Paperless Recording Systems
Industry demands a higher level of reliability, better efficiency, more flexibility
and lower costs. These industry requirements were kept clearly in
focus when we designed our fourth generation of
Paperless Recording Systems:
The Data-Chart 2000 Series
Because your data is so important Data Chart recorders were designed to
be ultra-reliable. We chose the finest components available and combined them
with a robust modular mechanical structure. Our optimized design means fewer
components are needed. Fewer components means fewer failures.
Up to 2 Megabytes of non-volatile memory keeps your data safe. You will never
lose recorded data, even during a power outage. Data is downloaded automatically to your choice of removable media: 3.5” 1.44 Meg disk or CompactFlash™ card (up to 2 Gig in size).
Time is Money! Corporate down-sizing and cost cutting leaves you with less
time to accomplish your goals. Data-Chart recorders are virtually maintenance
free. No paper or pens to replace, no mechanical parts to wear out and because they are digital instruments, they requires less time to calibrate. This
allows you to use your time more efficiently.
Simple Setup
Our intuitive touchscreen control makes configuring the DC2000 a breeze. We
make full use of our screen with a large, easy to follow menu system.
We’re Flexible. Data Chart recorders are unparalleled in providing the highest level of flexibility of any paperless recorder made in the world. Universal
inputs, networking capability, powerful math packages and a multitude of
display choices allow you to display, record and communicate your data the
way you want.
Display Modes
You can choose from more than
20 different display modes
including trends, bargraphs and
digital indicators. Select pen
colors, background colors and
much more.
Outstanding Viewability
The DC2000 has a brilliant 5.6” TFT active matrix color LCD display which is the
largest of any 144mm square recorder. We’ve even added a special anti-glare
coating to optimize viewability under any conditions.
Companion Software is a powerful and intuitive Windows based applica-
tion that allows you to monitor real time data or review previously recorded data
in graphic or tabular format, search files for specific events, link alarm and event
files to trended data, print graphic or tabular files and export files to spreadsheet applications such as Excel.
Recorder configurations are easily generated using Companion Software and
can be downloaded to your recorders storage media and transferred to the
recorder or transferred directly over ethernet or serial line communications.
Monitor, configure and control up to 32 units with the RS485 Modbus option or
control from remote locations using a modem connection. Whatever the application, Companion Software puts you in complete control.
Guardian Software allows you to create a complete single station data super-
visory and storage system. If you need to monitor data in real time or if you
require redundant data storage to a PC, Guardian Software is the solution.
Multiple Data-Chart 2000’s can be placed on a standard ethernet or Modbus
network along with your other plant instruments and monitored in real time. In
addition, data can be stored on your local PC greatly improving data management and security!

DD
AA
TT
D
DD
A-CHARA-CHAR
A
T
A-CHAR
AA
TT
A-CHARA-CHAR
T 2000 SERIEST 2000 SERIES
T 2000 SERIES
T 2000 SERIEST 2000 SERIES
Specifications
Operating
Input Signals DC Voltage: Linear, Industrial square root, logarithmic DC Current: 4-20mA, 0 to 20mA and 10 to 50 mA.
Thermocouple: Resolution: 0.1°C, CJR accuracy: 0.5°C (0 to 50°C) RTD: Base accuracy 0.2% or 0.5°C (1°F). Resolution 0.1°C 2 or 3 wire
Type Accuracy Thermocouple burnout detection. connection. Cable compensation to +/- 50 ohm open and short circuit detection.
J* 0.1% J -101 to 1200°C +/-1.5°C -150 to 2190°F +/-3.0°F
K** 0.1% K -101 to 1372°C +/-1.5°C -150 to 2500°F +/-3.0°F 10 ohm Cu -70 to 170°C -94 to 338°F
T** 0.2% T -101 to 400°C +/-1.5°C -150 to 750°F +/-3.0°F 100 ohm Pt 385 -220 to 850°C -364 to 1560°F
E** 0.11% E -101 to 1000°C +/-1.5°C -150 to 1832°F +/-3.0°F 100 ohm Pt 392 -180 to 820°C -292 to 1500°F
R 0.16% R -50 to 1768°C +/-3.0°C -58 to 3200°F +/-6.0°F 200 ohm Pt 385 -220 to 400°C -364 to 750°F
S 0.17% S -50 to 1768°C +/-3.0°C -58 to 3200°F +/-6.0°F 200 ohm Pt 392 -180 to 400°C -292 to 750°F
B 0.22% B 0 to 1820°C +/-4.0°C 32 to 3300°F +/-7.0°F 120 ohm Ni -70 to 300°C -94 to 570°F
C 0.13% C 0 to 2400°C +/-3.0°C 32 to 4350°F +/-6.0°F 1000 ohm Ni -60 to 209°C -76 to 408°F
N** 0.10% N -101 to 1300°C +/-1.5°C -150 to 2372°F +/-3.0°F (DIN 43760)
Input Resolution 0.0015% of full scale, 16 bit unless otherwise stated
Input Impedance > 10 Meg on 150mV, 1.25V and 2.5V ranges, >100 K on 5, 12.5, 25 Volt ranges.
Input Channels 2, 4, 6 or 12
Max Input 50 Vdc
CMNR >100db, 50/60 Hz
Measurement Rate Measures all direct input channels every 125 milliseconds (each channel 8 times/second independent of no. of channels).
Math Functions +, -, x, /, logarithms, totalization, powers, averages, timers, and custom equations.
EMC Compliance Meets or exceeds the requirements of EMC 2014/30/EU
+/- 150mV, +/-1.25V, +/- 2.5V Accuracy: 0.06% Accuracy: 0.15% using external 50 ohm 0.1% shunt.
+/- 12.5V and +/- 25V Accuracy: 0.1%
Dry Contact: Open = 0, Closed = 1 External: Signals can be input via serial port (Modbus).
* (+/-2.5°C -210 to -100°C) **(+/-2.5°C -270 to -100°C)
Isolated Input Modules
Recording
Recording Rates Selectable from 8/sec. to 10 minutes
Data Format Proprietary binary format for data security.
Data Storage Data stored in non-volatile RAM and recorded automatically, or on demand, to on board removable media.
Removable CompactFlash Card 950 Million (Up to 2 GB in size).
Internal 1 Mb RAM (Non-Volatile) Standard
File Types Data files, Alarm and Event files, Configuration files, Language files.
Full media format and verify capability.
Media Measurements Capacity
2 Mb RAM (Non-Volatile) Optional
Multiple files of different names on a single disk.
Display
Display Type Color CCFL backlit Active Matrix TFT Liquid Crystal Display (5.6 inch) with touchscreen control.
Display Modes Graphics (Trending vertical or horizontal), Bar Graphs (vertical or horizontal), Digital Meters, Alphanumeric Alarm and Event
Virtual Chart Speed Programmable from 0.5in/hr to 600in/hr or 10mm.hr to 15,000mm/hr. Chart speed is independent of storage rate.
Display Windows Time/Date, Graphics (Bars, Large Digital, Trends), Disk Status, Systems Status, Menu Button Bar, Unit Identification,
Power Requirements 100 to 240Vac, 50/60Hz or 125 to 300Vdc, 35VA max.
Power Fail Protection Programmed parameters stored in non-volatile memory. Clock battery backed. Data retention time without power >12 months.
Safety CE low voltage directive 2014/35/EU. Complies with EN 61010-1:2010.
320 x 240 pixels.
Data or combinations on a split screen. Review trended data. Search by time, date or signal value.
Alarms/Events.
Optional 24Vdc +/-15%.
Chart and alarm browse buffers stored in non-volatile memory.
Operating Environment
Temperature -10°C to 50°C
Humidity 10% to 80% RH per EN 61010-1:2010.
Wash Down IP65 Front panel only.
Options
Alarm Contacts 3 or 6 isolated Form C, 3 amp @ 250Vac or 26 Vdc.
Remote Inputs 3 isolated inputs, user selectable as dry contact or 5 to 12 Vdc (mech. relay), 12 to 24 Vdc (SS relay) activated.. Inputs
Communications ESD protected RS232 with full hand shaking. Supports modem or isolated RS485 port.
Printer Port Parallel printer port (25 pin D shell connector).
share a common. Configurable for chart control, alarm acknowledge/reset, event markers, totalizer reset or logic input.
Protocol: MODBUS RTU, MODBUS ASCII or serial printer port. Ethernet: 10BaseT. Unit may be remotely configured.

DD
D
DD
AA
TT
A-CHARA-CHAR
A
T
A-CHAR
AA
TT
A-CHARA-CHAR
T 2000 SERIEST 2000 SERIES
T 2000 SERIES
T 2000 SERIEST 2000 SERIES
Ordering Information
Display
C TFT Active Matrix Display
M Monochrome Display
Power
1 90-127, 194-264 Vac
2 18-30 Vdc
1st 90-264 Vac w/screw terminal connectors
Isolation Input Modules
Module Channels Description
U2 2 Universal DC V/I T/C and RTD
U4 4 Universal DC V/I T/C and RTD
U6 6 Universal DC V/I T/C and RTD
U12 12 Universal DC V/I T/C and RTD
Data Storage-Removable
0 3.5” Disk Drive
1 Compact Flash Card Drive
Output Options
0 No Alarm Outputs
1 6 Form C Relays 3A@250 Vac, 3 Ctrl inpt.
2 3 Form C Relays 3A@250 Vac, 3 Ctrl inpt.
Communications
0 None
1 RS485 / RS232 - Isolated
2 Ethernet - 10BaseT
Data Storage - Internal
0 1 Mbyte
1 2 Mbyte
DC2
Accessories
50 ohm precision external shunt
resistor for current inputs (+/-0.05%).
External USB port card reader.
Companion Software for Windows
95, 98,NT, XP and 2000.
Guardian Software for Windows
95, 98, NT, XP and 2000.
Portable maintenance kit. Includes:
Rubber feet and carry handle.
(factory installed)
Nylon padded carrying case with
shoulder strap. Will hold recorder,
power cable and diskettes.
256MB, 512MB, 1 Gig or 2 Gig
CompactFlash™ memory cards.
MAS50R
CFCR
SW-3T
GUARDIAN
PMK-2
CC-8
MC256MB
MC512MB
MC1024MB
MC2048MB
Printer Port
0 None
1 Parallel Printer Port (25 Pin D Shell)
Example Model Numbers:
DC - 2C1 - U4 - 11200
DC - 2M1 - U12 - 00000
15 Columbia Drive
Amherst, NH 03031-2334
Tel: (603) 883-3390 Fax: (603) 886-3300
e-mail: sales@monarchinstrument.com
www.monarchinstrument.com
DC-2000 Installation Dimensions
Distributed by:
IBM is a registered trademark of International Business Machines, Excel, MS-DOS and Windows are all trademarks of Microsoft Corporation. MODBUS is a registered trademark of Modicon Corporation.
Specifications subject to change without notice. Printed in USA 03/18 TJF Digital Version