Datasheet
EASYL CK
Filters
Protection against Gas, Vapour & Dust
For Series 7000 and 9000 masks
®
Gas fi lters
9100 A1
9200 A2
9300 ABE1
EASYL CK
CHARACTERISTICS
9400 ABEK1
9500 A2B2E1
9600 AX
®
filter system
Particulate fi lters
9010 P1 R
9020 P2 R
9022 P2 R+ Ozone
9030 P3 R
9032 P3 R+ Ozone
MATERIAL
Pre-assembled fi lters
9120 A1P2 R
9230 A2P3 R
9430 ABEK1P3 R
9730 ABEK1HgP3 R D
· Particulate filters can either be directly combined with the EasyLock®
gas cartridges or directly connected with the mask body.
· Easy handling as no adapters or particulate filter holders are necessary
with the Moldex EasyLock
· The unique Moldex Pleated Filter Technology reduces breathing
resistance and considerably increases the capacity of the particulate
filters.
· The pre-assembled filter combinations offer the simplicit y of combined
filters and are more economical at the same time due to exchangeable
pre-filters.
· Simpler logistics, on average 30% less parts are required with the
· 100% PVC-FREE: All Moldex products and packaging are 100% PVC-free
CERTIFICATION
The EasyLock® fi lters meet the requirements of EN 14387:2004 + A1:2008 and
EN 143:2000 + A1:2006 and are CE-marked in accordance with the requirements of European Directive 89/686/EEC. The Institut für Arbeitsschutz IFA
(BGIA) in St Augustin (0121) in Germany is the body responsible for both type
examination (article 10) and monitoring of products (article 11). The products
are manufactured in an ISO 9001:2000 certifi ed plant.
EasyLock
®
-System.
®
-System.
Particulate filter: Polypropylene
Particulate filter 9022, 9032: Active Charcoal
Particulate filter holder: Polypropylene
Gas filter: Active Charcoal
Gas filter cartridge: Polypropylene
WEIGHT (apiece)
9100 : 66 g 9600: 112 g 9032: 27 g
9200: 87 g 9010: 18 g 9120 : 84 g
9300: 67 g 9020: 18 g 9230: 117 g
9400: 92 g 9022: 24 g 9430: 122 g
9500: 109 g 9030: 30 g 9730: 127 g
IMPORTANT INFORMATION FOR USERS
· The mask and the filters must be selected in accordance with the
pollutant concentration. (see tables 1,2 and 3)
· In the case of gases with insufficient warning properties, filters may
only be used if special usage policies are specified for this purpose.
· If the conditions are uncertain or changeable, a self-contained breathing apparatus must be worn.
· The product does not contain any metallic parts that could cause
ignition in potentially explosive atmospheres.
www.moldex.com
UK - 04 - 2012 / 01 - EasyLock

Datasheet
EASYL CK
Filters
Protection against Gas, Vapour & Dust
®
SERVICE LIFE OF THE CARTRIDGES AND
PARTICULATE FILTERS
If you can smell gases or vapours when you use the gas fi lters, they are exhausted and must be replaced (no later than 6 months after the original packaging
is opened). Replace the particulate fi lter if the breathing resistance increases
dramatically. The fi lters must always be replaced in pairs. You must adhere to
the use-by-date.
STORAGE
Keep the fi lters sealed in a dry, uncontaminated environment. Protect them
against sunlight and sources of heat.
FILTERS QUALIFY AS HAZARDOUS WASTE
They must be disposed of in accordance with the applicable waste disposal
regulations. Information is provided by your local responsible authority.
GAS FILTER MODEL EN 14387 table 1
Model Colour Area of application
A Brown Organic gases and vapours, boiling point > 65°C
B Grey Inorganic gases and vapours, boiling point > 65°C
E Yellow Acid gases (e.g. sulphur dioxide, hydrochloric acid)
K Green Ammonia
AX Brown Organic vapours boiling point ≤ 65°C
Hg P3 Red-White Mercury
PARTICULATE FILTER CLASS
EN 143:2000 + A1:2006
Class Maximum use level with
halfmask Series 7000
P1 R 4 x WEL *
not against carcinogenic and
radioactive materials, not against
micro-organisms and enzymes
P2 R 10 x WEL *
not against radioactive materials,
viruses and enzymes
P3 R 20 x WEL * 40 x WEL *
P2 R +
In addition to the particle fi ltering effi ciency these fi lters also offer
P3 R +
protection against ozone; at 1000ppb ozone a maximum use time
Ozone
of 8h.
* WEL = Workplace Exposure Limit
R: The fi lters are reusable.
Due to the low weight of fi lters of less than 150 g per fi lter (-combination) all fi lters
can be used for both, the full face mask and the half mask.
Quality control and EC type-approval offi ce:
IFA (BGIA); Identifi cation number: 0121; 53757 Sankt Augustin; Germany
Maximum use level with
fullmask Series 9000
4 x WEL *
not against carcinogenic and
radioactive materials, not against
micro-organisms and enzymes
10 x WEL *
not against radioactive materials,
viruses and enzymes
table 3
CAUTION: AX fi lters must only be used once. Low-boiling gases (≤ 65°C) generally bind poorly with gas fi lters. This may result in shorter periods in service.
Please refer to the relevant national regulations for information about the maximum
permissible application concentrations and times for the individual compounds. Only
use with vapours with good warning properties.
AX fi lters do not offer adequate protection against various low-boiling gases. If you
have any questions about how to use AX fi lters, please contact Moldex.
The fi lter 9730 ABEK1Hg P3 have a maximum use time of 50h against mercury.
GAS FILTER CLASS EN 14387 table 2
Class Maximum use level with
half mask Series 7000
1 1000 ppm (0.1 percent by
volume) or 10 x WEL*
2 5000 ppm (0.5 percent by
volume) or 10 x WEL*
* WEL = Workplace Exposure Limit
whichever is lower
Maximum use level with
full face mask Series 9000
1000 ppm (0.1 percent by
volume) or 20 x WEL*
5000 ppm (0.5 percent by
volume) or 20 x WEL*
INFO
For help on selection and training please contact us.
We offer a wide range of training packages and support material.
MOLDEX-METRIC AG & Co. KG
Unit 9, Glaisdale Point
Off Glaisdale Drive, Bilborough
Nottingham. NG8 4GP
Tel.: +44 (0)115 985 4288
Fax: +44 (0)115 985 4211
info@uk.moldex-europe.com
www.moldex-europe.com
www.moldex.com
UK - 04 - 2012 / 02 - EasyLock