Monessen Hearth MONAL Installation Instructions Manual

Page 1
Dual Overhead Accent Light Installation Instructions
Model: MONAL
For use with LCUF Series Firebox
WARNING: Turn appliance OFF and allow to cool before servicing. Only a qualied service
person should service and repair this insert. A qualied service person must connect and disconnect the insert to/from the gas supply. Follow all local codes.
NOTE: This kit is designed to work manually with the dim­mer control supplied.
BEFORE YOU BEGIN
The instruction sheet is ONLY for models listed below; carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately contact the dealer from whom you purchased this kit.
This kit is designed for use with the LCUF32CR-B,
LCUF36CR-B, LCUF42CR-B reboxes.
KIT CONTENTS:
Two (2) light socket assemblies
One (1) Rheostat dimmer
One (1) 6 ft. power cord
One (1) light join wire harness
Two (2) light bulbs (35 watt)
Two (2) light covers with clear lens
One (1) fastener pack
TOOL REQUIRED:
Phillips head screwdriver or battery drill
WARNING
IMPORTANT: Always check local building codes.
This installation must comply with local regulations as well as the National Electric Code.
Installation Instructions - Wiring
1. Before installing the lighting kit, wire the junction box into an electrical circuit. This should be done before
framing the replace. Wire with minimum 60°C wire in
accordance with prevailing codes.
2. Remove the two (2) screws for the junction box cover,
loosen romex connector and slide up wire. Connect wires to junction box wires securely. Slide junction box cover down to unit and reattach to rebox and tighten romex connector to wire. Junction box was installed at
the factory. See Figure 1.
120V AC 60Hz
Electrical Grounding Instructions: This appliance is equipped with a three­prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle.
Electrical connections should only be
performed by a qualied licensed electrician. Main power supply must be turned off
before connecting kit.
CAUTION
Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18
Factory Supplied
Junction Box
Figure 1 - Junction Box Wiring Diagram
Not Supplied
Page 2
Installation Instructions - Light Kit
1. Remove burner and log set from rebox if previously installed.
2. Remove rebrick if previously installed.
3. Remove both side access panels and rear access pan­el. See Figure 2.
Rear Access Panel
Side Access Panel
Figure 4 - Rheostat Dimmer
7. Attach wires from light sockets from each side into the light join harness. Two (2) male spades from each light socket should attach into the paired female spades of the light join harness. See wiring diagram Figure 5.
Figure 2 - Access Panels
4. Remove bulb delete plates on left and right side at front
of rebox. See Figure 3.
Bulb Delete Plates
Figure 3 - Bulb Delete Plates
5. Insert wire from light socket through opening from bulb
delete and direct toward side of rebox. As wire drops
to side, it should become visible through the side ac­cess panel, seat bulb socket into opening. Attach with two (2) screws removed from bulb delete plate. Repeat steps for opposite side.
6. Remove knob from rheostat dimmer, using two (2) screws from fastener pack, attach dimmer to side ac­cess panel. See Figure 4.
Light Box
Tan
Tan Black
Dimmer Control
White
Black
Black
White
Black
Figure 5 - Wiring Diagram
Light Box
Tan
Tan
6ft. Power Cord
Note: Images of light box may not be
representative of your model.
Junction Box
Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18
Page 3
8. When routing wires, lift the blower base through the rear access panel and route all wires under the blower base.
9. Use wire ties and wire management clips from fastener pack to secure wires.
10. Install bulbs into each socket. Use gloves to avoid di­rect contact with the bulbs as the oil residue from hands will shorten the life of the bulb.
11. Remove two (2) screws in front of each of the bulb sock­ets and install the light cover with the two (2) removed screws. Use three (3) additional screws from hardware
pack to attach the light cover to the rebox top (1 each
side, 1 at back). Repeat steps for opposite side. See Figure 6.
Light Covers
12. Plug power cord into junction box.
13. Reattach the rear access panel with six (6) screws pre­viously removed.
14. Reattach the side access panel without the dimmer switch with one screw previously removed.
15. Reattach the side access panel with the dimmer switch by adjusting the rheostat to align with the hole in the venting support so that the stem of the rheostat sticks through. Attach with one screw previously removed. See Figure 7.
16. Reattach knob onto stem of rheostat.
17. Reinstall rebrick panels, burner and log set if previ­ously installed. Refer to burner/log set instructions for correct placement.
Figure 6 - Light Covers
Rheostat Positioning
Figure 7 - Rheostat Positioning
Monessen, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 50044
Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18