Mody Pumps NC-06360, NC-08360, NC-10360-M User Manual

MODELS: NC 06360/08360/10360-M
OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE
MANUAL INCLUDING SPARE PARTS LIST
Mody Pumps Inc.
Bakersfield, CA 93308
Tel.: (661) 392-7600 FAX.: (661) 392-7601
E-Mail: sales@modypump.com
http://www.modypump.com
2166 Zeus Court
LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY
1. Most accidents can be avoided by using COMMON SENSE.
2. Please read the operation and maintenance instruction manual supplied with the pump. If you did not receive one, please call your local distributor before pump installation.
3. Do not wear loose apparel that may become entangled in the impeller or other moving parts.
4. Always use appropriate safety equipment, such as safety glasses, when working on the pump or piping.
5. Pumps build up heat and pressure during operation-allow time for pumps to cool before handling or servicing.
6. Only qualified service personnel should install, operate and repair pump.
7. Keep clear of suction and discharge openings. DO NOT insert fingers in pump with power connected.
8. Do not pump flammable or hazardous materials (gasoline, acids, alkalis, etc.)
9. Do not block or restrict discharge hose, as it may whip or burst catastrophically under pressure.
10. Make sure lifting handles/hooks are securely fastened each time before lifting.
11. Do not lift pump by the power cord under any circumstances.
12. Do not exceed manufacturer's recommendation for optimum performance, as this could cause the motor/pump to overheat and lead to premature wear or failure.
13. Secure the pump in its operating position so it does not tip over, fall or slide.
14. Keep away from impeller when power is connected.
15. Submersible Pumps are not approved for use in swimming pools, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common.
16. Do not operate pump without adequate protection and safety devices in place.
17. Always replace safety devices that have been removed during service or repair.
18. To reduce risk of electrical shock, pump must be properly grounded in accordance with the National Electric Code and all applicable state and local codes and ordinances.
19. To reduce risk of electrical shock, always disconnect the pump from the power
source before handling or servicing.
20. Any wiring of pumps should be performed by a qualified electrician.
21. Never operate a pump with a power cord that has frayed or brittle insulation.
22. Cable should be protected at all times to avoid punctures, cuts, and
abrasions - inspect frequently.
23. Never handle connected - "hot" power cords with wet hands.
24. Never operate a pump with a plug-in type power cord without a ground fault circuit interrupter, adequate overload and short circuit protection.
IMPORTANT !!! MODY Pumps Inc. is not responsible for losses, injury, or death resulting from a failure to observe these safety precautions, misuse or abuse of pumps or equipment.
Mody Pumps Inc.
:
2166 Zeus Court, Bakersfield, CA 93308 Tel.: (661) 392-7600 Fax: (661) 392-7601
GENERAL INFORMATION.
THE
“mody” NC-M SERIES LINE OF SUBMERSIBLE PUMPS ARE PRIMARILY DESIGNED FOR
HANDLING SLUDGE AND SOLIDS. THEY CAN ALSO BE USED FOR HANDLING WASTE WATER, FLY ASH, CERAMIC SLIP AND IN OTHER ALLIED APPLICATIONS WHERE THE CONCENTRATION OF SUSPENDED SOLIDS IS HIGH.
THE SERVICE LIFE OF A SUBMERSIBLE PUMP DEPENDS MAINLY ON TWO THINGS: THE DEPENDABILITY OF THE SEALING SYSTEM AND THE WEAR RESISTANCE OF THE PUMP ITSELF.
IN THE NC-M SERIES PUMPS, THE WEAR PLATE IS RUBBERLINED WHILE THE VOLUTE AND IMPELLER ARE MADE OF CAST STAINLESS STEEL. THE IMPELLER IS A RECESSED VORTEX DESIGN THAT ALLOWS THE PUMP TO HANDLE 2 1/2" SPHERICAL SOLIDS. ALL LARGE PARTICLES ARE SUCKED IN USING THE VORTEX CREATED BY THE IMPELLER AND PASS OUT DIRECTLY THROUGH THE DISCHARGE.
ALL MODELS HAVE BUILT-IN THERMAL PROTECTION, WHICH CAN BE AUGMENTED WITH AN OVERCURRENT RELAY. IT IS HOWEVER RECOMMENDED THAT IRRESPECTIVE OF TYPE OF PUMP,
ADEQUATE MOTOR PROTECTION SWITCHGEAR SHOULD BE USED AT THE INSTALLATION. WE STRONGLY RECOMMEND THE USE OF SUITABLE CONTROL PANELS WHICH ARE AVAILABLE FROM US INCORPORATING ALL REQUIRED PROTECTION.
IT IS IN THE INTEREST OF THE USER THAT HE GO THROUGH THIS MANUAL IN DETAIL PRIOR TO USING THE PUMP. THIS MANUAL WILL HELP HIM UNDERSTAND THE CONSTRUCTIONAL FEATURES AND TO OBTAIN TROUBLE FREE SERVICE FROM THE PUMP.
TECHNICAL DESCRIPTION
THE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING EASY AND SIMPLE SERVICEABILITY. THE MAJOR DESIGN FEATURES ARE AS UNDER:
A] THERMAL PROTECTION: SEE UNDER "MOTOR PROTECTION"
B] THE MOTOR: A RUGGED ALUMINUM DIE CAST ROTOR, DYNAMICALLY BALANCED TO GRADE
2.5 ACCURACY OF ISO 942. A STAINLESS STEEL SHAFT RUNNING IN TWO DEEP GROOVE BALL BEARINGS. INSULATION CLASS "F" (155 DEGREES CELSIUS). END WINDINGS DULY EPOXY COATED TO PREVENT DETERIORATION OF INSULATION EVEN IN EXTREMELY HUMID CONDITIONS. WINDING WIRE IS DUAL COATED SUITABLE FOR "H" CLASS INSULATION.
C] THE SEAL CHAMBER: THE HEART OF THE "MODY" PUMP. DUAL MECHANICAL SEALS, TUNGSTEN CARBIDE V/S TUNGSTEN CARBIDE SEAL FACES (LOWER SEAL) AND TUNGSTEN CARBIDE V/S TUNGSTEN CARBIDE (UPPER SEAL). SECONDARY SEALS OF HNBR RUBBER AND METAL PARTS IN STAINLESS STEEL, RUNNING IN AN OIL BATH, ENCLOSED IN A PRESSURE COMPENSATING RUBBER BAG - CREATES THE ULTIMATE SEAL SOLUTION. THE DESIGN OPTIMIZES SEAL LIFE AND ALLOWS FOR SIX MONTHLY (2500 HRS) SERVICE INTERVALS.
D] BEARINGS: SINGLE ROW DEEP GROOVE BALL BEARING (UPPER), DOUBLE ROW ANGULAR CONTACT BEARING (LOWER) SEALED FOR LIFE WITH A SPECIAL HIGH TEMPERATURE BEARING GREASE REQUIRING NO PERIODIC MAINTENANCE WHATSOEVER.
E] THE HYDRAULIC ELEMENTS : A RECESSED VORTEX STAINLESS STEEL IMPELLER (AVAILABLE IN CORROSION RESISTANT 304 SS OR IN ABRASION RESISTANT 410 HARDENED SS RUNNING AGAINST A RUBBERLINED WEAR PLATE. THE VOLUTE IS STAINLESS STEEL OF AISI 304 QUALITY, DESIGNED FOR LARGE SOLID HANDLING CAPACITY OF 2 1/2"
.
F] CABLE GLAND ASSEMBLY: THE PUMP IS SUPPLIED WITH 50 FEET CABLE AS STANDARD. THE CABLE IS A 4 CORE EPR SHEATHED AND INSULATED CONFORMING TO INT'L STD. THE CABLE IS WATERPROOF AND CAN BE COMPLETELY SUBMERGED IN WATER. THE CABLE IS TERMINATED IN THE PUMP AT THE CABLE GLAND. THE GLAND ASSEMBLY SEALS THE CABLE ON THE OUTSIDE SHEATH. A WATER DAM ARRANGEMENT IS ALSO PROVIDED WHICH SEALS THE INDIVIDUAL CORES OF THE CABLE. THIS FEATURE IS UNIQUE AND IS ESSENTIAL TO PREVENT WATER SEEPING THROUGH THE CORES OF THE CABLE INTO THE TERMINAL CHAMBER IN THE EVENT OF A CUT CABLE. THE CABLE IS ALSO SHEATHED FOR THE FIRST ONE METER BY MEANS OF A CABLE GRIP MADE OF STAINLESS STEEL. THIS IS ESSENTIAL TO ENSURE THAT THERE IS NO UNDUE STRAIN ON THE CABLE IF THE PUMP IS PULLED OR LOWERED INADVERTENTLY BY MEANS OF THE CABLE. COMPLETE DETAILS OF THE CABLE GLAND ASSEMBLY ARE SHOWN IN THE DRAWING.
G] ELECTRICAL INFORMATION: MOTORS ARE TYPICALLY DESIGNED TO OPERATE ON 230/460V AT 60 HZ. EXPORT DESTINED PUMPS ARE PREWIRED FOR SINGLE VOLTAGE AND FREQUENCY. MAXIMUM DEVIATION IN VOLTAGE ALLOWED IS -/+ 6% AND FREQUENCY -/+ 3%. CHECK NAME PLATE FOR OPERATING VOLTAGE AND FREQUENCY.
INSTALLATION.
CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP.
CHECK THAT FUSES ARE INTACT.
USE SHORTEST POSSIBLE HOSE IN RECOMMENDED DIMENSION. AVOID SHARP BENDS,
CREASES, AND CONTRACTIONS.
THE MAXIMUM SUBMERGENCE RECOMMENDED IS 50 FEET.
THE SPECIFIC GRAVITY OF THE PUMPED FLUID SHOULD NOT EXCEED 1.1.
NEVER LIFT OR PULL THE PUMP BY MEANS OF THE CABLE. SUSPEND THE PUMP BY A
ROPE OR PREFERABLY PLACE IT ON A SOLID BASE.
WIRE THE PUMP TO THE MAINS CORRECTLY. ALWAYS USE A STARTER OR A PANEL BOARD. SEE INSTRUCTIONS UNDER "MOTOR PROTECTION" BELOW.
AT THE STARTING MOMENT, THE PUMP SHALL MAKE A KICK, WHICH IS OPPOSITE TO THE DIRECTION OF ROTATION OF THE IMPELLER. SHIFT TWO PHASES IN THE POWER CONNECTION IF THE KICK IS IN THE WRONG DIRECTION. THE CORRECT DIRECTION IS INDICATED ON THE PUMP COVER AT THE TOP OF THE PUMP.
CHECK LEVEL AND CONDITION OF THE OIL AT SERVICE EVERY SIX MONTHS. IF THE OIL IS EMULSIFIED BY WATER THE SEALS MUST BE REPLACED.
THE SHAFT SEAL SHOULD BE CHECKED FOR WEAR EVERY 2500 HRS. OF OPERATION. IF SEAL FACES SHOW ANY SIGNS OF WEAR, THEY SHOULD BE REPLACED. REFER TO PAGE 5 FOR SERVICING THE PUMP SEALS.
HRC FUSE RECOMMENDED
MAINS VOLTAGE AT SITE NC06 M NC08 M NC10 M
220 VOLTS 3 PHASE 25 AMPS 30 AMPS 40 AMPS 380 VOLTS 3 PHASE 16 AMPS 20 AMPS 25 AMPS 415 VOLTS 3 PHASE 16 AMPS 16 AMPS 25 AMPS 460 VOLTS 3 PHASE 16 AMPS 16 AMPS 25 AMPS