Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
VFF36C
VFF36L
48-3/4"
[1238]
Actual Framing Actual Framing Actual Framing Actual Framing
41 41-1/4 32 41-1/4 34-1/2 35 20-5/8 17-1/2
48-3/4" [1238]
37-1/8"
[943]
68-7/8"
[1749]
Aria 36
Vent Free Fireplace System
36 x 21-3/4
Aria VFF36
1/2" or 5/8"
Min. Rough
Opening
Height
32" [813]
27-3/8" [695]
41-1/4" [1048]
Min. Rough Opening Width
20-5/8"
5-7/16"
[138]
Min. Rough
Opening
Depth
17-1/2"
[445]
[524]
18"
[457]
35"
[889]
Additional information can be found online at www.monessenhearth.com
36" [914]
2-1/2" [64]
41" [1041]
34-1/2"
[876]
21-3/4"
[553]
6"
[152]

Specifications
9"
Minimum
9"
Minimum
42" Minimum
Aria VFF36
DETERMINE UNIT SIZE
See homowner’s manual for information on determining
the proper size unit for the space required.
APPLIANCE LOCATION
MANTEL PROJECTIONS
Combustible
material can
contact top of
fireplace
2-1/2"
6"
12"
8"
16"
12"
10"
23"
21"
19"
CLEARANCES TO COMBUSTIBLES
Back Wall Clearance — The appliance may be
placed against a combustible back wall.
Floor Clearance — The fireplace may be installed
directly on a combustible floor or a raised platform of an
appropriate height. Do not place fireplace on carpeting,
vinyl, tile or other soft floor coverings. It may, however,
be placed on flat wood, plywood, particle board or other
hard surfaces. Be sure fireplace rests on a solid continuous floor or platform with appropriate framing for support
and so that no cold air can enter from under the firebox.
MANTEL LEG PROJECTIONS
1"
2-1/2"
3"
5"
6"
7-1/2"
Non-combustible material
Finish Wall
Combustible
Material Area
1-1/2"
3-1/2"
4-1/2"
6"
7-1/2"
9"
45°
Paris, KY Phone: (877) 863-4350
Web: www.monessenhearth.com
PRODUCT LISTING CODES
US
Additional information can be found online at www.monessenhearth.com
ANSI Z223.1 / NFPA54
ANSI Z21.11
CSA Design Certified
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
GS/MON/VFF36_0116