To ensure the best results from this unit please take the time to read
and follow all safety, installation and maintenance guidelines carefully
before proceeding to install. Keep this manual in a safe place for future
consultation.
These appliances are marked in compliance with the relevant
Low Voltage & EMC Directives. Voltage stated on unit data
plate.
Warning! Please pay attention to sections of the manual
displaying this symbol.
Warning! Do not attempt to use a hose or water jet to clean this unit. For
cleaning instructions, refer to section 6.
Warning! Depending on your unit model, this unit’s system may be
charged with a flammable refrigerant (R290).
The appliance must only be used for the purpose it was designed for and may become
unsafe if used for any other purpose. Operators should be trained. The room where these
units are used must be dry, clean with temperatures between 3°C and 26°C and with
a maximum relative humidity of 60%. These units are for indoor use only and have an
IPX4 rating.
Warning! Drop-in units are not designed to be fitted directly into the
top of a hot cupboard.
When hot cupboards are required, a void section must be created in the
counter, The void section must be designed to support the drop-in unit
and allow a Moat “Roll Under” hot cupboard to be sited in the space
underneath.
The Ambient temperature around the bottom of the
Drop - units must not exceed 55°c
(where the electrics are located)
This appliance must be earthed and damaged cables must be
replaced by a suitably qualified person!
1: Electrical Specification
Live (L1)
L2
L3
Neutral
Earth
1 Phase Cable
Brown
X
X
Blue
Yellow & Green (Striped)
A mains cable, type H07RN-F, conforming to code
designation 60245 IEC 57, is supplied.
3 Phase Cable
Brown
Black
Grey
Blue
Yellow & Green (Striped)
4
Page 5
2: General Installation
2: General Installation
Before installation please read the following points:
• When designing the counter body ensure there is adequate access.
• The counter top must be perfectly level before the drop-in units are installed.
• It is advisable to protect the counter top surface with thick card, hardboard, thin plywood sheet or
similar, to avoid accidental damage during positioning.
• Each drop-in is secured to the counter top with a continuous
bead of silicon sealant between the unit & work surface.
• An adequate amount of personnel (or lifting gear if available)
should be used, to avoid any risk of injury or damage to equipment.
• Before installing, it is recommended that the work top is protected & all loose items are removed
from unit to aid handling i.e. Glass screens, canopies, etc.
This equipment is designed to be operated by suitably qualified
persons. It is the responsibility of the Supervisor or equivalent to
instruct users, provide suitable P.P.E., show the mains isolating switch
location, and inform users that parts may become hot, causing injury if
touched.
1. Remove all packaging & plastic coatings
from the appliance. Check for any damage.
2. Assemble all parts, including shelves, food containers etc.
3. Bain-marie Dry Well: Ensure that the heater
is located correctly and plugged in.
4. Heated units: Fit the supplied halogen bulbs to the holders under the gantry.
5. Ensure all switches and thermostat controls are in the OFF position.
6. Connect the mains input plug to the socket outlet.
7. Turn on and check the unit is functioning correctly.
5
Page 6
2: General Installation
2.1: Method
• Drop-In units are designed for installation using the minimum of tools.
• They can be installed into any type of counter body so long as the carcass construction is
strong enough to support their weight.
• Drop-In models require a bed of sealant to fix them in place.
• All models require a cut out in the top of the counter body. Therefore, a void or empty
cupboard directly under the Drop-in should be allowed for.
6
Page 7
Surface Mounted
2: General Installation
Flush with Surface
7
Page 8
2: General Installation
2.2: Cut-out Dimensions
Depending on the type of counter top material. Installers may choose to cut-out the
proposed hole on-site. Use the table below to establish & mark out the correct cut-out
size of your chosen drop-in model. Alternatively, CNC operators can use the table when
preparing materials that can only be machined o site (i.e. Stone, metal, etc.).
Note: When laying out the cut-out position, care should be
taken to make sure the ‘drop-in’ body does not foul the inside
of the unit carcass under.
For a flush fit, the routed out edge provides a 3mm gap to seal with..
Standard Dimensions
8
Page 9
Soup Station
Plate Dispenser
2: General Installation
Universal Crockery Dispenser
9
Page 10
2.3: Air Vent Cut-Out Dimensions
All Size 2 Refrigerated Units
(D2RD Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
10
Page 11
All size 2 units with back to wall
(D2RDFC Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
11
Page 12
All size 3, 4 & 5 refrigerated units
(D3RD Illustrated)
2.3: Air Vent Cut-Out Dimensions
Airflow direction
(D4RW Illustrated)
12
Airflow direction
Page 13
All size 3, 4 & 5 refrigerated units with back to wall
(D3RDFC Illustrated)
2.3: Air Vent Cut-Out Dimensions
(D4RW Illustrated)
13
Page 14
2.4: Refrigerated Units Additional Operation & Installation Conditions
To ensure the satisfactory operation and optimum eciency of this unit, it is
imperative that the ambient room conditions where the units are being used do
not exceed a room temperature of 25°c or exceed a relative room humidity of
60%.
Should conditions exceed the above, the display units may not maintain
food temperatures at the required levels. E&R Moat cannot accept
responsibility for the performance of the units being used in extreme
conditions.
Do not:
• Install units where there is high radiated heat, e.g. direct
sunlight, room heaters, or bright spot lights
2: General Installation
• Install units in draughty conditions where the air movement
is greater than 0.2mtr/sec. (e.g. near doors, windows, air
conditioning units or fans].
When installing these refrigerated units, allowances must be made for air venting. It is
crucial that there is an unrestricted air flow through the under slung compressor and
condensing coil.
Proper venting must be provided ensuring cool air from the room can be pumped in
through the condensing coil and out the other side.
The hot air blown out from the opposite side ‘must not’ be allowed to be sucked back
through the condensing coil [see image on page 15].
Air Flow (see image on page 15) provides a general understanding
of the compressor airflow through our standard refrigerated Dropin compressor housing. Do not let the warm expelled air from the
compressor recycle directly back through the Condensing coil.
14
Page 15
2: General Installation
15
Page 16
Where the drop-in requires boxing in the ‘Plenum Duct’ supplied
should be fitted to fill in the void between the drop-in body & the
shop-fitted counter panels.
Blocked vents will cause reduced eciency and
lead to malfunction:
2: General Installation
Plenum Duct in Si-tu, a ‘plenum duct’ will be required in certain situations
to stop expelled air from the compressor being directly recycled into the
coil vent. This box should be fitted to suit the gap between drop-in and the
counter panel.
16
Page 17
2: General Installation
Vent Grill Installation
Drop-in units are designed to slot into a pre-fabricated
counter that’s open to the rear (Operators Side), to allow a free circulation of
air through the compressor housing. If the design of the counter dictates the
rear to be panelled o, remove the two vent grills that are factory fitted and
relocating them onto the shop-fitted rear panel (By others). The ’plenum duct’
would need to be fitted, to fill in the void behind the panel.
1. Remove the two Vent panels from the compressor housing.
2. Referring to the diagrams on pages 10 & 13, mark and cut out the vent holes.
3. Referring to the dimensions on the diagram below, mark out the centre hole for both vent
brackets make sure there is an even overhang top & bottom of the vent cut-out.
4. Drill a pilot hole & secure brackets using
17
Page 18
1/2” (12mm) x 8 pan head screws or similar.
5. Drill pilot holes for the four remaining top and bottom bracket fixings, & secure.
6. Oer up the Vent Grill on to the brackets
and secure using the machine bolts provided.
2: General Installation
The vent grill can be removed, providing access to clean the compressor coil.
Lifting Unit into Position
Two lifting tubes are supplied with each unit. These tubes should be used when
moving or lifting the unit into position. Lifting eyes are also supplied and are
designed to be temporarily fitted on each corner of the display well to aid
lifting into position and must be removed after installation is complete.
• First remove the perspex screen.
• Fit the lifting plates using the screws located on each corner of the well
• Slide each lifting tube through a set of lifting eyes,one at each end of the unit.
• Lift into position using the lifting tubes supplied.
• Allow an even amount of tube to protrude from each side (800mm Approx.)
• This will provide enough room for two people to get a comfortable grip at each corner. Consult the
unit specifications to decide on the number of people needed to lift the unit, approximately 25Kg
18
per person is
recommended.
• Check your own company’s health and safety policy before attempting to lift. Alternatively, a
small portable lifting hoist can be used to lift the unit. Pass lifting ropes through the lifting eyes
taking care not to cut or damage the ropes.
• When the unit has been lowered into place remove lifting eyes.
• Remove tubes and remove the lifting plates.
• Replace the screws and refit the perspex screen.
Page 19
Lifting Unit into Position
Lifting Plate
Temporarily fit to each corner of the well
2: General Installation
Remote Control Box Cut-out Dimensions (for units with no gantry fitted)
The control box is designed to be fitted on a counter side
panel.
0
.
5
8
• The cut out dimensions for the box are 185mm x
120mm
• Fixing holes are on163mm centres
200.0
5
.
7
6
0
.
5
3
1
5
.
7
6
0
.
5
1
1
163
19
Page 20
3: Hot-Top:
Specifications
Model
D2HTNG
D3HTNG
D4HTNG
D5HTNG
D2HT
D3HT
D4HT
D5HT
D2HTF
D3HTF
D4HTF
D5HTF
D2HTSL
D3HTSL
D4HTSL
D5HTSL
D2HTSLF
D3HTSLF
D4HTSLF
D5HTSLF
D2HTD
D3HTD
D4HTD
D5HTD
D2HTDSL
D3HTDSL
D4HTDSL
D5HTDSL
Weight
(kg)
18
24
31
39
24
31
39
48
36
46
57
68
30
40
51
63
38
48
59
71
34
46
57
68
38
48
59
71
Length
x Depth
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
Height
above
display top
0
0
0
0
408
408
408
408
408
408
408
408
396
396
396
396
396
396
396
396
540
540
540
540
540
540
540
540
No.
of
180w
Neo
Ceram
Hot
Plates
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
No of
220w
lamps
N/A
N/A
N/A
N/A
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Electrical
Supply
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
Hot-Top
Power
Rating
(kw)
0.36
0.54
0.72
0.90
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
0.58
0.98
1.38
1.78
20
Page 21
Operation
Hot-Tops are designed to keep pre-cooked food at serving temperature and are suitable
for the display of most types of hot foods. They are fitted with easy to clean Neo-Ceram
thermo panels Their energy regulated surface temperature is controlled at around 90°.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, and quantity. Flat base
dishes are recommended to allow best heat transfer.
The Hot Top & Gantry are both controlled by a green
neon on/o switch and energy regulating control knob.
Hot-Top
1. Connect plug to 13-Amp socket
and switch on at mains socket.
2. Power on with green illuminated
Switch
3. Turn Control Knob to position 3
[Full Power]
4. Leave for 15mins to reach serving
temperature
5. Set the temperature of the
Hotplate to the desired position
(Control range between 1-3 with 3
being full power).
6. Dishes with ‘precooked’ food can
now be loaded.
7. When serving is complete all
switches should be turned o.
8. To maintain the life clean regularly
with a damp cloth.
21
Page 22
4: Bainmarie Dry Heat:
Specifications
Height
Model
D2BMNG
D3BMNG
D4BMNG
D5BMNG
D2BM
D3BM
D4BM
D5BM
D2BMF
D3BMF
D4BMF
D5BMF
D2BMSL
D3BMSL
D4BMSL
D5BMSL
D2BMSLF
D3BMSLF
D4BMSLF
D5BMSLF
D2BMD
D3BMD
D4BMD
D5BMD
D2BMDSL
D3BMDSL
D4BMDSL
D5BMDSL
Weight
(kg)
23
29
36
44
30
38
47
57
38
47
57
68
36
47
59
71
44
55
67
79
40
52
65
76
44
54
67
79
Length
x Depth
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
above
display top
13
13
13
13
408
408
408
408
408
408
408
408
396
396
396
396
396
396
396
396
540
540
540
540
540
540
540
540
GN 1/1
Capacity
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
No of
220w
lamps
N/A
N/A
N/A
N/A
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Bainmarie Dry Heat
Electrical
Supply
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
Power
Rating
(kw)
0.9
1.5
1.5
1.9
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
1.12
1.94
2.16
2.78
22
Page 23
Bainmarie Dry Heat
4: Bainmarie Dry Heat:
Operation
Bain-marie units are designed to keep pre-cooked food at serving temperature and
are suitable for the display of most types of hot foods, complete with an inset well
designed to accommodate various combinations of interchangeable Gastronome
type pans up to 150 mm deep. Each opening can also be fitted with an optional
spiked carvery pad or Neo-Ceram Hot Top adaptor.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, amount of food in
container, etc. Fit empty pans and lids into their openings before switching the unit on.
After the 30mins has elapsed load food and replace lids. Do not remove lids until service is
due to commence.
The Bain-marie & Gantry are both controlled by a green
neon on/o switch and a digital temperature control.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch
3. Digital illuminates and controls the Bain-marie well temperature
4. Leave for 30mins to reach serving temperature
5. Set the temperature of the Bain-marie to the desired position (Factory set at
95° adjustable between 80° and 100°].
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
To maintain the life clean regularly with a damp cloth.
23
Page 24
How to Change the Temperature Setting
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature set-point
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm,
or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change
will be cancelled.
the action
24
Page 25
The Dry heat Bain-marie well incorporates an innovative
fan assisted heating unit. This compact heating unit is
removable for easy cleaning and maintenance.
There are two hot air distribution channels - one on either side
of the fan. Note: The smaller Size 2 units have the Fan only.
A
Hot Air Distribution channels (Take hold of channel and lift upwards)
B
Sahara Fan (Take hold of casing and lift
upwards) Replacing both items is a reversal:
Bainmarie Dry Heat
These units will remain hot for a long period of time after use.
Air flow vents must not be blocked.
• The 4 clear arrows represent air entering the Sahara fan ‘B’
• The Black arrows show the regenerated hot air being evenly distributed
25
Page 26
5: Bainmarie Wet Heat:
Specifications
Height
Model
D2BMWNG
D3BMWNG
D4BMWNG
D5BMWNG
D2BMW
D3BMW
D4BMW
D5BMW
D2BMWF
D3BMWF
D4BMWF
D5BMWF
D2BMWSL
D3BMWSL
D4BMWSL
D5BMWSL
D2BMWSLF
D3BMWSLF
D4BMWSLF
D5BMWSLF
D2BMWD
D3BMWD
D4BMWD
D5BMWD
D2BMWDSL
D3BMWDSL
D4BMWDSL
D5BMWDSL
Weight
(kg)
27
35
44
54
34
44
55
67
44
53
65
78
40
53
67
81
48
61
75
89
44
58
76
86
48
60
75
89
Length
x Depth
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
above
display top
408
408
408
408
408
408
408
408
396
396
396
396
396
396
396
396
540
540
540
540
540
540
540
540
13
13
13
13
GN 1/1
Capacity
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
No of
220w
lamps
N/A
N/A
N/A
N/A
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Bainmarie Wet Heat
Electrical
Supply
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
13amp
16amp
32amp
32amp
Power
Rating
(kw)
2.0
3.0
4.0
5.0
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
2.22
3.44
4.66
5.88
26
Page 27
Bainmarie Wet Heat
Operation
Bain-marie units are designed to keep pre-cooked food at serving temperature and
are suitable for the display of most types of hot foods, complete with an inset well
designed to accommodate various combinations of interchangeable Gastronome
type pans up to 150 mm deep. Each opening can also be fitted with an optional
spiked carvery pad or Neo-Ceram Hot Top adaptor.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, amount of food in
container, etc. Fit empty pans and lids into their openings before switching the unit on.
After the 45mins has elapsed load food and replace lids. Do not remove lids until service is
due to commence.
This a wet heat only unit. The heating elements must always be
fully immersed in water. Before switching on fill with water up
to the level mark and make sure the drain valve is in the closed
position.
Filling and maintaining the water level refer to page 29.
The Bain-marie & Gantry are both controlled by a green neon on/o
switch and a digital temperature control.
1. Connect plug and switch on at mains outlet
2. Power on with green illuminated Switch
3. Digital illuminates and controls the Bain-marie well temperature
4. Leave for 45mins to reach serving temperature
5. Set the temperature of the Bain-marie to the desired position (Factory set at
95° adjustable between 80° and 100°]
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
27
Page 28
How to Change the Temperature Setting
Bainmarie Wet Heat
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature set-point
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm,
or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change
will be cancelled.
the action
28
Page 29
Filling the Well
1. First check the drain valve is fitted correctly and in the closed position.
2. Carefully fill well with warm water (if available) up to the water level mark.
3. Fit empty pans and lids into their openings before switching the unit on.
4. Leave for 45mins to reach serving temperature
Low Water Level Sensor
This Wet Well Bain-marie is fitted with a low water sensor, which sends a
flashing ‘Al’ message to the display on the digital controller when the water level
falls below an acceptable level.
If this message appears, [ “flashing” AI ]:
Bainmarie Wet Heat
1. Switch o the green mains switch.
2. Immediately refill with water up to the water level mark.
3. Switch power back on using the green mains switch.
4. The digital control will reset and continue to control the temperature.
If the water level is left to fall below the heating element, premature
failure of the heating element may result.
29
Page 30
Draining the Well
1. Switch o & disconnect unit from mains power.
2. Wait until water cools down to room temperature.
3. Open drain valve & fill container.
4. Switch o valve & empty container when full in a suitable place.
5. Repeat until well is empty.
6. Close drain valve.
Bainmarie Wet Heat
30
These units will remain hot for a long period of time after use.
If required to top up the water level in mid service,
use suitable heat insulated gloves when removing
the hot Bain Marie containers.
Page 31
6: Heated Display: Specifications
No. of
Display
Shelves
3
3
3
3
3
3
3
3
Model
D2HD
D3HD
D2RDF
D3RDF
D2RDSL
D3RDSL
D2RDSLF
D3RDSLF
Weight
(kg)
66
87
66
87
66
87
66
87
Length
x Width
(mm)
830 x 660
1158 x 660
830 x 660
1158 x 660
830 x 660
1158 x 660
830 x 660
1158 x 660
Height
above
display top
750
750
750
750
750
750
750
750
6: Heated Display: Operation
Electrical
LED Roll
Ilumination
Yes
Yes
Supply
13amp
13amp
Yes
Yes
Yes
Yes
13amp
13amp
13amp
13amp
Yes
Yes
13amp
13amp
Power
Rating
(kw)
1.05
1.50
1.05
1.50
1.05
1.50
1.05
1.50
Designed to keep pre-cooked food at serving temperature and are suitable for the display of most types
of hot foods. Heated shelves have a removable perforated adaptor for use when less direct heat form the
shelves is requiered such as bread products rolls and sandwiches.
These units are not designed to heat up cold food.
The correct serving temperature is dependent on the food type, quantity and packaging, etc.
The Display unit is controlled by a green neon on/o switch and a digital temperature control.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch.
3. Digital illuminates and controls the display temperature.
4. Leave for 30mins to reach serving temperature.
5. Set the temperature of the display to the desired position (Factory set at 80°
adjustable between 60° and 95°]
6. Precooked food can now be loaded.
7. When serving is complete all switches should be turned o.
To maintain the life clean regularly with a damp cloth.
31
Page 32
6: Heated Display: Operation
How to Change the Temperature Setting
Unlocking the keypad
• Press any button (SET, ON/STAND-BY, DOWN or UP) the display shows LoC
• Press and hold the SET, keypad lock button for 1 second and the display will show UnL.
Setting the temperature setpoint
• Touch the SET button and use either the DOWN or UP buttons to change the set point.
• Once the set point has been chosen, press the SET button to confirm,
or press the ON / STAND-BY, escape button to cancel.
Note
If the SET or ON / STAND-BY, escape buttons are not pressed within 15 seconds of making a change
will be cancelled.
• Hot display units, bain-maries, and hot tops, are designed to hold pre-heated
food products at regulated temperatures in an ambient room temperature above
16°C.
• Consideration should be made when sighting to avoid positioning
close to air conditioning vents, windows and doors where cold
draughts may be present.
(Food temperature and quality may be aected).
the action
32
• Do not install units in draughty conditions where the air movement is greater
than 0.2mtr/sec
Page 33
7: Refrigerated Well:
Specifications
NOTE: Island models with double sided curved glass screens have an “ I “ added to the code.
Length
Model
D2RWNG
D3RWNG
D4RWNG
D5RWNG
D2RW
D3RW
D4RW
D5RW
D2RWF
D3RWF
D4RWF
D5RWF
D2RWSL
D3RWSL
D4RWSL
D5RWSL
D2RWSLF
D3RWSLF
D4RWSLF
D5RWSLF
D2RWD
D3RWD
D4RWD
D5RWD
D2RWDSL
D3RWDSL
D4RWDSL
D5RWDSL
Weight
(kg)
67
76
85
93
74
85
95
105
82
94
105
116
74
85
95
105
82
94
105
116
78
91
102
115
82
94
105
117
x Depth
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
display top
Height
above
25
25
25
25
408
408
408
408
408
408
408
408
396
396
396
396
396
396
396
396
540
540
540
540
540
540
540
540
GN 1/1
Capacity
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
LED Roll
Illumination
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Refrigerated Units
Electrical
Supply
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
Power
Rating
(kw)
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
1.0
1.5
1.5
2.0
33
Page 34
Refrigerated Units
7: Refrigerated Display [2 Shelf]: Specifications
Model
D2RDL
D3RDL
D4RDL
D5RDL
D2RDLF
D3RDLF
D4RDLF
D5RDLF
D2RDLFC
D3RDLFC
D4RDLFC
D5RDLFC
D2RDLSA
D3RDLSA
D4RDLSA
D5RDLSA
D2RDLSL
D3RDLSL
D4RDLSL
D5RDLSL
D2RDLSLF
D3RDLSLF
D4RDLSLF
D5RDLSLF
D2RDLSLFC
D3RDLSLFC
D4RDLSLFC
D5RDLSLFC
Weight
(kg)
114
134
151
171
122
143
161
182
104
119
131
157
119
140
158
179
116
137
155
176
124
146
165
187
114
131
145
162
Length
x Depth
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
Height
above
display top
540
540
540
540
540
540
540
540
540
540
540
540
645
645
645
645
645
645
645
645
645
645
645
645
645
645
645
645
No. of
Display
Shelves
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
LED Roll
Ilumination
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Electrical
Supply
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
Power
Rating
(kw)
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
34
Page 35
Refrigerated Units
7: Refrigerated Display [3 Shelf]: Specifications
Model
D2RD
D3RD
D4RD
D5RD
D2RDF
D3RDF
D4RDF
D5RDF
D2RDFC
D3RDFC
D4RDFC
D5RDFC
D2RDSA
D3RDSA
D4RDSA
D5RDSA
D2RDSL
D3RDSL
D4RDSL
D5RDSL
D2RDSLF
D3RDSLF
D4RDSLF
D5RDSLF
D2RDSLFC
D3RDSLFC
D4RDSLFC
D5RDSLFC
Weight
(kg)
124
149
171
196
132
158
181
207
114
134
151
182
129
155
178
204
126
152
175
201
134
161
185
212
124
146
165
187
Length
x Width
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
Height
above
display top
750
750
750
750
750
750
750
750
750
750
750
750
855
855
855
855
756
756
756
756
756
756
756
756
756
756
756
756
No. of
Display
Shelves
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
LED Roll
Ilumination
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Electrical
Supply
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
Power
Rating
(kw)
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
1.5
1.7
1.7
1.7
35
Page 36
7: Refrigerated Frost Top:
Specifications
NOTE: Island models with double sided curved glass screens have an “ I “ added to the code.
Height
Model
D2FTNG
D3FTNG
D4FTNG
D5FTNG
D2FT
D3FT
D4FT
D5FT
D2FTF
D3FTF
D4FTF
D5FTF
D2FTSL
D3FTSL
D4FTSL
D5FTSL
D2FTSLF
D3FTSLF
D4FTSLF
D5FTSLF
D2FTD
D3FTD
D4FTD
D5FTD
D2FTDSL
D3FTDSL
D4FTDSL
D5FTDSL
Weight
(kg)
50
60
70
80
60
70
85
90
70
80
95
105
60
70
85
95
70
85
95
105
70
75
85
95
70
80
90
105
Length
x Width
(mm)
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
830 x 660
1158 x 660
1486 x 660
1814 x 660
above
display top
25
25
25
25
408
408
408
408
408
408
408
408
396
396
396
396
396
396
396
396
540
540
540
540
540
540
540
540
GN 1/1
Capacity
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
LED Roll
Illumination
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Refrigerated Units
Electrical
Supply
Power
Rating
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
13amp
(kw)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
36
Page 37
Refrigerated Units
Operation
Warning! This unit’s system is charged with a
flammable refrigerant (R290).
Before commencing there are certain environmental parameters
that must be followed please read the additional installation
conditions on page 14.
Refrigerated display units are designed to keep pre-chilled food at a regulated serving
temperature and are suitable for the display of most types of cold food. Designed to provide a
gentle flow of cold air maintaining a safe and compliant temperature within. The Chilled display
has an automatic defrost, and automatic condensate water evaporation system, eliminating the
need to manually empty drip trays or install on-site drainage.
The controlled air temperature is factory set to
operate between 2° and 5°.
To enable automatic condensate evaporation, the 13A plug
must be constantly switched on.
The green switch can be switched o when the cooling is no longer required, however, do not
unplug the unit from the mains power. The Display unit is controlled by a green neon on/o
switch and a digital temperature control.
37
Page 38
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Power on with green illuminated Switch.
3. Digital illuminates and controls the display temperature.
4. Allow 30mins for the display too cool down before loading product.
5. The controlled air temperature is factory set to operate between 2° and 5°.
6. Defrost is factory set
7. When serving is complete all switches should be turned o.
These units require good airflow inside and outside.
It is essential the vents in the external panels do not become blocked as this
can cause the unit to fail, due to overheating. Internally good air flow must
also be maintained, a small space should be left between all products.
38
Page 39
8: Plate Dispenser:
Specifications
Length
Model
DUP1
DUP2
DHP1
DHP2
Weight
(kg)
15
27
16
28
x Depth
(mm)
400 x400
400 x 740
400 x400
400 x 740
Height
above
display top
150
150
150
150
Capacity
65
2 x 65
65
2 x 65
No of
220w
lamps
N/A
N/A
N/A
N/A
Electrical
Supply
N/A
N/A
13amp
13amp
Plate Dispenser
Power
Rating
(kw)
N/A
N/A
0.6
1.2
8: Plate Dispenser:
Operation
In-counter spring-loaded pop-up plate dispensers Single or twin plate
dispensers, in both ambient & heated formats.
• Variable spring system to accommodate dierent plate weights.
• Each tube can take a maximum of 65 plates
(Depending on type of plate used).
Heated Models:
• Thermostat controlled internal air temperature approximately 60°.
• Complete with ergonomic black ABS plate cover.
• Supplied with a 2-meter cable fitted with a
13-amp moulded plug for easy installation.
39
Page 40
Operation:
• Load the Tube & cover plates with
the supplied black ABS plate cover.
• Switch on the unit using the green switch.
• Allow approximately 60min to warm the plates before serving.
• When serving; remove the top plate & the
plate below will automatically pop up
• Keep lid in place whenever possible during service
Never discard the lid. The lid holds the heat inside maintaining an even
temperature. if the lid is left o for extended periods the heating will not
control the temperature properly and the bottom plates could become too
hot and damage to the elements may occur.
Plate Dispenser
• Allow all heated units to cool after service before cleaning.
(Cleaning instructions are given on page 52).
40
Page 41
Plate Dispensers Additional Setting Up And Commissioning
The element on the heated units will remain hot for a period after use. Care
should be taken to avoid injury.
Setting the Plate Diameter
Using one plate only set the guides to their correct
positions for the size of plate.
All 4 guides must be set to the same position/number
Plate Dispenser
Plate Diameter
8” (203mm)
9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Plate Guide Position
8
9
10
11
12
41
Page 42
Setting the Spring Tension
Plates sits on a removable Plate Base Support which in turn rests on a
floating platform. This ‘Floating Platform’ in turn, is supported by several
tension springs.
The tension springs are fastened symmetrically on two sides.
In order to access the tension springs the Plate Base Support needs to be
removed.
1. Pull up the spring loaded ‘Plate Guides and swivel anticlockwise to
their extreme outer positions & lower down again for them to lock into
their ‘service’ positions.
Plate Dispenser
42
Page 43
2. Lift ‘Plate Base’ straight upwards until the location tabs on the underside are
fully removed from the ‘Floating Platform’ slots.
Plate Dispenser
3. The ‘Floating Platform’ is supported by an equal amount of tension springs on each corner. The
number of springs equates to the size of plate being used.
Use the chart below as a starting point; add or remove
springs accordingly (in groups of four, one each corner),
until the top plate is at the required serving level)
The Springs are held in place using a hook & eye arrangement top & bottom. They can be easily
attached or detached by just hooking or unhooking the end in to or out of the corresponding
hole on the Floating support Arm.
There must be an equal amount of springs on all four corners. The four
corner springs should not be removed. When removing springs, start
from the centre outwards. When adding springs work from the corners
inwards. Keep the spring numbers symmetrical whenever possible.
43
Page 44
Plate Dispenser
Plate Diameter
8” (203mm)
9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Below shows the Plate lift set up for the weight of 9” Plates. Only the 3 outer springs are
attached to each corner of the Floating Platform. The 3 inner springs on the left, are shown
in their storage position. [hook on top only]
Number of Springs on
Each Corner
2
3
4
5
6
Total Number of Springs
8
12
16
20
24
44
Page 45
9: Universal Crockery Dispenser
Specifications
Height
Model
DHD1
DAD1
Weight
(kg)
13
11
Length
x Depth
(mm)
420 x 345
420 x 345
above
display top
30
30
Capacity
65
65
No of
220w
lamps
N/A
N/A
Universal Crockery Dispenser
Electrical
Supply
13amp
N/A
Power
Rating
(kw)
0.6
N/A
Universal Crockery Dispenser:
Operation
In-counter spring-loaded pop-up plate dispensers. Single tube in both ambient & heated formats.
Ideal for oval, round & square crockery including bowls up to 305mm (12”). bowl capacity may
be less depending on the type.
• Variable spring system to accommodate dierent plate weights.
• Each tube can take a maximum of 65 plates
(Depending on type of plate used).
Heated Models:
• Thermostat controlled internal air temperature approximately 60°.
• Complete with ergonomic Stainless-Steel lid.
• Supplied with a 2-meter cable fitted with a
13-amp moulded plug for easy installation.
45
Page 46
Operation:
• Load the Tube & cover plates with the supplied Stainless-Steel lid.
• Switch on the unit using the green switch.
• Allow approximately 60min to warm the plates before serving.
• When serving; remove the top plate & the
plate below will automatically pop up.
• Allow all heated units to cool after service before cleaning.
Universal Crockery Dispenser
46
The element on the heated units will remain hot for a period after
use. Care should be taken to avoid injury.
Page 47
Universal Crockery Dispenser
Setting the Spring Tension
Plates sits on a removable Plate Base Support which in turn rests on a floating platform. This
‘Floating Platform’ in turn, is supported by several tension springs. The tension springs are
fastened symmetrically on two sides.
In order to access the tension springs the
Plate Base Support needs to be removed.
1. Remove lid & store in safe place.
2. Lift out plate/bowl carriage & store in safe place.
3. Unscrew the 4 bolts which secure the two inner panels and remove.
4. Adjust the springs (refer to page 49).
5. Relocate the inner panels. 2 Tabs on the bottom 2 screws on the top of each.
47
Page 48
Universal Crockery Dispenser
6. The ‘Floating Platform’ is supported by an equal amount of tension
springs on each corner. The number of springs equates to the size of
plate being used. Use the chart below as a starting point; add or
remove springs accordingly (in groups of four, one each corner),
until the top plate is at the required serving level).
The Springs are held in place using a hook & eye arrangement top & bottom. They can be easily
attached or detached by just hooking or unhooking the end in to or out of the corresponding
hole on the Floating support Arm.
The element on the heated units will remain hot for a period after
use. Care should be taken to avoid injury.
Plate Diameter
8” (203mm)
9” (229mm)
10” (254mm)
11” (279mm)
12” (305mm)
Number of Springs on
Each Corner
2
3
4
5
6
Total Number of Springs
8
12
16
20
24
48
Page 49
10: Soup Station
Soup Station
Specifications
Height
Model
D1SDT
D2SDT
Weight
(kg)
5
8
Length
x Depth
(mm)
300 x 455
550 x 455
above
display top
70
70
Capacity
1x 4lt
1x 4lt
No of
220w
lamps
N/A
N/A
Electrical
Supply
13amp
13amp
Power
Rating
(kw)
0.35
0.70
Soup Station:
Operation
Along with a removable drip tray which aids cleaning, they also come supplied with the appropriate
amount of 4,5litre stainless steel pots, complete with stainless steel lids. Controls are surface
mounted for convenience, and consist of an neon power indicator and an energy regulator dial.
The correct serving temperature is dependent on the food type / amount etc.
1. Connect plug to 13-Amp socket and switch on at mains socket.
2. Fit empty pans and lids into their openings
3. Power on with green illuminated Switch
4. Turn control Knob to position No 110.
5. Leave for 30mins to reach serving temperature.
6. Set the Knob to the desired position.
(around 90 will keep soup warm].
7. Precooked Soup can now be loaded.
8. Do not remove lids until service is due to commence.
9. When serving is complete all switches should be turned o.
10. To maintain the life clean regularly with a damp cloth.
These units are not designed to heat up cold food.
1. Precooked Soup can now be loaded.
2. Do not remove lids until service is due to commence.
3. When serving is complete all switches should be turned o.
4. To maintain the life clean regularly with a damp cloth.
49
Page 50
11: Cleaning
11: Cleaning
Before attempting to clean the unit, please ensure that the Unit is isolated
from the electric supply and allowed to cool down,
with all food plates and other Dishes removed from the unit.
Do not use a water jet or pressure
spray to clean this appliance.
1. Disconnect trolley from mains and wait until appliance has cooled.
2. Wipe clean using hot, soapy water and soft, non-abrasive cloth. Ensure that the stainless steel is
wiped in straight strokes following the grain of the material.
3. Wipe dry using a clean cloth. Do not use scouring pads or abrasive cleaners of any type. Shelving
and select inner panels can be removed to allow a deeper internal clean. Ensure all panels and
fixings are replaced after cleaning operation.
4. Refrigeration compartment should be washed and then dried with a cloth after each service.
5. The chilled well has removable base sections for easy cleaning and maintenance. They should be
removed periodically and the area beneath wiped clean.
6. The drain hole must also be kept clear from blockage.
7. Wipe down sneeze screen and glass top with a damp, clean cloth.
8. Finish by carefully drying with a soft dry cloth or Kitchen Towels.
Do not use scouring pads or abrasive cleaners of any type.
Do not use Solvents, bleach, Caustic Cleaners
or biological powders on any surface.
50
Special care should be taken around electrical parts,
avoided excessive use of water.
Take special care when cleaning glass
use a soft duster & glass cleaner spray.
Page 51
The condensing coil & vents requires regular cleaning to
maintain the performance of the unit, as air borne particles will
choke the coils fins. They should be cleaned with a soft brush
and vacuum.
11: Cleaning
51
Page 52
12: Quartz Lamp Replacement
Ensure appliance is disconnected from mains before servicing.
Lamps should not be touched with bare hands,
as this may cause premature failure. If lamp is touched,
wipe clean with a cloth and alcohol prior to use.
Replacement quartz lamps must
never exceed the loading specified.
Wear safety glasses.
Don’t touch hot halogen bulbs.
Only use replacement bulbs that match
the wattage and design of the fixture.
12: Quartz Lamp Replacement
1. Isolate appliance from power supply and allow cooling
down before commencing lamp replacement.
2. Carefully slide mesh guard to one side until it clears the bulb area.
52
Page 53
3. Remove faulty lamp by pushing to one side then pull down.
Hold the insulated end of the new lamp (Any end).
4. At a slight angle, slot the end of the new lamp into one of the Housing
5. Push against the sprung contact & hold it there.
6. Raise the opposite end of the lamp into the other end of the Lamp.
12: Quartz Lamp Replacement
Each replacement Quartz lamp must never exceed 220W.
53
Page 54
Thank you for choosing E&R Moat!
Scan the QR code below to visit the
E&R Moat website for further information:
E&R Moat Ltd.
Bonnybridge
FK4 2BS
Scotland
www.ermoat.co.uk
+44 (0) 1324 812272
sales@ermoat.co.uk
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.