Wiring with easy
78
05/04 AWB2528-1508GB
Coils
Coils are the actuating mechanisms of relays. In RUN mode,
the results of the wiring are sent to the coils, which switch
on or off accordingly. Coils can have seven different coil
functions.
Table 6: Usable contacts
easy works with different contacts, which can be used in any
order in the contact fields of the circuit diagram.
Table 7: Contacts
Contact
easy representation
Make contact
Open in the rest state
I, Q, M, N, A, Ö, Y, C, T, O, P, :,
D, S, R, Z
Break contact
Closed in the rest state
i, q, m, , a, ö, , c, t, , p, ,
, ,
N Y O D
S R Z
h
To ensure compatibility with easy400 and easy600
devices, each easy500 and easy700 is provided logically
with all possible contacts. If contacts are not supported by
the device, i.e. devices without a clock, their switching
state is always zero. The contacts (make contact) of the
time switches are always set to logic 0.
The advantage of this process is that you can use the same
circuit diagram on all easy500, easy700, easy-AB, easyAC, easy-DA and easy-DC devices.
Contact type Make
contact
Break
contact
easy500 easy700 Page
Analog value comparator function
relay
A a A1…A16 A1…A16 104
Counter function relay
C c C1…C16 C1…C16 117
Text marker function relay
D D1…D16 D1…D16 137
7-day time switch function relay
Ö ö Ö1…Ö8 Ö1…Ö8 143
D