing. Only a qualied
service person should service and repair the heater.
NOTE: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM POSSIBLE CAUSE SOLUTION
When ignitor button is pressed, there is no spark at ODS/pilot.
Appliance produces unwanted odors.
Appliance shuts off during use. 1. Not enough fresh air is available for
Gas odor even when control knob is in OFF position.
1. Ignitor electrode positioned wrong.
2. Ignitor electrode is broken.
3. Ignitor electrode not connected to ignitor cable.
4. Ignitor cable pinched or wet. Keep ignitor cable dry.
5. Broken ignitor cable.
6. Bad piezo ignitor.
1. Appliance burning vapors from paint, hair spray, glues, etc.
2. Gas leak.
3. Initial burn off.
ODS/ pilot to operate.
2. Low line pressure.
3. ODS/pilot is partially clogged.
4. Defective Thermopile.
5. Restrictions in incoming air ow
1. Gas leak.
2. Control valve defective.
1 Replace ignitor.
2. Replace ignitor.
3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by any metal or tubing.
5. Replace ignitor cable.
6. Replace piezo ignitor.
1. Ventilate room. Stop using odor causing prod­ucts while heater is running.
2. Locate and correct all leaks.
3. Ventilate room and turn unit on high until odor is gone. Odor should be gone after 6 hours of continuous use.
1. Open window and/or door for ventilation.
2. Contact local gas company.
3. Clean ODS/pilot.
4. Check pilot ame, check wire connections, check output, should be 325 millivolts across TH/TP and TP Terminals with ON/OFF switches off.
5. Check for bottom riser on glass door, sunken replace, excessive lava rock/cinders densely packed against grate.
1. Locate and correct all leaks.
2. Replace control valve.
TROUBLESHOOTING
When ignitor button is pressed, there is spark at ODS pilot, but no ignition.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
1. Gas supply turned off or manual shutoff valve closed.
2. Control knob not in PILOT position.
3. Control knob not pressed in while in PILOT position.
4. Air in gas lines when installed.
5. ODS/pilot is clogged.
6. Gas regulator setting is not correct.
1. Turn on gas supply or open manual shutoff valve.
2. Turn control knob to PILOT position.
3. Press in control knob while in PILOT position.
4. Continue holding down control knob. Repeat igniting operation until air is removed.
5. Replace ODS/pilot assembly or get it serviced.
6. Replace gas regulator.
continued on following page
35
TROUBLESHOOTING
OBSERVED PROBLEM POSSIBLE CAUSE SOLUTION
ODS/pilot lights, but flame goes out when control knob is released.
Burner does not light after ODS/pilot is lit.
Burner backres during com­bustion.
Slight smoke or odor during initial operation.
Logs appear to smoke after initial operation.
Heater produces a whistling noise when burner is lit.
No gas to pilot. 1. LP-regulator shut down due to inlet
Blower does not work. 1. Power cord not plugged in.
1. Control knob not fully pressed in.
2. Control knob not pressed in long enough.
3. Manual shutoff valve not fully open.
4. Thermocouple connection loose at control valve.
5. Pilot ame not touching thermocou­ple, which allows thermocouple to cool, causing pilot ame to go out. This problem could be caused by either low gas pressure, or a dirty or partially clogged ODS/pilot.
6. Thermocouple damaged.
7. Control valve damaged.
1. Burner orice is clogged.
2. Burner orice diameter is too small.
3. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orice is clogged.
1. Burner orice is clogged or dam­aged.
2. Burner is damaged.
3. Gas regulator defective.
1. Vapors from paint or curing process of logs.
2. Vapors or smoke continue after heater is run with damper or window open for several hours.
1. Turning control knob to HIGH posi­tion when burner is cold.
2. Air in gas line.
3. Dirty or partially clogged burner ori­ces.
pressure too high.
2. Loose wire connections.
3. Defective blower thermostat.
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in for 30 seconds.
3. Fully open manual shutoff valve.
4. Hand tighten thermocouple connection until snug, then tighten 1/4 turn more.
5a.Contact local gas company. 5b.Clean pilot with vacuum cleaner.
6. Replace thermocouple.
7. Replace control valve.
1. Clean orice.
2.
Replace burner orice.
3.
Contact qualied service person.
1. Contact local gas company.
2. Clean burner or replace burner orice.
1. Clean burner or replace burner orice.
2. Replace burner.
3. Replace gas regulator.
1. Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the rst few hours.
2. Log heater is intended to be smokeless. Turn OFF heater and call qualied service person.
1. Turn control knob to LOW position and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by local gas company.
3. Clean burner or replace burner orice.
1. Verify LP tank regulator is installed and set at 11" to 13" w.c.
2. Replace regulator on heater.
1. Plug power cord into junction box found in lower access level.
2. Check wire connections, reconnect if loose.
3. Replace thermostat.
VFC Vent Free Fireplace System
WARNING: If the gas quality is bad, your pilot may not stay lit, the burners may produce
soot and the heater may backre when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
36
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
IPI SYSTEM
TROUBLESHOOTING
Flip the master switch to the
ON position
Press the wall switch to the
ON position
No beep or flashing
green light in about 5
seconds
No beep
No sound from valve indicating
pilot solenoid
opened
No spark at pilot
Pilot doesn't light
Main burner doesn't light
Make sure control board is
connected to battery pack wire
harness. Make sure AC
adaptor is plugged into control
Check wiring connections
between switch and board
Check wiring connections between valve and board
Inspect gray ignitor wire
connection at board and pilot.
Check gas supply.
Flame not engulfing flame
sensor or pilot flame too
Battery polarity wrong?
Batteries low? Change batteries.
AC adaptor plugged into
junction box?
Check that ground
wire has solid
connection
Reinstall batteries correctly.
Plug the AC adaptor in
Correct wiring if necessary
Correct wiring if necessary
Reconnect wire if disconne cted.
Replace ignitor wire if damaged.
Adjust sparker position such that t he spark is in the path of the gas flow or
replace the pilot
Adjust sensor position or replace the
pilot.
Cold climate switch
No function Check the cold climate switch and control
Replace cold climate switch
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
37
REPLACEMENT PARTS
VFC FIREBOX PARTS
VFC Vent Free Fireplace System
1
3
2
REF. DESCRIPTION QTY VFC24 VFC32
1. CANOPY 1 20308038K 20307978K
2. SCREEN ASSEMBLY 1 20308061K 20307979K
3. LEFT FIREBRICK (OPTIONAL) 1
4. CENTER FIREBRICK (OPTIONAL) 1
5. RIGHT FIREBRICK (OPTIONAL) 1
6. BLOWER (OPTIONAL) 1 BLOT24T BLOT
N/A LEFT PORCELAIN PANEL (OPTIONAL) 1 20307939K 20307814K
N/A CENTER PORCELAIN PANEL (OPTIONAL) 1 20307937K 20307812K
N/A RIGHT PORCELAIN PANEL (OPTIONAL) 1 20307938K 20307813K
N/A LEFT BLACK MAGIC GLASS PANEL (OPTIONAL) 1 20307944K 20307941K
KN/A CENTER BLACK MAGIC GLASS PANEL (OPTIONAL) 1 20307943K 2030794K
N/A RIGHT BLACK MAGIC GLASS PANEL (OPTIONAL) 1 20307945K 20307942K
4
5
6
20308191K
(CINNAMON)
20308190K
(CINNAMON)
20308192K
(CINNAMON)
20307935K
(COLONIAL RED)
20307934K
(COLONIAL RED)
20307936K
(COLONIAL RED)
20307926K
(CINNAMON)
20307925K
(CINNAMON)
20307927K
(CINNAMON)
20307929K
(COLONIAL RED)
20307928K
(COLONIAL RED)
20307930K
(COLONIAL RED)
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
38
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
VFC24 MILLIVOLT BURNER PARTS
REPLACEMENT PARTS
1
5
10
11
2
3
6
7
4
9
8
REF DESCRIPTION QTY VFC24CNV VFC24CPV VFC24LNV VFC24LPV
1 On/Off Switch 1 32D0232 32D0232 32D0232 32D0232
2 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503
3 ODS Pilot Assembly 1 14D0473 14D0477 14D0473 14D0477
4 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632
5 Control Valve 1 14D0467 14D0468 14D0467 14D0468
6 Pilot Regulator 1 14D0469 N/A 14D0469 N/A
7 Burner Injector 1 20H3155 33D4046 20H3155 33D4046
8 Female Valve/Switch Wire 1 44D0500 44D0500 44D0500 44D0500
9 Male Valve/Switch Wire 1 44D0501 44D0501 44D0501 44D0501
10 Knob Extender 1.5" Hi/Low 1 37D0011 37D0011 37D0011 37D0011
11 Knob Extender 1.5" On/Off 1 37D0010 37D0010 37D0010 37D0010
ACCESSORIES
Flex Connector FLEXCON18
Wall Switch Kit MVWS
Hand Held Remote RCB, RCMT, TSMT
Hand Held Thermostat Remote RCST, TSST
Thermostat Sensor Kit TS
Rock Wool 81D2011 (TRADITIONAL ONLY)
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
39
REPLACEMENT PARTS
VFC24 IPI BURNER PARTS
VFC Vent Free Fireplace System
1
7
2
8
3
4
5
10
9
6
12
11
REF DESCRIPTION QTY VFC24CNI VFC24CPI VFC24LNI VFC24LPI
1 Cold Climate Switch 1
2 On/Off Switch 1
3 Gas Valve 1
4 Control Box 1
5 ODS Module 1
6 ODS Pilot Assembly 1
7 ODS Module Wire 1
8 Control to ODS Module Wire 1
9 A/C Adapter 1
10 Burner Injector 1
11 Pilot Regulator 1
12 Piezo Wire 1
95E0111 95E0111 95E0111 95E0111
32D0232 32D0232 32D0232 32D0232
20307838K 20307839K 20307838K 20307839K
95E0100 95E0100 95E0100 95E0100
20303179 20303179 20303179 20303179
26D2529 14D0476 26D2529 14D0476
20301890 20301890 20301890 20301890
95E0120 95E0120 95E0120 95E0120
95E0105 95E0105 95E0105 95E0105
20H3155 33D4046 20H3155 33D4046
14D0469 N/A 14D0469 N/A
20303256K 20303256K 20303256K 20303256K
ACCESSORIES
Wall Switch Kit MVWS
Hand Held Remote RCB, RCMT, TSMT
Hand Held Thermostat Remote RCST, TSST
Thermostat Sensor Kit TS
Rock Wool 81D2011 (TRADITIONAL ONLY)
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
40
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
VFC32 MILLIVOLT BURNER PARTS
1
2
REPLACEMENT PARTS
3
4
5
10
11
6
7
8
9
REF DESCRIPTION QTY VFC32CNV VFC32CPV VFC32LNV VFC32LPV
1 On/Off Switch 1 32D0232 32D0232 32D0232 32D0232
2 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503
3 ODS Pilot Assembly 1 14D0473 14D0477 14D0473 14D0477
4 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632
5 Control Valve 1 14D0467 14D0468 14D0467 14D0468
6 Pilot Regulator 1 14D0469 N/A 14D0469 N/A
7 Burner Injector 1 33D5040 58D0052 33D5040 58D0052
8 Female Valve/Switch Wire 1 44D0500 44D0500 44D0500 44D0500
9 Male Valve/Switch Wire 1 44D0501 44D0501 44D0501 44D0501
10 Knob Extender 1.5" Hi/Low 1 37D0011 37D0011 37D0011 37D0011
11 Knob Extender 1.5" On/Off 1 37D0010 37D0010 37D0010 37D0010
ACCESSORIES
Flex Connector FLEXCON18
Wall Switch Kit MVWS
Hand Held Remote RCB, RCMT, TSMT
Hand Held Thermostat Remote RCST, TSST
Thermostat Sensor Kit TS
Rock Wool 81D2011 (TRADITIONAL ONLY)
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
41
REPLACEMENT PARTS
VFC32 IPI BURNER PARTS
VFC Vent Free Fireplace System
1
7
2
8
3
4
5
10
9
6
12
11
REF DESCRIPTION QTY VFC32CNI VFC32CPI VFC32LNI VFC32LPI
1 Cold Climate Switch 1
2 On/Off Switch 1
3 Gas Valve 1
4 Control Box 1
5 ODS Module 1
6 ODS Pilot Assembly 1
7 ODS Module Wire 1
8 Control to ODS Module Wire 1
9 A/C Adapter 1
10 Burner Injector 1
11 Pilot Regulator 1
12 Piezo Wire 1
95E0111 95E0111 95E0111 95E0111
32D0232 32D0232 32D0232 32D0232
20307838K 20307839K 20307838K 20307839K
95E0100 95E0100 95E0100 95E0100
20303179 20303179 20303179 20303179
26D2529 14D0476 26D2529 14D0476
20301890 20301890 20301890 20301890
95E0120 95E0120 95E0120 95E0120
95E0105 95E0105 95E0105 95E0105
33D5040 58D0052 33D5040 58D0052
14D0469 N/A 14D0469 N/A
20303256K 20303256K 20303256K 20303256K
ACCESSORIES
Wall Switch Kit MVWS
Hand Held Remote RCB, RCMT, TSMT
Hand Held Thermostat Remote RCST, TSST
Thermostat Sensor Kit TS
Rock Wool 81D2011 (TRADITIONAL ONLY)
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
42
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
VFC Vent Free Fireplace System
6
REPLACEMENT LOGS
REPLACEMENT PARTS
3
2
5
7
4
1
REF QUANTITY VFC24 AND VFC32 REPLACEMENT PART NO.
LOG # 1 1 20308256K
LOG # 2 1 20308257K
LOG # 3 1 20308258K
LOG # 4 1 20308259K
LOG # 5 1 20308260K
LOG # 6 1 20308261K
LOG # 7 1 20308262K
WARNING: Failure to position the parts in accordance with these diagrams or failure to
use only parts specically approved with this appliance may result in property damage or personal injury.
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
43
VFC Vent Free Fireplace System
LIMITED LIFETIME WARRANTY POLICY
LIFETIME WARRANTY
The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners.
FIVE YEAR WARRANTY
The following components are warranted for 5 years to the original owner, subject of proof of pur­chase: Refractory cement Logs, Catalytic Filter and Aluminized Burners.
BASIC WARRANTY
Monessen warrants the components and materials in your gas appliance to be free from manufac­turing and material defects for a period of one year from date of installation. After installation, if any of the components manufactured by Monessen in the appliance are found to be defective in mate­rials or workmanship, Monessen will, at its option, replace or repair the defective components at no charge to the original owner. Monessen will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of one year from the date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.
This Limited Warranty will be void if the appliance is not installed by a qualied installer in accordance with the installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) rebox/burner assembly damage by accident, neglect, misuse, abuse, alteration, negligence of others, including the installation thereof by unqualied installers, (2) the costs of removal, re-installation or transportation of defective parts on the appliance, or (3) incidental or consequential damage. All service work must be performed by an authorized service representative.
This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of tness for purpose and of all other obligations or liabilities. Monessen does not assume for it any other obligations or liability in connection with the sale or use of the appliance. In states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damages, those limitations of exclusions may not apply to you. You may also have additional rights not covered in this Limited Warranty.
Monessen reserves the right to investigate any and all claims against the Limited Warranty and de­cide upon method of settlement.
IF WARRANTY SERVICE IS NEEDED...
1. Contact your supplier. Make sure you have your warranty, your sales receipt and the model/ serial number of your Monessen product.
2. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
44
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev A • 06/16
Monessen, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 50044
www.monessenhearth.com