Moldex 2370, 2375, 2470, 2475, 2575 Data Sheet

Datasheet
FFP masks
Protection against Dust, Mist & Fumes
Smart Pocket Series
FFP1 NR D
2370 non valved
CHARACTERISTICS
ActivForm
Automatically fits to the face. No manual adjustments by the user are necessary.
DuraMesh
Masks have a strong and durable structure.
Ventex®-valve
Starts to open even at low exhalation pressure and significantly reduces moisture and heat inside the mask.
Nose seal
The flexible nose seal improves fit and provides optimum wearing comfort.
Folded
All qualities of a traditional cup mask but easier to carry around – easy handling with one step unfolding process.
Individually packed
Protected from dust and kept hygienic before use.
Dolomite clogging test
D
NR (non reusable) = Single use. Comfortable and durable throughout the whole shift
Masks have passed the Dolomite clogging test. Better breathing resistance for longer.
100% PVC-FREE
All Moldex products and packaging are completely free from PVC.
®
-valve
®
®
FFP2 NR D
2470 non valved
2475 with Ventex
FFP3 NR D
®
-valve
CERTIFIC ATION
The Moldex Smart Pocket FFP-masks meet the requirements of EN149:2001 + A1:2009 and are CE-marked in accordance with the requirements of European Directive 89/686/EEC. The IFA (0121) Germany is responsible for both type examination (Article 10) and monitoring of production (Article 11). The products are manufactured in an ISO 9001:2000 certified plant.
MATERIALS
Filter Layer, Inner Shell, DuraMesh®: Polypropylene, Ethylene-vinyl acetate (EVA)
Nose Seal: Polyethylene Exhalation valve: Synthetic Rubber, Polypropylene Head Strap: Synthetic Rubber
WEIGHT
2370: 12 g 2375: 16 g 2470: 12 g 2475: 16 g 2575: 18 g
AREAS OF USE
Level WEL Hazard type
Examples
FFP1 4 x FINE DUSTS, FUMES, WATER AND OIL BASED MISTS/
AEROSOLS
Against non-toxic dusts, e.g. Aluminium Oxide, Bauxite, Borax, Brick Dust, Cellulose, Cement, Coal Dust, Gypsum, Limestone, Plaster of Paris, Pollen, Portland Cement, Sucrose, Sugar
FFP2 10 x FINE TOXIC DUSTS, FUMES, WATER AND OIL BASED MISTS/
AEROSOLS
Against toxic dusts, e.g. Aluminium Oxide, Bauxite, Borax, Brick Dust, Cellulose, Cement, Coal Dust, Gypsum, Limes­tone, Plaster of Paris, Pollen, Portland Cement, Sucrose, Sugar, Brake Dust, Calcium Oxide, China Clay, Concrete Dust, Cotton Dust, Granite, Hay, Lead Dust and Fume, Par­ticulate Welding Fumes (no heavy metal), Silica, Sodium Hydroxide, Wood Dust (softwood), Zinc Oxide Fume
FFP3 20 x FINE TOXIC DUSTS, FUMES, WATER AND OIL BASED MISTS/
AEROSOLS
As FFP2 but at higher concentrations, plus: Ceramic Fibres, Chromates, Chromium, Cobalt, Nickel, Micro Organisms, radioactive and biochemical active Aerosols
(WEL = Workplace Exposure Limit)
2575 with Ventex
®
-valve
www.moldex.com
UK - 03 - 2011 / 01
Datasheet
FFP masks
Protection against Dust, Mist & Fumes
Total inward leakage
Ten test subjects perform a variety of exercises. During the exercises the amount of test aerosol that penetrates the filter, face seal and valve are sampled. The total inward leakage of 8 out of 10 test subjects shall not exceed the following levels:
Category FFP1 FFP2 FFP3
max. total inward leakage 22 % 8 % 2 %
INSTRUCTIONS FOR FITTING
The filter penetration after loading the filter with 120 mg paraffin oil according to DIN EN 149:2001 + A1:2009 shall not exceed the following levels:
Category FFP1 FFP2 FFP3
max. Filter penetration 20 % 6 % 1 %
Flammability
4 respirators are passed through a 800°C (+/- 50°C) flame with a speed of 6 cm/s. After passing through the flame the respirator has to self-extinguish.
Breathing Resistance
The breathing resistance produced by the filter of the respirator is tested at an airflow of 30 l/min and 95 l/min.
Category max. breathing resistance
30 l / min 95 l / min
FFP1 0,6 mbar 2,1 mbar
FFP2 0,7 mbar 2,4 mbar
FFP3 1,0 mbar 3,0 mbar
INSTRUCTIONS FOR USE
· The user has to be trained and instructed in wearing the mask.
· FFP masks do not protect against gases and vapours.
· The oxygen concentration of the ambient atmosphere should be at 19,5 % Volume.
· These respirators may not be used if the concentration type, and properties of contaminants in the ambient atmosphere are unknown or at dangerous levels.
· Respirators should be disposed if damaged, if the breathing resistance be­comes high due to clogging, or at the end of a shift.
· Never tamper with, alter or modify the respirator.
1.
2.
3. Place respirator on chin and pull loop over head tight to the neck.
INFO
For help on selection and training please contact us. We offer a wide range of training packages and support material.
4. Pull upper strap and place on back of head.
5. During breaks unclip strap.
6. Let mask hang around your neck.
www.moldex.com
UK - 03 - 2011 / 02
MOLDEX-METRIC AG & Co. KG Unit 9, Glaisdale Point Off Glaisdale Drive, Bilborough Nottingham. NG8 4GP
Tel.: +44 (0)115 985 4288 Fax: +44 (0)115 985 4211 www.moldex-europe.com info@uk.moldex-europe.com