Moffat D2HTNG, D3HTSL, D3BM, D3BMSL, D3HT User Manual

...
Page 1
Drop-In
Operating & Service Manual
Manual 001 Issue 011 may 2025
Page 2
and follow all safety, installation and maintenance guidelines carefully before proceeding to install. Keep this manual in a safe place for future consultation.
These appliances are marked in compliance with the relevant
Low Voltage & EMC Directives. Voltage stated on unit data plate.
Warning! Please pay attention to sections of the manual
displaying this symbol.
Warning! Do not attempt to use a hose or water jet to clean this unit. For
cleaning instructions, refer to section 6.
Warning! Depending on your unit model, this unit’s system may be
charged with a flammable refrigerant (R290).
The appliance must only be used for the purpose it was designed for and may become
unsafe if used for any other purpose. Operators should be trained. The room where these units are used must be dry, clean with temperatures between 3°C and 26°C and with a maximum relative humidity of 60%. These units are for indoor use only and have an
IPX4 rating.
Warning! Drop-in units are not designed to be fitted directly into the
top of a hot cupboard.
When hot cupboards are required, a void section must be created in the
counter, The void section must be designed to support the drop-in unit and allow a Moat “Roll Under” hot cupboard to be sited in the space underneath.
The Ambient temperature around the bottom of the Drop - units must not exceed 55°c (where the electrics are located)
Page 3
Contents
Page
1
2
2.1
2.2
2.3
2.4
3
3.1
3.2
4
4.1
4.2
5
5.1
5.2
6
6.1
6.2
7
7.1
7.2
Electrical Specification
General Installation
Method Cut-Out Dimensions Refrigerated Vent Dimensions Additional Operation Conditions
Hot Top
Specification Operation
Bain-marie Dry Heat
Specification Operation
Bain-marie Wet Heat
Specification Operation
Heated display
Specification Operation
Refrigerated Units
Specification Operation
4
5
6 / 7
8 / 9
10 / 11 / 12 / 13
14 / 15 / 16 / 17 / 18 / 19
20
21
22
23 24 25
26
27 / 28 / 29 / 30
31
32
33 / 34 / 35 / 36
37 / 38
8
8.1
8.2
9
9.1
9.2
10
10.1
10.2
11
12
Plate Dispensers
Specification Operation
Universal Crockery Dispenser
Specification Operation
Soup Station
Specification Operation
Cleaning
Changing Lights
39
40 / 41 / 42 / 43 / 44
45
46 / 47 / 48
49 49
50 / 51
52 / 53
3
Page 4
1: Electrical Specification
This appliance must be earthed and damaged cables must be
replaced by a suitably qualified person!
1: Electrical Specification
Live (L1)
L2
L3
Neutral
Earth
1 Phase Cable
Brown
X
X
Blue
Yellow & Green (Striped)
A mains cable, type H07RN-F, conforming to code designation 60245 IEC 57, is supplied.
3 Phase Cable
Brown
Black
Grey
Blue
Yellow & Green (Striped)
4
Page 5
2: General Installation
2: General Installation
Before installation please read the following points:
• When designing the counter body ensure there is adequate access.
• The counter top must be perfectly level before the drop-in units are installed.
• It is advisable to protect the counter top surface with thick card, hardboard, thin plywood sheet or similar, to avoid accidental damage during positioning.
• Each drop-in is secured to the counter top with a continuous bead of silicon sealant between the unit & work surface.
• An adequate amount of personnel (or lifting gear if available) should be used, to avoid any risk of injury or damage to equipment.
• Before installing, it is recommended that the work top is protected & all loose items are removed from unit to aid handling i.e. Glass screens, canopies, etc.
This equipment is designed to be operated by suitably qualified
persons. It is the responsibility of the Supervisor or equivalent to instruct users, provide suitable P.P.E., show the mains isolating switch location, and inform users that parts may become hot, causing injury if touched.
1. Remove all packaging & plastic coatings from the appliance. Check for any damage.
2. Assemble all parts, including shelves, food containers etc.
3. Bain-marie Dry Well: Ensure that the heater is located correctly and plugged in.
4. Heated units: Fit the supplied halogen bulbs to the holders under the gantry.
5. Ensure all switches and thermostat controls are in the OFF position.
6. Connect the mains input plug to the socket outlet.
7. Turn on and check the unit is functioning correctly.
5
Page 6
2: General Installation
2.1: Method
• Drop-In units are designed for installation using the minimum of tools.
• They can be installed into any type of counter body so long as the carcass construction is strong enough to support their weight.
• Drop-In models require a bed of sealant to fix them in place.
• All models require a cut out in the top of the counter body. Therefore, a void or empty cupboard directly under the Drop-in should be allowed for.
6
Page 7
Surface Mounted
2: General Installation
Flush with Surface
7
Page 8
2: General Installation
2.2: Cut-out Dimensions
Depending on the type of counter top material. Installers may choose to cut-out the proposed hole on-site. Use the table below to establish & mark out the correct cut-out size of your chosen drop-in model. Alternatively, CNC operators can use the table when preparing materials that can only be machined o site (i.e. Stone, metal, etc.).
Note: When laying out the cut-out position, care should be taken to make sure the ‘drop-in’ body does not foul the inside of the unit carcass under.
For a flush fit, the routed out edge provides a 3mm gap to seal with..
Standard Dimensions
8
Page 9
Soup Station
Plate Dispenser
2: General Installation
Universal Crockery Dispenser
9
Page 10
2.3: Air Vent Cut-Out Dimensions
All Size 2 Refrigerated Units
(D2RD Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
10
Page 11
All size 2 units with back to wall
(D2RDFC Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
11
Page 12
All size 3, 4 & 5 refrigerated units
(D3RD Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
(D4RW Illustrated)
12
Airflow direction
Page 13
All size 3, 4 & 5 refrigerated units with back to wall
(D3RDFC Illustrated)
2.3: Air Vent Cut-Out Dimensions
(D4RW Illustrated)
13
Page 14
2.4: Refrigerated Units Additional Operation & Installation Conditions
To ensure the satisfactory operation and optimum eciency of this unit, it is
imperative that the ambient room conditions where the units are being used do
not exceed a room temperature of 25°c or exceed a relative room humidity of 60%.
Should conditions exceed the above, the display units may not maintain food temperatures at the required levels. E&R Moat cannot accept responsibility for the performance of the units being used in extreme conditions.
Do not:
• Install units where there is high radiated heat, e.g. direct sunlight, room heaters, or bright spot lights
2: General Installation
• Install units in draughty conditions where the air movement is greater than 0.2mtr/sec. (e.g. near doors, windows, air conditioning units or fans].
When installing these refrigerated units, allowances must be made for air venting. It is
crucial that there is an unrestricted air flow through the under slung compressor and condensing coil.
Proper venting must be provided ensuring cool air from the room can be pumped in through the condensing coil and out the other side.
The hot air blown out from the opposite side ‘must not’ be allowed to be sucked back through the condensing coil [see image on page 15].
Air Flow (see image on page 15) provides a general understanding
of the compressor airflow through our standard refrigerated Drop­in compressor housing. Do not let the warm expelled air from the compressor recycle directly back through the Condensing coil.
14
Page 15
2: General Installation
15
Page 16
Where the drop-in requires boxing in the ‘Plenum Duct’ supplied should be fitted to fill in the void between the drop-in body & the shop-fitted counter panels.
Blocked vents will cause reduced eciency and lead to malfunction:
2: General Installation
Plenum Duct in Si-tu, a ‘plenum duct’ will be required in certain situations to stop expelled air from the compressor being directly recycled into the
coil vent. This box should be fitted to suit the gap between drop-in and the counter panel.
16
Page 17
2: General Installation
Vent Grill Installation
Drop-in units are designed to slot into a pre-fabricated
counter that’s open to the rear (Operators Side), to allow a free circulation of air through the compressor housing. If the design of the counter dictates the rear to be panelled o, remove the two vent grills that are factory fitted and relocating them onto the shop-fitted rear panel (By others). The ’plenum duct’ would need to be fitted, to fill in the void behind the panel.
1. Remove the two Vent panels from the compressor housing.
2. Referring to the diagrams on pages 10 & 13, mark and cut out the vent holes.
3. Referring to the dimensions on the diagram below, mark out the centre hole for both vent brackets make sure there is an even overhang top & bottom of the vent cut-out.
4. Drill a pilot hole & secure brackets using
17
Page 18
1/2” (12mm) x 8 pan head screws or similar.
5. Drill pilot holes for the four remaining top and bottom bracket fixings, & secure.
6. Oer up the Vent Grill on to the brackets and secure using the machine bolts provided.
2: General Installation
The vent grill can be removed, providing access to clean the compressor coil.
Lifting Unit into Position
Two lifting tubes are supplied with each unit. These tubes should be used when moving or lifting the unit into position. Lifting eyes are also supplied and are designed to be temporarily fitted on each corner of the display well to aid lifting into position and must be removed after installation is complete.
• First remove the perspex screen.
• Fit the lifting plates using the screws located on each corner of the well
• Slide each lifting tube through a set of lifting eyes,one at each end of the unit.
• Lift into position using the lifting tubes supplied.
• Allow an even amount of tube to protrude from each side (800mm Approx.)
• This will provide enough room for two people to get a comfortable grip at each corner. Consult the
unit specifications to decide on the number of people needed to lift the unit, approximately 25Kg
18
per person is
recommended.
• Check your own company’s health and safety policy before attempting to lift. Alternatively, a
small portable lifting hoist can be used to lift the unit. Pass lifting ropes through the lifting eyes
taking care not to cut or damage the ropes.
• When the unit has been lowered into place remove lifting eyes.
• Remove tubes and remove the lifting plates.
• Replace the screws and refit the perspex screen.
Page 19
Lifting Unit into Position
Lifting Plate Temporarily fit to each corner of the well
2: General Installation
Remote Control Box Cut-out Dimensions (for units with no gantry fitted)
The control box is designed to be fitted on a counter side panel.
0
.
5
8
• The cut out dimensions for the box are 185mm x 120mm
• Fixing holes are on163mm centres
200.0
5
.
7 6
0
.
5 3
1
5
.
7 6
0
.
5
1
1
163
19
Page 20
3: Hot-Top:
Specifications
Model
D2HTNG D3HTNG D4HTNG D5HTNG
D2HT D3HT D4HT D5HT
D2HTF D3HTF D4HTF D5HTF
D2HTSL D3HTSL D4HTSL D5HTSL
D2HTSLF D3HTSLF D4HTSLF D5HTSLF
D2HTD D3HTD D4HTD D5HTD
D2HTDSL D3HTDSL D4HTDSL D5HTDSL
Weight
(kg)
18
24
31
39
24
31 39 48
36 46 57 68
30
40
51 63
38 48
59
71
34 46
57
68
38 48
59
71
Length
x Depth
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
Height
above
display top
0 0 0 0
408 408 408 408
408 408 408 408
396 396 396 396
396 396 396 396
540 540 540 540
540 540 540 540
No.
of
180w
Neo
Ceram
Hot
Plates
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
No of 220w lamps
N/A N/A N/A N/A
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Electrical
Supply
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
Hot-Top
Power Rating
(kw)
0.36
0.54
0.72
0.90
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
20
Page 21
Operation
Hot-Tops are designed to keep pre-cooked food at serving temperature and are suitable for the display of most types of hot foods. They are fitted with easy to clean Neo-Ceram thermo panels Their energy regulated surface temperature is controlled at around 90°.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, and quantity. Flat base dishes are recommended to allow best heat transfer.
The Hot Top & Gantry are both controlled by a green neon on/o switch and energy regulating control knob.
Hot-Top
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch
3. Turn Control Knob to position 3 [Full Power]
4. Leave for 15mins to reach serving temperature
5. Set the temperature of the Hotplate to the desired position (Control range between 1-3 with 3 being full power).
6. Dishes with ‘precooked’ food can now be loaded.
7. When serving is complete all switches should be turned o.
8. To maintain the life clean regularly with a damp cloth.
21
Page 22
4: Bainmarie Dry Heat:
Specifications
Height
Model
D2BMNG D3BMNG D4BMNG D5BMNG
D2BM D3BM D4BM D5BM
D2BMF D3BMF D4BMF D5BMF
D2BMSL D3BMSL D4BMSL D5BMSL
D2BMSLF D3BMSLF D4BMSLF D5BMSLF
D2BMD D3BMD D4BMD D5BMD
D2BMDSL D3BMDSL D4BMDSL D5BMDSL
Weight
(kg)
23 29 36 44
30 38
47
57
38
47
57 68
36
47
59
71
44
55
67
79
40
52
65
76
44 54
67
79
Length
x Depth
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
above
display top
13 13 13 13
408 408 408 408
408 408 408 408
396 396 396 396
396 396 396 396
540 540 540 540
540 540 540 540
GN 1/1
Capacity
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
No of 220w lamps
N/A N/A N/A N/A
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Bainmarie Dry Heat
Electrical
Supply
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
Power Rating
(kw)
0.9
1.5
1.5
1.9
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
22
Page 23
Bainmarie Dry Heat
4: Bainmarie Dry Heat:
Operation
Bain-marie units are designed to keep pre-cooked food at serving temperature and are suitable for the display of most types of hot foods, complete with an inset well designed to accommodate various combinations of interchangeable Gastronome type pans up to 150 mm deep. Each opening can also be fitted with an optional spiked carvery pad or Neo-Ceram Hot Top adaptor.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, amount of food in container, etc. Fit empty pans and lids into their openings before switching the unit on. After the 30mins has elapsed load food and replace lids. Do not remove lids until service is due to commence.
The Bain-marie & Gantry are both controlled by a green neon on/o switch and a digital temperature control.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch
3. Digital illuminates and controls the Bain-marie well temperature
4. Leave for 30mins to reach serving temperature
5. Set the temperature of the Bain-marie to the desired position (Factory set at 95° adjustable between 80° and 100°].
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
To maintain the life clean regularly with a damp cloth.
23
Page 24
How to Change the Temperature Setting
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature set-point
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm, or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change will be cancelled.
the action
24
Page 25
The Dry heat Bain-marie well incorporates an innovative fan assisted heating unit. This compact heating unit is removable for easy cleaning and maintenance.
There are two hot air distribution channels - one on either side of the fan. Note: The smaller Size 2 units have the Fan only.
A
Hot Air Distribution channels (Take hold of channel and lift upwards)
B
Sahara Fan (Take hold of casing and lift upwards) Replacing both items is a reversal:
Bainmarie Dry Heat
These units will remain hot for a long period of time after use. Air flow vents must not be blocked.
• The 4 clear arrows represent air entering the Sahara fan ‘B’
• The Black arrows show the regenerated hot air being evenly distributed
25
Page 26
5: Bainmarie Wet Heat:
Specifications
Height
Model
D2BMWNG
D3BMWNG
D4BMWNG
D5BMWNG
D2BMW
D3BMW
D4BMW
D5BMW
D2BMWF
D3BMWF
D4BMWF
D5BMWF
D2BMWSL
D3BMWSL
D4BMWSL
D5BMWSL
D2BMWSLF
D3BMWSLF
D4BMWSLF
D5BMWSLF
D2BMWD
D3BMWD
D4BMWD
D5BMWD
D2BMWDSL
D3BMWDSL
D4BMWDSL
D5BMWDSL
Weight
(kg)
27
35 44 54
34
44
55
67
44
53 65 78
40
53
67
81
48
61
75
89
44
58
76
86
48 60
75
89
Length
x Depth
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
above
display top
408 408 408 408
408 408 408 408
396 396 396 396
396 396 396 396
540 540 540 540
540 540 540 540
13 13 13 13
GN 1/1
Capacity
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
No of 220w lamps
N/A N/A N/A N/A
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Bainmarie Wet Heat
Electrical
Supply
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
13amp
16amp 32amp 32amp
Power
Rating
(kw)
2.0
3.0
4.0
5.0
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
26
Page 27
Bainmarie Wet Heat
Operation
Bain-marie units are designed to keep pre-cooked food at serving temperature and are suitable for the display of most types of hot foods, complete with an inset well designed to accommodate various combinations of interchangeable Gastronome type pans up to 150 mm deep. Each opening can also be fitted with an optional spiked carvery pad or Neo-Ceram Hot Top adaptor.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, amount of food in container, etc. Fit empty pans and lids into their openings before switching the unit on. After the 45mins has elapsed load food and replace lids. Do not remove lids until service is due to commence.
This a wet heat only unit. The heating elements must always be fully immersed in water. Before switching on fill with water up to the level mark and make sure the drain valve is in the closed position.
Filling and maintaining the water level refer to page 29.
The Bain-marie & Gantry are both controlled by a green neon on/o switch and a digital temperature control.
1. Connect plug and switch on at mains outlet
2. Power on with green illuminated Switch
3. Digital illuminates and controls the Bain-marie well temperature
4. Leave for 45mins to reach serving temperature
5. Set the temperature of the Bain-marie to the desired position (Factory set at 95° adjustable between 80° and 100°]
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
27
Page 28
How to Change the Temperature Setting
Bainmarie Wet Heat
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature set-point
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm, or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change will be cancelled.
the action
28
Page 29
Filling the Well
1. First check the drain valve is fitted correctly and in the closed position.
2. Carefully fill well with warm water (if available) up to the water level mark.
3. Fit empty pans and lids into their openings before switching the unit on.
4. Leave for 45mins to reach serving temperature
Low Water Level Sensor
This Wet Well Bain-marie is fitted with a low water sensor, which sends a flashing ‘Al’ message to the display on the digital controller when the water level falls below an acceptable level.
If this message appears, [ “flashing” AI ]:
Bainmarie Wet Heat
1. Switch o the green mains switch.
2. Immediately refill with water up to the water level mark.
3. Switch power back on using the green mains switch.
4. The digital control will reset and continue to control the temperature.
If the water level is left to fall below the heating element, premature failure of the heating element may result.
29
Page 30
Draining the Well
1. Switch o & disconnect unit from mains power.
2. Wait until water cools down to room temperature.
3. Open drain valve & fill container.
4. Switch o valve & empty container when full in a suitable place.
5. Repeat until well is empty.
6. Close drain valve.
Bainmarie Wet Heat
30
These units will remain hot for a long period of time after use.
If required to top up the water level in mid service, use suitable heat insulated gloves when removing the hot Bain Marie containers.
Page 31
6: Heated Display: Specifications
No. of Display Shelves
3 3
3 3
3 3
3 3
Model
D2HD
D3HD
D2RDF
D3RDF
D2RDSL
D3RDSL
D2RDSLF
D3RDSLF
Weight
(kg)
66 87
66 87
66 87
66 87
Length
x Width
(mm)
830 x 660 1158 x 660
830 x 660 1158 x 660
830 x 660 1158 x 660
830 x 660 1158 x 660
Height
above
display top
750 750
750 750
750 750
750 750
6: Heated Display: Operation
Electrical
LED Roll
Ilumination
Yes Yes
Supply
13amp 13amp
Yes Yes
Yes Yes
13amp 13amp
13amp 13amp
Yes Yes
13amp 13amp
Power Rating
(kw)
1.05
1.50
1.05
1.50
1.05
1.50
1.05
1.50
Designed to keep pre-cooked food at serving temperature and are suitable for the display of most types of hot foods. Heated shelves have a removable perforated adaptor for use when less direct heat form the shelves is requiered such as bread products rolls and sandwiches.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, quantity and packaging, etc. The Display unit is controlled by a green neon on/o switch and a digital temperature control.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch.
3. Digital illuminates and controls the display temperature.
4. Leave for 30mins to reach serving temperature.
5. Set the temperature of the display to the desired position (Factory set at 80° adjustable between 60° and 95°]
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
To maintain the life clean regularly with a damp cloth.
31
Page 32
6: Heated Display: Operation
How to Change the Temperature Setting
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature setpoint
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm, or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change will be cancelled.
• Hot display units, bain-maries, and hot tops, are designed to hold pre-heated food products at regulated temperatures in an ambient room temperature above 16°C.
• Consideration should be made when sighting to avoid positioning
close to air conditioning vents, windows and doors where cold draughts may be present. (Food temperature and quality may be aected).
the action
32
• Do not install units in draughty conditions where the air movement is greater than 0.2mtr/sec
Page 33
7: Refrigerated Well:
Specifications
NOTE: Island models with double sided curved glass screens have an “ I “ added to the code.
Length
Model
D2RWNG D3RWNG D4RWNG D5RWNG
D2RW D3RW D4RW D5RW
D2RWF D3RWF D4RWF D5RWF
D2RWSL D3RWSL D4RWSL D5RWSL
D2RWSLF D3RWSLF D4RWSLF D5RWSLF
D2RWD D3RWD D4RWD D5RWD
D2RWDSL D3RWDSL D4RWDSL D5RWDSL
Weight
(kg)
67 76 85 93
74 85 95
105
82
94
105
116
74 85 95
105
82 94
105
116
78
91
102
115
82 94
105
117
x Depth
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
display top
Height
above
25 25 25 25
408 408 408 408
408 408 408 408
396 396 396 396
396 396 396 396
540 540 540 540
540 540 540 540
GN 1/1
Capacity
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
LED Roll
Illumination
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Refrigerated Units
Electrical
Supply
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
Power
Rating
(kw)
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
33
Page 34
Refrigerated Units
7: Refrigerated Display [2 Shelf]: Specifications
Model
D2RDL
D3RDL
D4RDL
D5RDL
D2RDLF
D3RDLF
D4RDLF
D5RDLF
D2RDLFC
D3RDLFC
D4RDLFC
D5RDLFC
D2RDLSA
D3RDLSA
D4RDLSA
D5RDLSA
D2RDLSL
D3RDLSL
D4RDLSL
D5RDLSL
D2RDLSLF
D3RDLSLF
D4RDLSLF
D5RDLSLF
D2RDLSLFC
D3RDLSLFC
D4RDLSLFC
D5RDLSLFC
Weight
(kg)
114
134
151 171
122
143
161
182
104
119 131
157
119 140 158
179
116
137 155 176
124 146 165
187
114
131 145
162
Length
x Depth
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
Height
above
display top
540 540 540 540
540 540 540 540
540 540 540 540
645 645 645 645
645 645 645 645
645 645 645 645
645 645 645 645
No. of Display Shelves
2 2 2 2
2 2 2 2
2 2 2 2
2 2 2 2
2 2 2 2
2 2 2 2
2 2 2 2
LED Roll
Ilumination
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Electrical
Supply
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
Power Rating
(kw)
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
34
Page 35
Refrigerated Units
7: Refrigerated Display [3 Shelf]: Specifications
Model
D2RD
D3RD
D4RD
D5RD
D2RDF
D3RDF
D4RDF
D5RDF
D2RDFC
D3RDFC
D4RDFC
D5RDFC
D2RDSA
D3RDSA
D4RDSA
D5RDSA
D2RDSL
D3RDSL
D4RDSL
D5RDSL
D2RDSLF
D3RDSLF
D4RDSLF
D5RDSLF
D2RDSLFC
D3RDSLFC
D4RDSLFC
D5RDSLFC
Weight
(kg)
124
149
171
196
132
158
181
207
114
134
151
182
129 155 178
204
126 152 175
201
134
161
185
212
124
146
165 187
Length
x Width
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
Height
above
display top
750 750 750 750
750 750 750 750
750 750 750 750
855 855 855 855
756 756 756 756
756 756 756 756
756 756 756 756
No. of Display Shelves
3 3 3 3
3 3 3 3
3 3 3 3
3 3 3 3
3 3 3 3
3 3 3 3
3 3 3 3
LED Roll
Ilumination
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Electrical
Supply
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
Power
Rating
(kw)
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
35
Page 36
7: Refrigerated Frost Top: Specifications
NOTE: Island models with double sided curved glass screens have an “ I “ added to the code.
Height
Model
D2FTNG
D3FTNG
D4FTNG
D5FTNG
D2FT
D3FT
D4FT
D5FT
D2FTF
D3FTF
D4FTF
D5FTF
D2FTSL
D3FTSL
D4FTSL
D5FTSL
D2FTSLF
D3FTSLF
D4FTSLF
D5FTSLF
D2FTD
D3FTD
D4FTD
D5FTD
D2FTDSL
D3FTDSL
D4FTDSL
D5FTDSL
Weight
(kg)
50 60 70 80
60 70 85 90
70 80 95
105
60 70 85 95
70 85 95
105
70
75 85 95
70 80 90
105
Length
x Width
(mm)
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
830 x 660 1158 x 660
1486 x 660
1814 x 660
above
display top
25 25 25 25
408 408 408 408
408 408 408 408
396 396 396 396
396 396 396 396
540 540 540 540
540 540 540 540
GN 1/1
Capacity
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
2 3 4 5
LED Roll
Illumination
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Refrigerated Units
Electrical
Supply
Power Rating
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
13amp 13amp 13amp 13amp
(kw)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
36
Page 37
Refrigerated Units
Operation
Warning! This unit’s system is charged with a flammable refrigerant (R290).
Before commencing there are certain environmental parameters that must be followed please read the additional installation
conditions on page 14.
Refrigerated display units are designed to keep pre-chilled food at a regulated serving temperature and are suitable for the display of most types of cold food. Designed to provide a gentle flow of cold air maintaining a safe and compliant temperature within. The Chilled display has an automatic defrost, and automatic condensate water evaporation system, eliminating the need to manually empty drip trays or install on-site drainage.
The controlled air temperature is factory set to
operate between 2° and 5°.
To enable automatic condensate evaporation, the 13A plug must be constantly switched on.
The green switch can be switched o when the cooling is no longer required, however, do not unplug the unit from the mains power. The Display unit is controlled by a green neon on/o switch and a digital temperature control.
37
Page 38
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch.
3. Digital illuminates and controls the display temperature.
4. Allow 30mins for the display too cool down before loading product.
5. The controlled air temperature is factory set to operate between 2° and 5°.
6. Defrost is factory set
7. When serving is complete all switches should be turned o.
These units require good airflow inside and outside.
It is essential the vents in the external panels do not become blocked as this can cause the unit to fail, due to overheating. Internally good air flow must also be maintained, a small space should be left between all products.
38
Page 39
8: Plate Dispenser: Specifications
Length
Model
DUP1 DUP2
DHP1 DHP2
Weight
(kg)
15
27
16
28
x Depth
(mm)
400 x400 400 x 740
400 x400 400 x 740
Height
above
display top
150 150
150 150
Capacity
65
2 x 65
65
2 x 65
No of 220w lamps
N/A N/A
N/A N/A
Electrical
Supply
N/A N/A
13amp 13amp
Plate Dispenser
Power
Rating
(kw)
N/A N/A
0.6
1.2
8: Plate Dispenser: Operation
In-counter spring-loaded pop-up plate dispensers Single or twin plate dispensers, in both ambient & heated formats.
• Adjustable guides to suit 8” - 12” (203mm - 305mm) diameter plates.
• Variable spring system to accommodate dierent plate weights.
• Each tube can take a maximum of 65 plates (Depending on type of plate used).
Heated Models:
• Thermostat controlled internal air temperature approximately 60°.
• Complete with ergonomic black ABS plate cover.
• Supplied with a 2-meter cable fitted with a 13-amp moulded plug for easy installation.
39
Page 40
Operation:
• Load the Tube & cover plates with the supplied black ABS plate cover.
• Switch on the unit using the green switch.
• Allow approximately 60min to warm the plates before serving.
• When serving; remove the top plate & the plate below will automatically pop up
• Keep lid in place whenever possible during service
Never discard the lid. The lid holds the heat inside maintaining an even temperature. if the lid is left o for extended periods the heating will not control the temperature properly and the bottom plates could become too hot and damage to the elements may occur.
Plate Dispenser
• Allow all heated units to cool after service before cleaning. (Cleaning instructions are given on page 52).
40
Page 41
Plate Dispensers Additional Setting Up And Commissioning
The element on the heated units will remain hot for a period after use. Care should be taken to avoid injury.
Setting the Plate Diameter Using one plate only set the guides to their correct positions for the size of plate.
All 4 guides must be set to the same position/number
Plate Dispenser
Plate Diameter
8” (203mm) 9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Plate Guide Position
8 9
10
11
12
41
Page 42
Setting the Spring Tension Plates sits on a removable Plate Base Support which in turn rests on a floating platform. This ‘Floating Platform’ in turn, is supported by several tension springs.
The tension springs are fastened symmetrically on two sides.
In order to access the tension springs the Plate Base Support needs to be removed.
1. Pull up the spring loaded ‘Plate Guides and swivel anticlockwise to their extreme outer positions & lower down again for them to lock into their ‘service’ positions.
Plate Dispenser
42
Page 43
2. Lift ‘Plate Base’ straight upwards until the location tabs on the underside are fully removed from the ‘Floating Platform’ slots.
Plate Dispenser
3. The ‘Floating Platform’ is supported by an equal amount of tension springs on each corner. The number of springs equates to the size of plate being used.
Use the chart below as a starting point; add or remove springs accordingly (in groups of four, one each corner), until the top plate is at the required serving level)
The Springs are held in place using a hook & eye arrangement top & bottom. They can be easily attached or detached by just hooking or unhooking the end in to or out of the corresponding hole on the Floating support Arm.
There must be an equal amount of springs on all four corners. The four
corner springs should not be removed. When removing springs, start from the centre outwards. When adding springs work from the corners inwards. Keep the spring numbers symmetrical whenever possible.
43
Page 44
Plate Dispenser
Plate Diameter
8” (203mm) 9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Below shows the Plate lift set up for the weight of 9” Plates. Only the 3 outer springs are attached to each corner of the Floating Platform. The 3 inner springs on the left, are shown in their storage position. [hook on top only]
Number of Springs on
Each Corner
2 3
4
5 6
Total Number of Springs
8 12 16
20 24
44
Page 45
9: Universal Crockery Dispenser Specifications
Height
Model
DHD1 DAD1
Weight
(kg)
13
11
Length
x Depth
(mm)
420 x 345 420 x 345
above
display top
30 30
Capacity
65 65
No of 220w lamps
N/A N/A
Universal Crockery Dispenser
Electrical
Supply
13amp
N/A
Power
Rating
(kw)
0.6
N/A
Universal Crockery Dispenser: Operation
In-counter spring-loaded pop-up plate dispensers. Single tube in both ambient & heated formats. Ideal for oval, round & square crockery including bowls up to 305mm (12”). bowl capacity may be less depending on the type.
• Adjustable guides to suit 8” - 12” (203mm - 305mm) diameter plates.
• Variable spring system to accommodate dierent plate weights.
• Each tube can take a maximum of 65 plates (Depending on type of plate used).
Heated Models:
• Thermostat controlled internal air temperature approximately 60°.
• Complete with ergonomic Stainless-Steel lid.
• Supplied with a 2-meter cable fitted with a 13-amp moulded plug for easy installation.
45
Page 46
Operation:
• Load the Tube & cover plates with the supplied Stainless-Steel lid.
• Switch on the unit using the green switch.
• Allow approximately 60min to warm the plates before serving.
• When serving; remove the top plate & the plate below will automatically pop up.
• Allow all heated units to cool after service before cleaning.
Universal Crockery Dispenser
46
The element on the heated units will remain hot for a period after
use. Care should be taken to avoid injury.
Page 47
Universal Crockery Dispenser
Setting the Spring Tension Plates sits on a removable Plate Base Support which in turn rests on a floating platform. This ‘Floating Platform’ in turn, is supported by several tension springs. The tension springs are fastened symmetrically on two sides.
In order to access the tension springs the Plate Base Support needs to be removed.
1. Remove lid & store in safe place.
2. Lift out plate/bowl carriage & store in safe place.
3. Unscrew the 4 bolts which secure the two inner panels and remove.
4. Adjust the springs (refer to page 49).
5. Relocate the inner panels. 2 Tabs on the bottom 2 screws on the top of each.
47
Page 48
Universal Crockery Dispenser
6. The ‘Floating Platform’ is supported by an equal amount of tension springs on each corner. The number of springs equates to the size of plate being used. Use the chart below as a starting point; add or remove springs accordingly (in groups of four, one each corner), until the top plate is at the required serving level).
The Springs are held in place using a hook & eye arrangement top & bottom. They can be easily attached or detached by just hooking or unhooking the end in to or out of the corresponding hole on the Floating support Arm.
The element on the heated units will remain hot for a period after
use. Care should be taken to avoid injury.
Plate Diameter
8” (203mm) 9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Number of Springs on
Each Corner
2 3
4
5 6
Total Number of Springs
8 12 16
20 24
48
Page 49
10: Soup Station
Soup Station
Specifications
Height
Model
D1SDT D2SDT
Weight
(kg)
5
8
Length
x Depth
(mm)
300 x 455
550 x 455
above
display top
70 70
Capacity
1x 4lt 1x 4lt
No of 220w lamps
N/A N/A
Electrical
Supply
13amp 13amp
Power
Rating
(kw)
0.35
0.70
Soup Station: Operation
Along with a removable drip tray which aids cleaning, they also come supplied with the appropriate amount of 4,5litre stainless steel pots, complete with stainless steel lids. Controls are surface mounted for convenience, and consist of an neon power indicator and an energy regulator dial.
The correct serving temperature is dependent on the food type / amount etc.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Fit empty pans and lids into their openings
3. Power on with green illuminated Switch
4. Turn control Knob to position No 110.
5. Leave for 30mins to reach serving temperature.
6. Set the Knob to the desired position. (around 90 will keep soup warm].
7. Precooked Soup can now be loaded.
8. Do not remove lids until service is due to commence.
9. When serving is complete all switches should be turned o.
10. To maintain the life clean regularly with a damp cloth.
These units are not designed to heat up cold food.
1. Precooked Soup can now be loaded.
2. Do not remove lids until service is due to commence.
3. When serving is complete all switches should be turned o.
4. To maintain the life clean regularly with a damp cloth.
49
Page 50
11: Cleaning
11: Cleaning
Before attempting to clean the unit, please ensure that the Unit is isolated from the electric supply and allowed to cool down, with all food plates and other Dishes removed from the unit.
Do not use a water jet or pressure spray to clean this appliance.
1. Disconnect trolley from mains and wait until appliance has cooled.
2. Wipe clean using hot, soapy water and soft, non-abrasive cloth. Ensure that the stainless steel is wiped in straight strokes following the grain of the material.
3. Wipe dry using a clean cloth. Do not use scouring pads or abrasive cleaners of any type. Shelving and select inner panels can be removed to allow a deeper internal clean. Ensure all panels and fixings are replaced after cleaning operation.
4. Refrigeration compartment should be washed and then dried with a cloth after each service.
5. The chilled well has removable base sections for easy cleaning and maintenance. They should be removed periodically and the area beneath wiped clean.
6. The drain hole must also be kept clear from blockage.
7. Wipe down sneeze screen and glass top with a damp, clean cloth.
8. Finish by carefully drying with a soft dry cloth or Kitchen Towels.
Do not use scouring pads or abrasive cleaners of any type.
Do not use Solvents, bleach, Caustic Cleaners or biological powders on any surface.
50
Special care should be taken around electrical parts, avoided excessive use of water.
Take special care when cleaning glass use a soft duster & glass cleaner spray.
Page 51
The condensing coil & vents requires regular cleaning to maintain the performance of the unit, as air borne particles will choke the coils fins. They should be cleaned with a soft brush and vacuum.
11: Cleaning
51
Page 52
12: Quartz Lamp Replacement
Ensure appliance is disconnected from mains before servicing.
Lamps should not be touched with bare hands, as this may cause premature failure. If lamp is touched, wipe clean with a cloth and alcohol prior to use.
Replacement quartz lamps must never exceed the loading specified.
Wear safety glasses.
Don’t touch hot halogen bulbs.
Only use replacement bulbs that match the wattage and design of the fixture.
12: Quartz Lamp Replacement
1. Isolate appliance from power supply and allow cooling
down before commencing lamp replacement.
2. Carefully slide mesh guard to one side until it clears the bulb area.
52
Page 53
3. Remove faulty lamp by pushing to one side then pull down. Hold the insulated end of the new lamp (Any end).
4. At a slight angle, slot the end of the new lamp into one of the Housing
5. Push against the sprung contact & hold it there.
6. Raise the opposite end of the lamp into the other end of the Lamp.
12: Quartz Lamp Replacement
Each replacement Quartz lamp must never exceed 220W.
53
Page 54
Thank you for choosing E&R Moat!
Scan the QR code below to visit the
E&R Moat website for further information:
E&R Moat Ltd. Bonnybridge FK4 2BS Scotland
www.ermoat.co.uk
+44 (0) 1324 812272
sales@ermoat.co.uk
Loading...