Moffat Pty Limited Moffat Pty Limited
740 Springvale Road 3/142 James Ruse Drive, Rose Hill
Mulgrave, Melbourne PO Box 913, Smithfield
Victoria 3171 Sydney, N.S.W. 2142
Ph: (03) 9518 3888 Ph: (02) 8833 4111
Fax: (03) 9518 3838 Fax: (02) 8833 4133
Western Australia
Moffat Pty Limited Moffat Pty Limited
67 Howe Street 30 Prosperity Place
Osbourne Park Geebung, Brisbane
WA 6017 Queensland 4034
Ph: (08) 9202 6820 Ph: (07) 3630 8600
Fax: (08) 9202 6836 Fax (07) 3630 8623
Auckland
New South Wales
Queensland
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
Operation Guide
Description of the Controls
Lighting the Pilot Burner - (Target Top)
Lighting the Main Burner - (Target Top)
Lighting the Pilot Burner - (Oven)
Oven - Main Burner / Thermostat
Turning the Oven to ‘Stand-By’ (Pilot ‘ON’ Only)
Oven ‘Shut Down’
Cleaning and Maintenance ...................................................................... 12
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Gas Conversion and Specifications.......................................................... 15
Conversion Procedure
Gas Specifications
Replacement Parts List............................................................................ 20
1
Introduction
We are confident that you will be delighted with your WALDORF Target Top Gas Static Oven Range, , and
it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things
you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
For professional use and is to be used by qualified persons only.
•
Only authorised service persons are allowed to carry out installation,
servicing and gas conversion operations.
•
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user/operator.
•
DO NOT operate the appliance without the legs supplied fitted.
2
Specifications
Model Numbers Covered in this Specification
RN8110G Gas Target Top Static Oven Range.
General
A commercial heavy duty, general purpose fully modular, gas fired Target Top Static Oven Range,
having a high output, two stage double-ring iron cast burner offering accurate temperature control
and infinitely variable heat with the heat radiating out from the centre of the Target Top. The Main
Burner is located underneath removable cast target top plates.
The Target Top is uses a 45 MJ/hr burner and as standard is fitted with full pilot, flame failure
protection.
The Oven utilizes a 30 MJ/hr oven main burner with pilot and flame failure protection and is fitted
with piezo ignition to the oven pilot burner. The oven is controlled with a 80 to 300ºC thermostat.
Access to the oven main and pilot burner is via a drop down door and a removable front lintel on the
lower part of the oven.
The appliance is built to facilitate easy cleaning and maintenance with all parts being front
accessible once the appliance is installed.
* The burner operating pressure is to be measured at the target top hob manifold test point with
the target top burner (Inner and outer ring) operating at full setting. The operating pressure is
ex-factory set through the appliance regulator and not to be adjusted, apart from when carrying
out gas conversion, if required. (Refer to the details in this section for information).
3
Specifications
Gas Connection
Gas supply connection point is located 130mm from the right hand side, 35mm from the rear and
655mm from the floor and is reached from beneath the appliance. (Refer to the ‘Dimensions’
section).
Connection is ¾" BSP male thread.
4
RN8110G
Dimensions
5
Installation
Installation Requirements
NOTE:
• It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local gas and health and safety requirements.
• This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Waldorf Target Top Static Oven Ranges are designed to provide years of satisfactory service and correct
installation is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National Installation Codes and in addition, in
accordance with relevant National / Local Codes covering gas and fire safety.
Australia: - AS 5601 - Gas Installations.
New Zealand: - NZS 5261 - Gas Installation.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by authorised persons only. Failure to install equipment to
the relevant codes and manufacturer’s specifications shown in this section will void the
warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
allowed to be adjusted by an authorised service agent. They are not to be adjusted by the
installation person.
Unpacking
• Remove all packaging and transit protection from the appliance including all protective plastic
coating from the exterior stainless steel panels.
• Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
• Report any deficiencies to the distributor who supplied the appliance.
• Check that the available gas and electrical supply is correct to that shown on the rating plate located
behind the control panel, close to the gas control valve.
Location
1. Installation must allow for a sufficient flow of fresh air for the combustion air supply.
Combustion Air Requirements:
3
Natural Gas 12 m
LPG 12 m
/hr
3
/hr
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Never directly connect a ventilation system to the appliance flue outlet.
4. Any gas burning appliance requires adequate clearance and ventilation for optimum and
trouble-free operation. The minimum installation clearances shown below are to be adhered to.
5. Position the appliance in its approximate working position.
6. All air for burner combustion is supplied from beneath the appliance. The legs must always be fitted
to the appliance and no obstructions placed on the underside or around the base of the appliance,
as obstructions will cause incorrect operation and/or failure of the appliance.
NOTE: Do not obstruct or block the appliance flue. Never directly connect a ventilation system to