Monessen Hearth SDV500, SDV600 Installation And Operating Instructions Manual

SDV SERIES
DIRECT VENT GAS FIREPLACE
INSTALLATION AND OPERATING INSTRUCTIONS
MODELS:
SDV500 and SDV600
IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
* Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
WARNINGS
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
CONTENTS
Thank you and congratulations on your purchase of a
Monessen Hearth Systems Fireplace.
PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE!
IMPORTANT: Read all instructions and warnings carefully before starting installation.
Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
Important Safety Information .......................... 3
Product Features .............................................. 5
Code Approval .................................................. 5
Pre-Installation Information
Installing Above 2000 Feet ............................ 6
Orifice Sizes, Pressures and BTUs ............... 6
Before You Install .......................................... 6
Fireplace Framing ......................................... 7
Fireplace Dimensions ................................... 8
Fireplace Location ....................................... 10
Clearances .......................................................11
Securing Fireplace to Floor or Framing ....... 12
Installation Information .................................. 13
Vent Installation .............................................. 13
Installation Precautions ............................... 13
Optional Top Vent Application ..................... 15
Installation Planning .................................... 16
Installation for Vertical Termination ............. 16
Rear Wall Vent Installation .......................... 19
Horizontal (Through the Wall) Termination
Configurations ............................................. 21
Below Grade Installation ............................. 23
Vertical Through-the-Roof Installation ......... 24
Installation for Vertical Termination ............. 26
Flat Ceiling Installation ................................ 26
Fireplace Installation ...................................... 28
Check Gas Type .......................................... 28
Installing Gas Piping to Fireplace/Burner
System Location ......................................... 28
Checking Gas Pressure ................................. 30
Electrical Installation ..................................... 31
Electrical Wiring .......................................... 31
Remote Wall Mounted Switch ..................... 31
Electronic Pilot Ignition Wiring .................... 32
Canopy Installation ........................................ 33
Glass Removal ................................................ 35
Rockwool Placement ..................................... 35
Lava Rock and Embers Placement ............. 35
Andiron Installation ....................................... 36
Log Placement ................................................ 37
Operating Instructions ................................... 39
What To Do If You Smell Gas ...................... 39
Lighting Pilot for the First Time ................... 39
Lighting Pilot ............................................... 40
Lighting Burner ............................................ 40
Lighting electronic IGN ................................ 41
To Turn Off Gas ........................................... 41
Cleaning and Maintenance ............................ 42
Burmer, Pilot and Control Compartment ..... 42
Burmer Flame ............................................. 42
Vent System ................................................ 43
Glass Door .................................................. 43
Logs ............................................................ 43
Rock Wool .................................................. 43
Replacement Parts ......................................... 45
Vent Components ....................................... 45
Firebox Components ................................... 46
Logs ............................................................ 47
Additional Accessories ............................... 48
Standing Pilot - Millivolt Control .................. 50
Electronic Ignition ........................................ 52
2 56D0106
Troubleshooting ............................................. 54
Warranty ...........................................Back Cover
IMPORTANT SAFETY INFORMATION
INSTALLER
Please leave these instructions with the owner.
• Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.
• Any change to this fireplace or its controls can be dangerous.
• Improper installation or use of this fireplace can cause serious injury or death from
WARNING
fire, burns, explosions, electrical shock and carbon monoxide poisoning.
This fireplace is a vented product. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, combustion leakage can occur.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with head­aches, dizziness and/or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have the fireplace inspected and serviced by a quali­fied service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane/LP gas and natural gas are both odorless. An odor­making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
1. This appliance is only for use with the type of gas indi cated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
3. If you smell gas
• shut off gas supply.
• do not try to light any appliance.
• do not touch any electrical switch; do not use any
phone in your building .
• immediately call your gas supplier from a neighborʼs
phone. Follow the gas supplierʼs instructions.
-
OWNER
Please retain these instructions for future reference
4. Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace
• in high traffic areas
• in windy or drafty areas
5. This fireplace reaches high temperatures. Keep children
and adults away from hot surfaces to avoid burns or cloth­ing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
6. Carefully supervise young children when they are in the
room with fireplace.
7. Do not modify fireplace under any circumstances. Any
parts removed for servicing must be replaced prior to operating fireplace.
8. Turn fireplace off and let cool before servicing, install
ing, or repairing. Only a qualified service person should install, service, or repair the fireplace. Have burner system inspected annually by a qualified service person.
9. You must keep control compartments, burners, and cir-
culating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, pet hair, etc. Turn off the gas valve and pilot light before cleaning fireplace.
10. Have venting system inspected annually by a qualified
service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 32.
11. Keep the area around your fireplace clear of combustible
materials, gasoline, and other flammable vapor and liq­uids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.
Continued on page 4
.
-
56D0106 3
IMPORTANT SAFETY INFORMATION
Continued from page 3
12. Do not use this fireplace to cook food or burn paper or other objects.
13. Never place anything on top of fireplace.
14. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on rating plate.
15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
16. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation.
17. When the appliance is installed directly on carpeting, tile or other combustible material other than wood floor­ing, you must set appliance on a metal or wood panel or hearth pad extending the full width and depth of the appliance.
18. Do not use fireplace if any part has been exposed to or has been under water. Immediately call a qualified service person to arrange for replacement of the unit.
19. Do not operate fireplace if any log is broken.
20. Do not use a blower insert, heat exchanger insert, or any other accessory not approved for use with this fire
-
place.
IMPORTANT:
PLEASE READ THE FOLLOWING CAREFULLY
It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.
IMPORTANT:
PLEASE READ THE FOLLOWING CAREFULLY
It is not unusual for gas fireplace to give off some odor the first time it is burned. This is due to the manufacturing process.
Please ensure that your room is well ventilated
during burn off — open all windows.
It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. Place the fan switch in the “OFF” position during this time.
We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute
®
(NFI) as Gas Specialists.
www.nficertified.org
21. Do not operate the fireplace with glass door removed, cracked, or broken.
22. For Massachusetts Residents Only: This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Flexline installation must not exceed 36".
4 56D0106
Never connect unit to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
WARNING
PRODUCT SPECIFICATIONS
This appliance has been certified for
use with either natural or propane gas. See appropriate data plates.
• This appliance is not for use with
solid fuels.
PRODUCT FEATURES AND CODE APPROVAL
• The appliance is approved for bed-
room or bedsitting room installa­tions.
• The appliance must be installed in
accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CAN/CGA B149 in Canada.
• This appliance is mobile home
approved.
The appliance must be properly con-
nected to a venting system.
• The appliance is not approved for
closet or recessed installations.
The efficiency rating of this appliance is a product thermal efficiency rating deter­mined under continuous operating condi­tions and was determined independently of any installed system.
Thermal Efficiency = up to 80%
Hi/Lo Knob
Off/Pilot/On Knob
Hood
1
/2" Nailing
Flage
Nailing
Flage
5
/8"
On/Off/RS Switch
Figure 1 - SDV500 and SDV600 Fireplace
CODE APPROVAL
Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe.
These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows:
LISTED VENTED GAS FIREPLACE HEATER
TESTED TO: ANSI Z21.88-2002/CSA 2.33-2002 STANDARDS
A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Con struction and Safety Standard, Title 24 CFR, Part 3280, or when such a standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
56D0106 5
Ignitor
Blower Control
Optional Remote
Receiver
1
/2" Nailing
Flage
-
PRE-INSTALLATION INFORMATION
INSTALLING ABOVE 2000 FEET
In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations
between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS PROPANE GAS
Manifold Press: (W.C.) 3.5" Manifold Press: (W.C.) 10" Maximum Supply Pressure 10.5" Maximum Supply Pressure 13" Minimum Supply Pressure 4.5" Minimum Supply Pressure 11"
Model Number SDV500 SDV600
Natural Propane Natural Propane
Max. Btu/hr Input 30,000 30,000 32,000 32,000
Min. Btu/hr Input 22,000 22,000 25,000 25,000
Burner Orifice size (as shipped) #37 #52 #34 #51
BEFORE YOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:
• Fireplace (Firebox and Burner System) • Plastic Bag (1) • Ziplock Bag 2"x3"x3"
• White Toggle Switch (1) • Volcanic Rock • Rock Wool
• Log Set • Switch Cover Plate (1) • Restrictor Plate/Disc
• Canopy • Andirons (2)
ITEMS REQUIRED FOR INSTALLATION
Tools: Building Supplies:
• Phillips Screwdriver • Framing Materials
• Hammer • Wall Finishing Materials
• Saw and/or saber saw • Caulking Material (Noncombustible)
• Level • Fireplace Surround Material (Noncombustible)
• Measuring Tape • Piping Complying with Local Codes
• Electric Drill and Bits • Tee Joint
• Pliers • Pipe Sealant Approved for use with Propane/LPG
• Square (Resistant to Sulfur Compounds)
• Pipe Wrench
6 56D0106
FIREPLACE FRAMING
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 and the chart below for your specific installation requirements. See Figures 3 and 4 on Pages 8 and 9 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure.
Do not fill spaces around firebox with insulation or other materials. This could cause a fire.
WARNING
SDV
A 419/16" 479/16" B 471/4" 471/4" C 305/8" 365/8" D 211/2" 25" E 641/2" 731/2" F 42 G 2113/16" 2113/16" H 53" 573/4"
500 SDV600
5
/64" 453/4"
Corner Installation
C
A
Inside Chase Installation
C
G
1
/2" or 5/8"
G
Stud Location
56D0106 7
Recessed Installation
Figure 2 - Framing Dimensions
A
1
/2" or 5/8"
PRE-INSTALLATION INFORMATION
SDV500
5
/8"
30
155/16"
45
13
/16"
36
20
5
/8"
2241/64"
165/16"
43
2
/64"
5
/8"
1
9
2
/16"
/2"
425/8"
23
22
3
/8"
/64"
40"
381/2"
Center
of Pipe
1
/2"
5
/8"
1"
Figure 3 - SDV500 Fireplace Dimensions
8 56D0106
33
41
1
36"
1
/16"
/16"
3
8
/8"
"
SDV600
185/16"
36
5
PRE-INSTALLATION INFORMATION
/8"
4513/16"
36
3
/8"
205/8"
22
165/16"
9
/16"
2
23
/64"
243/64"
2241/64"
40"
5
1
1
/8"
/2"
425/8
381/2"
Center
of Pipe
/2"
1"
Figure 4 - SDV600 Fireplace Dimensions
56D0106 9
39
47
1
/16"
42"
1
/16"
5
/8"
83/8"
PRE-INSTALLATION INFORMATION
FIREPLACE LOCATION
Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspec­tions.
The following factors should be taken into consideration:
Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles must be maintained.
This fireplace may be installed along a wall, across a corner, or use an exterior chase. See Figure 5 for suggested loca-
tions.
Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance.
Never obstruct the front opening of the fireplace.
• Do
not install in the vicinity where gasoline or other flammable liquids may be stored.
Vent pipe routing. See Venting section found in this manual for allowable venting configurations.
These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54 — (current edition), the
Uniform Mechanical Code — (current edition), and Local Building Codes for specific installation requirements.
A Flat on Wall B Cross Corner C Island**
D Room Divider* E Flat on Wall Corner*
F Chase Installation Y 4" Minimum
Figure 5 - Locating Gas Fireplace
** Island (C) and room divider (D) installation is possible as long as the horizontal portion of vent system (X)
does not exceed 20'. See Installing Horizontal Termination Configuration on pages 18 and 19.
* When you install your fireplace in (D) room divider or (E) flat on wall corner positions (Y), a minimum of 4"
clearance must be maintained from perpendicular wall and front of fireplace.
10 56D0106
SECURING FIREPLACE TO FLOOR OR FRAMING
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6 . Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets are adjustable from 1/2" to 5/8" to accommodate different thickness of material.
Framing
1
/2" Nail
Flange
Screws
Screws
1
/2" Nail
Flange
Screws
5
/8" Nail
Flange
Screws
Framing
1
/2" Nail
Flange
Screws
5
/8" Nail
Flange
Figure 6 - Securing Fireplace to Floor and Framing Studs
56D0106 11
1
/2" Nail
Flange
CLEARANCES
CLEARANCES TO COMBUSTIBLES
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of
WARNING
the appliance.
71" Minimum
12" Minimum
12"
Maximum
Depth












Minimum 3"
From Both Side Walls
MANTEL CLEARANCES
NOTE: The combustible area around the fireplace must not protrude more than 1/2" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
12 56D0106
Figure 7 - Clearances
INSTALLATION INFORMATION
FINISHING MATERIAL
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.
Never obstruct or modify the air inlet or outlet grills (louvers). This may create a fire hazard.
WARNING
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the black surface of the appliance. A 300 the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must
be used.
VENT INSTALLATION
°F minimum adhesive may be used to attach facing materials to the black surface. If joints between
Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
WARNING
Failure to follow these instructions will void the warranty.
NOTICE
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.
Only a qualified installer/service person should install venting system. The installer must follow these safety rules:
• Wear gloves and safety glasses for protection.
• Use extreme caution when using ladders or when on rooftops.
• Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your venting system:
• Installation of any damaged venting component.
• Unauthorized modification of the venting system.
• Installation of any component part not manufactured or approved by Monessen Hearth Systems
• Installation other than permitted by these instructions.
56D0106 13
VENT INSTALLATION
This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.
WARNING
Horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all around the flue is acceptable at this point of penetration.
WARNING
Vertical sections of this vent system require a minimum of 1" clearance to combustibles on all sides of the pipe.
Maintain 3"
θ
A Minimum of 3" Clearance
to the Top Is Required Along
Horizontal Length until Flue
Pipe Penetrates Outside Wall.
1"
1"
1"
1"
A Minimum 1"
Clearance to
Combustibles
Permitted All
Around Flue at
Outside Wall
Figure 8 - Combustible Clearances for Vent Pipe
14 56D0106
OPTIONAL TOP VENT APPLICATION
VENT INSTALLATION
The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration the appli­ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.
1. Remove the eight (8) screws securing the flue pipe adapter
to the fireplace body. See Figure 9.
2. Set the flue pipe adapter aside, complete with the gasket.
Do not damage the gaskets as the adapter and gasket must be refitted.
3. Remove the six (6) screws securing the flue pipe cover to
the top of the intake box and remove the cover and gasket.
See Figure 9.
4. Remove six (6) screws securing the flue pipe to the back
of the intake box and remove the pipe and gasket. See
Figure 10.
5. Replace flue pipe to top of firebox. Ensure the gasket is
in place and undamaged. Secure with six (6) screws. See
Figure 10.
6. Place the flue pipe cover and gasket removed in step 3
over the flue opening in bottom of the intake box.
After conversion to top vent configuration the 4" (100mm) flue pipe should be concentric with the
5
6
/8" (175mm) outer collar within 1/4".
WARNING
Flue Pipe
Cover
Flue Pipe
Adapter
Screws
7. Refit the flue pipe adapter and gasket to the top of fire
place. Secure the adapter with six (6) screws removed in step 1.
Flue
Cover
Flue Pipe
Screws
-
Figure 9 - Removing sixteen (16) Screws from
Flue Pipe Adapter and Flue Pipe Cover
Flue Pipe
Screws
Figure 10 - Removing Flue Pipe
56D0106 15
Figure 11 - Attaching Flue Pipe to Top
Vent Configurations
VENT INSTALLATION
INSTALLATION PLANNING
There are two basic types of direct-vent installation:
• Horizontal Termination
• Vertical Termination
It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
FOR HORIZONTAL TERMINATION
Select the amount of vertical rise desired. All horizontal run of venting must have termination.
You may use up to three 90° elbows in this vent configuration. See Horizontal Termination Configurations on pages 20 and 21.
FOR VERTICAL TERMINATION
Measure the distance from the fireplace floor to the ceiling. Add the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roof line.
NOTE: You may use two 45° elbows in place of a 90° elbow. You must follow rise to run ratios when using 45° elbows. The appliance is approved for use with three 90° elbows maximum or a combination of 90° and 45° elbows up to a maximum of 270°.
For two-story applications, firestops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required.
You may use a chase with a vent termination with exposed pipe on the exterior of the house. See Installing Vent System in a Chase below. If pipe is enclosed in chase, it is not exposed.
It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed.
INSTALLING A VENT SYSTEM IN AN OUTSIDE CHASE
A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a building. A chase is required for such venting.
1
/4" rise for every 12" of run towards the
Never run the vent pipe level or downward. This may cause excessive temperatures which could cause a fire.
WARNING
Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must follow all local building codes.
NOTICE
When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material. Maintain proper clearances to all combustible materials.
NOTICE
16 56D0106
VENT INSTALLATION
Inside Corner Detail FOR HORIZONTAL TERMINATION
Vent Terminal



Air Supply Inlet Area Where Terminals Not Permitted





Figure 12 - Horizontal Vent Termination Location
MINIMUM DISTANCES
A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305mm) minimum]. B = Clearance to window or door that may be opened [*1
2" (305mm) minimum].
C = Clearance to permanently closed window [*minimum 12" (305mm) recommended to prevent condensation on
window]
D
= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two (2) feet (610mm)
from the centerline of the terminal [18" (457mm) minimum].
E
= Clearance to unventilated soffits [12" (305mm) minimum]. Clearance to vinyl soffit [30" (762mm)].
F = Clearance to an outside corner. See page 12. G = Clearance to an inside corner. See page 12. H = *Not to be installed above a gas meter/regulator assembly within three (3) feet (914mm) horizontally from the centerline
of the regulator. I = Clearance to service regulator vent outlet [*3' (914mm) minimum]. J = Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [*12"
(305mm)minimum]. K = Clearance to a mechanical air supply inlet [*6' (1829mm) minimum].
= Clearance above a paved sidewalk or paved driveway located on public property [**7' (2133mm) minimum].
L M
= Clearance under veranda, porch, deck, or balcony [*12" (305mm) minimum
N = Clearance above a roof shall extend a minimum of 24" (610mm) above the highest point when it passes through the roof
surface and any other obstruction within a horizontal distance of 18" (457mm).
* As specified in CAN/CGA B149 Installation Codes. Note: Local codes or regulations may require different
clearances. ** A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single-family
dwellings and serves both dwellings. *** Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
***
].
Always maintain minimum clearances around vent systems. The minimum clearances to combustibles for horizontal vent pipe are 3" at the top and 1" at the sides and bottom of the vent system until the pipe penetrates the outside vertical wall (1" required). A 1" minimum clearance all around the pipe must be maintained. Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and
WARNING
may present a fire hazard.
56D0106 17
VENT INSTALLATION
TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE AND NONCOMBUSTIBLE EXTERIORS
 ..
"
/3+'( 02/(2
"
543+'( 02/(2
 ..
"
0.%534+%-( 
  0.%534+%-( ..
0/&0.%534+%-( ..
$-&0/9 7+4* 0 !+'( #$-- $-&0/9 7+4* (21(/'+&5-$2
0/&0.%534+%-(    ..    ..
"
!+'( #$--
Figure 13 - Allowable Venting Chart
HOW TO USE THE VENT GRAPH
The Vent Graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system.
1. Determine the height of the center of the horizontal vent pipe
exiting through the outer wall. Using this dimension on the Sidewall Vent Graph below, locate the point intersecting with the slanted graph line.
2. From the point of this intersection, draw a vertical line to the
bottom of the graph.
3. Select the indicated dimension, and position the fireplace in
accordance with same.
Example A: If the vertical dimension from the floor of the
fireplace is 11' (3.4m) the horizontal run to the face of the outer wall must not exceed 14' (4.3m).
Example B: If the vertical dimension from the floor of the
unit is 7' (2.14m), the horizontal run to the face of the outer wall must not exceed 8
Sidewall Vent Graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system.
1
/2' (2.6m).
"
 $8+.5. '(14* 0)  ..
)02 $-&06( -0&$4+0/
 +/+.5. 7+'4* )02 %$&, 7$-- 0)
$-&06( -0&$4+0/ 0.%534+%-(   .. 0/&0.%534+%-(   ..
  -($2$/&( )20. &02/(2 +/ $-&06(
-0&$4+0/ 0.%534+%-(   .. 0/&0.%534+%-(   ..
-&06( 0&$4+0/
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10
8 6 4 2
Horizontal Dimension From the Outside Face of the Wall
Dimensions in
Feet
eg: A
2 4 6 8 10 12 14 16 18 20
to the Back of the Fireplace
Vertical Dimension From the Floor of Unit to the Center of the
Horizontal Vent Pipe
Figure 14 - Rear Wall Venting Graph
18 56D0106
VENTING INSTALLATION
REAR WALL VENT INSTALLATION
When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance
• The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m). See
Figure 15.
• Only one 45° elbow is allowed in these installations.



Top View Flat Installation
Figure 15 - Rear Vent Application,
Maximum Horizontal Distance
1. Locate and cut the vent opening in the wall. For combustible walls first frame in opening. See Figure 16.





Combustible Walls: Cut a 91⁄2"H x 91⁄2" W
(241mm x 241mm) hole through the exterior wall and frame as shown. See Figure 16.


Noncombustible Walls: Hole opening should be
71⁄2" (190mm) in diameter.
2. Rigid vent pipes and fittings have special twist-lock
Figure 16 - Vent Opening Requirements
connections. Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor.
Twist-lock Procedure: The female ends of the
pipes and fittings have three locking lugs (indenta-
Locking Lugs
tions). These lugs will slide straight into matching slots on the male end of adjacent pipes and fittings. Push the pipe sections together and twist one sec­tion clockwise approximately one-quarter turn until the sections are fully locked. See Figure 17.
3. Attach vent pipe assembly to the fireplace. Set fireplace in front of its permanent location to insure minimum clearances. Mark the wall for a 9
1
2"H
Male Slots
x 91⁄2"W (241mm x 241mm) rectangle hole (for noncombustible material such as masonry block or concrete, a 71/2" [190mm] diameter hole is accept­able). See Figure 16. The center of the hole should line up with the center line of the horizontal rigid
Figure 17 - Rigid Vent Pipe Connections
vent pipe end. Be sure to allow for minimum rise. Cut a 9 noncombustible). Frame as necessary. Allow
1
/2"x91/2" (241mm X 241mm) rectangle hole through combustible exterior wall (71/2" [190mm] diameter hole if
1
/4" minimum rise per foot. See Figure 16.
Female
Note: Horizontal runs of vent must be supported every three feet (914mm). Use wall straps for this purpose.
56D0106 19
VENT INSTALLATION
REAR WALL VENT INSTALLATION (continued)
4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up. Insure proper clearance of 1" to combustibles is maintained. Attach the vent cap with four wood screws supplied. See Figure 18.
Do not recess vent termination into any wall. This will cause a fire hazard.
WARNING
NOTE: Replace the wood screws with appropriate fasteners for stucco, brick, concrete, or other types of siding.
Vent Cap
HOT
Wood Screw
Apply Mastic to
All Four Sides
Figure 18 - Installing Horizontal Vent Cap
Cut Vinyl Siding
Away to Fit Standoff
For vinyl siding, stucco, or wood exterior use vinyl siding standoffs between vent cap and exterior wall. The vinyl siding standoff prevents excessive heat from melting the vinyl siding material. Bolt the vent cap to the standoff. Apply non-harden ing mastic around outside edge of the standoff instead of the vent cap assembly. Use wood screws provided to attach the standoff. See Figure 19.
5. Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap. See Figure 20.
6. Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of
1
1
/4". Apply silicone to the outer pipe connection. Fasten
all vent connections with screws provided.
7. Slide the wall thimble against the interior wall surface and attach with srews. See Figure 20 .
For more information, follow instructions that comes with terminations.
NOTICE
-
Apply
Mastic to
All Four
Sides
Vent Cap
(Horizontal
Termination)
Standof #950
Simpson
Termination
#985
HOT
Nut
Bolt
Wood Screw
Figure 19 - Installing Simpson Vinyl Siding
Standoff and Termination
Interior Wall
Surface
Fire Stop
Assembly
20 56D0106
Screw
Horizontal
Vent Pipe
Figure 20 - Connecting Vent Cap with Horizontal Vent Pipe
VENT INSTALLATION
HORIZONTAL (THROUGH THE WALL) TERMINATION CONFIGURATIONS
Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the vari­ous dimensions allowable. See page 18.
Minimum clearance between vent pipes and combustible materials is 3" on top and 1" from bottom and sides unless otherwise noted (Exception: Outside wall with firestop: 1" all around pipes are allowed).
When vent termination exits through foundations less than 20" below siding outcrop, the vent pipe must flush up with the siding.
It is best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length.
The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace (or the top of the transition elbow) to the face of the outer wall or the mounting flange of the termination.
When installing the appliance as a rear vent unit, the 90° 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations, and unless specifically mentioned should be ignored when calculating venting layouts.
WARNING
• The maximum number of 90° elbows per side wall installation is three (3). See Figure 21.
• If a 90° elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 20" (508mm). See Figure 22.
3 x 90° Elbows
3 x 90° Elbows
20"
Max.
20"
Max.
Figure 21 - Maximum Three (3) 90° Elbows
Per Installation
56D0106 21
Figure 22 - Maximum Horizontal Run with No Rise
VENT INSTALLATION
HORIZONTAL (THROUGH THE WALL) TERMINATION CONFIGURATION
• If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36" (914 mm) (Fig. 21 A and B) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. See
Figure 24.
Example: According to the vent graph (page 17) the maximum horizontal vent length in a system with a 7.5' vertical rise is 20’ (6m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17' (5.2 m).
In Figures 23 and 24, Dimension A plus B must not be greater than 17' (5.2m).
• The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.
• For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (45cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.
• The maximum number of elbow degrees in a system is 270°.
See Figure 25.
A
10'
(Continued)
B
7'
90°
A
7'6"
Figure 23 - Horizontal Run Reduction
Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total Angular Variation = 270°
1
B
Horizontal 90° Elbow = 3' Reduction
7'6"
A + B = 17' Maximum
Figure 24 - Maximum Vent Run with Elbows
22 56D0106
2
3
4
1
2
3
4
1 + 2 + 3 + 4 = 270°
Figure 25 - Maximum Elbow Usage
VENT INSTALLATION
BELOW GRADE INSTALLATIONS
When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.
Ensure that sidewall venting clearances are observed. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termination area.
If installing a snorkel, a minimum 24" vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36". This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24".
1. Establish vent hole through the wall.
2. Remove soil to a depth of approximately 16" below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 12" of coarse gravel leaving a clearance of approximately 4" below snorkel. See Figure 26.
3. Install vent system.
4. Ensure a watertight seal is made around the vent pipe coming through the wall.
5. Apply high temperature sealant caulking (supplied) around the 4" and 7" snorkel collars.
6. Slide the snorkel into the vent pipes and secure to the wall.
7. Level the soil so as to maintain a 4" clearance below snorkel.
See Figure 17, page 19.
See Figure 26.
• Do not back fill around snorkel.
• A clearance of at least 4" must be maintained between the snorkel and the soil.
WARNING
If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8x1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. See Figure 27.
Screws
Firestop
24"
Minimum
Foundation Wall
Figure 26 - Below Grade Installation
56D0106 23
Minimum
4" Clearance
Ground
Window Well
Gravel
Drain
Foundation
Recess
Watertight Seal
Around Pipe
Figure 27 - Snorkel Installation,
Recessed Foundation
Snorkel
Wall Screws
Sheet Metal
Screws
VENT INSTALLATION
VERTICAL THROUGH-THE-ROOF APPLICATIONS
A restrictor disc must be installed on any vertical termination that is higher than 12'.
NOTICE
Install restrictor disc into 4" fireplace collar or first vent sections. See Figure 28.
Restrictor
Disc
Stove Collar
Figure 28 - Installing Restrictor Disc into Stove Collar
24 56D0106
VERTICAL THROUGH-THE-ROOF APPLICATIONS (continued)
This Gas Fireplace has been approved for,
• Vertical installations up to 40' (12m) in height. Up to a 10' (3m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. See Figure 29.
40' Maximum Height
8' Minimum Height
10'
Maximum
Support Straps
Every 3'
40' Maximum Height
8' Minimum Height
VENT INSTALLATION
Support
10'
Maximum
Support Straps
Every 3'
Straps
Every
5'Vertical
Figure 29 - Support Straps for Horizontal Runs
• Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18" (450mm).
Example: Maximum horizontal length
No elbows = 10’ (3m)
1x45° elbows = 8.5’ (2.6m)
2x45° elbows = 7’ (2.1m)
• A minimum of an 8' (2.5m) vertical rise is required.
• Two sets of 45°elbows offsets may be used within the vertical sections. From 0 to a maximum of 8' (2.5 m) of vent pipe can be used between elbows.
See Figure 30.
• Determine the roof pitch and use the appropriate starter kit for offset installation.
• The maximum angular variation allowed in the system is 270°. See Figure 30.
1
2
3
4
Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total Angular Variation = 270°
1
2
3
4
• The minimum height of the vent above the high­est point of penetration through the roof is 2' (610mm).
56D0106 25
Figure 30 - Maximum elbow Usage
VENT INSTALLATION
INSTALLATION FOR VERTICAL TERMINATION
1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. See Figure 31 to avoid cutting load bearing members.
Roof
Flashing
NOTE: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. Offsets must fall within the parameters shows in Figure 14, page 18.
2. Set fireplace in desired location. Drop a line plumb down from the ceiling to the position of the flue exit. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole a this point.
Drop a plumb line from the inside of the roof to the ceiling locat-
ing hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.
FLAT CEILING INSTALLATION
1. Cut a 9
1
/2" (241mm) square hole in the ceiling using the locat-
ing hole as a center point The opening should be framed to
1
9
/2"x91/2" (241mm x 241mm) inside dimensions as shown in Figure 32 using framing lumber the same size as the ceiling joist. If the area above the ceiling is an insulated ceiling or a room, nail firestop from the top side. This prevents loose insulation from fall­ing into the required clearance space. See Figure 32. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side. See Figure 33.
Wall
Strap
45° Elbows
Ceiling Firstop
Figure 31 - Offset with Wall Strap and 45°
Elbows
Nails
Firestop
2. Assemble the desired lengths of pipe and elbows necessary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked. See Figure
17, page 19.
3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof).
1
/2"x9
1/
2
" (241mm x 241mm) hole must be measured on the
The 9 horizontal. Actual length may be larger depending on the pitch of the roof. There must be a 1" minimum clearance from the vent pipe to combustible materials. (Insulation should be considered a combustible material) Frame the opening as shown in Figure
16 on page 19.
26 56D0106
Figure 32 - If area above is a room, install
firestop above framed hole as shown
Firestop
Nails
Figure 33 - If area above is not a room, install
firestop below framed hole as shown
Continued on next page
VENT INSTALLATION
INSTALLATION FOR VERTICAL TERMINATION (CONTINUED)
4. Connect a section of pipe and extend up through the hole.
NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose. See Figure 31, page 26. Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.
5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing. There must be a 1" clearance from the vent pipe to combustible materials.
6. Continue to add pipe sections until the height of the vent cap meets the minimum requirements below.
NOTE: You must increase vent height for steep roof pitches. Nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem.
NOTE: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure to meet the minimum allowable clearances to combustibles. Do not fill any of the required clearance spaces with insulation.
H
X
12"
Figure 34 - Minimum Chimney Clearance
TERMINATION HEIGHT TABLE
Use this table to determine the minimum height above the roof.
Minimum Height
Roof Pitch Feet Meters
Flat to 7/12 1 0.3 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4 1.22 Over 12/12 to 14/12 5 1.52
56D0106 27
FIREPLACE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type.
INSTALLING GAS PIPING TO FIREPLACE LOCATION
INSTALLATION ITEMS NEEDED
Before installing fireplace and burner system, make sure you have the items listed below.
• External regulator (supplied by installer) • Tee joint
• Piping (check local codes) • Pipe wrench
• Sealant (resistant to propane/LP gas)
• Test gauge connection*
• Sediment trap (optional but recomended)
A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
WARNING
For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires
• approved flexible gas line with gas connector (if allowed by local codes — not provided)
* A CSA design-certified equipment shutoff valve with
NPT tap is an acceptable alternative to test gauge connec­tion. Purchase the CSA design-certified equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 35. Pointing the vent down protects it from freezing rain or sleet.
External
Regulator
100 gal. (min)
Propane/LP Supply Tank
1
/8"
an external regulator (not supplied). Install the external regulator between
CAUTION
the burner system and propane/LP supply.
Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide
CAUTION
minimum inlet pressure (listed on data
Vent
Pointing
Down
plate) at the maximum flow rate (BTU/ hr). Undue pressure loss will occur if the pipe is too small.
Figure 35 - External Regulator with Vent Pointing
Down (Propane/LP Only)
When using copper or flex connectors use only fittings approved for gas connections. The gas control inlet is
3
/8" NPT.
28 56D0106
External regulators may be necessary for natural gas. One- or two-pound systems will damage this appliance and may cause fire hazzard.
WARNING
FIREPLACE INSTALLATION
Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
A manual shutoff valve must be installed upstream of the appliance.
1
Union tee and plugged
/8 " NPT
pressure tapping point should be
WARNING
NOTE : The gas line connection may be made using some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-B149 (1 or
2) Installation Code.
A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 36.
IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.
1
/2" rigid tubing or an approved flex connector. Since
installed upstream of the appliance.
CAUTION
See Figure 35.
Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
CAUTION
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 36. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.
Approved Flexible
Gas Line
Sediment Trap/Drip Leg
UL/CSA Design-Certified Equipment
Shutoff Valve with
Tee Joint Pipe Nipple Cap
1
 
/8" NPT Tap*
Natural Gas
From Gas Meter
(5" W.C. to 10.5" W.C. Pressure)
Propane/LP
From External Regulator
(11" W.C. to 13" W.C. Pressure)
56D0106 29
Figure 36 - Gas Connection
CHECKING GAS PRESSURE
1. Check gas type. The gas supply must be the same as stated on the applianceʼs rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.
2. To ease installation, a 30" (mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach
3. After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/40 water and soap or a gas sniffer.
4. To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.
5. To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. See Figure 37. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.
1
/2" gas line onto shut-off valve.
Pressure
Test “IN”
Pressure
Test “OUT”
HI/LO
Knob
Pilot Adjustment
Screw
Figure 37 - Gas Pressure Check at Gas Valve
Do not use open flame to check for gas leaks.
WARNING
30 56D0106
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
WARNING
70 (latest edition) and Canadian Electrical Code, CSA C22.1.
Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.
CAUTION
Verify proper operation after servicing.
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc­tion box at the desired location on the wall. See Figure 38. Do not extend beyond the wall switch wire length provided.
NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.
OPTIONAL REMOTE
WALL SWITCH
ON
PILOT
HI
ON
OFF
O
L
TH TP
TH/TP
ON
OFF
RS
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
Do not connect wall switch
Figure 38 - Wiring Diagram for Wall Switch
to AC (110V) circuit.
WARNING
56D0106 31
ELECTRICAL INSTALLATION
ELECTRONIC PILOT IGNITION WIRING
Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or destroyed.
WARNING
Figure 39 - Electronic Ignition System Wiring Diagram
REMOTE WALL SWITCH
Position the wall switch. Do not extend beyond the 15 feet of wire.
OPTIONAL DC REMOTE SYSTEMS
These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with the remote.
1. Plug in remote connector wire to remote receiver.
2. Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. Figure 39.
3. Mount remote control receiver at junction box (for your wall switch).
32 56D0106
See
1. Unhook top filigree. Set aside. See Figure 40.
2. Remove canopy from top of unit.
3. Attach canopy to underside of top outer shell with there (3) screws provided. See Figure 41.
3. Reinstall filigree.
Filigree
CANOPY INSTALLATION
Canopy
Screws
Figure 40 - Removing Filigree
Figure 41 - Installing Canopy
56D0106 33
GLASS REMOVAL
GLASS FRAME REMOVAL
1. Remove filigree from the top.
2. Release two clamps on bottom of fireplace. See Figure 42.
3. Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace.
4. Set glass frame aside.
Glass Frame
Clamps
Three
Tabs
Figure 42 - Removing Glass Frame
Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear.
CAUTION
34 56D0106
ROCK WOOL PLACEMENT
1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a nickel or smaller.
2. Place the logs on the burner. See Log Placement page 37.
3. Distribute one layer of rock wool to cover all burner ports. Fill front gap between grate and burner. See Figure 43.
4. Light unit and after 15 minutes, check burner flame and glow. See Burner Flame, page 36.
If the flame is blue and only in the center, turn off unit and let cool. After unit cools, remove logs. If the back holes are clear, add more rock wool to the center of the burner. Replace logs and check flame again. Save left over rock wool to refresh when cleaning later. Too much rock wool can disturb the flame and cause sooting on the glass or logs.
Do not use the entire bag of rock wool to cover the burner. This could cause the flame to burn poorly and may lead to sooting.
WARNING
Do not sprinkle the lava rock or ember chunks on top of the burner. This may cause potential sooting, glass breakage and a fire hazard.
WARNING
LAVA ROCK AND EMBERS PLACEMENT
Sprinkle lava rock on the floor of the inner combustion chamber. Evenly distribute the rock. Do not pile the lava rock up in front of grate. Do not place lava rock on the burner. If desired, purchase optional embers to decorate the floor of the fireplace.
Burner
Cover with
Rock Wool
Figure 43 - Placement of Rock Wool on Burner
56D0106 35
ANDIRON INSTALLATION
1. Remove two (2) brackets and two (2) bolts from package.
2. Attach bracket to back of each andiron with bolts provided. See Figure 44.
3. Line up the rectangle hold on bracket with grate bar. See Figure 45.
4. Push bracket down until it snaps into place.
Andiron
Rectangle Hole
in Bracket
Grate Bar
Bolt
Andiron
Bracket
Figure 44 - Installing Andiron
Figure 45 - Installing Andiron
Burner
36 56D0106
LOG PLACEMENT
1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins at the back of the plate. See Figure 46.
2. Place bottom right log (#2) on grate. Log should rest firmly on two right mounting pins of plate. See Figure 47.
3. Place bottom left log (#3) on grate. Log should rest firmly on two left mounting pins of plate. See Figure 48.
Bottom Right Log (#2)
Mounting Pins
on Back of
Plate
Rear Log (#1)
Figure 46 - Installing Rear Log (#1)
Right Mounting
Pins
Figure 47 - Installing Bottom Right Log (#2)
Bottom Left Log #3
Left Mounting
Pins
56D0106 37
Figure 48 - Installing Bottom Left Log (#3)
LOG PLACEMENT
4. Line up the indention on bottom of right top log (#4) with protrusion on top of right bottom log. See Figure 49.
5. Line up the indention on bottom of top left log (#5) with the protrusion on top of bottom left log. See Figure 50.
6. Logs should all be properly installed as in Figure 51.
Top Left Log (#5)
Protrusion
Right Top
Log (#4)
Protrusion
Figure 49 - Installing Right Top Log (#4)
Figure 50 - Installing Right Top Log (#5)
38 56D0106
Figure 51 - View of All Logs Properly Installed
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
WARNING
A. This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these
instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Turn off all gas to the appliance.
• Open windows.
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service tech-
nician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
LIGHTING PILOT FOR THE FIRST TIME
INITIAL LIGHTING
Purge air from the supply line as follows:
Open main shutoff valve.
Unscrew main pressure test point.
Leave inlet test screw open until gas comes in.
When gas is flowing, tighten inlet screw immediately.
LEAK TESTING
1. Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture.
2. Next check for gas leaks at the burner with soap and water mixture.
Never use an open flame to check for gas leak.
WARNING
3. Check the pilot for gas leaks with soap and water mixture.
56D0106 39
OPERATING INSTRUCTIONS
LIGHTING PILOT FOR THE FIRST TIME
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
Never check for gas leak with open flame!
DANGER
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.
WARNING
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
• Burner connections • Field made joints / gas shutoff valve
• Pilot • Factory made joints
• Each joint or connection • All joints on valve and control body
LIGHTING PILOT
The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools
WARNING
during this operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise to pilot position.
2. Depress fully and hold pilot gas knob. The elec­tronic ignitor will automatically ignite the pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.
40 56D0106
Figure 52 - Pilot Position
Continued on next page
OPERATING INSTRUCTIONS
LIGHTING BURNER
MAIN BURNER SWITCH
The “ON/OFF” switch for the main burner can be found behind door of the fire place. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. See Figure 53.
LIGHTING THE BURNER
Depress and turn the knob counterclockwise Figure 54. It will take less than four (4) seconds for the burner to ignite.
PILOT POSITION
Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. See Figure 55.
to the “ON” position. See

-
Figure 53 -
On/Off/RS Switch

Figure 54 - On Position
50
Depress and turn knob clockwise
Figure 55 - Pilot Position
TO TURN OFF GAS
to “OFF” position. See Figure 56.

Figure 67 - Off Position
56D0106 41
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance is equipped with an ignition device
(Piezo) which automatically lights the pilot. Do NOT try to light the burner by hand.
B. BEFORE OPERATING smell all around the appli-
ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Turn off all gas to the appliance.
• Open windows.
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. Turn off all electric power to appliance.
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
WARNING
WARNING
Never use an open flame to check for gas leak.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service tech-
nician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
LIGHTING ELECTRONIC IGN
1. STOP! Read the safety information above.
2. Set thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which auto matically lights the burner. Do not try to light the burner by hand.
5. Wait 5 minutes to clear out any gas. Then smell for gas, includ ing near the floor. If you smell gas STOP! Follow “B” — What to Do if You Smell Gas above. If you do not smell gas, go to the next step.
6. Turn on all electric power to appliance.
7. Set thermostat to desired setting.
8. Turn RS-OFF-ON rocker switch to “ON”.
9. If the appliance will not operate, follow the instruction
To Turn Off Gas below and call your service techni-
cian or gas supplier.
-


-
Figure 57 - Electronic Gas Valve



1. Open lower door.
2. Turn RS-OFF_ON rocker switch to “OFF”.
3. Turn off all electric power to the appliance if service is to be performed.
4. Close lower door.
42 56D0106
TO TURN OFF GAS
CLEANING AND MAINTENANCE
Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season
WARNING
BURNER, PILOT AND CONTROL COMPARTMENT
Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
PILOT FLAME
The flames from the pilot should be visually checked as soon as the heater is installed and periodically during normal operation. The pilot flame must always be present when the fireplace is in operation. See Figure 58. The pilot flame has three distinct flames, one engulfing the thermopile, one engulfing the ther­mocouple, and the other reaching to the main burner..
BURNER
Inspect area around the injector. Remove any lint or foreign material with a brush or vacuum.
BURNER FLAME
Thermocouple
Thermopile
Figure 58 - Pilot Flame
The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow and slightly taller than the rear log. See
Figure 59.
If the flame is blue and only in the center, turn off unit and let cool. After unit is cool, remove logs and check to make sure the back holes in the burner are not covered with rock wool. If the back holes are clear, add more rock wool to the center of the burner. Replace logs.
NOTE: The type of installation, vent system configuration, and wind effects may cause the flame patterns to vary.
Figure 59 - Burner Flame Appearance
56D0106 43
CLEANING AND MAINTENANCE
VENT SYSTEM
The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function.
GLASS DOOR
Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.
When cleaning the glass, remember:
Do not remove the glass when hot. Allow glass to cool before removal.
NEVER use abrasive materials.
Keep children and pets a safe distance away.
Never operate the fireplace without the glass door properly secured.
Never operate the fireplace if the glass is broken.
Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace manufacturer –
Handle glass door with care to avoid striking or scratching it on hard objects.
No substitute materials may be used.
To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive, mild-cleaning solution. Simply apply an adequate amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door.
LOGS
Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, see “Log Placement” found in the Final Installation section.
NOTE: Do not use cleaning fluid to clean logs.
ROCK WOOL
Replace or add rock wool as required following installation instructions in the Final Installation section of this manual.
44 56D0106
VENT COMPONENTS
1

ILLUSTRATED PARTS LIST
4
7
3
9
8
5
11
2
6
Simpson Duravent or
10
Qty/
Item
Box Description
1 1 Simpson Horizontal High Wind Termination Cap 985
1 1 Horizontal Termination Cap with Built-In Vinyl Siding Standoff, Heat Deflector,
Firestop and Adjustable Pipe 7" to 11" BHRTK
1 1 Horizontal Termination Cap Built-In Vinyl Siding Standoff, Heat Deflector,
Firestop, 90° Elbow and Adjustable Pipe 7" to 11" BHSTK
1 1 Horizontal Termination Cap with Built-In Vinyl Siding Standoff, Heat Deflector,
Firestop and Flexible Pipe 24" to 48" BHSFTK
2 1 Vertical Termination Cap with Flashing, Storm Collar and Firestop BVTK
2 1 Vertical Termination 980
3 6 6” Pipe Length 908
3 6 9” Pipe Length 907
3 6 12” Pipe Length 906
3 6 24” Pipe Length 904
3 6 36” Pipe Length 903
3 6 48” Pipe Length 902
4 6 11” To 14 5/8” Pipe, Adjustable 911
4 6 17” To 24” Pipe, Adjustable 917
5 6 45° Elbow 945
5 6 45° Swivel Elbow 945G
6 6 90° Elbow 990
6 6 90° Swivel Elbow 990G
7 6 Flashing, 0/12 To 6/12 Roof Pitch 943
8 6 Storm Collar 953
9 6 Firestop 963
10 1 Vinyl Siding Standoff 950
11
1 Deflector Shield 37D0115 (Monessen)
Other Approved Venting Components P/N
56D0106 45
ILLUSTRATED PARTS LISTS
FIREBOX COMPONENTS
4
8
5
3
6
7
9
1
2
11
10
46 56D0106
ILLUSTRATED PARTS LISTS
FIREBOX COMPONENTS
Item Description Qty SDV500 SDV600
Standard Features
Junction Box Assembly
1
Filigree Black
2
Glass Frame Assembly
3
Canopy
4
Factory Installed Options
Firebox Floor
5
Standard Firebrick Center
6
Standard Firebrick Right
7
Standard Firebrick Left
8
Blower Motor
9
Thermostat Sensor
10
Accessories/Field Installed Options
6,7,8 Weathered Firebrick Walls
11 T-stat Blower with Speed Control
1 2 1 1
1 1 1 1 1 1
1 1
26D2128K 26D2128K
56D0192 56D0672
56D0108 56D0608
56D0277 56D0697
56D0014 56D0014
56D0013 56D0013
56D0012 56D0012
56D0011 56D0011
26D0748 26D0748
26D2870 26D2870
FBS500W8B FBS600W8B
BLOT BLOT
LOGS
Item Description Qty SDV500 SDV600
1 Rear Log 1 56D0002 56D0002
2 Bottom Right Log 1 56D0004 56D0004
3 Bottom Left Log 1 56D0003 56D0003
4 Top Right Log 1 56D0006 56D0006
5 Top Left Log 1 56D0005 56D0005
3
1
4
2
5
56D0106 47
ILLUSTRATED PARTS LISTS
ADDITIONAL ACCESSORIES
4
3
2
1
5
48 56D0106
6
ILLUSTRATED PARTS LISTS
ADDITIONAL ACCESSORIES/FIELD INSTALLED OPTIONS AVAILABLE
Item Description Qty SDV500 SDV600
1
Metal Trim - Brass
1
Metal Trim - Pewter
1
Metal Trim - Black
2
Curved Design - Black
2
Curved Design - Brass
2
Curved Design - Pewter
33Filigree - Gold
Filigree - Pewter
4
Arched Screen Frame - Black
4
Arched Screen Frame - Gold
4
Arched Screen Frame - Brushed Pewter
5
Cabinet Door Frame - Black
5
Cabinet Door Frame - Gold
5
Cabinet Door Frame - Brushed Pewter
5
Cabinet Door with Screen - Black
5
Cabinet Door with Screen - Gold
5
Cabinet door with Screen - Brushed Pewter
6
Arched Front with Lower Control Door - Black
6
Arched Front with Lower Control Door - Gold
6
Arched Front with Lower Control Door - Brushed Pewter
Accessories/Field Installed Options Available but Not Shown
Oak Wall Surround with Honey Oak Finish Birch Surround with Dark Cherry Finish Oak Hearth with Honey Oak Finish Birch Hearth with Dark Cherry Finish
1 1 1
1 1 1
1 1
1 1 1
1 1 1 1 1 1
1 1 1
1 1 1 1
BRMTK36
BLMTK36
PWMTK36
BLMTK36
BRMTK36
PWMTK36
D36FPG
D36FPP
SDV500ASFB SDV500ASFG SDV500ASFP
SDV500CDFB
SDV500CDFG
SDV500CDFP
SDV500CDB SDV500CDG SDV500CDP
SDV500AFB SDV500AFG SDV500AFP
WS500F-O WS500F-C
WH500F-O
WH500F-C
BRMTK42
PWMTK42
BLMTK42
BLMTK42
BRMTK42
PWMTK42
D42FPG D42FPP
SDV600ASFB SDV600ASFG SDV600ASFP
SDV600CDFB SDV600CDFG SDV600CDFP
SDV600CDB SDV600CDG SDV600CDP
SDV600AFB
SDV600AFG
SDV500AFP
56D0106 49
ILLUSTRATED PARTS LISTS
STANDING PILOT — MILLIVOLT CONTROL
1
2C
2I
2T
2
5
6
3
4
7
10
8
9
11,12, 13, 14, 15, 16
50 56D0106
ILLUSTRATED PARTS LISTS
STANDING PILOT – MILLIVOLT CONTROL
Item Description Qty SDV500NV SDV500PV SDV600NV SDV600PV
1 Gas Valve Assembly 1 37D0117 37D0118 37D0117 37D0118
2
Pilot Assembly
2C
Replacement Thermocouple
2I
Replacement Igniter and Wire
2T
Replacement Thermopile
3 Burner Tube 1 54D0194 54D0194 54D0194 54D0194
4 Flexhose with Shutoff Valve 1 23D6046 23D6046 23D6046 23D6046
5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048
6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503
7 Injector 1 56D0114 56D0113 56D0614 62D3003
8 Burner Assembly 1 54D0378 54D0378 54D0378 54D0378
9 Venturi 1 45D0600 45D0600 45D0600 45D0600
10 Wire Assembly 1 44D0500 44D0500 44D0500 44D0500
10 Wire Assembly 1 44D0501 44D0501 44D0501 44D0501
Accessories
11 Thermostatic Remote Control 1 RCT/TRC RCT/TRC RCT/TRC RCT/TRC
12 Remote Control On/Off 1 RCM/MRC RCM/MRC RCM/MRC RCM/MRC
13 Remote Control Basic 1 RCB/RCBE RCB/RCBE RCB/RCBE RCB/RCBE
14 Wireless Wall Thermostat 1 WWTD/WWTA WWTD/WWTA WWTD/WWTA WWTD/WWTA
15 Wall Switch Kit 1 MVWS MVWS MVWS MVWS
16 Wall Thermostat Kit 1 MVWTS MVWTS MVWTS MVWTS
Conversion Kit (Not Shown)
500 Conversion NG to LPG 500 Conversion LPG to NG
600 ConversionNG to LP 600 Conversion LP to NG
1 1 1 1
1 1 1 1
37D0018 37D1067 37D1069 37D1068
SCK500CKP
— — —
37D0019 37D1067 37D1069 37D1068
SCK500CKN
— —
37D0018 37D1067 37D1069 37D1068
— —
SCK500CKP
37D0019 37D1067 37D1069 37D1068
— — —
SCK500CKN
56D0106 51
ILLUSTRATED PARTS LISTS
ELECTRONIC IGNITION
1
LO
HI
3
2
5
4
6
8
7
10
11
9
52 56D0106
ILLUSTRATED PARTS LISTS
5
5
00
37D0
325
37D0
325
ELECTRONIC IGNITION
Item Description Qty SDV500 SDV600
1 Gas Valve Assembly 1 37D0016 37D0017
2 Pilot Assembly 1 37D0020 37D0021
3 Burner Tube 1 54D0288 54D0288
4 Flexhose with Shutoff Valve 1 23D6046 23D6046
5 Rocker Switch 1 41D0048 41D0048
6 Injector 1 56D0113/114 56D0614/62D3003
7 Burner Assembly 1 56D0136 56D0136
8 Venturi 1 45D0059 45D0059
9 Wire Assembly 1 54D2007 54D2007
10 Ignition Module 1 37D0325 37D0325
11 Transformer 1 37D0027 37D0027
4D2007
4D2
56D0106 53
TROUBLESHOOTING
STANDING PILOT IGNITION
SYMPTOM POSSIBLE CAUSE ACTION
1. Spark ignitor will not light pilot after repeated trig­gering of piezo.
2. Pilot will not stay lit after carefully fol­lowing light­ing instruc­tions.
3. Pilot burning, valve knob turned to “ON”, switch is turned to “ON” or “RS”, but burner will not ignite.
4. Frequent pilot outage prob­lem.
A. Wire disconnected.
B. Defective ignitor.
C. No gas or low gas pressure.
D. No Propane/LPG in tank
A. Defective thermocouple
B. Defective valve
A. Defective switch, wall switch,
remote control or wire
B. Pilot flame too small
C. Defective or malfunctioning ther-
mopile
D. Defective valve
A. Pilot flame may be too high or too
low, causing pilot safety to drop out
A. Open door and check to make sure wire is connected to ignitor. B. Check for spark at electrode and pilot. If no spark and electrode
wire is properly connected, replace pilot assembly.
C. Check remote/manual shut off valve from fireplace. Low pressure
can be caused by bent lines, restricted lines, low pressure line pressure. Consult with plumber or gas supplier.
D. Check Propane/LPG tank. Refill tank.
A. Check that thermocouple flame impinges on thermocouple. Clean
and/or adjust pilot for maximum flame impingement. Ensure that the thermocouple connection at the gas valve is fully inserted and tight.
Disconnect the thermocouple from the valve, place one millivolt
lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 mV, replace pilot assembly.
B. If thermocouple is producing more than 15 mV, replace faulty
valve.
A. Check switch and wire for proper connection. Place jumper wires
across terminals of switch. If burner comes on, replace defective switch.If the switch is OK, repeat the same procedure on remote control If burner comes on, replace remote control.
Place jumper wire across wire at gas valves (terminals marked TH
and TP/TH). If burner comes on, wires are faulty or connections are bad. Replace wire.
B. If pilot flame is not close enough to the thermopile, adjust pilot
flame.
C. Check thermopile wire connections to make sure all are tight and
that the thermopile is fully inserted into pilot assembly. Check thermopile with a millivolt meter. Connect leads to TP and TP/TH terminals on the control valve. If meter reading is below 325 mV, replace pilot assembly.
D. Turn valve knob to “On” and switch to “ON.” Take a reading at
the thermopile leads (TP & TP/TH) on the valve. If the meter reads greater than 175 mV and the burner does not light, replace defective valve.
A. Clean and adjust the pilot flame for maximum flame impingement
on thermocouple.
5. The pilot and main burner extinguish while in oper­ation
54 56D0106
A. Inner vent pipe leaking exhaust
gases back into system
B. Horizontal vent improperly pitched
C. Improper vent cap installation
A. Check for flue product leak. Replace defective pipe section.
B. Check horizontal-venting piping is running upward 1/4" per foot.
Do not run the pipe level or downward.
C. Check for proper installation and freedom from debris or blockage
ELECTRONIC IGNITION
Modul
Module
START
TROUBLESHOOTING
1. Turn gas supply off.
2. Turn ON/OFF switch to “ON” Power to module (24V Normal)
YES
Is there a spark across
ignitor sensor gap?
YES
Turn on gas.
Does pilot burner light?
YES
NO
NO
NO
Check: Line voltage (120VAC) Low voltage transformer (19.5 minimum VAC) ON/OFF switch Wiring connections
Unplug ignition lead and check spark at module (24VAC normal).
Is spark OK?
YES
A. Check ignition cable ground wiring, ceramic insulator and gap.
Correct if necessary.
B. Does ignition cable show signs of melting or buckling?
Take protective action to shield cable and boot from excessive temperatures.
A. Are all manual gas valves open? Are supply tubing and pressure good? Are pilot burner orifies blocked? B. Check electrical connections between module and pilot
operator on gas control. C. Check for 24VAC across PV-MVPV terminals. If voltage is correct, replace gas control.
If voltage is not correct, replace module.
NO Replace module
Does spark stop when pilot is lit?
YES
Does main burner light?
YES
Does system run until ON/OFF switch
is in “OFF” position?
YES
END OF TROUBLESHOOTING
NO
NO
NO
NOTE: If Module goes into lockout, reset system.
A. Check continuity of ignition cable and ground wire. B. Clean flame rod. C. Check electrical connections between flame rod and module. D. Is ceramic flame rod insulator cracked? E. Is pilot flame a steady blue? Does flame cover flame rod? If not, adjust pilot flame. Replace module if problem persists.
A. Check for 24VAC across MV-MVPV terminal. Replace module if there is no voltage. B. Are electrical connections between module and gas
control good?
If connections are good, replace gas control or gas
control operator.
NOTE: If Module goes into lockout, reset system.
A. Check continuity of ignition cable and ground wire.
NOTE: If ground is poor or erratic, shutdown may
occasionally occur even though operation is normal at
time of checkout.
B. Is pilot flame a steady blue? Does flame cover flame rod?
If above checks out, replace module.
e
56D0106 55
TROUBLESHOOTING
GENERAL TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE ACTION
1. Glass Soots A. Flame impingement on logs A. Install log set per the instructions Inspect the injector and air intake area. Make sure this area does
not have any blockage from debris and clean.
Check gas supply.
2. Flame burn
blue and lifts off burner (ghosting)
A. Insufficient oxygen being supplied A. Ensure that the vent cap is installed properly and free of debris.
Ensure that the vent system joints are tight and have no leaks. Ensure that no debris has been blocking the inner air intake at the bottom back of the combustion chamber. Ensure that the glass is properly secure and latch.
56 56D0106
NOTES
56D0106 57
MASSACHUSETTS RESIDENTS ONLY:
PLEASE READ AND FOLLOW THESE
SPECIAL REQUIREMENTS
NOTE REGARDING VENTED PRODUCTS
This product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachusetts.
Any residence with a direct vent product must have a CO detector installed in the residence.
Installation of the fi replace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have a T shutoff valve.
NOTE REGARDING VENT FREE PRODUCTS
This product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachusetts.
In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have a T shutoff valve.
CARBON MONOXIDE DETECTOR REQUIREMENTS
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure
used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above fi nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfi ed:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall hori­zontal vented gas fueled equipment, the installing plumber or gasfi tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the fl oor level where the gas equipment is to be installed. In addition, the installing plumber or gasfi tter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualifi ed licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space
or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent fl oor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of
installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detec­tor with an alarm shall be installed.
SPECIAL REQUIREMENTS CONTINUED
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accor­dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certi­fi ed.
3. SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the build­ing at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUC-
TIONS.”
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detec­tors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manu-
facturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the
manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi es “special venting systems,” the following requirements shall be satisfi ed by the manufacturer:
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
LIMITED LIFETIME WARRANTY POLICY
LIFETIME WARRANTY
The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners.
FIVE YEAR WARRANTY
The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
BASIC WARRANTY
Monessen Hearth Systems (MHS) warrants the components and materials in your gas appliance to be free from manufac­turing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by MHS in the appliance are found to be defective in materials or workmanship, (MHS) will, at its option, replace or repair the defective components at no charge to the original owner. MHS will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.
This Limited Lifetime Warranty will be void if the appliance in not installed by a qualified installer in accordance with the installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damage by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation thereof by unquali­fied installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) incidental or consequential damage. All service work must be performed by an authorized service representative.
This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. MHS does not assume for it any other obligations or liabilities in con­nection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have additional rights not covered in the Limited Lifetime Warranty.
MHS reserves the right to investigate any and all the claims against the Limited Lifetime Warranty and decide upon method of settlement.
For information about this warranty, contact:
Technical Services
Monessen Hearth Systems
149 Cleveland Drive
Paris, Kentucky 40361
Aug. 2006 P/N 56D0106 • Rev. 7