Monarch Water PLUMBSOFT PS12 Programming And Installation Instructions

PLUMBSOFT PS12 AUTOTIMER WATER SOFTENER
PROGRAMMING & INSTALLATION INSTRUCTIONS Effective December 2010.
Thank you for choosing our water softener. Please read the following carefully, which if followed correctly, should ensure the installation is trouble free.
J. FAST FLOW DRAIN KIT
Where a drain is not readily available. A Fast Flow Drain Kit may be used and is available from us. Ref: FFDK Please note that the Fast Flow Drain Kit cannot be used on overflow connections.
K. OVERFLOW CONNECTION
The hose for the overflow should be cut from the drain hose provided. The overflow connection is the ½” hose spigot on the rear of the cabinet. No clip is required. The overflow must be run downhill through an outside wall without kinks or restriction. It is recommended the overflow hose be run to over an outside gully whenever possible with a clear 20mm air gap at the end of the hose. A 22mm copper protective sleeve through the outside wall will help prevent kinking of the hose.
L. TEST INSTALLATION FOR LEAKS
Close Inlet and Outlet valves to the softener and open Bypass valve. Open mains stopcock slowly and flush the new pipe work and connections via an adjacent mains tap. Ensure the tap used is not a hard water tap. Check all connections for leaks.
M. OBTAIN YOUR WATER HARDNESS
These instructions apply to the enclosed test kit only. Run hard water for approx. 1 minute and rinse the test tube well. Fill the test tube up to the 10ml level. Add 2 drops of the dark solution and mix gently. If the water sample contains hardness it will turn red. Add the dark solution in batches of 5 drops, holding the dropper bottle at 45 degrees. Mix gently after each 5 drops. Count the drops needed until the colour of the sample in the test tube changes from a dark red to a dark blue/green. You will need this figure for the ‘Settings Chart’.
Fig 1.
Programming the Electro Mechanical Timer
The electro-mechanical timer is fully automatic. It uses a 12-day skipper wheel to activate the regeneration.
Fig 1. Fig 2.
Time of Regeneration
This has been pre-set to 2am. If Economy 7 electricity is used during the night, ensure that appliances do not use water between 2 and 3.30am. Alternatively, you can alter the regeneration time by loosening the centre screw then turn the REGEN TIME wheel to the appropriate time and then retighten screw.
Time of Day
Turn the timer knob (k) anticlockwise until the correct time of day on the clock appears in the TIME OF DAY window.
Days of Regeneration
With all skipper pins (E) pulled out, push in the pins as determined by the chart and details below relevant to your installation.
Settings Chart
Family Size
Up to 30 drops
31-40 drops
41-50 drops
1 person A B
C
2 people C D
D
3 people D E
E
4 people E E
E
Pin Settings
A = push in pins 1 & 7
D = push in pins 1, 3, 5, 7, 9 & 11
B = push in pins 1, 5 & 9
E = push in all pins or consider larger softener with
C = push in pins 1, 4, 7 & 10
greater capacity/less frequent regenerations.
Finalise Commissioning
1. Fill softener with tablet salt only, before you turn on the water supply. Please advise customer to keep
the softener full at all times using tablet salt – see USER MAINTENANCE below…
2. Close Bypass valve, then slowly open both Inlet and Outlet valve and allow softener to pressurise and salt
chamber to fill – approx 10 minutes.
3. Check for leaks.
4. Connect plug top and turn on power.
USER MAINTENANCE
The softener requires minimal maintenance. Simply keep the unit topped up with salt. The softener will require topping up when or before you see water. We recommend that the softener be topped up twice a week. Never let the salt go below the water level. USE TABLET SALT IN EVERY INSTANCE. Water softener guarantee becomes void if granular salt is used!
MONARCH WATER Ltd, HALESWORTH ROAD, BRAMFIELD, SUFFOLK, IP19 9HP. Tel 01986 784759. Fax 01986 784769
Loading...