Moffat Blue Seal AC User Manual

4517 BS ACSeries specs V3 24/6/05 10:52 AM Page 19
TECHNICAL SPECIFICATION SHEET FOR
BLUE SEAL GAS COMBI STEAMER
AC SERIES G40AC DD 40 x 1/1GN or 20 x 2/1
General features:
- Direct steam injection system
- High efficiency heat exchanger and gas burner system
- Stainless steel construction
- Hygienic rounded corners in oven cavity
- Pivoting fan suction panel
- Front removable control panel for easy servicing
- Hygienic plug-in door seal for easy to remove day-to-day cleaning
- Adjustable door hinges
- Self draining door condensate drip tray
- Hand shower
- Oven lights
- Oven door handle with progressive brake mechanism
- Cool to touch double glazed door
- Hinged inner glass for easy cleaning
- Constant self-diagnosis for error recognition
Standard features:
- Electronic manual control panel with cooking modes
- Electronic thermostat 30°C - 300°C
- Electronic timer
- Auto-reversing fan rotation
- Cavity fast cool down which automatically stops at 50°C
- Automatic cavity cool down between high temperature cycles and the next cycle featuring a lower temperature
- Manual humidifier or programmable
- Manual vent to evacuate the excess humidity
- Automatic quenching of vapours into the oven drain
- Cavity clean program
- Energy saving device for a reduced energy consumption
Optional features:
- Interchangeable core probes with external socket
- Marine and special voltages
- LPG Version
- Connection for an external printer (type RS232)
- Connection for energy saving system
Cooking programmes:
Steaming 30°C - 130°C
- For steaming, stewing and poaching
Combination 30°C - 300°C
- For roasting and baking
Convection 30°C - 300°C
- For grilling, quick roasting, baking, toasting and gratinating
- Pre-set Programs
R1 for reheating of plated meals
R2 for reheating of gastronorm containers
RP reheating with manual setting of time and temperature
Optional : Core probe 30°C - 130°C
4517 BS ACSeries specs V3 24/6/05 10:52 AM Page 20
TECHNICAL SPECIFICATION SHEET FOR
BLUE SEAL GAS COMBI STEAMER
AC SERIES G40AC DD 40 x 1/1GN or 20 x 2/1
Dimensions
Width 1290mm Depth 895mm Height 1950mm (with flue extension) 2323mm Weight 450kg
Packed Dimensions
Width 1420mm Depth 1220mm Height 2250mm Weight 560kg
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm
*Clearance required on fixed installations for service accessibility.
If heat sources are located near the RH side of the AC combi, ensure that a minimum distance of 400mm is maintained.
Install in accordance with local body regulations only on horizontal surfaces and not against
Shelves
1/1 GN 40 2/1 GN 20 Shelf Spacings 67mm
Installation requirements
(for precise installation instructions, please refer to the unit’s installation manual).
combustible walls.
Water connection requirements
- Cold water
- Flow pressure (2 to 6 bar)
- soft water connection*
- shut-off valve with return flow inhibitor and dirt filter
- water supply R3/4
- R50 waste water connection
Power connection requirements
Multi pole circuit breaker and all pole disconnection isolator switch
(*Water softener may be required. Please refer to installation manual for water treatment values.)
installed near the appliance.
Supply line voltage; 230-240V ~ 50Hz, 1P+N+E
Gas connection for Natural or LPG R3/4.
Gas Connection
Nominal Gas Consumption (kW) 54
(MJ/hr) 194 Electrical Connection (kW) 1.8 Rated Current (A) (230V) 7.8
Exhaust connection to ventilation system with safety switch.
Observe regulations for gas suppliers.
IPX5 spray-proof and hose proof.
Optional Extras
SC Core temperature probe
KST40 Extra roll-in trolley to suit 40AC DD
KPT40 Plate banqueting trolley to suit 40AC DD
CPT40 Thermal cover for plate banqueting system to suit 40AC DD
A = WATER CONNECTION R3/4
(SOFTENED WATER) refer to installation
manual for water treatment values. B = WATER CONNECTION R C = DRAIN CONNECTION Ø50 D = ELECTRICAL CONNECTION ENTRY E = HIGH/LOW PRESSURE RELIEF VENT F = OVEN VENT Ø80 G = GAS SUPPLY ENTRY R H = GAS FLUE OUTLET Ø80
3
/4
3
/4
Australia
www.moffat.com.au
New Zealand
www.moffat.co.nz
Australia Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road Mulgrave, Victoria 3170 Telephone 03-9518 3888 Facsimile 03-9518 3833 vsales@moffat.com.au
New South Wales
Telephone 02-8833 4111 nswsales@moffat.com.au
South Australia
Telephone 03-9518 3888 vsales@moffat.com.au
Queensland
Telephone 07-3630 8600 qldsales@moffat.com.au
Western Australia
Telephone 08-9562 0263 jberent@moffat.com.au
New Zealand Moffat Limited
Christchurch
Telephone 03-389 1007 sales@moffat.co.nz
Auckland
Telephone 09-574 3150 sales@moffat.co.nz
In line with policy to continually develop and improve its products, Moffat Limited reserves the right to change specifications and design without notice.
Printed in China © Copyright Moffat Ltd Moffat/4517-G40/BH/3.5M/6.05