1. Most accidents can be avoided by using COMMON SENSE.
2. Please read the operation and maintenance instruction manual supplied with the
pump. If you did not receive one, please call your local distributor before pump
installation.
3. Do not wear loose apparel that may become entangled in the impeller or other
moving parts.
4. Always use appropriate safety equipment, such as safety glasses, when working
on the pump or piping.
5. Pumps build up heat and pressure during operation-allow time for pumps to cool
before handling or servicing.
6. Only qualified service personnel should install, operate and repair pump.
7. Keep clear of suction and discharge openings. DO NOT insert fingers in pump
with power connected.
8. Do not pump flammable or hazardous materials (gasoline, acids, alkalis, etc.)
9. Do not block or restrict discharge hose, as it may whip or burst catastrophically
under pressure.
10. Make sure lifting handles/hooks are securely fastened each time before lifting.
11. Do not lift pump by the power cord under any circumstances.
12. Do not exceed manufacturer's recommendation for optimum performance, as this
could cause the motor/pump to overheat and lead to premature wear or failure.
13. Secure the pump in its operating position so it does not tip over, fall or slide.
14. Keep away from impeller when power is connected.
15. Submersible Pumps are not approved for use in swimming pools, recreational
water installations, decorative fountains or any installation where human contact
with the pumped fluid is common.
16. Do not operate pump without adequate protection and safety devices in place.
17. Always replace safety devices that have been removed during service or repair.
18. To reduce risk of electrical shock, pump must be properly grounded in
accordance with the National Electric Code and all applicable state and local
codes and ordinances.
19. To reduce risk of electrical shock, always disconnect the pump from the power
source before handling or servicing.
20. Any wiring of pumps should be performed by a qualified electrician.
21. Never operate a pump with a power cord that has frayed or brittle insulation.
22. Cable should be protected at all times to avoid punctures, cuts, and
abrasions - inspect frequently.
23. Never handle connected - "hot" power cords with wet hands.
24. Never operate a pump with a plug-in type power cord without a ground fault
circuit interrupter, adequate overload and short circuit protection.
IMPORTANT !!! Mody Pumps Inc. is not responsible for losses, injury, or death resulting
from a failure to observe these safety precautions, misuse or abuse of pumps or
equipment.
Mody Pumps Inc.: 2166 Zeus Court, Bakersfield, CA 93308 Tel.: (661) 392-7600 Fax: (661) 392-7601
GENERAL INFORMATION.
“MS” SERIES OF MODY'S SUBMERSIBLE SEWAGE PUMPS ARE PRIMARILY DESIGNED FOR
THE
HANDLING SEWAGE, SLUDGE, SLURRIES, WASTEWATER AND LIQUID MANURE. THEY CAN ALSO
BE USED FOR HANDLING STORMWATER DRAINAGE WITH HIGH SOLIDS CONTENT.
THE SERVICE LIFE OF A SUBMERSIBLE PUMP PRIMARILY HINGES ON TWO ASPECTS: THE
DEPENDABILITY OF THE SEALING SYSTEM AND THE WEAR RESISTANCE OF THE PUMP ITSELF.
THE “MS” SERIES OF PUMPS ARE AVAILABLE WITH A WIDE RANGE OF IMPELLERS TO SUIT
PRACTICALLY EVERY PUMPING DUTY WITH HIGH EFFICIENCES. THE MS 6100 & 6200
HAVE THREE MODELS AS UNDER :
1. MS 6152 15HP SINGLE CHANNEL IMPELLER WITH 100MM/4” SOLID HANDLING CAPACITY.
2. MS 6202 20HP SINGLE CHANNEL IMPELLER WITH 100MM/4” SOLID HANDLING CAPACITY.
THE SINGLE CHANNEL IMPELLERS ARE IN CAST IRON CONSTRUCTION. THE PUMP VOLUTES
ARE ALSO IN CAST IRON WITH SMOOTH PROFILED GEOMETRY FOR CLOG FREE OPERATION AND
HIGH EFFICIENCES. STAINLESS STEEL CONSTRUCTION AVAILABLE. ALL VOLUTES ARE
FITTED WITH REPLACEABLE WEAR RINGS.
IT IS IN THE INTEREST OF THE USER THAT HE/SHE GO THROUGH THIS MANUAL IN DETAIL
PRIOR TO USING THE PUMP.
TECHNICAL DESCRIPTION.
THE PUMPSET IS IN A MODULAR CONSTRUCTION ENSURING EASY AND SIMPLE
SERVICEABILITY. THE MAJOR DESIGN FEATURES ARE AS UNDER:
A] THERMAL PROTECTION : SEE UNDER "MOTOR PROTECTION" .
B] THE MOTOR: A RUGGED ALUMINUM DIE CAST ROTOR, DYNAMICALLY BALANCED TO GRADE
2.5 ACCURACY OF ISO 942. A STAINLESS STEEL SHAFT RUNNING IN TWO DEEP GROOVE
BALL BEARINGS. INSULATION CLASS "H" (180 DEGREES CELSIUS). END WINDINGS DULY
EPOXY COATED TO PREVENT DETERIORATION OF INSULATION EVEN IN EXTREMELY HUMID
CONDITIONS. WINDING WIRE IS DUAL COATED SUITABLE FOR "H" CLASS INSULATION.
C] THE SEAL CHAMBER: THE HEART OF THE "MODY" PUMP. DUAL MECHANICAL SEALS,
TUNGSTEN CARBIDE V/S TUNGSTEN CARBIDE SEAL FACES. SECONDARY SEALS OF NITRILE
RUBBER AND METAL PARTS IN STAINLESS STEEL, RUNNING IN AN OIL BATH. THE SEALS
HAVE BEEN SPECIFICALLY DESIGNED WITH EXTREMELY SHORT WORKING LENGTHS KEEPING
IMPELLER OVERHANG TO THE MINIMUM. THIS ENSURES EXTENDED SEAL AND BEARING LIFE.
D] BEARINGS: DOUBLE ROW ANGULAR CONTACT LOWER BEARING, WITH SINGLE ROW DEEP
GROOVE UPPER BALL BEARING GREASED FOR LIFE WITH A SPECIAL HIGH TEMPERATURE
BEARING GREASE REQUIRING NO PERIODIC MAINTENANCE WHATSOEVER.
E] THE HYDRAULIC ELEMENTS: SINGLE CHANNEL IMPELLERS WITH LARGE SOLID HANDLING
CAPACITY. SMOOTH PROFILED VOLUTES FOR HIGH EFFICIENCES.
F] CABLE GLAND ASSEMBLY: THE PUMP IS SUPPLIED WITH 50’ CABLE AS STANDARD. THE
CABLE IS AWG W8 SOOW 4 CORE WITH AN OPTION AVAILABLE TRAILING CABLE 4 CORE WHEN
THERMAL OVERLOADS ARE SEAL PROOBE SENSOR ARE REQUIRED. THE CABLE IS TERMINATED
IN THE PUMP AT THE CABLE GLAND. THE GLAND ASSEMBLY SEALS THE CABLE ON THE
OUTSIDE SHEATH. A WATER DAM ARRANGEMENT IS ALSO PROVIDED WHICH SEALS THE
INDIVIDUAL CORES OF THE CABLE. THIS FEATURE IS UNIQUE AND IS ESSENTIAL TO
PREVENT WATER SEEPING THROUGH THE CORES OF THE CABLE INTO THE TERMINAL CHAMBER
IN THE EVENT OF A CUT CABLE. THE CABLE IS ALSO SHEATHED FOR THE 1ST ONE METRE
SERIES
LENGTH BY MEANS OF A CABLE GRIP MADE OF STAINLESS STEEL. THIS IS ESSENTIAL TO
ENSURE THAT THERE IS NO UNDUE STRAIN ON THE CABLE IF THE PUMP IS PULLED OR
LOWERED INADVERTENTLY BY MEANS OF THE CABLE. COMPLETE DETAILS OF THE CABLE
GLAND ASSEMBLY ARE SHOWN IN THE DRAWING.
G] ELECTRICAL INFORMATION : MOTORS ARE DESIGNED TO OPERATE ON SINGLE VOLTAGE
AND FREQUENCY. MAXIMUM DEVIATION IN VOLTAGE ALLOWED IS -/+ 6% AND FREQUENCY -/+
3%. CHECK NAME PLATE FOR OPERATING VOLTAGE AND FREQUENCY.
DESIGN PARAMETERS :
• LOWEST LIQUID LEVEL SHOULD BE 0.2 MTRS (8”) ABOVE PUMP CASING.
• THE MAXIMUM SUBMERGENCE RECCOMENDED IS 15 METRES.(50’)
• THE SPECIFIC GRAVITY OF THE PUMPED FLUID SHOULD NOT EXCEED 1.1.
• MAXIMUM FLUID TEMPERATURE IS 40 DEG. CELSUIS.
• pH OF THE PUMPED FLUID : 6 - 11
INSTALLATION
PUMPS ARE AVAIABLE FOR THREE TYPES OF INSTALLATION:
P TYPE INSTALLATION: SEMI PERMANENT/WET. PUMPS ARE LOWERED DOWN GUIDE BARS TO
AUTOMATICALLY CONNECT TO DISCHARGE PIPING. PLEASE SEE ILLUSTRATION AT END OF
MANUAL FOR DETAIL DIMENSIONS AND INSTALLATION.
S TYPE INSTALLATION: PORTABLE/WET. VERSATILE, MULTIPURPOSE, EASY TO INSTALL AND
MOVE FROM SUMP TO SUMP. PUMP IS AVAILABLE WITH HOSE/FLANGE TYPE OUTLET
CONNECTION AND INDEPENDENT BASE STAND. SEE ILLUSTRATION AT END OF MANUAL.
D TYPE INSTALLATION: THIS IS A DRY WELL INSTALLATION OR IN LINE PUMPING
SYSTEMS. FLANGED CONNECTION TO FIXED SUCTION AND DELIVERY PIPELINES. SUITABLE
FOR HORIZONTAL OR VERTICAL MOUNTING FOR DRY INSTALLATIONS. POWER LIMITATIONS
EXIST FOR CERTAIN MODELS AND EXTERNAL COOLING MAY BE NECESSARY. PLEASE CONTACT
FACTORY/SALES IF PUMP IS TO BE USED WITH THIS TYPE OF INSTALLATION.
• CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP.
• CHECK THAT FUSES ARE INTACT.
• USE SHORTEST POSSIBLE HOSE OF RECOMMENDED DIMENSION. AVOID SHARP BENDS,
CREASES AND CONTRACTIONS. FOR P TYPE AND D TYPE INSTALLATIONS ENSURE ALL
ACCESSORIES ARE AVAILABLE BEFORE STARTING INSTALLATION.
•NEVER LIFT OR PULL THE PUMP BY MEANS OF THE CABLE. SUSPEND THE PUMP BY A
ROPE/CHAIN OR PREFERABLY PLACE IT ON A SOLID BASE. FOR P TYPE INSTALLATIONS
THE REQUISITE CHAIN & TACKLE EQUIPMENT MUST BE AVAILABLE. PLEASE READ OUR
PUBLICATION REGARDING “P” TYPE INSTALLATION.
•WIRE THE PUMP TO THE MAINS CORRECTLY. ALWAYS USE A STARTER OR A PANEL BOARD.
SEE INSTRUCTIONS UNDER "MOTOR PROTECTION" BELOW.
•WHEN THE PUMP IS ENERGIZED IT WILL KICK, WHICH IS OPPOSITE TO THE DIRECTION
OF ROTATION OF THE IMPELLER. SHIFT TWO PHASES IN THE POWER CONNECTION IF THE
KICK IS IN THE WRONG DIRECTION. THE CORRECT DIRECTION IS INDICATED ON THE
PUMP COVER AT THE TOP OF THE PUMP.
•CHECK LEVEL AND CONDITION OF THE OIL AT SERVICE EVERY SIX MONTHS. IF THE OIL
IS EMULSIFIED BY WATER THE SEALS MUST BE REMOVED FROM THE ROTOR SHAFT FOR
FURTHER ACTION. THE SHAFT SEAL SHOULD BE CHECKED FOR WEAR EVERY 2500 HRS. OF
OPERATION. IF SEAL FACES SHOW ANY SIGNS OF WEAR, THEY SHOULD BE REPLACED.