POWERCENTER PRO 2000 FEATURES
1. ON/OFF Switch: This switch turns the PRO 2000 on and off.
The switch lights up when turned to the “ON” position, providing
power to components plugged into the switched outlets. Pressing
the switch to the “OFF” position shuts off power. This switch
also acts as the reset for the PRO 2000’s 15-amp thermal
breaker, which automatically cuts off power to protect connected
components from over-voltage situations.
2. Coaxial Video Monitor/Satellite Antenna Input/Output:
Allows you to hook up a video monitor or satellite antenna,
and protect your system against power surges coming from them.
3. GROUND OK Indicator: Indicates the wall outlet
that the PRO 2000 is plugged into is properly grounded.
4. PROTECTION ON Indicator: Indicates the PRO 2000’s
internal surge protection is active.
2
Top View
11
1
5. WIRING FAULT Indicator: Indicates that a wall outlet
is incorrectly wired.
6. Telephone/Network Input/Output: Allows you to hook
up to telephone lines (RJ11) or networks (RJ45), and protect
your system against power surges coming from them.
7. High Current Filtered Outlets: These outlets are intended
for power-hungry devices like amplifiers and powered monitors
that require high amounts of current for optimal performance.
8. Analog Filtered Outlets: These outlets have a special filter
circuit that reduces audible noise in your analog musical
and professional audio components.
9
8
14
13
10
9. Digital Filtered Outlets: These outlets have a special filter
circuit that reduces audible interference in your digital musical
and professional audio components.
10. Current and Voltage Availability LED Meters:
These digital meters provide constant status regarding
the quality and stability of the power coming from
the wall outlet to your PRO 2000.
11. Extra heavy duty, 10ft. shielded power cord: This power
cord’s extra length enables flexible placement of the PRO 2000
to reach inconveniently located wall outlets. The cord’s rugged
heavy duty, shielded construction protects it from damage
while also rejecting RF interference. The cord can be conveniently
wrapped around the unit’s end caps for easy storage.
2
Top View
11
1
12. Gold-plated, three-prong plug: This plug features
24k gold-plated contacts for maximum power transfer.
It can be snapped onto the power cord.
13. Rubberized ABS-Plastic End Caps: These end caps
enhance the PRO 2000’s durable chassis. The unit’s power
cord can be wound around the end caps.
14. Aluminum Extruded Exterior: This rugged chassis provides
an high level of protection and stability when used in its intended
operational environment.
9
8
14
13
10
P O W E R C E N T E R P R O 2 0 0 0
3
5
4
6
7
8
P O W E R C E N T E R P R O 2 0 0 0
3
5
4
6
7
rm 165023
PROFESSIONAL POWERCENTER PRO 2000
Visit us on the web at monsterpower.com
Monster, LLC.
8
and other countries. All other company and product names may be trademarks of their respective companies.
“Pre Power”and “Multiple SurgeGuard” are trademarks of Monster Cable Products, Inc., or its subsidiaries in the United States
Copyright ©2003 Monster Cable Products, Inc. All rights reserved. “Monster” “Monster Power” “POWERCENTER”
7251 Lake Mead Blvd West, 3rd Floor • Las Vegas • NV 89128
O W N E R ’ S M A N U A L
PRO 2000
TM
®
Professional PowerCenter
INTRODUCTION
Thank you for purchasing Monster’s PRO 2000 PowerCenter.
The PRO 2000 proudly reflects Monster’s unwavering commitment
to creating the ultimate performance-enhancing solutions
for professional audio applications, giving you superior component
operation, the highest audio quality, and the best protection
for your precious equipment and instruments.
Ideal for high quality performance environments and studios,
the PRO 2000’s patented Clean Power ™ Stage 2 filter circuitry virtually
eliminates the noise that goes right through typical surge protectors.
Two isolated filters, optimized for analog and digital equipment,
provide excellent AC power line noise rejection and isolation
of analog gear from digital components for improved componentgenerated noise rejection, leaving you with more natural tone, increased
dynamic range and none of the “dirty” AC-induced gremlins that would
otherwise interfere with the way you and your gear perform. Four high
current filtered outlets provide power-hungry amplifiers with the current
they need to operate with maximum headroom, the best transient
response and the clearest tone.
immediately suppresses it before it can reach your gear, and will emit
an audible alarm to let you know that surge suppression occurred.
Plus, the PRO 2000 has a pair of coaxial connectors and a pair
of telephone/network connectors, so you can hook up a computer,
a video monitor or a satellite receiver with the confidence that
you’ve got total equipment protection. Another Monster breakthrough
is the PRO 2000’s ultra low loss RF protection, which, unlike other surge
protectors, provides complete protection with virtually no signal loss.
The PRO 2000’s two separate digital LED meters (“Voltage Availability,”
“Current Draw”) and three indicator LEDs (“Protection On,” “Ground
OK,”and “Wiring Fault”) report the status of the power coming from
your wall outlet and alert you if there are problems. All of the PRO 2000’s
12 switched AC power outlets are widely spaced to accommodate bulky
“wall wart” adapters, and the unit’s illuminated power switch also serves
double duty as a 15-amp thermal breaker, providing a convenient reset
for those instances where the PRO 2000 automatically cuts off power
to protect your gear.
INTRODUCTION
With its aluminum extruded exterior and rubberized finish,
the PRO 2000 is rugged, road-ready and built to deliver clean, safe
power no matter where your music takes you. You’ll really appreciate
its 10-ft long, extra heavy duty, shielded power cord—it’s length lets
you place the PRO 2000 wherever shared power is needed most,
and the cord can be conveniently wound around the unit’s end caps
for trip- and tangle-free portability.
About Noel Lee, The Head Monster
The driving force behind the success of the PRO 2000 and the entire Monster Power family is Noel Lee, The Head Monster.
Noel is best known for popularizing the concept of high performance audio cable over 20 years ago with his creation
of Monster Cable. Originally a laser-fusion design engineer at Lawrence Livermore National Laboratory and later a touring
musician, Noel has invented or co-invented over 125 U.S. and international patents and drives the explosive growth
of The Monster Group into more than 80 countries worldwide. Monster Power is his realization of a long-nurtured vision
of making affordable power solutions that deliver the best possible sound and picture.
The three-prong plug, which features 24 karat gold-plated contacts
for maximum, instantaneous power transfer, can be snapped onto
the power cord when you’re ready to pick up and go.
Clean power, clean sound, complete protection and total
convenience for all professional audio applications. Just like you expect
in a Monster Power product . . . because you
from the Monster.
get
more of everything
The Head Monster
SAFETY P R E C A U T I O N S
The PRO 2000 is equipped with Monster’s fast-acting, high-capacity
2775 Joule, Multiple SurgeGuard ™ and Dual-Mode Plus Protection
Circuitry, which instantly detects any voltage surge or spike,
A B O U T P O W E R C E N T E R P R O 2 0 0 0
COAX SECTION OF
POWERCENTER
PRO 2000
POWERCENTER PRO 2000
COAXIAL INPUT/OUTPUT CONNECTION
GROUNDING BLOCK
ON COLD WATER PIPE
OR GROUNDING ROD
DISH
CABLE TV
OR
CABLE
MODEM
OR
VCR
TV
SIGNAL
SPLITTER
HOOK-UP GUIDE HOOK-UP GUIDE
I N S T R U C T I O N S
STEP 1 Outlet Hook-up
Because certain components don’t need continuous power, or shouldn’t be powered continuously, all of the PRO 2000’s outlets are “switched.”
This means the components you plug into the PRO 2000 won’t receive power until your unit is turned on.
The PRO 2000’s outlets are grouped into three different sections according to specific filter circuitry that is used to eliminate noise and optimize
performance for particular types of components. When connecting your gear to the PRO 2000, please select an outlet within the group whose
label most closely reflects the type of component you want to use —the descriptions below should help you make the correct choice:
• Analog Filtered Outlets
Most analog components, like foot pedals and tube preamps, create
audible noise that can easily interfere with your signal. These four
outlets have a special filter circuit that reduces audible noise
in your analog musical and professional audio components.
POWERCENTER PRO 2000
Analog Filtered Outlets
STEP 1 Outlet Hook-up (Continue on left page)
• Digital Filtered Outlets
While digital components like multi-effect units and computers don’t generate the noises you might associate with analog equipment,
their reliance upon clock frequencies and their vulnerability to different bands of noise can create equally problematic interference
for your signal. These digital filtered outlets have a special filter circuit that reduces audible interference in your digital musical
and professional audio components.
• High Current Filtered Outlets
These outlets are intended for power-hungry amplifiers, powered subwoofers and other similar devices that require high amounts
of current for optimal performance. Other components will function as intended if connected to these outlets, but devices requiring
high current will operate best when plugged into these outlets.
I N S T R U C T I O N S
POWERCENTER PRO 2000 - Digital Filtered Outlets
I N S T R U C T I O N S
HOOK-UP GUIDE
STEP 2 Coaxial Cable TV Hook-up
NOTE:
You will need additional coaxial cables to connect your PRO 2000 to your components.
See illustration in Step 4, which shows a proper grounding schematic.
Protect Your Video Monitor/Satellite Antenna/Cable Modem Incoming Coax Line as Follows:
• From Ground Block (connected to incoming line)
• To Computer, Video Monitor or Satellite Receiver
• + See illustration in Step 4
STEP 3 Telephone/Network/Cable Modem Hook-up
NOTE:
You will need additional phone/network cable to connect your PRO 2000 to your components.
Protect Your Computer
• From incoming phone or network line
• To Computer
POWERCENTER PRO 2000 - High Current Outlets
HOOK-UP GUIDE
STEP 4 GROUNDING YOUR Computer, Video Monitor or Satellite Receiver
Proper grounding can be accomplished by using a special grounding block attached to a cold water pipe or copper ground rod driven
into the ground. Consult with an electrician to verify your outdoor connections are grounded properly.
TV/Satellite/Cable
Modem Protection
I N S T R U C T I O N S
I N S T R U C T I O N S
TROUBLESHOOTING
PROBLEM – The PRO 2000 is not receiving power.
Possible Cause #1
The PRO 2000 is not turned on.
Possible Solutions
• Press the PRO 2000 switch into the “ON” position.
• Make sure the PRO 2000’s AC power plug is plugged into a properly
grounded 120V wall outlet.
• In some venuses or studios a wall switch may need to be thrown
to make the wall outlet come alive. Try turning on the light switches
located near the wall outlet that should be powering the PRO 2000.
Possible Cause #2
Too many devices are connected, causing an overload, throwing
the Thermal Circuit Breaker. Please note: The total power consumption
on all the components powered by the PRO 2000 should
not exceed 1875 watts.
Possible Solution
•
Press the PRO 2000’s combination ON/Off/Thermal Circuit Breaker
switch into reset. Please allow 10 minutes from the time
the Circuit Breaker is initially thrown before attempting to reset.
If you reset too soon, the breaker will prematurely sense power
overload and not allow the unit to operate.
Possible Cause #3
The PRO 2000 power cord is plugged into an outlet on the back of one
of your components and the component is not turned on.
Possible Solutions
•
Turn the component power on.
NOTE: For the best possible performance, plug the PRO 2000
into a wall outlet, not an outlet on another component.
Phone/Network/DSL Protection
PROBLEM – The PRO 2000 is not providing power
to the other components.
Possible Cause #1
The component is plugged into a switched outlet and the PRO 2000
has not been turned on.
Possible Solutions
•
Turn the PRO 2000 on.
Possible Cause #2
PRO 2000 is plugged into a switched outlet on a component
that is not turned on.
Possible Solution
•
Turn on the component.
NOTE: For best possible performance, plug the PRO 2000
into a wall outlet, not an outlet on another component.
PROBLEM – Speakers, monitors or headphones emit
a humming or buzzing noise.
Possible Cause
The PRO 2000 is sharing AC power with equipment
that is not properly grounded.
Possible Solution
•
Connect your PRO 2000 to a dedicated outlet.
Properly Grounding Your System
PLEASE READ AND OBSERVE THE FOLLOWING SAFETY POINTS AT ALL TIMES
WARNING – POWER SOURCES
Do not plug your Monster POWERCENTER into a power outlet that differs from
the source indicated for safe use on the Monster POWERCENTER. If you don’t know
the type of electrical power that is supplied to your home, please consult your local
power company.
WARNING – GROUNDING AND POLARIZATION
A. Your Monster POWERCENTER has a three-wire grounding-type AC plug (a three-prong
plug). This plug is designed to be inserted into a grounding-type outlet only. If this plug
doesn’t fit directly into your outlet, do not attempt to force it into the outlet. Instead,
reverse the plug and reinsert it. If this doesn’t work, contact a local electrician to install
the proper polarized outlet. Never attempt to dismantle the plug in any way (or to alter
an extension cord) to make it fit into a two-prong outlet. Do not attempt to defeat
the grounding feature by using a 3-to-2-prong adapter. Instead, call a local electrician
to install a properly grounded outlet.
B. If you use rooftop devices such as satellite dishes, antennas, or any other component
with wire that connects to your Monster POWERCENTER, be sure the wire(s) is properly
grounded. This protects against voltage surges and static charges. Do not place any part
of an antenna near overhead power lines, or any other power circuit. Do not touch any
power line or power circuit. Doing so may cause you severe physical injury and possibly
result in death.
WARNING – STORM PRECAUTIONS
In the event of a lightning storm, immediately disconnect your Monster POWERCENTER
from its power source. After you’ve done this, it’s not necessary to disconnect
any components from your Monster POWERCENTER.
WARNING – NO USER SERVICEABLE PARTS INSIDE
If, for any reason, your Monster POWERCENTER is not operating properly, do not remove
any part of the unit (cover, etc.) for repair. Unplug the unit and consult this owner’s manual
P R O B L E M S A N D S O L U T I O N S
for warranty and service information.
WARNING – EXPOSURE TO HEAT
DO NOT EXPOSE YOUR MONSTER POWERCENTER TO DIRECT SUNLIGHT OR PLACE
IT NEAR WALL HEATERS, SPACE HEATERS, OR ANY ENCLOSED SPACE PRONE TO
TEMPERATURE INCREASE (E.G., CAR TRUNK).
WARNING – LIQUID: AVOIDING ELECTRICAL SHOCKS
Do not operate your Monster POWERCENTER if liquid of any kind is spilled onto or inside
the unit. Do not operate your Monster POWERCENTER near rain or water that’s spilled
or openly exposed (e.g., bathtub, kitchen or bathroom sink).
WARNING – POWER CORD SAFETY
A. When routing your Monster POWERCENTER AC power cord, do not place it near
heavy foot traffic areas (e.g., hallways, doorways, and kitchen floors). Do not create a trip
hazard with the power cord.
B. If your power cord’s protective jacket begins to rip or fray, exposing the internal wiring,
shielding, etc., disconnect it from the power source and discontinue use of the Monster
POWERCENTER immediately. Please see warranty information.
WARNING – PROPER CLEANING
In general, the only cleaning necessary for your Monster POWERCENTER is a light
dusting. Unplug your component from the wall outlet before cleaning it. Do not use
any type of liquid or aerosol cleaners.
WARNING – MEDICAL CONDITIONS
The POWERCENTER is not intended to be mounted on a desk or a similar
furnishing surface.