8000 RESPIRATOR SELECTION GUIDE
8000 SERIES FACEPIECE ASSEMBLY
DESCRIPTION PACKAGING MODEL # SIZE
FACEPIECE
Includes head strap
valve assembly.
REPLACEMENT CARTRIDGES
HAZARD
ORGANIC VAPORS
Organic Vapors.
ACID GASES
Chlorine, Hydrogen Chloride,
Sulfur Dioxide, or Chlorine Dioxide; or
for escape only from Hydrogen Sulfide;
or Hydrogen Fluoride.
ORGANIC VAPORS/
APPROVAL MODEL # PACKAGING
TC-23C-1223
TC-23C-1224 8200 1 PR/BAG
TC-23C-1225
ACID GASES
Organic Vapors, Chlorine, Hydrogen
Chloride, Sulfur Dioxide, or Chlorine Dioxide;
or for escape only from
Hydrogen Sulfide; or Hydrogen Fluoride.
1 Facepiece/Bag
12 Bags/Case
1
8001 8002 8003
8100
8300 1 PR/BAG
S
M
L
1 PR/BAG
5 PRS/BOX
6 BXS/CS
5 PRS/BOX
6 BXS/CS
5 PRS/BOX
6 BXS/CS
AMMONIA/METHYLAMINE
Ammonia/Methylamine.
Use with gas-proof goggles.
FORMALDEHYDE
ormaldehyde.
F
OSHA regulations require
gas-proof goggles.
MULTI GAS/VAPOR
Organic Vapors, Ammonia, Methylamine,
Chlorine, Hydrogen Chloride, Sulfur
or Hydrogen Fluoride,
Dioxide,
Dioxide, or Formaldehyde, or Hydrogen
Sulfide (esca
or Chlorine
pe only).
P100 PARTICULATES
Dusts, Fumes, Mists
Radionuclides, Radon daughters
Asbestos-containing dusts
and
and mists.
1
Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging.
TC-23C-1369 8400 1 PR/BAG
TC-23C-1409 8500 1 PR/BAG
TC-23C-1809
TC-84A-1443
8600
8990
5 PRS/BOX
6 BXS/CS
5 PRS/BOX
6 BXS/CS
1 PR/BAG
5 PRS/BOX
6 BXS/CS
1 PR/BAG
5 PRS/BOX
6 BXS/CS
Page 2
8000 RESPIRATOR SELECTION GUIDE
ASSEMBLED RESPIRATORS WITH CARTRIDGES OR P100 DISKS
HAZARD APPROVAL MODEL # SIZE
1
ORGANIC VAPORS
Organic Vapors.
PAINT SPRAY/PESTICIDE
(includes 8910 N95 prefilters, 8020
retainers, 8100 cartridges) Paint, Lacquer,
and Enamel Mists, Pesticides, Organic
Vapors, and Dusts and Mists.
Waterbased Only.
Not for use against two-part isocyanate paints or oil
based particulates.
MULTI GAS/VAPOR
Organic Vapors, Ammonia, Methylamine,
Chlorine, Hydrogen Chloride, Sulfur Dioxide,
or Hydrogen Fluoride, or Chlorine Dioxide,
or Formaldehyde, or Hydrogen Sulfide
(escape only).
P100 PARTICULATES
Facepiece assembly with P100 disk
#8940 and Disk/Filter Holder #8900.
PAINT SPRAY/PESTICIDE
KIT With Free Paint Bucket
1 8000 Series Facepiece Assembly, 5 pairs 8910 N95 Prefilters, 1 8020
Filter Retainer, 1 pair SparkPlugs
TC-23C-1223
TC-84A-1337
TC-23C-1809
TC-84A-0117
TC-84A-1337
8101 8102 8103
8111N 8112N 8113N
8601 8602 8603
8941 8942 8943
8111KN 8112KN 8113KN
S
M
L
S
M
L
S
M
L
S
M
L
S
M
L
N95 Welding Particulates Plus
TC-84A-3901
8757
Nuisance levels of OV/Ozone
Facepiece assembly w/N95 filter
#8755 and Disk/Filter Holder #8900
PACKAGING: 1 Fully assembled respirator with cartridges and/or filters per resealable bag, 12 respirators/case.
1
Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging.
PREFILTER RETAINER, HOLDER, AND ADAPTER
HAZARD
PREFILTER RETAINER
0 or 8970 and
Use with 89
8000 Series Cartridges.
1
DISK/FILTER HOLDER
with retainer ring use with 8001, 8002, 8003 facepiece
assemblies and 8910, 8970, 8755 or 8940.
DISK PIGGYBACK ADAPTER
with retainer ring use with 8000 series cartridges and 8940.
MODEL # PACKAGING
8020
8900
8920
M
1 PR/BAG 10 PRS/BOX 5 BXS/CASE
1 PR/BAG
5 PRS/BOX
6 BXS/CASE
1 PR/BAG
5 PRS/BOX
6 BXS/CASE
Page 3
8000 RESPIRATOR SELECTION GUIDE
8900 SERIES FILTERS AND DISKS
HAZARD APPROVAL MODEL # PACKAGING
P100 PARTICULATES
Dusts, Fumes, Mists, Radionuclides,
Radon daughters and Asbestos-
containing dusts and mists.
N95 PARTICULATE
TC-84A-0117 8940
TC-84A-1343 8910
FILTER
Use with 8020 retainer and 8000 Series
cartridges, or standalone with
8900 holder.
R95 PARTICULATE
TC-84A-4248 8970
FILTER
Use with 8020 retainer and 8000 Series
cartridges, or standalone with
8900 holder.
N95 WELDING
TC-84A-3901 8755
PARTICULATE FILTER PLUS
NUISANCE OV/OZONE
Use as standalone with
8900 holder.
1
Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging.
1
1 PR/BAG
5 PRS/BOX
6 BXS/CASE
5 PRS/BAG
10 BGS/CASE
5 PRS/BAG
10 BGS/C
50 BGS/CASE
ASE
1 PRS/BAG
2
Use with 8001, 8002, 8003
PART #
8006 PROBED CARTRIDGE KIT
8007 ALCOHOL WIPES
REPLACEMENT PARTS
2
DESCRIPTION MODEL # PACKAGING
HEAD STRAP ASSEMBLY
Includes yoke, buckles
and 2 straps.
EXHALE VALVE ASSEMBLY
Includes holder and diaphragm.
Assembled Facepiece.
8000 FIT TEST PRODUCTS
DESCRIPTION PACKAGING
INCLUDES: 1 8006 probed cartridge, 1 pair 8940 P100 Particulate Disk,
1 pair 8900 disk holders, 1 pair 8920 disk piggyback adaptors, and
instructions. For use with TSI PortaCount.
0082
0083
1 PER BOX
100 WIPES PER
4/BAG
5 BGS/CASE
6/BAG
5 BGS/CASE
BOX
0701
TRAINING AND INSTRUCTIONAL MATERIAL
HOW TO SET UP A RESPIRATORY PROTECTION PROGRAM
According to OSHA guidelines
Page 4
RESPIRATOR TRAINING PROGRAMS
Moldex offers comprehensive training materials and programs on the use and care
f 8000 series respirators to help you meet OSHA, state and local regulations.
o
FFIITT TTEESSTTIINNG
Improve your respirator program with Moldex’s qualitative fit test kit and Probed Cartridge Kit for quantitative fit testing. Make sure your worker’s respirators fit satisfactorily. And ensure that your workers are wearing their respirators properly. M
G
oldex’s Fit Test Kits will help your respirator program meet OSHA requirements.
FACTORY-BACKED SUPPORT GROUP
oldex’s factory-trained sales force is available to help you and your workers take full
M advantage of the 8000 series respirator’s many safety and value features. In addition,
here are training materials available to help ensure the proper use of 8000 series
t respirators.
TTEECCHHNNIICCAALL SSEERRVVIICCEE HHEELLPP LLIINNE
toll-free technical service line to help answer your questions about respiratory
A protection and the use of all Moldex safety products.
ext. 550 or 310/837-6500 ext. 550.
E
Call 800/421-0668
MOLDEX-METRIC, INC.
10111 W. Jefferson Blvd. Culver City, CA 90232 800/421-0668 310/837-6500 FAX 310/837-9563 www.moldex.com e-mail: sales@moldex.com
Moldex is a registered trademark. U.S. Patents Pending 8000-701 REV K 8/06
In Canada:
Moldex-Metric, Inc. Pacesetter Sales & Associates 20 Arthur Hall Drive Sharon, ON L0G 1V0 Tel: 905/478-8042 Fax: 905/478-8010 www.pacesettersales.com
Page 5
IMPORTANT NOTICE TO USERS
R
ead Instruction Manual, included with 8000 respirator facepiece, before wearing. You are responsible to under-
s
tand and follow all warnings, restrictions and other information contained in the Instruction Manual. Failure to
do so may result in sickness or death.
USE AGAINST
1. Contaminants specified on NIOSH approval label or bag or cartridges or filters and in Manual.
2. Contaminants with good warning proper ties, i.e. smell, taste or irritation.
DO NOT USE AGAINST
1. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health.
2. Concentrations of contaminants which exceed the maximum use concentration or 10 times the OSHA Permissible Exposure Limit, whichever is lower.
3. Gases or vapors with poor warning proper ties or those which generate high heats of reaction, or paint sprays containing isocyanates, or sandblasting.
4. Oil-based mists with N filters.
WARNING TO USER
1. Follow all instructions and warnings on the use of these cartridges and respirator and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death.
2. For proper use, ask your supervisor or phone 800/421-0668.
3. The user must first be trained by the employer in proper respirator use, in accordance with applicable safety and health standar
4. The vapors, gases, dusts, mists, fumes, and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell.
5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area.
ds, for the contaminant and exposur
e level in the assigned work area.
RESTRICTIONS:
1. This respirator does not supply oxygen and must not be used in atmospheres containing less than 19.5% oxygen.
2. Do not r or nausea.
3. Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or br
4. Do not alter, modify, or abuse the respirator, car tridge and/or filter.
5. Store cartridges, filters and respirator in sealed bag in a clean, dry, non-contaminated area. Dispose of facepiece, an
6.
local regulations.
7. Filters are required for particulates.
8.
Wher
filters for longer than one eight-hour work shift. Dispose no later than eight hours after first use. Do not exceed 10XPEL or a total of 200 mg loading per respirator, whichever is lower. It is the user’s responsibility to know the PEL and concentration of the contaminant, the maximum workrate of the employee, and any other worksite spe­cific information to calculate the loading of the filter. Where oil mists are present do not use N filters.
9.
Where oil mists are not present, dispose of all cartridges, N, R, P filters, no later than thirty days after
first use.
10. Use cartridges, filters, and facepieces before the “use by” expiration date printed on box.
TECHNICAL SER
Moldex maintains a toll-fr contaminants and regulations. If you have any questions call
emain in contaminated area if any physical distress occurs, for example br
d/or cartridges and disks/filters, according to your employer’s policy and
ar
e oil mists
present,
e
VICE LINE
ee Technical Service Line to answer questions about the use of Moldex respirators,
either alone or in combination with solid par
800/421-0668 ext. 550 or Fax 310/837-9563.
eathing difficulty, dizziness
eathing becomes dif
ticulates, do not use the R or P
ficult.
Loading...