MoistAir MA 0800 0 User Manual

®
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 1
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE.
Model No.
MA 0800 0
TM MC
MA 0800 Evaporative Console Humidifier Owner’s Manual
anihC ni detnirP9956PS.oN traP
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 2
Limited Warranty
All products covered by this Owner’s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years. This warranty does not apply to damage from accident, misuse, alteration, nor where the connected voltage is more than 5% above the nameplate voltage, nor to the equipment or products being improperly installed or wired or maintained in violation of this Owner’s Manual.
THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer or other person is
authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Within the limitations of this warranty, inoperative units should be returned, with a copy of the sales receipt, freight prepaid to an authorized repair service center and the manufacturer will repair or replace the product, at its option, at no charge to the customer with return freight paid by the manufacturer. It is agreed that such repair or replacement is the exclusive remedy available from the manufacturer and that THE MANUFACTURER IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES. Some provinces and
states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply in some cases.
The warranty gives the customer specific legal rights, and the customer may also have other rights which vary from province to province, or state to state.
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR WARRANTY CLAIMS.
GENERAL SAFETY INSTRUCTIONS
Safety Signal
Words
DANGER: means if the safety information
is not followed someone
will be seriously
injured or killed. WARNING: means if the safety
information is not followed someone
could
be seriously injured or killed. CAUTION: means if the safety information
is not followed someone may be injured.
1. To reduce the risk of fire or shock hazard, plug humidifier directly into a 120V, A.C
. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard,
ver put the electric cord under rugs,
ne near heat registers, radiators, stoves or heaters.
3. Always unplug the humidifier before moving it, removing the fan assembly section, before cleaning, or whenever the humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
7. Never use your humidifier while any part is missing or damaged in any manner.
8. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
o reduce the risk of damage to
9. T humidifier, unplug when not in use.
10. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
11.
Note the w
ar
ning label shown below.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.
2
Base
Bottle
Speed & Humidity Controls
B
ottle HandleFan Assembly
Housing Assembly
Filter: Replacement No. MAF2
Humidistat (On Power Cord)
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 3
Know Your Humidifier
Description MA 0800
* Output/24 hrs 8 Gallons/30.2 Litres
Capacity of Bottle 1.2 Gallons/4.54 Litres
Capacity of Base 1.2 Gallons/4.54 Litres
* Sq. Ft. Coverage 1700
Fan Speeds 3
Replacement Filter MAF2
Auto Humidistat Yes
Auto Shut Off Yes
Controls Rubber Feet 6
CUL Listed Yes
Volts 120 A.C.
Hertz 60
Amps (High Speed) 1.2
Watts (High Speed) 81
* Based on an area with average insulation and an 8 foot
ceiling height
Electronic (Push Button)
3
Dry air enters through the louvers in the housing
H
umidified air is
t
hen released
through the top
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 4
How Your Humidifier Works
Your new MoistAIR humidifier is designed
o satisfy home humidity requirements
t through the principle of evaporation of water in the air.
Once the filter becomes saturated, air is drawn in, passes through the filter and moisture is absorbed into the air. All evaporation occurs in the humidifier so any residue remains in the filter. This natural process of evaporation virtually eliminates white dust.
CAUTION: To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier.
To reduce the risk of scalds and damage to humidifier, never put hot water in humidifier.
Step 1. Getting Your Humidifier Up and Running
Once removed from its carton, remove all packing materials. Verify the filter is properly seated (See page 10).
4
At least 2 inches (5 cm) from wall
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 5
Step 2. Location and Electrical Hook Up
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Selecting A Location
Place humidifier on a flat level surface, take extra care in leveling when placing the unit on carpet. Position the humidifier where the most humidity is needed or where the most air will be circulated throughout the house such as near a cold air return.
Moist air (humidity) produced will disperse into the whole house, but the area closest to the unit will have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane. If this occurs the unit should be repositioned in another location.
NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from thermostat and hot air registers and to position humidifier next to an inside wall. Unit should not be placed where cold air from outside walls or warm air from a hot air register blows directly on it.
Positioning The Unit
The humidifier should be positioned with the back (cord exit side) and left side, at least 2 inches (5 centimetres) away from the wall. Air needs to enter through all of the louvers in the housing assembly in order for the humidifier to operate at peak efficiency.
NOTE: Be sure that the humidistat, which is located on the power cord, is free from obstruction and away from any hot air source.
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside wall. With the humidifier in the desired location, route the electrical cord safely so no one will trip or upset the humidifier. Plug in the electrical cord.
WARNING: To reduce the risk of fire or shock hazard, humidifier should be plugged into a 120V A.C. outlet. Do not use extension cords.
To reduce the risk of electrical shock, this humidifier has a polar blade is wider than the other). This plug will fit in a polarized outlet only one way.
ed plug (one
iz
If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
5
Bottle
Base
Spring Valve Assembly
PUSH IN
TURN
CLOCKWISE
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 6
Step 3. Water Fill
ARNING:To reduce the risk of fire
W
or shock hazard, do not pour or spill water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.
After the humidifier is positioned where it will be operating you are ready to fill the humidifier. The bottle lifts straight up and away from the base. Take care not to bump or damage fill valve assembly on the bottom of the bottle.
Invert the bottle. Press the valve stem button into the bottle and turn clockwise to lock in open position. Place bottle under the faucet. Fill the bottle, being careful not to allow any debris to get in the bottle. Debris may interfere with the valve seating. Once the bottle is full, press the valve stem button and turn counter clockwise to release and close.
CAUTION: Use only EPA Registered Bacteriostat. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.
Place the water bottle back into the humidifier base. When positioned properly, the plunger will open and the water will flow into the base. The base will hold the entire contents of the water bottle. Once the bottle is empty, remove it and repeat the filling process. The humidifier is now filled to capacity. To benefit from less frequent filling let the humidifier e the bottle and the base before filling.
xhaust both the water from
6
Function Buttons
Digital Display
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 7
Step 4. Operating the Controls
Where you set your desired humidity levels depends on your personal comfort level, outside temperature and inside temperature. A starting set point of 30% -
ROOM humidity is recommended
40% but there may be conditions that require a different setting.
When Outdoor Recommended Indoor
Temperature is: Relative Humidity is:
-10° F 2° F
10° F
20° F*
-24° C
-18° C
-12° C
-6° C*
20% 25% 30% 35%
IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity
SET
point should be lowered until condensation no longer forms. We recommend room humidity levels do not exceed 50%.
To Operate the Controls
Digital Display
Press the power button once to turn the unit on* . Initially there is a slight delay while the electronics calibrate. Two bars (- -) appear during this time. Once calibration is complete a humidity reading between 20% - 95% will be displayed. A flashing 20 display indicates that the room humidity is less than 20%.
NOTE: The default settings at initial startup are
SET
(LOW) F1 fan speed and 65%
humidity. After desired settings are selected by the user, they remain as long as the unit remains plugged in and there is no power interruption. If the unit is unplugged the
original default settings
are employed.
Humidifier fan should operate at initial start
*
. If it does not, refer to “Fan not operating
up (digital display is illuminated)” in the “Trouble Shooting” section on page 12 of this manual.
ROOM
* and above
7
Humidity Button
Speed Button
Refill Display
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 8
Operating the Controls (cont’d.)
Speed Button
his humidifier is equipped with a
T 3-speed fan control. Initially depressing the speed button will display the current speed setting. Each push of the speed button advances the mode through the settings of
and (LOW) F1.
The selected setting is displayed on the digital readout. The higher the setting, the faster water is evaporated and released into the air. setting and is provided for conditions that do not require a rapid evaporation rate.
(HIGH) F3, (MEDIUM) F2
F1 (LOW) is the quietest
Humidity Control
This button allows you to adjust the humidity to suit your needs. This humidifier will automatically cycle on and off as required to maintain the selected setting. The readout displays both actual and desired (SET) humidity percentage (%) settings when humidity control button is pressed. The range of 20% to 95% RH. If the room humidity level is equal to or less than 20% RH the display will show a flashing 20.
The 65% RH and is adjusted in increments of 5%. Initially depressing the humidity button will display the current humidity setting. button increases the setting by 5%. A SET point of 65% RH operates the humidifier continuously regardless of the ROOM reading. The humidistat that senses the readings is located on the power cord. Insure that it is free from obstruction.
(ROOM)
ROOM readout has a
SET readout has a range of 25% to
Each additional press of the
Using Your Humidifier
Refill Display
For maximum run time both the bottle and the base should be filled. When both the bottle and the base are empty, the display alternates the room humidity reading and additional water is required.
“F” (FILL), informing
8
Check Filter Display
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 9
Check Filter
Indicator
The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter. As the filter loads with impurities it gradually loses its wicking capability. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected setting. This humidifier has a check filter reminder timed to appear after 720 hours of operation. When the display shows an alternating
“CF” and “room humidity”
setting at 5 second intervals it is a reminder to check the filter condition.
NOTE: Some areas have high water mineral content causing the need for more frequent filter changes.
Refer to Replacement and Care of Filter on page 10. If a build-up of deposits or severe discoloration is evident replace the filter to restore maximum efficiency.
umidistat
H
The humidistat located on the power cord senses the percentage of humidity in the air. It causes the humidifier to cycle on and off to maintain the selected humidity
SET point. The fan will turn on if the “ROOM” reading falls 3% below the SET
point and will continue to run the humidifier until a reading of 1% above the SET point is achieved. The fan will turn off until the below the
ROOM reading falls 3%
SET point again.
NOTE:
Be sure that the humidistat, which is located on the power cord, is free from obstruction and away from any hot air source.
9
Grasp housing assembly securely and lift off
Position start and finish of coiled filter at center of base
Align housing assembly bottom with top of base and reposition securely
SP6599-1 MoistAIR 3/29/06 1:13 PM Page 10
Replacement and Care of Filters
Replace the evaporative wicking filter at least once per humidification season or more depending on water conditions in your area.
Filter Replacement
1. Unplug humidifier. Before removing the
2. Remove the water bottle and set aside.
3. Grasp the housing assembly and lift
4. Take note of the filter position. Remove
5. Install a new filter (MAF2) into the
6. Return the housing assembly to the
7. The humidifier is now ready to be filled
ARNING:To reduce the risk of
W
hock or injury from moving parts,
s always unplug humidifier before removing or replacing any parts.
CAUTION: To help retard bacteria growth and keep maximum efficiency, the filter should be replaced at least once per season, or more often under hard water conditions. Use MoistAIR MAF2 recommended replacement filter.
filter, we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage. (i.e. kitchen or bath areas.)
Be sure not to bump or damage the fill valve.
straight up and away from the base and set aside. The filter is now accessible.
the filter.You may want to clean the base at this time. See the "Cleaning and Maintenance" section of this manual.
base. Coil the filter and position it between the uprights in the bottom of the base. The start and finish of the coil should be captured at the center of the base (see diagr filter should be resting on the floor of the base.
top of the base. Reposition the humidifier to its operating position.
for operation.
am) and the
10
Loading...