Technical Data Supply ESR4-NO-21 ESR4-NM-21
Rated voltageU Rated powerDC 2.0 W 2.1 W Rated powerAC 2.4 W/4.4VA 2.5 /4.6VA Residualripple 2.4 V Rated frequency 50 ... 60 Hz Operating voltagerange 0.85 ... 1.1 xU Protection forcontrolcircuitsupply Short-circuit-proof (PTCthermistor) Short-circuit-proof (electronic fuse)
Control circuit
Rated outputvoltageS11,S33to S21 DC 22 V Output current/ peak current 100 mA/ 2000 mA 100 mA / 200 mA Input voltage range
High DC 17.4V to DC 26.4 V
Low DC -3.0 V to DC +5.0 V Rated current/ peak current S12, S31/S22 40 mA/ 100 mA Rated current/ peak current S34, S35 5 mA/ 50 mA Permissible test pulse time tTP/ test frequency ≤ 1000µs / ≤ 10 s Operate timetA1S34 20 ms to 40 ms Operate timetA2S35 200ms to 500 ms 20 ms to 80 ms Min. ONtime tMS34, S35 > 50 ms Lock timet Operate timeof lock t Recovery time t Release time tRK1, K2 < 25 ms Synchronous monitoring time t
Output circuit Enabling paths
Contact equipment 2 NO contacts, positively driven Rated switching voltage U Max. continuouscurrent Inper current path 6 A Max. totalcurrent for all current paths 12 A
Mechanical service life 10 x106switchingoperations
Signalling paths
Contact equipment 1 NC,parallel, positively driven Rated switching voltage U Max. continuouscurrent Inper current path 6 A
Mechanical service life 10 x106switchingoperations
General data
Clearance/creepage distance between circuits to DIN VDE 0110 Part -1: 04.97 Rated impulse withstand level 4 kV Contamination level of device: inside / outside 2 / 3 Rated voltage AC 300 V Protection class to DIN VDE 0470 Part 1: housing / terminals IP 40 / IP 20 Ambient / storage temperature -25 ... +55 / -25 ... +75 ² C Weight 0.21 kg
Terminals and connection
Single-core or finely stranded 1 x 0.14 mmè to 2.5 mmè 2 x 0.14 mmè to 0.75 mmè Stripping length max. 8 mm Finely-stranded with wire-end ferrule to DIN 46228 1 x 0.25 mmè to 2.5 mmè 2 x 0.25 mmè to 0.5 mmè Max. tighteningtorque 0.5 to0.6 Nm
N
SP
ASP
W
S
n
n
--- 70 ms to 130 ms
--- > 7 ms
≥ 40ms ≥ 150 ms
appr. 200 ms --
AC-15: Ue230 V, Ie 4 A (360 h-1) DC-13: Ue 24 V, Ie 4 A (360 h-1)Utilizationcategory according to IEC 947-5-1
AC-15: Ue 230 V, Ie3 A (3600 h-1) DC-13: Ue 24 V, Ie 2.5 A (3600 h-1)
AC-15: Ue230 V, Ie 4 A (360 h-1) DC-13: Ue 24 V, Ie 4 A (360 h-1)Utilizationcategory according to IEC 947-5-1
AC-15: Ue 230 V, Ie3 A (3600 h-1) DC-13: Ue 24 V, Ie 2.5 A (3600 h-1)
AC/DC 24V
SS
N
-1
AC 240 V / DC 300 V
AC 240 V / DC 300 V
Mode dèemploi ESR4-NO-21, ESR4-NM-21
Avis de s´curit´
Le montage,la mise en service, les modifications et le r´´quipement ne doivent ‘ tre effectu´s que par un ´lectrotechnicien ! D´branchez lêappareil / le syste me avant de commencer les travaux ! Dans lecas dêuned´faillance de lêinstallation ou dusyste me, lesappareils du circuit de commande sansisolation ´lectrique peuvent ‘ tre soustension r´seau ! Lors de lêinstallationdes appareils, respectez les r´glementationsde s´curit´pour usage ´lectrique et de la caisse de pr´voyance contre les accidents. Lêouverturedu boıtier ou toute autre manipulation entraıne lêexpiration de la garantie.
Attention !
Respectez le mesures de s´curit´suivantes avant lêinstallation / le montage ou le d´montage :
1. D´branchez lêappareil/ le syste meavant de commencerles travaux !
2. Prot´gez la machine / le syste me contre les red´marragesintempestifs !
3. Assurez-vous que la machine est hors tension !
4. Reliez les phasesa la terreet court­circuitez-les !
5. Couvrez et isolez les pie ces voisines sous tension!
6. Le montage des appareils doit ‘ tre effectu´dansune armoire ´lectrique avec uneclasse de protection min. IP 54.
Attention !
Protection partiellecontre les contacts accidentels ! Classe de protection selon DIN EN 60529. Boıtier / bornes : IP 40/ IP 20. Protection des doigts selon DIN VDE 0106 partie 1.
Mode le de base pour applications Arrˆt dèurgence et porte de protection
• Mode lede base conform´ment a IEC 60204ô 1 et EN 954-1 pour le contro lemonocanal ou a deux canaux de lêarr‘ tdêurgence.
• EN954 cat´gorie 4
• Cat´gorie dêarr‘ t 0 selon EN 60204-1
• D´marrage manuelou automatique
• Avec / sans d´tection de courts-circuits
• Bouclede retour pour le contro lede contacteurs-disjoncteurs externes
• 2 contacts de sortie, 1 contact de signalisation
• Pour lê´laboration designaux provenant des ´l´ments logiques de sortie(OSSD) dêune
barrie rephoto´lectrique selon DIN EN 61496-1
• Pour lêintercalage en arrie re dêun tapis sensibleselon DIN EN 1760-1 (ESR4-NM-21)
• Dispositifantibattement a lîentr´e(ESR4-NM-21)
Vue de face
SUPPLY DEL verte K1 DEL verte K2 DEL verte
Description de lèappareil et du fonctionnement
ESR4-NO-21 Lêappareilest un relaisde s´curit´a deux canaux pour dispositifs dêarr‘ tdêurgence a auto-contro le a chaque cycle ARRETDêURGENCEselon EN 60204-1, dot´derelais a guidage forc´.
Fonctionnement de base: Apre s ´tablissementde la tension d'alimentationsur les bornes A1/A2 et avec les entr´es de s´curit´ferm´es, lêactivation du bouton-poussoir Reset (d´marrage manuel) ferme les contacts de sortie. Les contactsde sortie sêouvrenta lêouverture/la d´sexcitation des entr´esde s´curit´.
Modes de fonctionnement/ Fonctions du syste me
• Commande a un ou a deux canaux Dans lecas de la commande a un canal, les deux canaux de s´curit´CH1 et CH2 sontcommut´s en paralle le,et s´par´ment dans le cas de la commandea deux canaux.
• Sans d´tectionde courts-circuits Les deux canaux de s´curit´sont commut´s sur le potentiel positif(S12 et S31 sur S11).
• Avec d´tectionde courts-circuits Le canal de s´curit´CH1 est commut´surle potentiel positif (S11sur S12) et le canalde s´curit´CH2 sur le potentiel n´gatif (S21 sur S22).
• D´marrage manuel A lêaidedêun bouton-poussoir,les entr´es de s´curit´´tantferm´es, lêentr´ede reset S34 est ouverte (d´clenchement avec le front descendant)ou lêentr´ede reset S35 est ferm´e (d´clenchement avec le front montant).
• D´marrage automatique Lêentr´e de reset S35 est connect´e a S33.Lêappareild´marre avec lefront montant du signal a lêentr´ede s´curit´S12.
• Blocage de d´marrageLors de lê´tablissementde la tension dêalimentation et avec les entr´es de s´curit´ferm´es,les contacts de sortiene sont pas ferm´s. Le d´marrage peut ‘ tre uniquement obtenu apre s lêactionnement dubouton-poussoir Reset. Pour le blocagede d´marrage, les entr´es de reset doivent ‘ tre command´es par bouton-poussoir comme pour le modede fonctionnement D´marrage manuel.
• Blocage de red´marrage Apre s lêouverture et la fermeture des entr´es de s´curit´, aucun nouveau d´marrage nêa lieu. Le red´marrage peut ‘ tre uniquement obtenu apre s lêactionnementdu bouton-poussoir Reset. Pour le blocage de red´marrage,les entr´es de reset doivent‘ tre command´es par bouton-poussoir comme pour le mode de fonctionnement D´marragemanuel.
• Compatible OSSD Les ´l´ments logiques de sortie (OSSD) dêune barrie rephoto´lectrique ou dêautres d´tecteurs de s´curit´avecsorties semiconducteur peuvent ‘ tre ´labor´s. Les impulsions de test de valeur < tTPnêinfluencent pas les fonctions de lêappareil.Les impulsions de testde valeur > tTPpeuvent verrouillerlêappareil.
• Contro le du d´synchronisme Dans le casde commande a deux canaux, les deux canaux de s´curit´sontcontro l´slêuncontre lêautreavec le temps de synchronisationtS.Le canalde s´curit´CH1doit se fermer avant CH2,et le pont S33/S35 doit ‘ tre reli´. Si CH2 se ferme avant CH1, le temps de synchronisation prend lavaleur t
ESR4-NM-21 Lefonctionnement correspond a celuidu ESR4-NO-21, sans contro ledu d´synchronisme. Lêappareil peut ‘ tre connect´a la suite a des tapis, barres ou bords sensibles a court-circuit en technique a 4 fils(sans r´sistance de surveillance). Lêappareildoit ‘ tre utilis´a deux canaux,avec d´tection de courts-circuits. Avec uner´sistance< 50 Ω/canal et un court- circuit entreles canaux (S11/S12 et S21/S22),les contacts de sortie sêouvrent,la DELSUPPLY clignote. Undispositif antibattement a lêentr´e emp‘ che lacommutation rapide cons´cutive des sorties dêautorisation, lorsque les entr´es de s´curit´sont ouvertes un temps plus court que t
Des entre es de se curite ouvertes plus longtemps que t sortie apr` s tR.Une nouvelle commutation est bloque e pour la dure e tSP.
Observez ´galementles informations de votre caisse de pr´voyance contre les accidents.
∞.
S =
entraınent lèouverture des contacts de
ASP
ASP.
6
7
Page 2
Usage conforme
Lesappareilssontdes relaisdes´curit´.Ilsdoiventuniquement‘ treutilis´scommecomposantsdedispositifsdeprotectionsur les machines,en vue de prot´gerl'homme,lemat´rieletlamachine
Notes
• La cat´gorie de s´curit´selon EN 954-1 d´penddu circuit ext´rieur, du choixde lê´metteur dêordreset de leur allocationdans la machine.
• En principe, lors de lêutilisationde lêappareil,les temps indiqu´sdoivent ‘ tre respect´s, leur non-respectpouvant mener au verrouillage de
lêappareil.Le verrouillagepeut ‘ tre supprim´par lêouverture correctedes entr´es de s´curit´.
• Pour la duplication des contacts de sortie, il est possible dêutiliserdes blocs dêextension de la s´rie SNE ou des contacteurs-disjoncteurs externes avec des contacts a guidage forc´.
• Lêappareilet lescontacts doivent ‘ tre prot´g´s par des fusiblesde 6 A max. de la classe de service gG.
• Les appareilssont dot´s dêuneprotection contre les surcharges (en cas de court-circuit) Apre slê´limination de la cause dela panne, lêappareil
est denouveau pr‘ t a fonctionnerapre s env.3 secondes.
• La sortiede commande S11 est uniquement destin´e au raccord d'´metteurs d'ordre conform´ment au mode d'emploi, et non au raccord de r´cepteurs externes, comme par exemple des lampes, relais ou des contacteurs-disjoncteurs.
Proper Use
Thedevicesaresafetyswitchingdevices.Theymustonlybeusedascomponentsof safetyequipmentonmachinesintendedto protectpersons,materialand plant.
Notes
• The safetycategory acc. to EN 954-1depends on the external circuitry, the choice of control devices and their location on the machine.
• The indicated times must be observed when the device is operated, otherwise thedevice could lock. Locking canbe cancelled by opening the
safety inputs properly.
• SNEexpansion devices or external contactors withpositively driven contacts can be usedto duplicate the enabling current paths.
• The device and the contacts must beprotected at max. 6 A utilizationcategory gG.
• The devices are equipped with overload protection(for short-circuit). After the malfunction has been dealt with, the deviceis operational again
in approx.3 s.
• Control output S11 is exclusively for connecting control devices as defined in theoperating instructions and not for connecting external con­sumers such as lamps, relays or contactors.
• The devices must be installed in a cabinetwith a protection class of at least IP 54.
Diagramme de fonctionnement avec d´marrage manuel ESR4-NO-21(installation 3).
A1/A2 S12 S31/S22 S34 K1 K2 13/14 23/24 31/32
tM= dur´e mini demaintien, tA1= temps de fonctionnement, tTP= temps dêimpulsion de test, tR= temps derelÜchement, tW= temps der´armement
Diagramme de fonctionnement avec d´marrage automatique ESR4-NM-21 (installation 4).
A1/A2 S12 S31/S22 S35 Blocage (interne) K1 K2 13/14 23/24 31/32
tSP= temps de blocage, tA2= temps defonctionnement, tTP= temps dêimpulsion de test, t
= temps de fonctionnement dublocage, tR= temps de relÜchement,
ASP
tW= temps der´armement
Function diagram for manual start ESR4-NO-21 (Installation 3)
A1/A2 S12 S31/S22 S34 K1 K2 13/14 23/24 31/32
tM= min. ON time, tA1= operate time, tTP= test pulsetime, tR= release time, tW= recovery time
Function diagram for automatic start ESR4-NM-21 (Installation 4)
A1/A2 S12 S31/S22 S35 Lock (internal) K1 K2 13/14 23/24 31/32
tSP= lock time, tA1= operate time, tTP= test pulsetime, t tR= release time,tW= recovery time
= operate time for lock,
ASP
8
5
Page 3
Operating Instruction ESR4-NO-21, ESR4-NM-21
Safety Instructions
Only trainedprofessional electricians may install, startup, modify, and retrofit this equipment! Disconnectthe device / system from allpower sources prior to starting any work! Ifinstallation or system errors occur, line voltagemay be present at the control circuit in devices without DC isolation! Observe all electrical safety regulations issued by the appropriate technical authorities or thetrade association. The safety function can be lost if the device is not used for the intended purpose. Opening the housing or any other manipulation will void the warranty.
Caution!
Perform thefollowing precautionary steps prior toinstallation, assembly, or disassembly:
1. Disconnect supply voltageto the equipment / system prior to starting any work!
2. Lockout/tag the equipment/ system to prevent accidentalactivation!
3. Confirm that no voltage is present!
4. Ground the phasesand short to ground!
5. Protect against adjacent live components using guards and barriers!
6. The devices mustbe installed in a cabinet with a protection class of at least IP 54.
Caution!
Limited contact protection! Protection type according to DIN EN 60529. Housing/terminals:IP40/ IP 20. Finger-proof acc. to DIN VDE 0106 Part 1.
Basic device for Emergency-Stop and Safety Gate Applications
• Basic device to EN 60204-1 and EN 954 -1 for single or dual E-stop monitoring.
• EN954 category 4
• Stopcategory 0 acc. EN 60204-1
• Manual or automatic start
• Crossmonitoring
• Feedback loop to monitoring external contactors
• 2 Enabling paths, 1 signalling path
• Rated voltage in the E-stop circuit DC24 V
• Processingof signals from output switching devices(OSSD) of light curtains acc.DIN EN
61496-1.
• To connect to load side of safety mats acc. DIN EN 1760-1(ESR4-NM-21)
• Debouncingof inputs (ESR4-NM-21)
Front View
Power LED green K1 LED green K2 LED green
Description of Device and Function
ESR4-NO-21 This device is a two-channel safety switching device for emergency stop applications with self-monitoring on each ON-OFF cycle. It conforms to EN 60204-1 and is equipped withpositively driven relays. Basic function: After supply voltage has beenconnected to terminals A1/A2 and the safety inputs closed, operating the reset button closes the enabling current paths (manual start). When the safetyinputs are opened/de-excited the enabling current paths will open.
Operating modes / system functions
• One- or two-channel activation With single-channel activationboth safety channels CH1 and CH2are connected in parallel, withtwo-channel activation they are connected separately.
• Without cross monitoring Both safety channels are connected to positive potential (S12 and S31to S11).
• With cross monitoring Safety channel CH1 is connected to positive potential (S11 to S12) and safety channel CH2 to negative potential (S21 to S22).
• Manual start Whenthe safety inputs are closed, a button is used to open resetinput S34 (triggering withfalling edge) or to close reset input S35 (triggering with risingedge).
• Automatic start Reset input S35 is connected to S33. The device starts with the rising edge of the signal on safety input S12.
• Starting lockout After supply voltage has beenconnected and the safety inputs closed, the enabling pathswill not close. Starting is only possible after the reset buttonhas been operated. For starting lockout the reset inputs have to be activated with the button, as in manual start mode.
• Restarting lockout No restartafter the safety inputshave been opened and closed. Restarting is only possible after the reset button has been operated. For restarting lockout the resetinputs have to be activated with the button, as in manualstart mode.
• OSSD-compatible OSSDsignals from a light barrier or other safety sensors with semiconductor outputscan be processed. Test pulses < tTPdo notinfluence the device functions. Testpulses > tTPcan lockthe device.
• Synchro-check With two-channel activation both safety channels are monitored together with synchronoustime tS. Safety channel CH1 must close before CH2 and bridge S33/S35 must beconnected. If CH2 closes before CH1,the synchronous time tS= ∞.
ESR4-NM-21 The functionscorrespond to those of ESR4-NO-21 without simultaneity monitoring. The deviceis suitable for connecting to short-circuit-forming4-wire switching mats, switching strips andswitching edges (without monitoring resistance). The device must be operated with two channels and cross monitoring. If there is resistance< 50 Ω/channel and ashort circuit between the channels(S11/S12 and S21/S22) the enabling paths open and the SUPPLY LEDflashes. Input debouncingprevents fast consecutive switching ofthe enabling outputs when the safety inputs open for shorter than t paths open after tR. Restartingis prevented for time tSP.
. When the safety inputs open for longer than t
ASP
the enabling
ASP
Please observeinstructions from safety authorities.
Caract´ristiques techniques Circuit dèalimentation ESR4-NO-21 ESR4-NM-21
Tension nominaleU Puissance assign´e DC 2,0 W 2,1 W Puissance assign´e AC 2,4 W / 4,4 VA 2,5 W/ 4,6 VA Ondulation r´siduelle 2,4 V Fr´quence nominale 50 ... 60 Hz Plage de la tension de service 0,85 ... 1,1 x U Fusible pour alimentation circuit de commande r´sistant aux courts-circuits (r´sistance
Circuit de commande
Tension de sortie nominale S11, S33 contreS21 DC 22 V Courant de sortie / courant de pointe 100mA / 2000 mA 100mA / 200 mA Plage de la tension dêentr´e
High (haut) DC 17,4V a DC26,4 V
Low (bas) DC ô 3,0V a DC+5,0 V Courant nominal/ courant de pointe S12, S31/S22 40 mA/ 100 mA Courant nominal/ courant de pointe S34, S35 5 mA / 50mA Temps dêimpulsion de test admis tTP/ fr´quence de test ≤ 1000µs / ≤ 10 s Temps defonctionnement tA1S34 20 ms a 40 ms Temps defonctionnement tA2S35 200 ms a 500 ms 20 msa 80 ms Dur´e minide maintien tMS34, S35 > 50 ms Temps deblocage t Temps defonctionnement du blocage t Temps der´armementt Temps derelÜchement tRK1, K2 < 25 ms Temps decontro le du d´synchronisme ≈ 200 ms --
Circuit de sortie
Contacts de sortie
Equipement des contacts 2 contactsde travail, a guidage forc´ Tension nominalede coupure U Courant continumax. Inpour chaque contact 6 A Courant totalmax. de tous les contacts 12 A
Dur´e de vie m´canique 10 x106commutations
Contacts de signalisation
Equipement des contacts 1 contact de rupture, paralle le,a guidage forc´ Tension nominalede coupure U Courant continumax. Inpour chaque contact 6 A
Dur´e de vie m´canique 10 x106commutations
Caract´ristiques g´n´rales
Cheminements et claquage entre les circuits ´lectriques selon DIN VDE 0110 partie 1 :04.97 Surtension transitoireassign´e 4kV Degr´depollution de lêappareil: a lêint´rieur / a lêext´rieur 2 / 3 Tension assign´e AC300 V Classe de protection selon DIN VDE 0470 partie 1 : Boıtier / bornes Temp´rature ambiante / de stockage -25 ... +55 / -25 ... +75 ² C Poids 0,21 kg
Donn´es sur les bornes et les connexions
Unifilaire(fil rigide) ou fils de faiblediame tre (multibrins) 1 x 0,14 mmè a 2,5 mmè 2x 0,14 mmè a 0,75mmè Longueur de d´nudation max. 8 mm Fil a faible diame tre(multibrins) avec embout selonDIN 46228 Couple de serrage max. 0,5 a 0,6 Nm
N
PTC)
SP
W
ASP
n
n
--- 70 ms a 130 ms
--- > 7 ms
≥ 40ms ≥ 150 ms
AC-15 : Ue 230 V, Ie 4 A (360 h-1) DC-13:Ue 24 V,Ie 4 A (360 h-1)Cat´gorie dêutilisation selon IEC 947 - 5 - 1
AC-15 : Ue 230 V, Ie 3 A (3600 h-1) DC-13: Ue 24 V, Ie 2,5 A (3600h-1)
AC-15 : Ue 230 V, Ie 4 A (360 h-1) DC-13:Ue 24 V,Ie 4 A (360 h-1)Cat´gorie dêutilisation selon IEC 947 - 5 - 1
AC-15 : Ue 230 V, Ie 3 A (3600 h-1) DC-13: Ue 24 V, Ie 2,5 A (3600h-1)
1 x 0,25 mmè a 2,5 mmè 2x 0,25 mmè a 0,5 mmè
AC/DC 24 V
SS
r´sistant aux courts-circuits (fusible
AC240 V / DC 300 V
AC240 V / DC 300 V
IP 40 / IP 20
N
´lectronique)
-1
4
9
Page 4
Anschlussschaltbild / Connection Diagram/ Sch´ma de connexion
Installation
Beachten Sie bei der Installati­on dasAnschlussschaltbild.
1 Not-Aus, einkanalig mit
manuellem Start
1.1 RESET(mit Reset­Taster-U berwachung S34)
1.2 Brucke Jumper Pont
2 OSSD-Ansteuerung,
zweikanalig nicht
querschluäerkennend
2.1 Brucke, RESET mit automatischen Start
2.2 Brucke, CH2- Jumper, CH2- Pont, CH2-
3 Not-Aus, zweikanalig
querschluäerkennend mit manuellem Start
3.1 RESET (mit Reset-Taster­U berwachung S34)
3.2 Brucke, CH2+ Jumper, CH2+ Pont, CH2+
4 Schutztu r-Anwendung,
zweikanalig
querschlusserkennend, Synchronuberwachung (S1 mussvor S2 betÖtigt werden)
4.1 RESETmit automatischem Start
4.2 Brucke, CH2+ Jumper, CH2+ Pont, CH2+
5 2Freigabestrompfade,
1 Meldekontakt
6 Versorgungsspannung PowerSupply Tension nominale de
Pleaseconsult the con­nectiondiagram during installation
Emergency stop, single-channel with
manual start RESET(with reset button monitoring S34)
OSSD controlling, two­channel, nocross
monitoring Jumper, RESET with automatic start
Emergency stop, two­channel, cross
monitoring, with manual start RESET (with reset button monitoring S34)
Safety gate application, two-channel, cross
monitoring, synchronous monitoring (operating S1 before S2)
RESETwith automatic start
2 enabling current paths, 1 signalling contact
Lors delêinstallation, respec­ter lesch´ma des connexions.
Arr’ t düurgence, monocanal avec d´marrage
manuel RESET (avec auto-contro le du bouton-poussoir de validation S34).
Commande OSSD, a deux canaux sansd´tectionde
courts-circuits. Pont, RESETavec d´marrage automatique
Arr’ t düurgence, a deux canaux avecd´tectionde
courts-circuits eta d´marrage manuel RESET (avec auto-contro le du bouton-poussoir de validation S34).
Application pour porte de protection, a deux canaux,
avec d´tection de courts- circuits, controledu d´synchronisme (S1doit ‘ tre activ´avantS2) RESET avec d´marrage automatique
2 contactsde sortie, 1 contact de signalisation
lêappareil
Technische Daten Versorgungskreis ESR4-NO-21 ESR4-NM-21
Nennspannung U Bemessungsleistung DC 2,0 W 2,1 W Bemessungsleistung AC 2,4 W / 4,4 VA 2,5 W / 4,6VA Restwelligkeit 2,4 V Nennfrequenz 50 ... 60 Hz Betriebsspannungsbereich 0,85 ... 1,1x U Sicherung fur Steuerkreisversorgung kurzschlussfest (PTC-Widerstand) kurzschlussfest
Steuerkreis
Nennausgangsspannung S11, S33 gegen S21 DC 22 V Ausgangsstrom / Spitzenstrom 100 mA/ 2000 mA 100 mA / 200 mA Eingangsspannungsbereich
High DC 17,4 V bis DC 26,4 V
Low DC -3,0 V bis DC+5,0 V Nennstrom / Spitzenstrom S12, S31/S22 40mA / 100 mA Nennstrom / Spitzenstrom S34, S35 5 mA/ 50 mA zulÖssige Testpulszeit tTP/ TesthÖufigkeit ≤1000 µs / ≤ 10 s Ansprechzeit tA1S34 20 ms bis 40ms Ansprechzeit tA2S35 200ms bis 500 ms 20 ms bis 80 ms Mindesteinschaltdauer tMS34, S35 > 50 ms Sperrzeit t Ansprechzeit der Sperre t Wiederbereitschaftszeitt RuckfallzeittRK1, K2 < 25 ms Synchronuberwachungszeit t
Ausgangskreis
Freigabepfade
Kontaktbestuckung 2Schlieä er,zwangsgefuhrt Schaltnennspannung U max. DauerstromInpro Strompfad 6 A max. Summenstromaller Strompfade 12 A
Mechanische Lebensdauer 10 x106Schaltungen
Meldepfade
Kontaktbestuckung 1 O ffner, parallel, zwangsgefuhrt Schaltnennspannung U max. DauerstromInpro Strompfad 6 A
Mechanische Lebensdauer 10 x106Schaltungen
Allgemeine Daten
Luft- und Kriechstrecken zwischen den Stromkreisen nach DIN VDE 0110 Teil-1 : 04.97 Bemessungsstoäspannung 4kV Verschmutzungsgrad des GerÖtes: innerhalb / auäerhalb 2 / 3 Bemessungsspannung AC300 V Schutzart nach DIN VDE 0470 Teil 1: GehÖuse / Klemmen IP40 / IP 20 Umgebungs-/Lagertemperatur -25 ... +55 / -25 ... +75 ² C Gewicht 0,21 kg
Klemmen- und Anschlussdaten
EindrÖhtig oder feindrÖhtig 1 x 0,14 mmè bis 2,5 mmè 2x 0,14 mmè bis 0,75 mmè AbisolierlÖnge max. 8 mm FeindrÖhtig mitAderendhulse nach DIN 46228 1 x 0,25 mmè bis 2,5 mmè 2 x 0,25 mmè bis 0,5 mmè Maximales Anzugsdrehmoment 0,5 bis 0,6Nm
N
SP
ASP
W
S
n
AC-15: Ue 230 V, Ie 3 A (3600 h-1) DC-13: Ue24 V, Ie 2,5 A(3600 h-1)
n
AC-15: Ue 230 V, Ie 3 A (3600 h-1) DC-13: Ue24 V, Ie 2,5 A(3600 h-1)
--- 70 ms bis 130 ms
--- > 7 ms
≥ 40ms ≥ 150 ms
ca. 200ms --
AC-15:Ue 230 V, Ie 4 A (360 h-1) DC-13: Ue 24 V, Ie 4 A(360 h-1)Gebrauchskategorie nachIEC 947 - 5 - 1
AC-15:Ue 230 V, Ie 4 A (360 h-1) DC-13: Ue 24 V, Ie 4 A(360 h-1)Gebrauchskategorie nachIEC 947 - 5 - 1
AC/DC 24 V
SS
N
(elektronische Sicherung)
-1
AC240 V / DC 300 V
AC240 V / DC 300 V
10
3
Page 5
Bestimmungsgema üe Verwendung
DieGerÖtesindSicherheits-SchaltgerÖte.SiedurfennuralsTeilvonSchutzeinrichtungenanMaschinenzumZweck desPersonen-,Material-und Maschinenschutzeseingesetztwerden.
Hinweise
• DieSicherheits-KategorienachEN 954-1hÖngtvonderAuäenbeschaltung,der WahlderBefehlsgeberundderenÄrtlicherAnordnungan derMaschine ab.
• GrundsÖtzlich sind beim Betrieb des GerÖtes die angegebenen Zeiten einzuhalten, ansonsten kann eszur Verriegelung des GerÖtes kommen. Die Verriegelung kann durch ordnungsgemÖäes O ffnen der SicherheitseingÖnge aufgehoben werden.
• Zur VervielfÖltigung der Freigabestrompfade kÄnnen dieErweiterungsgerÖte der Reihe SNE oder externeSchutze mit zwangsgefuhrten Kontakten eingesetzt werden.
• Das GerÖt und die Kontakte mussen mit maximal 6 A Betriebsklasse gG abgesichert werden.
• Die GerÖte sind mit einem U berlastschutz (bei Kurzschluss) ausgerustet. Nach Beseitigung derStÄrungsursache ist das GerÖt nach ca. 3 s
wieder betriebsbereit.
• Der Steuerausgang S11 dient ausschlieälich dem Anschluss von Befehlsgebernlaut Gebrauchsanweisung und nicht dem Anschluss externer Verbraucher, wie z.B. Lampen, Relais oder Schutzen.
• Der Einbau der GerÖte muss in einemSchaltschrank mit einer Schutzart von mindestens IP 54 erfolgen.
Funktionsdiagramm bei manuellem Start ESR4-NO-21 (Installation 3)
A1/A2 S12 S31/S22 S34 K1 K2 13/14 23/24 31/32
tM= Mindesteinschaltzeit, tA1= Ansprechzeit, tTP= Testpulszeit, tR= Ruckfallzeit, tW= Wiederbereitschaftszeit
Funktionsdiagramm bei automatischem Start ESR4-NM-21 (Installation 4)
A1/A2 S12 S31/S22 S35 Sperre (intern) K1 K2 13/14 23/24 31/32
tSP= Sperrzeit, tA2= Ansprechzeit, tTP= Testpulszeit, t Sperre,tR= Ruckfallzeit, tW= Wiederbereitschaftszeit
= Ansprechzeit der
ASP
Montage, Assembly, Montage
Demontage, Disassembly, D´montage
Abmessungen / Dimension Diagram / Dimensions
1 1 1
Relais aufdie Hutschiene einhÖngen.
2 2 2
Durch leichtenDruck in Pfeilrichtung Relais auf die Hutschiene aufschnappen.
3 3 3
Relais in Pfeilrichtung herunterdrucken.
4 4 4
Im heruntergedruckten Zustand Relaisin Pfeilrichtung aus derVerrastung lÄsen und von derHutschiene nehmen.
Attach relay to DIN rail. Posezle relais sur le rail DIN.
Press therelay carefully onto the DINrail (in direction of arrow) until it locks into place.
Push relay down (in direction of arrow)
Release relay and remove it from the DIN rail (see arrow)
Appuyezle relais l´ge rement contre le rail DIN (en direction de la fle che).
Appuyezsur le relais (en direction de la fle che).
D´verrouillez le relais et retirez-le du rail DIN (voir la fle che).
2
11
Page 6
Gebrauchsanweisung
08/03 AWA 2131-1741 / GA 0135-1003-03
ESR4-NO-21, ESR4-NM-21
Basisgera t fu r Not-Aus- und Schutztu r-Anwendungen
• BasisgerÖt nach EN 60204-1 und EN 954-1 fur ein- oder zweikanalige Not-Aus- U berwachung.
• EN 954 Kategorie 4
• Stop-Kategorie 0 gemÖä EN 60204-1
• Manueller oder automatischer Start
• Mit / ohne Querschlusserkennung
• Ruckfuhrkreis zurU berwachungexterner Schutze
• 2 Freigabestrompfade, 1 Meldestrompfad
• Zur Verarbeitungvon Signalen aus den Ausgangsschaltelementen (OSSD) eines
Lichtgitters gemÖä DIN EN 61496-1
• Zur Nachschaltungan eine Schaltmatte gemÖä DIN EN 1760-1 (ESR4-NM-21)
• Eingangsentprellung (ESR4-NM-21)
Frontansicht
Power LED grun K1 LED grun K2 LED grun
Anderungen vorbehalten / Subject to changes / Sous r´serve de modification
Copyright 2003 Moeller GmbH, 53105 Bonn
12
Printed in the Federal Republic of Germany
08/03 AWA 2131-1741 GA 0135-1003-03
Sicherheitsbestimmungen
Die Montage,Inbetriebnahme, Anderungund Nachrustung darf nur von einer Elektrofachkraft ausgefuhrt werden! Schalten Sie das GerÖt / die Anlage vor Beginn der Arbeiten spannungsfrei! Bei Installations- und Anlagenfehlern kann bei nicht galvanischgetrennten GerÖten auf dem Steuerkreis Netzpotentialanliegen! Beachten Sie fur die Installation der GerÖte die Sicherheitsvorschriftender Elektrotechnik und der Berufsgenossenschaft. Durch O ffnen des GehÖusesoder sonstige Manipulation erlischt jegliche GewÖhrleistung.
Achtung!
Fuhren Sievor Beginn der Installation/ Montage oder Demontage folgende Sicherheitsmaänahmen durch:
1. Schalten Sie das GerÖt / die Anlage vor Beginnder Arbeiten spannungsfrei!
2. Sichern Sie die Maschine/ Anlage gegen Wiedereinschalten!
3. Stellen Sie die Spannungsfreiheit fest!
4. Erden Sie die Phasen und schlieäen Sie diese kurz!
5. Decken und schranken Sie benachbarte, unter Spannungstehende Teile ab!
6. Der Einbau derGerÖte muss in einem Schaltschrank mit einer Schutzart von mindestens IP 54 erfolgen.
Achtung!
EingeschrÖnkter Beruhrungsschutz!Schutzart nach DIN EN 60529. GehÖuse/Klemmen:IP40/ IP 20. Fingersicher nachDIN VDE 0106 Teil 1.
Gera te- und Funktionsbeschreibung
ESR4-NO-21 Das GerÖt ist ein zweikanaliges, bei jedem EIN-AUS-Zyklussich selbst uberwachendes SicherheitsschaltgerÖtfur Not-Aus-Einrichtungen nach EN 60204-1, welches mit zwangsgefuhrten Relais ausgestattet ist.
Grundfunktion: Nach Anlegen der Versorgungsspannung an die KlemmenA1/A2 und geschlossenen SicherheitseingÖngen werden mit der BetÖtigung des Reset-Tasters (manueller Start) die Freigabestrompfade geschlossen. Beim O ffnen/Entregen der SicherheitseingÖnge werden dieFreigabestrompfade geÄffnet.
Betriebsarten / Systemfunktionen
• Ein- oder zweikanalige Ansteuerung Bei einkanaliger Ansteuerung werdendie beiden SicherheitskanÖle CH1und CH2 parallel und bei zweikanaliger Ansteuerung getrennt geschaltet.
• Ohne Querschlusserkennung Beide SicherheitskanÖle werden gegen Pluspotential geschaltet (S12 und S31 auf S11).
• Mit Querschlusserkennung Der Sicherheitskanal CH1 wird gegen Pluspotential (S11 auf S12) und der Sicherheitskanal CH2 gegen Minuspotential(S21 auf S22) geschaltet.
• Manueller Start Mittels eines Tasters wird, beigeschlossenen SicherheitseingÖngen, der Reseteingang S34geÄffnet (Triggerung mit fallender Flanke) oder der Reseteingang S35 geschlossen (Triggerungmit steigender Flanke).
• Automatischer Start Der Reseteingang S35 wird mit S33 verbunden. Das GerÖt startet mit der steigendenFlanke des Signals am SicherheitseingangS12.
• Anlaufsperre BeimAnlegen der Versorgungsspannung und geschlossenen SicherheitseingÖngen werdendie Freigabepfade nicht geschlossen. Der Anlauf kann nur nach derBetÖtigung des Reset-Tasters erreicht werden. Fur die Anlaufsperre sind, wie bei der BetriebsartManueller Start, die ReseteingÖnge mit Taster anzusteuern.
• Wiederanlaufsperre NachO ffnen und Schlieäen der SicherheitseingÖngeerfolgt kein erneuter Anlauf. Der Wiederanlauf kann nur nach der BetÖtigung des Reset-Tasters erreicht werden. Furdie Wiederanlaufsperre sind, wie bei der Betriebsart Manueller Start, die ReseteingÖnge mit Taster anzusteuern.
• OSSD-kompatibel Ausgangsschaltelementen(OSSD) einer Lichtschranke oder anderer Sicherheitssensoren mit Halbleiter-AusgÖngen kÄnnen verarbeitet werden. Testpulse die < tTPsind, beeinflussendie GerÖtefunktionen nicht. Bei Testpulsen> tTPkann das GerÖt verriegeln.
• Synchronu berwachung Bei zweikanaliger Ansteuerung werden beide SicherheitskanÖle gegeneinander mitder Synchronzeit tSuberwacht. SicherheitskanalCH1 muä vor CH2 schlieäen und die Brucke S33/S35 muä geschaltet sein. Schlieät CH2 vor CH1, betrÖgt die Synchronzeit tS= ∞, die Synchronuberwachung ist abgeschaltet.
ESR4-NM-21 Die Funktionentspricht der des ESR4-NO-21 ohne Synchronuberwachung. Das GerÖt istzur Nachschaltung an kurzschlussbildenden Schaltmatten, Schaltleisten oder Schaltkanten in 4-Leiter-Technik(ohne U berwachungswiderstand)geeignet. Das GerÖt muä zweikanalig mit Querschlusserkennung betrieben werden. Bei einemWiderstand < 50 Ω/Kanal und einemKurzschluss zwischen den KanÖlen (S11/S12 und S21/S22) Äffnen die Freigabepfade, die LEDSUPPLY blinkt. Eine Eingangsentprellung verhindert einschnelles aufeinanderfolgendes Schalten der Freigabestrompfade, wenn die SicherheitseingÖnge kurzer alst LÖnger alst tR. DasWiedereinschalten wird fur die ZeittSPgesperrt. Bei Anwendungenfur taktile Betriebsarten (schnelle Aus/Ein-Zyklen z.B.bei manuellen Zufuhrungen) wird das ESR4-NM-21 mit Eingangsentprellung empfohlen.
geÄffneteSicherheitseingÖnge, fuhren zum O ffnen der Freigabestrompfade nach
ASP
geÄffnetwerden.
ASP
Bitte beachten Sie auch die Informationen Ihrer Berufsgenossenschaft!